Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “full stack”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

NSU Hack-a-Thon Workshop v.2.0

SAND2021-6722 O This is a fitness tracking mobile application and server created to train college-level students to build full stack software. The front end is written using an open-source framework called Flutter. The API server is written using an open-source python framework called Flask. The app functions as a workout tracker and is intentionally partially functional for the purpose of training students during the live workshops hosted by Sandia's HR recruiting teams. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Carpenter, Logan↗

Ard [SWR-25-18]

A wind farm optimization suite for wind energy that is built for modular, gradient-enabled multi-disciplinary and multi-fidelity optimizations. Dig into wind farm design. An ard is a type of simple and lightweight plow, used through the single-digit centuries to prepare a farm for planting. The intent of Ard is to be a modular, full-stack multi-disciplinary optimization tool for wind farms. The problem with wind farms is that they are complicated, multi-disciplinary objects. They are aerodynamic machines, with complicated control systems, power electronic devices, social and political objects, and the core value (and cost) of complicated financial instruments. Moreover, the design of one of these aspects affects all the rest! Ard seeks to make plant-level design choices that can incorporate these different aspects and their interactions to make wind energy projects more successful.

Frontin, Cory [National Renewable Energy Laborator↗

Quantum Network Repeater Simulation Package (QNPack) v1.0.0

Existing quantum network testbeds and prototypes are typically implemented in laboratory experiments with limited functionality and operate in a tightly coupled manner. These characteristics make it difficult to evaluate the behavior of emerging quantum platforms and protocols beyond local resource limitations. The QNPack software enables full-stack modeling of quantum repeater networks that allows researchers to simulate new approaches, and understand emergent behaviors, from local to national scales. Novel capabilities include: (1) performant and accurate quantum models that can be executed as independent simulations, which will allow users to characterize specific analog quantum processes, quantum devices, and protocols, (2) a modular and extensible approach to the simulation architecture to accommodate new quantum technologies, protocols, and topologies as they are developed across the quantum repeater generations under evaluation, and (3) a focus on managing the interactions between the simulation framework sub-components so that they may be re-used and composed in flexible ways.

Kissel, Ezra [Lawrence Berkeley National Laborator↗

qcal v0.0.1

qcal is a software package for calibration, characterization, and benchmarking of quantum gates. It was developed to operate full-stack superconducting quantum systems at the Advanced Quantum Testbed.

Hashim, Akel [Lawrence Berkeley National Laborator↗

Detector Interface for Streaming, Control, and Open-source integration (DISCO) v1.0.0

This suite consists of a multi-package ecosystem featuring detector emulators, EPICS areaDetector drivers, and remote server frameworks designed for the Advanced Light Source (ALS). Engineered for high-bandwidth devices—including VFCCD, Timepix3, Timepix4, and related pixel detectors—the software simulates hardware, wraps vendor SDKs into remote-callable servers, and integrates with open-source control systems. Key Capabilities: Distributed SDK Architecture: Server packages wrap hardware-specific SDKs, allowing areaDetector drivers to execute remote framework calls. This isolates proprietary libraries from the EPICS IOC, enhancing stability and enabling distributed computing across beamline networks. Device Support: Custom drivers for VFCCD, the Timepix family, and similar sensors optimize the data path from hardware control to high-speed transport. Full-Stack Emulation: Sophisticated emulator packages allow end-to-end pipeline testing and software development without requiring physical hardware or beam time. Integrated Workflows: Supports high-bandwidth streaming for real-time analysis and robust, metadata-rich file-based workflows (e.g., HDF5/NeXus). By standardizing interfaces across heterogeneous hardware, this suite reduces technical debt. It provides the ALS with a scalable, open-source solution to manage massive data rates within a unified control environment.

Mahl, Johannes [Lawrence Berkeley National Laborat↗

Cryocooler conduction-cooled SRF cavities for compact particle accelerators

Cryocooler conduction cooling offers simple, reliable cryogenics for developing industrial SRF e-beam accelerators. Conduction-cooled SRF R&D at Fermilab: first demonstration >6.5 MV/m cw on a 650 MHz Nb 3 Sn coated cavity; prototype development and high power accelerators designs in progress. Cryocooler conduction cooling can greatly expand access to SRF: university groups, industries can embark on in house SRF R&D without needing full stack helium cryogenic systems

43 PARTICLE ACCELERATORS↗

Ibis Networks/WattIQ (IN2 Final Report)

Ibis Networks is a full-stack cleantech company that provides plug-level energy monitoring and control to solve energy and asset management problems for the enterprise. During DATES – DATES, an NREL research team worked with the Ibis team to validate their product, the InteliSocket. The Ibis InteliSocket is a pass-through plug-load energy monitor and controller that is designed to reduce energy wasted by common 120 V plug-in devices in commercial office buildings, such as computer peripherals, conference room AV equipment, and break-room appliances. The system can shut off supply power to these end uses via remote control, manual switches, pre-set schedules, or automated control algorithms. The scope of this IN2 project was the development and refinement of “smart” learning behavior algorithms (LBAs), which could help installation processes and dramatically expand the sockets’ capabilities and energy-saving potential by suggesting suitable control schedules that are based on monitored use patterns. While Ibis has the analytical and software expertise for algorithm development, the lack of test data, both in a controlled laboratory setting and in real-life deployment scenarios, represented a key barrier toward commercialization of the product. Assistance through the IN2 program provided an opportunity to conduct the needed “trial and error” algorithm development. The project included baseline field-data collection, laboratory testing, and field validation components, all of which were conducted at the NREL campus between April 2017 and July 2019.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MLSPICE: Machine Learning based SPICE Modeling Platform for Power Magnetics

Electrical power converters are critical to a wide range of applications ranging from renewable integration to transportation electrification, and can be a key factor determining the size, weight, and efficiency of energy conversion systems. Magnetic components are typically the largest and least efficient components in power electronics. While there have been major strides in the modeling and analysis of power semiconductor devices and circuit simulations, the necessary advances in the design of power magnetics have lagged. In this project, we have transformed the modeling and design of power magnetics with machine learning enabled methods and catalyze simultaneous disruptive improvements for ML-based power electronics design tools. A fully automated open-source machine learning based magnetics modeling platform – the MagNet project - with innovations in full stack have been developed to greatly accelerate the design process and provide new insights to magnetic material and geometry design. The ARPA-E funded MagNet platform contains three major building blocks: 1) a ML-Integrated Data Acquisition System (MIDAS): a highly automated data acquisition testbed which is capable of measuring a large number of magnetic cores with a wide range of electrical circuit excitations; 2) a ML-integrated Core Loss Model (MICLM): a machine-learning trained modeling method for modeling the core loss and saturation effects of magnetic materials for arbitrary excitation waveforms; 3) ML-guided Magnetics SPICE Simulation Tool (PMSPICE): a fully integrated CAD tool which can simulate the magnetics in SPICE. It can help the designers to quickly model the linear and non-linear characteristics of magnetic components and evaluate their behavior in SPICE simulations. The developed MagNet system has fully demonstrated the proposed performance target and has been open sourced to the entire power electronics community to advance the modeling and design of power magnetics from many different angles.

36 MATERIALS SCIENCE↗

A Data Science and Machine Learning Platform Supporting Large Particle Accelerator Control and Diagnostics Applications Final Report: SBIR Initial Phase II DE-SC0022583

The Machine Learning Data Platform (MLDP) is a product providing full-stack support for data science, Machine Learning, and Artificial Intelligence (ML/AI) applications at particle accelerator and large experimental physics facilities. It supports ML/AI applications from front-end, high-speed acquisition of heterogeneous, time-series data, through data archiving and management, to back-end analysis. The MLDP embodies a “data-science ready” platform for data analysis and ML/AI applications in diagnosis, modelling, control, and optimization of these facilities. It provides data scientists and applications a consistent, datacentric interface to archive data standardizing implementation and deployment of ML/AI algorithms to different operations configurations within the same facility, or between facilities. Being an open-source, public-domain project, the MLDP is intended for broadest possible impact by increasing accessibility and minimizing the required expertise for installation and operation. The MLDP can also be deployed at user facilities for experimental data collection, archiving, and analysis. It is capable of acquisition and archiving of heterogeneous data from experimental equipment (e.g., images, arrays, structures, etc.) along with system hardware configurations (e.g., scalars, tables), control system process variables, and any metadata required for provenance. Thus, the MLDP can manage experimental data through its entire lifecycle, from acquisition and archiving, through analysis and investigation, to release and final publication.

43 PARTICLE ACCELERATORS↗

From IMT Device Measurements to Network-Level Consequences: When Learning Suppresses Beyond-LIF Neuron Dynamics

Emerging neuromorphic devices such as insulator--metal transition (IMT) devices exhibit complex temporal dynamics, including slow internal state memory, hysteresis, and burst-like firing, which are poorly captured by conventional leaky integrate-and-fire (LIF) neurons. However, it remains unclear when such dynamics influence learning and inference at the network level, particularly under commonly used unsupervised plasticity rules. We present a controlled, full-stack co-design study spanning experimental characterization of individual IMT devices, compact neuron model development, and large-scale spiking network simulations with identical architectures and learning rules. Rather than optimizing benchmark accuracy, our goal is to diagnose when neuron-level dynamics survive learning and competition, and when they are suppressed, to inform the co-design of devices, networks, and learning rules that can exploit beyond-LIF complexity.

42 ENGINEERING↗

CSB-RNN: A Faster-Than-Realtime RNN Acceleration Framework with Compressed Structured Blocks

Recurrent Neural Networks (RNN) is widely applied to temporal sequence analysis, where real-time performance is usually in demand. However, RNN suffers a heavy computational workload as the model comes with a large weight matrix. To alleviate the pain, model compression (pruning) schemes have been proposed for RNN that pruning the redundant (near-zero) weight-values. On the one hand, the non-structured pruning methods achieve a considerable pruning rate while bringing the computational irregularity, which is un-friendly to parallel-hardware. On the other hand, the existing structured pruning methods consider the hardware parallelism; However, they suffer a poor pruning rate due to the restrict constraints on pruning structure. This paper presents CSB-RNN, an optimized full-stack RNN framework with the novel compressed structured block (CSB) technique. The CSB-pruned RNN model comes with both fine-granularity that benefits the pruning rate and regular structure that facilitates the hardware-parallelism. Further, we propose a novel hardware architecture for inferencing the CSB-pruned model. Different from conventional parallel hardware, this architecture solves the block-workload imbalance issue and achieves an over 95% hardware utilization. With the experiments on 10 RNN models in 5 application domains, the CSB-RNN realizes 7×-20× lossless compression and up to 50× acceptable lossy-compression, which is 2×-7× to the prior art. With the addition of the novel hardware, the compressed-RNN inference reaches a super real-time latency of 10-400µs with FPGA implementation.

Shi, Runbin↗

How to Build a Quantum Supercomputer: Scaling from Hundreds to Millions of Qubits

In the span of four decades, quantum computation has evolved from an intellectual curiosity to a potentially realizable technology. Today, small-scale demonstrations have become possible for quantum algorithmic primitives on hundreds of physical qubits and proof-of-principle error-correction on a single logical qubit. Nevertheless, despite significant progress and excitement, the path toward a full-stack scalable technology is largely unknown. There are significant outstanding quantum hardware, fabrication, software architecture, and algorithmic challenges that are either unresolved or overlooked. These issues could seriously undermine the arrival of utility-scale quantum computers for the foreseeable future. Here, we provide a comprehensive review of these scaling challenges. We show how the road to scaling could be paved by adopting existing semiconductor technology to build much higher-quality qubits, employing system engineering approaches, and performing distributed quantum computation within heterogeneous high-performance computing infrastructures. These opportunities for research and development could unlock certain promising applications, in particular, efficient quantum simulation/learning of quantum data generated by natural or engineered quantum systems. To estimate the true cost of such promises, we provide a detailed resource and sensitivity analysis for classically hard quantum chemistry calculations on surface-code error-corrected quantum computers given current, target, and desired hardware specifications based on superconducting qubits, accounting for a realistic distribution of errors. Furthermore, we argue that, to tackle industry-scale classical optimization and machine learning problems in a cost-effective manner, heterogeneous quantum-probabilistic computing with custom-designed accelerators should be considered as a complementary path toward scalability.

Mohseni, Masoud↗

Optimization of Annealing for WZ-Phase Removal and Densification in Sb-Doped CdSexTe1-x Solar Cells

The impact of high temperature annealing (HTA) treatments on the performance of Sb-doped CdSeTe solar cells containing a CdSe0.25Te0.75/CdTe front stack and a vapor transport (VT) deposited CdTe:Sb absorber was studied. The HTA treatment of the thermally evaporated CdSe0.25Te0.75/CdTe front stack converts the mixed-phase film into a single zinc blende structure through recrystallization of the photo-inactive wurtzite phase. Subsequently, HTA treatment of the full device stack after vapor transport deposition of CdTe:Sb absorber promotes Se-Te intermixing, reduces voids, densifies the full stack and enhances CdTe:Sb grain growth. Comprehensive characterizations revealed that the combined HTA treatments significantly improved film crystallinity, removed the WZ phase in the front stack, enhanced full-stack densification, reduced defect densities, and enhanced carrier dynamics. With HTA treatments, the open-circuit voltage (VOC) of CdSeTe:Sb devices increased from ~ 400 mV to >= 600 mV, and when combined with optimized CdCl2 treatment, VOC reached 849 mV. The net carrier concentrations (NA-ND) of representative devices were NA-ND = 1.5 x 10^15, 1.1 x 10^15, and 3.5 x 10^14 cm-3 for the no-HTA, moderate-HTA, and optimized high-VOC conditions, respectively. Since the highest VOC corresponds to the lowest apparent NA-ND, , which is similar to a Cu-doped-only CdSeTe solar cell (NA-ND ~= 2 x 10^14 cm-3), the data indicate that improved device performance does not result from increased electrically active Sb; instead, it points to structural improvement as the dominant effect of HTA. The findings demonstrate the potential of HTA treatments to improve the structural and electrical properties of CdSeXTe1-X solar cells.

14 SOLAR ENERGY↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The WTP LAB stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the ANSI/HPS N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the DV of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The maximum 6 DV value from the scale model testing determines the maximum conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be = 20°. Second, the velocity uniformity at the full-scale stack must be = 20% COV. Finally, the velocity uniformity results for the actual and scale model stacks must agree within 5% COV. In general, these criteria were met through the full-scale stack tests at the LAB facility. Some specific items for each scale model and full-scale stack comparison should be noted in assessing the validity of the verification tests. The LB-C2 scale model stacks were performed with single fan operations at then-minimum flow conditions. These conditions resulted in DV values that were too low to meet the DV range criterion, and therefore are unable to be used in qualifying single fan operations on the full-scale stack. However, the single fan operations demonstrated COV values for velocity uniformity as well as flow angles that were comparable to the dual-fan operations at high flows. Overall, the test conditions and test results were within the range of acceptable values based on current design flow rates. Single fan operations are expected to only occur infrequently for maintenance needs and is therefore not a planned operating condition at this time. The LB-S1 scale model stacks were performed at three fan combinations, and in each combination, at least one test was performed at the then-minimum flow conditions as well as at then-maximum flow conditions. While the then-minimum flow conditions result in a DV range that is lower than the verification test DV value, and therefore does not meet the criterion, these tests are un-necessary for the verification test acceptance. The normal and maximum flow conditions from the scale model stack tests meet the DV range criterion, and the velocity uniformity test results compare favorably with the full-scale stack results. The LB-S2 scale model stacks were performed at nominally the same maximum flow condition; however, the 6 DV value for Fan A operation was slightly lower than the full-scale stack test DV. The COV values from the scale model stacks were comparable between the Fan A and Fan B results, and the overall test conditions are within the range of acceptable values. The stack verification is therefore considered acceptable for both Fan A and Fan B operations. The verification tests were performed at flows that were appreciably higher than the design conditions, and further elevated flow rates would be beyond the range of acceptable DV. Based on these stack verification test results, the three LAB filtered exhaust stacks meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard. Further changes to the system configuration or operating conditions that are outside the bounds described in this and the scale model test reports (Glissmeyer, Flaherty, and Piepel (2001), Glissmeyer and Geeting (2013)) may require additional tests and additional analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant Effluent Management Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant Effluent Management Facility (EMF) stack monitor location was qualified using a combination of scale model stacks to mitigate the risk of identifying that the sampling location does not meet the qualification criteria on the full-scale stack. The LV-S1 scale model stack was used as a baseline, augmented by the LB-S1 and LV-S2 scale model stacks to address the Direct Feed Low Activity Waste Effluent Management Facility Vessel Vent Process (DVP) injection into the main Active Confinement Ventilation (ACV) system duct. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling locations were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. The LV-S1, LB-S1, and LV-S2 scale model stack tests have met the criteria of the ANSI/HPS N13.1-1999 standard to demonstrate the stack sampling locations are well mixed. Verification tests of the EMF stack were performed at normal operating conditions. The minimum 1/6 DV value and the maximum 6 DV value from the scale model testing determine the range of stack flow rates for which the full-scale stack may be operated while remaining in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rate along with the average and maximum qualified stack flow rate based on the LV-S1 scale model DV values. The operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack test at the EMF. Flow angle results were <5°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition ranged between 2.2% COV and 4.3% COV, all of which were within the range of the target % COV values from the scale model tests on the LV-S1, LB-S1, and LV S2 scale models. Based on these stack verification test results, the EMF filtered exhaust stack sampling location meets the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all planned fan operating configurations. This includes each combination of ACV fans with DVP exhausters. Further changes to the system configuration or operating conditions that are outside the qualified flow rates described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing, determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rates along with the average and maximum qualified stack flow rates for each of the LAB facility stacks. For each stack, the operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10°, except for the LB-C2 Fan A results, which were an average of 13.7°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 4.1% COV, which were all within the range of the target percent coefficient of variation values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant Effluent Management Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant Effluent Management facility (EMF) stack monitor location was qualified using the LV-S1 scale model stack as a baseline, augmented by the LB-S1 and LV-S2 scale model stacks to address the Direct Feed Low Activity Waste Effluent Management Facility Vessel Vent Process (DVP) injection into the main Active Confinement Ventilation (ACV) system duct. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale models and its sampling locations were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the EMF stack was performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of stack flow rates for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on the LV-S1 scale model test DV values, the corresponding stack flow rates for the EMF stack are as listed in Table S1. Table S1. Effluent Management Facility Stack Qualified Flow Range. Stack Parameter EM-1 Minimum Qualified Stack Flow (scfm) 781 Maximum Qualified Stack Flow (scfm) 53,432 The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack test at the EMF. Flow angle results were less than 5°; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition ranged between 2.2% COV and 4.3% COV, which were all within the range of the target % COV values from the scale model tests on the LV-S1, LB-S1, and LV S2 scale models. Based on these stack verification test results, the EMF filtered exhaust stack sampling location meets the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes each combination of ACV fan with the DVP exhausters. Further changes to the system configuration or operating conditions that are outside the qualified flow rates described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on these DV values, the corresponding stack flow rates for each of the LAB stacks are 625 to 47,237 scfm for LB-C2, 1,704 to 103,131 scfm for LB-S1, and 467 to 18,088 scfm for LB-S2. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10 degrees, except for the LB-C2 Fan A results, which were an average of 17.6 degrees; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 3.5% COV, which were all within the range of the target %COV values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗