Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “frequency measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A novel Doppler backscattering (DBS) system to simultaneously measure radio frequency plasma fluctuations and low frequency turbulence

A novel quadrature Doppler Backscattering (DBS) system has been developed and optimized for the E-band (60–90 GHz) frequency range using either O-mode or X-mode polarization in DIII-D plasmas. In general, DBS measures the amplitude of density fluctuations and their velocity in the lab frame. The system can simultaneously monitor both low-frequency turbulence (f < 10 MHz) and radiofrequency plasma density fluctuations over a selectable frequency range (20–500 MHz). Detection of high-frequency fluctuations has been demonstrated for low harmonics of the ion cyclotron frequency (e.g., 2f ci ~ 23 MHz) and externally driven high-frequency helicon waves (f = 476 MHz) using an adjustable frequency down conversion system. Importantly, this extends the application of DBS to a high-frequency spectral domain while maintaining important turbulence and flow measurement capabilities. This unique system has low phase noise, good temporal resolution (sub-millisecond), and excellent wavenumber coverage (k θ ~ 1–20 cm –1 and kr ≲ 30 cm –1 ). As a demonstration, localized internal DIII-D plasma measurements are presented from turbulence (f ≤ 5 MHz), Alfvenic waves (f ~ 6.5 MHz), ion cyclotron waves (f ≥ 20 MHz), as well as fluctuations around 476 MHz driven by an external high-power 476 MHz helicon wave antenna. In the future, helicon measurements will be used to validate GENRAY and AORSA modeling tools for prediction of helicon wave propagation, absorption, and current drive location for the newly installed helicon current drive system on DIII-D.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Systems and methods for dual comb spectroscopy

A frequency-measurement method uses a dual frequency-comb spectrometer as an optical wavemeter to measure the frequency of a reference laser that is used to frequency-stabilize the spectrometer. The method includes measuring a walking rate of center bursts in a sequence of interferograms recorded by the spectrometer, determining a number of teeth in each of a plurality of Nyquist windows formed by the dual frequency-comb spectrometer, and determining a Nyquist number of the one Nyquist window covering the laser frequency. The reference laser frequency can then be determined from the number of teeth in each Nyquist window, the Nyquist number, and the comb spacing of either one of the two frequency combs of the dual frequency-comb spectrometer. The reference laser frequency does not need to be measured with a separate wavemeter, or calibrated with respect to a known atomic or molecular transition.

Rieker, Gregory B.↗

Sub-Hertz resonance by weak measurement

Weak measurement (WM) with state pre- and post-selection can amplify otherwise undetectable small signals and thus has potential in precision measurement applications. Although frequency measurements offer the hitherto highest precision due to the stable narrow atomic transitions, it remains a long-standing interest to develop new schemes to further escalate their performance. Here, we demonstrate a WM-enhanced correlation spectroscopy technique capable of narrowing the resonance linewidth down to 0.1 Hz in a room-temperature atomic vapour cell. The potential of this technique for precision measurement is demonstrated through weak magnetic-field sensing. By judiciously pre- and post-selecting frequency-modulated input and output optical states in a nearly orthogonal manner, a sensitivity of 7 fT Hz -1/2 at a low frequency near DC is achieved using only one laser beam with 15 µW of power. Additionally, our results extend the WM framework to a non-Hermitian Hamiltonian and shed new light on metrology and bio-magnetic field sensing.

Science & Technology - Other Topics↗

Characterization of fluid inside pipe using multi frequency electrical signal

A multi-frequency signal may be used to induce voltage difference across a portion of a pipe. The voltage difference may be induced to take multi-frequency measurement of impedance characteristics of fluid inside the pipe. The multi-frequency measurement of the impedance characteristic of the fluid inside the pipe may be used to determine a characteristic of the fluid inside the pipe. This may be achieved by active integration of experimental data with high-resolution multi-frequency electrical impedance tomography (MFEIT) modeling.

Chillara, Vamshi Krishna↗

On negative induced polarization in frequency domain measurements

SUMMARY Induced polarization (IP) has been widely used to non-invasively characterize electrical conduction and polarization in the subsurface resulting from an applied electric field. Earth materials exhibit a lossy capacitance defined by a negative intrinsic phase in frequency-domain IP (FDIP) or a positive intrinsic chargeability in time-domain IP (TDIP). However, error-free positive apparent phase or negative apparent chargeability (i.e. negative IP effects) can occur in IP measurements over heterogeneous media. While negative IP effects in TDIP data sets have been discussed, no studies have addressed this topic in detail for FDIP measurements. We describe theory and numerical modelling to explain the origin of negative IP effects in FDIP measurements. A positive apparent phase may occur when a relatively high polarizability feature falls into negative sensitivity zones of complex resistivity measurements. The polarity of the apparent phase is determined by the distribution of subsurface intrinsic phase and resistivity, with the resistivity impacting the apparent phase polarity via its control on the sensitivity distribution. A physical explanation for the occurrence of positive apparent phase data is provided by an electric circuit model representing a four-electrode measurement. We also show that the apparent phase polarity will be frequency dependent when resistivity changes significantly with frequency (i.e. in the presence of significant IP effects). Consequently, negative IP effects manifest themselves in the shape of apparent phase spectra recorded with multifrequency (spectral IP) data sets. Our results imply that positive apparent phase measurements should be anticipated and should be retained during inversion and interpretation of single frequency and spectral IP data sets.

Geochemistry & Geophysics↗

Metal-embedded fiber optic sensor packaging and signal demodulation scheme towards high-frequency dynamic measurements in harsh environments

Optical fiber-based sensors are commonly used for industrial monitoring and control processes due to their small size, resistance to electromagnetic interference, and ability to perform a wide variety of high-precision measurements. However, implementing optical fiber sensors in harsh environments is challenging because they are small and fragile. Proper packaging of fiber-optic sensors could extend their use to harsh environments, including at high temperature and under high radiation. Furthermore, conventional fiber optic-based measurement systems often use computationally expensive signal processing algorithms which hinder their use in high-frequency dynamic applications. This work reports on the design of an optical fiber-pressure sensor system based on low-coherence interferometry that uses a metal-embedded optical fiber to provide a robust sensor package. Additionally, a novel phase demodulation scheme is proposed to extract length changes from the deformation of a thin diaphragm within a Fabry–Pérot cavity to measure pressure. The sensor has been tested to ±100 kPa, has a theoretical linear response over a 270 kPa dynamic range (24 dB maximum signal-to-noise ratio), and can resolve pressure transients up to 3910 kPa/s. Sampling at 100 kHz, the present sensor can resolve 2 kPa dynamic pressures at frequencies up to 2 kHz. Faster transients on the order of tens to hundreds of kHz can theoretically be resolved at the expense of decreasing the maximum resolvable amplitude. A methodology for designing a LCI pressure sensor for a given application is outlined based on the limitations imposed by the Nyquist criterion, the diaphragm's resonant frequency, the LCI optoelectronics, and the phase demodulation scheme. The sensor is the first to implement a low-coherence light source and a Fabry–Pérot interferometer designed to provide real-time high-fidelity pressure measurements using a metal-embedded optical fiber. The demonstrated sensor provides a platform for sensing in harsh conditions such as in nuclear and energy applications.

47 OTHER INSTRUMENTATION↗

Gaining Insights in Loading Events for Wind Turbine Drivetrain Prognostics

Wind energy is one of the largest sources of renewable energy in the world. To further reduce the operations and maintenance (O&M) costs of wind farms, it is essential to be able to accurately pinpoint the root causes of different failure modes of interest. An example of such a failure mode that is not yet fully understood is white etching cracks (WEC). This can cause the bearing lifetime to be reduced to 5–10% of its design value. Multiple hypotheses are available in literature concerning its cause. To be able to validate or disprove these hypotheses, it is essential to have historic high-frequency measurement data (e.g., load and vibration levels) available. In time, this will allow linking to the history of the turbine operating data with failure data. This paper discusses the dynamic loading on the turbine during certain events (e.g., emergency stops, run-ups, and during normal operating conditions). By combining the number of specific events that each turbine has seen with the severity of each event, it becomes possible to assess which turbines are most likely to show signs of damage.

49 EE - Wind and Water Power Program - Wind (EE-4W↗

Frequency domain measurements of melt pool recoil force using modal analysis

Recoil pressure is a critical factor affecting the melt pool dynamics during Laser Powder Bed Fusion (LPBF) processes. Recoil pressure depresses the melt pool. When the recoil pressure is low, thermal conduction and capillary forces may be inadequate to provide proper fusion between layers. However, excessive recoil pressure can produce a keyhole inside the melt pool, which is associated with gas porosity. Direct recoil pressure measurements are challenging because it is localized over an area proportionate to the laser spot size producing a force in the mN range. This paper reports a vibrationbased approach to quantify the recoil force exerted on a part in a commercial LPBF machine. The measured recoil force is consistent with estimates from high speed synchrotron imaging of entrained particles, and the results show that the recoil force scales with applied laser power and is inversely related to the laser scan speed. These results facilitate further studies of melt pool dynamics and have the potential to aid process development for new materials.

42 ENGINEERING↗

Fast photodiode arrays for high frequency fluctuation measurements of reconnecting flux ropes

An array of compact, high-bandwidth (>200 MHz) and low-cost optical photodiodes has been developed and implemented on the PHASe MApping (PHASMA) experiment. Using purpose-built electronics, an array of 16 photodetectors was constructed and used to monitor broadband (1–5 MHz) fluctuations in light intensity emitted by flux ropes undergoing electron-only magnetic reconnection. These measurements reveal a swath of oscillatory behavior, including wave propagation inward toward the diffusion region at approximately the local electron Alfvén speed. Custom 3D-printed collection optics and mounting hardware allow quick reconfiguration of the array for radial or axial measurements. The electronics design is flexible enough to be used with other current-sourcing transducers, such as avalanche photodiodes; silicon photomultipliers; and infrared, x-ray, and UV photodiodes. A noise-rejecting electrical layout allows for low-noise operation close to pulsed plasma discharges. A 16-channel, 64-pixel tomographic array was constructed and initial reconstructions are presented.

Instruments & Instrumentation↗

Radio frequency electrical resistance measurement under destructive pulsed magnetic fields

We developed a resistance measurement using radio frequency reflection to investigate the electrical transport characteristics under destructive pulsed magnetic fields above 100 T. A sample stage consisting of a homemade flexible printed circuit reduced the noise caused by the induced voltage from the pulsed magnetic fields, improving the accuracy of the measurements of the reflected waves. From the obtained reflectance data, the absolute value of the magnetoresistance was successfully determined by analyzing the phase with admittance charts. In conclusion, these developments enable more accurate and comprehensive measurements of electrical resistance in pulsed magnetic fields.

47 OTHER INSTRUMENTATION↗

Mounted Accelerometer Frequency Response of Adhesive Products and Aluminum Frame Quick Mounts

An accelerometer mounting technique has large implications on the frequency range and accuracy of the measurement, with stiffness and the mass relative to the monitored structure as the primary concerns. The International Organization for Standardization (ISO) gives an extensive list in 5348:2021, detailing mounting methods, and provides recommendations for testing mounts that are not specifically defined. In the nuclear industry on the laboratory scale, there is a need for vibration measurements for predictive maintenance and process monitoring that are nondestructive and capable of working in high-temperature environments. Commercial adhesive products with easy application and removal were tested as nondestructive methods, while quick mounts to a commonly used aluminum frame were tested as nondestructive and have potential applicability in high-temperature environments. The sinusoidal excitation method was used, measuring frequencies from 50 Hz to 10 kHz in one-third octave band intervals, utilizing three accelerometers and comparing the results to those obtained with the stud-mounting method. Using the lowest ±3 dB threshold across each accelerometer, foam dots and poster strips were not successful, and foam tapes were accurate up to 2000 Hz, hose clamps and zip ties up to 800 Hz, and a custom 3D printed mount up to 1000 Hz. Knowing the limitations of each mounting technique allows for accurate measurements within the appropriate range.

47 - OTHER INSTRUMENTATION↗

Embedded Fiber Bragg Grating (FBG) Sensors Fabricated by Ultrasonic Additive Manufacturing for High-Frequency Dynamic Strain Measurements

This article demonstrates high-frequency dynamic strain measurements using fiber Bragg grating (FBG) sensors embedded in metal parts. Using an ultrasonic additive manufacturing (UAM) process, FBGs inscribed in polyimide coated optical fibers were embedded in aluminum parts. An electromagnetic shaker was used to exert dynamic events on the embedded FBG sensors with frequencies from 1 to 10 kHz. The high-speed interrogation of FBG sensors was accomplished using a tunable vertical-cavity surface-emitting laser (VCSEL) and a high-speed interrogation system sampling at 120 kHz. The strain response measured by the FBG sensors was compared with real-time measurements using a laser velocimeter. A finite-element analysis (FEA) was performed to simulate responses to both static strain and high-frequency dynamic strain. In conclusion, results show that strains as small as 2.5$με$ can be resolved at frequencies up to 10 kHz.

36 MATERIALS SCIENCE↗

Molecular structure determination: Equilibrium structure of pyrimidine (m-C 4 H 4 N 2 ) from rotational spectroscopy (reSE) and high-level ab initio calculation (re) agree within the uncertainty of experimental measurement

The pure rotational spectrum of pyrimidine (m-C 4 H 4 N 2 ), the meta-substituted dinitrogen analog of benzene, has been studied in the millimeter-wave region from 235 GHz to 360 GHz. The rotational spectrum of the ground vibrational state has been assigned and fit to yield accurate rotational and distortion constants. Over 1700 distinct transitions were identified for the normal isotopologue in its ground vibrational state and least-squares fit to a partial sextic S-reduced Hamiltonian. Transitions for all four singly substituted 13 C and 15 N isotopologues were observed at natural abundance and were likewise fit. Deuterium-enriched samples of pyrimidine were synthesized, giving access to all eleven possible deuterium-substituted isotopologues, ten of which were previously unreported. Experimental values of rotational constants and computed values of vibration–rotation interaction constants and electron-mass corrections were used to determine semi-experimental equilibrium structures (r e SE ) of pyrimidine. The r e SE structure obtained using coupled-cluster with single, double, and perturbative triple excitations [CCSD(T)] corrections shows exceptional agreement with the re structure computed at the CCSD(T)/cc-pCV5Z level (≤0.0002 Å in bond distance and ≤0.03° in bond angle). Of the various computational methods examined, CCSD(T)/cc-pCV5Z is the only method for which the computed value of each geometric parameter lies within the statistical experimental uncertainty (2σ) of the corresponding semi-experimental coordinate. The exceptionally high accuracy and precision of the structure determination is a consequence of the large number of isotopologues measured, the precision and extent of the experimental frequency measurements, and the sophisticated theoretical treatment of the effects of vibration–rotation coupling and electron mass. Taken together, these demanding experimental and computational studies establish the capabilities of modern structural analysis for a prototypical monocyclic aromatic compound.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Possibility of reducing nonlinear distortions of a frequency response of a gas ring laser with a periodic alternating frequency bias

We report a theoretical study of the dependence of the beat frequency of counterpropagating waves on the rotation velocity in a gas ring laser with a periodic alternating frequency bias. Rectangular biases of two types are considered: with constant amplitude and with periodic amplitude modulation. We have found dynamic zones for locking-in the counterpropagating wave frequencies and determined deviations of the frequency response from the ideal one that arise when measuring frequency nonreciprocities, close in magnitude to the amplitude of an alternating frequency bias. It is shown that in the case of a rectangular bias with periodic amplitude modulation, nonlinear distortions of the frequency response can be reduced by an order of magnitude. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Event Detection and Classification Using Machine Learning Applied to PMU Data for the Western US Power System

Smart grid technology enhances our comprehension and reliability of the power grid, leveraging Phasor Measurement Unit (PMU) data—time-synchronized, high-frequency measurements gathered across the US power grid. This paper employs machine learning techniques to effectively analyze the vast PMU data in Wide Area Monitoring Systems (WAMS) for power grid event detection and classification. Analyzing several months of real-world PMU data, the paper focuses on machine learning for fast, precise event detection and classification, corroborated by utility event logs. Practical challenges like feature extraction, dimensionality reduction, and model selection are addressed. A novel feature yielding improved results is discovered, and a supplementary algorithm for detecting small power grid faults is developed. The final algorithm is validated using a month-long real PMU data set, demonstrating its capability in accurately identifying power grid events in near real-time.

machine learning, event detection, PMU↗

Equalization of Intensity-Modulated Fiber-Optic Voltage Sensors for Power Distribution Systems

We test fiber-optic voltage sensors based on optical reflection from a piezoelectric transducer. Our specific devices possess a 2 kHz fundamental resonance, and we verify a readily usable frequency band from approximately 10 Hz to 3 kHz, with a dynamic range of 60 dB for a detection system integrating over this entire band. Additionally, we demonstrate a digital signal processing approach to equalize the measured frequency response, enabling accurate retrieval of short-pulse inputs. These results suggest the value and applicability of intensity-modulated fiber-optic voltage sensors for measuring both steady-state waveforms and broadband transients which, coupled with the straightforward and compact design of the sensors, should make them effective tools in electric grid monitoring.

42 ENGINEERING↗

Development of coated heat flux gauges for fast responding measurements

Thermal systems often exhibit transient behaviors that have important implications for the operation of the system and can be difficult to predict. For these reasons, experimental testing is often required to ensure system durability requirements are achieved. One important parameter governing the survivability of components in hot, high-stress environments is the heat flux into the part that dictates the temperature distribution for the component. However, sensors required to experimentally characterize heat fluxes in extreme environments must also be resilient. Here, this study presents the development of coated heat transfer gauges capable of robust, high-frequency measurements in turbine research facilities. The addition of a protective coating increases the durability of the gauge, but inherent of that coating is the attenuation of high-frequency temperature penetrations. As a result, this study first outlines the use of analytical solutions to define a gauge design for a specific frequency range and heat transfer, ensuring that subsurface signals can be rectified to surface conditions through inverse methods. Then, the fabrication of polyimide substrate sensors with a parylene-F coating is described. Micro surface heaters added to the custom sensors were used to determine important geometric and thermal properties necessary to calculate accurate surface heat flux. Ultimately, this work shows increased sensor robustness in a turbine test bed and experimentally validates that the frequency response of the fabricated sensors meet the design intent.

47 OTHER INSTRUMENTATION↗

Improved Accuracy in Semi-Experimental Structure Determination by Resolving Problems Associated with Rotation of Principal Inertial Axes of Isotopologues: Structures of 1,3-Oxazole ( c -C 3 H 3 NO)

The rotational spectrum of the normal isotopologue of 1,3-oxazole (c-C 3 H 3 NO) was observed from 43 to 750 GHz. Over 3900 transitions for the ground vibrational state are measured, assigned, and least-squares fit to sextic centrifugally distorted-rotor Hamiltonians. The measured frequencies and resulting spectroscopic constants from this extended spectral range, combined with previous measurements of the nuclear quadrupole coupling constants, will facilitate astronomical searches for oxazole across the majority of the range of modern radiotelescopes. Spectra for a set of 30 oxazole isotopologues, which include multiple isotopic substitutions of each atom, are used to determine the first semi-experimental equilibrium ($r$$^{SE}_{e}$) structure and semi-experimental substitution structure ($r$$^{SE}_{e}$), each using CCSD(T) computed values for the vibration–rotation interaction and electron-mass corrections. The large number of isotopologues, including 21 isotopologues observed for the first time, and the redundant substitutions of each atom provide sufficient spectroscopic information to determine the $r$$^{SE}_{e}$ structure with the expected high level of accuracy and precision (0.0001 or 0.0002 Å in bond distances and 0.013 to 0.025° in bond angles). In the course of this study, we analyzed a known issue for some $r$$^{SE}_{e}$ structure determinations of near-oblate asymmetric tops in which inclusion of individual isotopologues degrades the structure determination. We demonstrate that this problem primarily arises from the difference in the values of the computed vibration–rotation interaction corrections as evaluated at the computed re geometry vs the $r$$^{SE}_{e}$ geometry of the “real” molecule. Our solution to this problem substantially improves the $r$$^{SE}_{e}$ structure of oxazole and likely can be generalized to many other molecules.

Chemical structure↗