Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “framing camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

International testing of a Mars rover prototype

Tests on a prototype engineering model of the Russian Mars 96 Rover were conducted by an international team in and near Death Valley in the United States in late May, 1992. These tests were part of a comprehensive design and testing program initiated by the three Russian groups responsible for the rover development. The specific objectives of the May tests were: (1) evaluate rover performance over different Mars-like terrains; (2) evaluate state-of-the-art teleoperation and autonomy development for Mars rover command, control and navigation; and (3) organize an international team to contribute expertise and capability on the rover development for the flight project. The range and performance that can be planned for the Mars mission is dependent on the degree of autonomy that will be possible to implement on the mission. Current plans are for limited autonomy, with Earth-based teleoperation for the nominal navigation system. Several types of television systems are being investigated for inclusion in the navigation system including panoramic camera, stereo, and framing cameras. The tests used each of these in teleoperation experiments. Experiments were included to consider use of such TV data in autonomy algorithms. Image processing and some aspects of closed-loop control software were also tested. A micro-rover was tested to help consider the value of such a device as a payload supplement to the main rover. The concept is for the micro-rover to serve like a mobile hand, with its own sensors including a television camera.

Kemurjian, Alexsandr Leonovich↗

Imaging on ballistic missions to comet Encke

Imaging for navigation and science has been studied for a 1980 Encke flyby at 0.4 to 0.8 AU from the sun with spinning and three-axis spacecraft. Trajectory errors, maneuvers, encounter geometry, imaging performance, and data transmission were considered. Onboard comet sightings are needed for navigation. Recommended for a three-axis spacecraft are two vidicon cameras and a nucleus sensor for closed-loop pointing control. The cameras are essentially the Mariner 9 and Mariner 10 instruments; the nucleus sensor is an updated version of a sensor flown on Mariners 6 and 7. For a spinning spacecraft, a framing camera using a charge-coupled device and a spin-scan photometer are proposed. The framing camera would be a new design; it would not be despun, but the spin axis should point along the comet-centered velocity vector. The photometer is essentially that flown on Pioneer 10 and 11.-

Jaffe, L. D.↗

Experimental Investigation of Current Sheet Instabilities

Configuration space instabilities of propagating current sheets were studied in order to better understand acceleration mechanisms in pulsed plasma thrusters. Experiments were carried out in a parallel plate accelerator with argon as propellant. Propagating current sheets were visualized using fast framing cameras with inter-frame delays ranging between 0.05 - 2 microsecond. Schlieren photography using a pulse-burst Nd:YAG laser was used to image electron density gradients in the discharge. Magnetic field probes were used to map the magnetic field topology during the evolution of the discharge. Pressure probes were used to monitor axial pressure gradients. Emission spectroscopy was used to estimate the electron temperature in the arc. The motivation for applying all of these diagnostics was to gain an understanding of what parameters influence the macroscopic stability of a propagating current sheet. Since a stable current sheet is required for any effective snowplow-type of accelerator, an understanding of the processes which can cause current sheets to break apart into filaments is essential for the design of future pulsed plasma thrusters.

Markusic, Thomas E.↗

Hypervelocity impact studies using a rotating mirror framing laser shadowgraph camera

The need to study the effects of the impact of micrometeorites and orbital debris on various space-based systems has brought together the technologies of several companies and individuals in order to provide a successful instrumentation package. A light gas gun was employed to accelerate small projectiles to speeds in excess of 7 km/sec. Their impact on various targets is being studied with the help of a specially designed continuous-access rotating-mirror framing camera. The camera provides 80 frames of data at up to 1 x 10 to the 6th frames/sec with exposure times of 20 nsec.

Parker, Vance C.↗

MHD mode tracking using high-speed cameras and deep learning

Abstract We present a new algorithm to track the amplitude and phase of rotating magnetohydrodynamic (MHD) modes in tokamak plasmas using high speed imaging cameras and deep learning. This algorithm uses a convolutional neural network (CNN) to predict the amplitudes of the n = 1 sine and cosine mode components using solely optical measurements from one or more cameras. The model was trained and tested on an experimental dataset consisting of camera frame images and magnetic-based mode measurements from the High Beta Tokamak - Extended Pulse (HBT-EP) device, and it outperformed other, more conventional, algorithms using identical image inputs. The effect of different input data streams on the accuracy of the model’s predictions is also explored, including using a temporal frame stack or images from two cameras viewing different toroidal regions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Rover mast calibration, exact camera pointing, and camara handoff for visual target tracking

This paper presents three technical elements that we have developed to improve the accuracy of the visual target tracking for single-sol approach-and-instrument placement in future Mars rover missions. An accurate, straightforward method of rover mast calibration is achieved by using a total station, a camera calibration target, and four prism targets mounted on the rover. The method was applied to Rocky8 rover mast calibration and yielded a 1.1-pixel rms residual error. Camera pointing requires inverse kinematic solutions for mast pan and tilt angles such that the target image appears right at the center of the camera image. Two issues were raised. Mast camera frames are in general not parallel to the masthead base frame. Further, the optical axis of the camera model in general does not pass through the center of the image. Despite these issues, we managed to derive non-iterative closed-form exact solutions, which were verified with Matlab routines. Actual camera pointing experiments aver 50 random target image paints yielded less than 1.3-pixel rms pointing error. Finally, a purely geometric method for camera handoff using stereo views of the target has been developed. Experimental test runs show less than 2.5 pixels error on high-resolution Navcam for Pancam-to-Navcam handoff, and less than 4 pixels error on lower-resolution Hazcam for Navcam-to-Hazcam handoff.

camera handoff↗

Data analysis for GOPEX image frames

The data analysis based on the image frames received at the Solid State Imaging (SSI) camera of the Galileo Optical Experiment (GOPEX) demonstration conducted between 9-16 Dec. 1992 is described. Laser uplink was successfully established between the ground and the Galileo spacecraft during its second Earth-gravity-assist phase in December 1992. SSI camera frames were acquired which contained images of detected laser pulses transmitted from the Table Mountain Facility (TMF), Wrightwood, California, and the Starfire Optical Range (SOR), Albuquerque, New Mexico. Laser pulse data were processed using standard image-processing techniques at the Multimission Image Processing Laboratory (MIPL) for preliminary pulse identification and to produce public release images. Subsequent image analysis corrected for background noise to measure received pulse intensities. Data were plotted to obtain histograms on a daily basis and were then compared with theoretical results derived from applicable weak-turbulence and strong-turbulence considerations. Processing steps are described and the theories are compared with the experimental results. Quantitative agreement was found in both turbulence regimes, and better agreement would have been found, given more received laser pulses. Future experiments should consider methods to reliably measure low-intensity pulses, and through experimental planning to geometrically locate pulse positions with greater certainty.

Levine, B. M.↗

High-speed camera synchronization

Photoelectric sensor enables synchronization of the rotating mirror in a high-speed framing camera with the passage of a very-high-velocity droplet to obtain direct photographic data on droplet breakup. It detects droplet movement across a high intensity light beam and generates a signal triggering the camera.

Rojec, E. A.↗

Post-Shot Report for OMEGA Double Cylinders (CylDRT 22B)

The direct-drive double cylinder experimental platform is a high-energy-density (HED) science platform designed to image an imploding cylindrical target. The target consists of a directly-driven outer cylinder and a shock-and-collision driven inner cylinder. The purpose of this platform is to study hydrodynamic instability growth on the inner cylinder, the outer surface of which is classically Rayleigh-Taylor unstable during the acceleration phase. We present results from recent experiments at the OMEGA laser facility. These experiments were designed as a proof-of-principle for the platform, using the same cylinder exterior dimensions and direct-drive beam configuration as previous single cylinder experiments. In these experiments, three sets of targets were fielded: no machined perturbations (smooth), a sinusoidal mode-10 perturbation on the outer surface of the inner cylinder, and a mode-20 perturbation on the outer surface of the inner cylinder. The primary diagnostic was a gated x-ray framing camera which imaged the backlit inner cylinder on-axis for sixteen frames over a time window of 1 ns for each shot. A second side-lit radiograph captured one image per shot, diagnosing axial uniformity. In this report we include an overview of the results from both the backlighter and the sidelighter diagnostics. We discuss at length the experimental analysis process. Finally, we present the results of the smooth target implosion trajectory and compare them to post-shot simulations. We see favorable agreement between simulation and experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preliminary design of an intermittent smoke flow visualization system

A prototype intermittent smoke flow visualization system for studying the flowfield of an aircraft in flight has been constructed and demonstrated. It provides discrete pulses of dense white smoke suitable for video imaging to determine the unsteady vortex core trajectory of fluid elements in a high angle-of-attack flowfield. Two methods of pulsing the smoke were initially investigated: (1) periodically diverting the smoke between two exit ports and (2) completely blocking the smoke flow for short times. System dynamics have been modeled mathematically, data have been collected in a wind tunnel with blockage times up to 80 milliseconds, and the prototype is currently being flown on a general aviation airplane to collect three-dimensional video data. Three different plenum chamber sizes are available. Data collected so far are consistent and repeatable, though care must be taken to provide adequate contrast levels for accurate video resolution. Camera frame rates of at least 180 frames/second and wide angle lenses for the video cameras are needed to acquire meaningful vortex core velocities and accelerations for the general aviation test aircraft installation.

Ward, D. T.↗

Particle displacement tracking applied to air flows

Electronic Particle Image Velocimeter (PIV) techniques offer many advantages over conventional photographic PIV methods such as fast turn around times and simplified data reduction. A new all electronic PIV technique was developed which can measure high speed gas velocities. The Particle Displacement Tracking (PDT) technique employs a single cw laser, small seed particles (1 micron), and a single intensified, gated CCD array frame camera to provide a simple and fast method of obtaining two-dimensional velocity vector maps with unambiguous direction determination. Use of a single CCD camera eliminates registration difficulties encountered when multiple cameras are used to obtain velocity magnitude and direction information. An 80386 PC equipped with a large memory buffer frame-grabber board provides all of the data acquisition and data reduction operations. No array processors of other numerical processing hardware are required. Full video resolution (640x480 pixel) is maintained in the acquired images, providing high resolution video frames of the recorded particle images. The time between data acquisition to display of the velocity vector map is less than 40 sec. The new electronic PDT technique is demonstrated on an air nozzle flow with velocities less than 150 m/s.

Wernet, Mark P.↗

Particle displacement tracking applied to air flows

Electronic Particle Image Velocimetric (PIV) techniques offer many advantages over conventional photographic PIV methods such as fast turn around times and simplified data reduction. A new all electronic PIV technique was developed which can measure high speed gas velocities. The Particle Displacement Tracking (PDT) technique employs a single CW laser, small seed particles (1 micron), and a single intensified, gated CCD array frame camera to provide a simple and fast method of obtaining two-dimensional velocity vector maps with unambiguous direction determination. Use of a single CCD camera eliminates registration difficulties encountered when multiple cameras are used to obtain velocity magnitude and direction information. An 80386 PC equipped with a large memory buffer frame-grabber board provides all of the data acquisition and data reduction operations. No array processors of other numerical processing hardware are required. Full video resolution (640 x 480 pixel) is maintained in the acquired images, providing high resolution video frames of the recorded particle images. The time between data acquisition to display of the velocity vector map is less than 40 sec. The new electronic PDT technique is demonstrated on an air nozzle flow with velocities less than 150 m/s.

Wernet, Mark P.↗

Ambient-Light-Canceling Camera Using Subtraction of Frames

The ambient-light-canceling camera (ALCC) is a proposed near-infrared electronic camera that would utilize a combination of (1) synchronized illumination during alternate frame periods and (2) subtraction of readouts from consecutive frames to obtain images without a background component of ambient light. The ALCC is intended especially for use in tracking the motion of an eye by the pupil center corneal reflection (PCCR) method. Eye tracking by the PCCR method has shown potential for application in human-computer interaction for people with and without disabilities, and for noninvasive monitoring, detection, and even diagnosis of physiological and neurological deficiencies. In the PCCR method, an eye is illuminated by near-infrared light from a lightemitting diode (LED). Some of the infrared light is reflected from the surface of the cornea. Some of the infrared light enters the eye through the pupil and is reflected from back of the eye out through the pupil a phenomenon commonly observed as the red-eye effect in flash photography. An electronic camera is oriented to image the user's eye. The output of the camera is digitized and processed by algorithms that locate the two reflections. Then from the locations of the centers of the two reflections, the direction of gaze is computed. As described thus far, the PCCR method is susceptible to errors caused by reflections of ambient light. Although a near-infrared band-pass optical filter can be used to discriminate against ambient light, some sources of ambient light have enough in-band power to compete with the LED signal. The mode of operation of the ALCC would complement or supplant spectral filtering by providing more nearly complete cancellation of the effect of ambient light. In the operation of the ALCC, a near-infrared LED would be pulsed on during one camera frame period and off during the next frame period. Thus, the scene would be illuminated by both the LED (signal) light and the ambient (background) light during one frame period, and would be illuminated with only ambient (background) light during the next frame period. The camera output would be digitized and sent to a computer, wherein the pixel values of the background-only frame would be subtracted from the pixel values of the signal-plus-background frame to obtain signal-only pixel values (see figure). To prevent artifacts of motion from entering the images, it would be necessary to acquire image data at a rate greater than the standard video rate of 30 frames per second. For this purpose, the ALCC would exploit a novel control technique developed at NASA s Jet Propulsion Laboratory for advanced charge-coupled-device (CCD) cameras. This technique provides for readout from a subwindow [region of interest (ROI)] within the image frame. Because the desired reflections from the eye would typically occupy a small fraction of the area within the image frame, the ROI capability would make it possible to acquire and subtract pixel values at rates of several hundred frames per second considerably greater than the standard video rate and sufficient to both (1) suppress motion artifacts and (2) track the motion of the eye between consecutive subtractive frame pairs.

Morookian, John Michael↗

Geologic sketch map of the candidate Proclus Apollo landing site, part K

An Apollo 15 panoramic camera frame was used as a base for a geologic sketch map of an area near Proclus Crater. The map was prepared to investigate the usefulness of the panoramic camera photography in large-scale geologic mapping and to assess the geologic value of the area as a potential Apollo landing site. The photographs, taken under high solar illumination, resulted in good definition of albedo features, and stereoscopic viewing provided extreme clarity of topographic relief with terrain units easily delineated. The geological characteristics of the area as evidenced by the high-resolution photographs is discussed. It is concluded that the panoramic camera photographs reveal a wealth of detail and are eminently suited for geologic mapping purposes. In addition, the Proclus area, as a potential landing site, offers relatively rough plains terrain.

Lucchitta, B. K.↗

CCD imaging instruments for planetary spacecraft applications

The development of new spacecraft camera systems to be used in conjunction with CCD sensors is reported. A brief overview of the science objectives and engineering constraints which influence the design of cameras for deep space is followed by a review of two current development programs, one leading to a line scan imager and the other to an area array frame camera. For each of these, a general description of the imager is given. It is evident that currently available CCDs fall short of requirements in some respects.

Reilly, T. H.↗

Dawn Orbit Determination Team: Modeling and Fitting of Optical Data at Vesta

The Dawn spacecraft was launched on September 27th, 2007. Its mission is to consecutively rendezvous with and observe the two largest bodies in the main asteroid belt, Vesta and Ceres. It has already completed over a year's worth of direct observations of Vesta (spanning from early 2011 through late 2012) and is currently on a cruise trajectory to Ceres, where it will begin scientific observations in mid-2015. Achieving this data collection required careful planning and execution from all Dawn operations teams. Dawn's Orbit Determination (OD) team was tasked with reconstruction of the as-flown trajectory as well as determination of the Vesta rotational rate, pole orientation and ephemeris, among other Vesta parameters. Improved knowledge of the Vesta pole orientation, specifically, was needed to target the final maneuvers that inserted Dawn into the first science orbit at Vesta. To solve for these parameters, the OD team used radiometric data from the Deep Space Network (DSN) along with optical data reduced from Dawn's Framing Camera (FC) images. This paper will de-scribe the initial determination of the Vesta ephemeris and pole using a combination of radiometric and optical data, and also the progress the OD team has made since then to further refine the knowledge of Vesta's body frame orientation and rate with these data.

imagery↗