Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fluorescent composites”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Chemical and spectroscopic characterization of a suite of Mars soil analogs

The National Aeronautics and Space Administration has begun preparations for the flight of the Mars Observer Mission in the early 1990s. An advanced ground-based study is being conducted on a usefully limited suite of Mars Soil Analog Materials (MarSAM) intended to simulate the aeolian material covering the surface of Mars. A series of variably proportioned iron/calcium smectite clays were prepared from a typical montmorillonite clay using the Banin method. The effect of increasing iron on a diverse set of chemical and spectroscopic properties of the suite of clays is discussed. In order to chemically characterize the MarSAM and compare them with the Martian soil studied by Viking, the clays were analyzed for their major and minor elemental compositions by X-ray fluorescence and ion-coupled plasma techniques. It was concluded that the surface iron has a complex and hitherto uninvestigated impact on the catalytic and spectroscopic properties of clays and on the ability of these material to store energy.

Coyne, L. M.↗

Biochemical Detection and Identification False Alarm Rate Dependence on Wavelength Using Laser Induced Fluorescence

Most organic and many inorganic materials absorb strongly in specific wavelength ranges in the deep UV between about 220nm and 300nm. Excitation within these absorption bands results in native fluorescence emission. Each compound or composite material, such as a bacterial spore, has a unique excitation-emission fingerprint that can be used to provide information about the material. The sensitivity and specificity with which these materials can be detected and identified depends on the excitation wavelength and the number and location of observation wavelengths.We will present data on our deep ultraviolet Targeted Ultraviolet Chemical Sensors that demonstrate the sensitivity and specificity of the sensors. In particular, we will demonstrate the ability to quantitatively differentiate a wide range of biochemical agent targets against a wide range of background materials. We will describe the relationship between spectral resolution and specificity in target identification, as well as simple, fast, algorithms to identify materials.Hand-held, battery operated instruments using a deep UV laser and multi-band detection have been developed and deployed on missions to the Antarctic, the Arctic, and the deep ocean with the capability of detecting a single bacterial spore and to differentiate a wide range of organic and biological compounds.

native flourescence↗

Stardust Interstellar Preliminary Examination V: XRF Analyses of Interstellar Dust Candidates at ESRF ID13

Here, we report analyses by synchrotron X-ray fluorescence microscopy of the elemental composition of eight candidate impact features extracted from the Stardust Interstellar Dust Collector (SIDC). Six of the features were unambiguous tracks, and two were crater-like features. Five of the tracks are so-called midnight tracks that is, they had trajectories consistent with an origin either in the interstellar dust stream or as secondaries from impacts on the Sample Return Capsule (SRC). In a companion paper reporting synchrotron X-ray diffraction analyses of ISPE candidates, we show that two of these particles contain natural crystalline materials: the terminal particle of track 30contains olivine and spinel, and the terminal particle of track 34 contains olivine. Here, we show that the terminal particle of track 30, Orion, shows elemental abundances, normalized to Fe, that are close to CI values, and a complex, fine-grained structure. The terminal particle of track 34, Hylabrook, shows abundances that deviate strongly from CI, but shows little fine structure and is nearly homogenous. The terminal particles of other midnight tracks, 29 and 37, had heavy element abundances below detection threshold. A third, track28, showed a composition inconsistent with an extraterrestrial origin, but also inconsistent with known spacecraft materials. A sixth track, with a trajectory consistent with secondary ejecta from an impact on one of the spacecraft solar panels, contains abundant Ce and Zn. This is consistent with the known composition of the glass covering the solar panel. Neither crater-like feature is likely to be associated with extraterrestrial materials. We also analyzed blank aerogel samples to characterize background and variability between aerogel tiles. We found significant differences in contamination levels and compositions, emphasizing the need for local background subtraction for accurate quantification.

Stardust↗

Onboard Data Analysis for the Planetary Instrument for X-Ray Lithography

Imaging spectrometers are invaluable instruments for robotic science exploration, enabling quantitative maps of physical and chemical properties at high spatial resolution. This is particularly valuable in remote missions to other planetary bodies like Mars. The PIXL instrument on the Mars 2020 rover will deploy an arm-mounted X-Ray fluorescence spectrometer to map chemical composition at sub-millimeter scales. Its high resolution places dramatic new demands on instrument placement accuracy and measurement time. We address these challenges using novel on board data analysis strategies inspired by FRC science autonomy research.

Thompson, David R.↗

Characterization of NUW-LHT-5m, A Lunar Highland Simulant

A new simulant of the lunar highlands regolith, NUW-LHT-5M, was designed by NASA and manufactured by Washington Mills. The simulant was based on Apollo 16 data and is a member of the NU-LHT-series. NASA’s Marshall Space Flight Center and Johnson Space Center have already purchased 3 metric tons of the simulant for advanced engineering work. In support of engineering uses of the simulant, we provided measurements of the simulant including: mineral abundance and composition, liberation, X-ray fluorescence (XRF), ferrous iron, carbon, sulfur, 60 element inductively coupled plasma (ICP), loss on ignition, particle size, both 2D and 3D particle shape, specific surface area, shear, cohesion, internal friction, helium pycnometry, minimum index density, tap density, magnetic susceptibility, cryogenic and high temperature permittivity, visible and near-infrared (VNIR) and middle infra-red spectroscopy (MIR), differential scanning calorimetry (DSC), viscosity, thermal diffusivity, thermal conductivity, thermal gravimetric analysis (TGA), evolved gas analysis (EGA), and spark sintering. For the crystalline components the design of the simulant called for two rocks from the Stillwater Complex, Montana: 17.6 wt% norite, 37.7% anorthosite, and 4.7 wt% olivine from an unspecified commercial source. The other 40% of the simulant was a high calcium (An100), vesicular glass that Washington Mills made specifically for the simulant. Fabrication and quality control processes for both the glass and the simulant are described. Importantly, most of the graphs and tables presented herein provide values for both the new simulant and data for the older NASA mare simulant, JSC-1A. Finally, we discussed the current limitations of NUW-LT-5M and most other lunar regolith simulants to replicate the lunar material.

lunar regolith simulant↗

Major Element Analysis of the Target Rocks at Meteor Crater, Arizona

We collected approximately 400 rock chips in continuous vertical profile at Meteor Crater, Arizona, representing, from bottom to top, the Coconino, Toroweap, Kaibab, and Moenkopi Formations to support ongoing compositional analyses of the impact melts and their stratigraphic source depth(s) and other studies at Meteor Crater that depend on the composition of the target rocks. These rock chips were subsequently pooled into 23 samples for compositional analysis by XRF (x ray fluorescence) methods, each sample reflecting a specific stratigraphic "subsection" approximately 5-10 in thick. We determined the modal abundance of quartz, dolomite, and calcite for the entire Kaibab Formation at vertical resolutions of 1-2 meters. The Coconino Formation composes the lower half of the crater cavity. It is an exceptionally pure sandstone. The Toroweap is only two inches thick and compositionally similar to Coconino, therefore, it is not a good compositional marker horizon. The Kaibab Formation is approximately 80 in thick. XRD (x ray diffraction) studies show that the Kaibab Formation is dominated by dolomite and quartz, albeit in highly variable proportions; calcite is a minor phase at best. The Kaibab at Meteor Crater is therefore a sandy dolomite rather than a limestone, consistent with pronounced facies changes in the Permian of SE Arizona over short vertical and horizontal distances. The Moenkopi forms the 12 in thick cap rock and has the highest Al2O3 and FeO concentrations of all target rocks. With several examples, we illustrate how this systematic compositional and modal characterization of the target ideologies may contribute to an understanding of Meteor Crater, such as the depth of its melt zone, and to impact cratering in general, such as the liberation of CO2 from shocked carbonates.

See, Thomas H.↗

Elemental composition of the Martian surface

The Viking landers carried X-ray fluorescence spectrometers (XRFS) to the surface of Mars for direct in-situ measurements of the elemental composition of samples that could be acquired by the surface sampler scoops. A total of 21 samples at two landing sites were acquired and analyzed. In this review, the constraints imposed on the design and operation of the XRFS; the accuracy and precision limitations of XRF; and the interpretation of the results are discussed. The latter includes relevance of the investigation to Martian geological processes, SNC meteorites, the formation and history of Mars, and future mission objectives/capabilities.

Clark, Benton C.↗

Environmental effects on laser-induced fluorescence spectra of natural waters

Laser fluorosensing can be used to monitor dissolved organic carbon (DOC), but analysis of the data can be hindered by several environmental phenomena. These phenomena include attenuation of the laser beam and differential attenuation of the fluorescence by the water column, variability in the molecular weight composition of the DOC, and temperature, pH, and metal ion effects on DOC fluorescence. These factors are discussed in terms of their effect on laboratory and remote field data analysis. Experimental results are provided. Analysis of fluorosensor data of DOC may be improved by compensating for the environmental factors. An improved methodology is discussed, and a suggestion is made for indirect monitoring of pH and metal ion concentration.

Vodacek, Anthony↗

In Situ Mineralogical Analysis of Planetary Materials Using X-Ray Diffraction and X-Ray Fluorescence

Remote observations of Mars have led scientists to believe that its early climate was similar to that of the early Earth, having had abundant liquid water and a dense atmosphere. One of the most fascinating questions of recent times is whether simple bacterial life developed on Mars (as it did on the Earth) during this early element period. Analyses of SNC meteorites have broadened considerably our knowledge of the chemistry of certain types of Martian rocks, underscoring the tantalizing possibility of early hydrothermal systems and even of ancient bacterial life. Detailed analyses of SNC meteorites in Terrestrial laboratories utilize the most sophisticated organic, isotopic and microscopic techniques in existence. Indeed; it is unlikely that the key biogenic indicators used in McKay et al (ibid) could be identified by a remote instrument on the surface of Mars. As a result, it is probable that any robotic search for evidence of an ancient Martian biosphere will have as its focus the identification of key minerals in likely host rocks rather than the direct detection of organic or isotopic biomarkers. Even on a sample return mission, mineralogical screening will be utilized to choose the most likely candidate rocks. X-ray diffraction (XRD) is the only technique that can provide a direct determination of the crystal structures of the phases present within a sample. When many different crystalline phases are present, quantitative analysis is better constrained if used in conjunction with a determination of elemental composition, obtainable by X-ray fluorescence (XRF) using the same X-ray source as for XRD. For planetary surface analysis, a remote instrument combining XRD and XRF could be used for mineralogical characterization of both soils and rocks. We are designing a remote XRD/XRF instrument with this objective in mind. The instrument concept pays specific attention to constraints in sample preparation, weight, volume, power, etc. Based on the geometry of a pinhole camera (transmission geometry, flat two-dimensional detector perpendicular to the direct beam), the instrument (which we call CHEMIN, for Chemistry and Mineralogy) uses an X-ray sensitive CCD detector which will allow concurrent positional and energy-dispersive analysis of collected photons. Thus XRF (energy) and XRD (geometry) analysis of transmitted X-rays will be performed at the same time. Tests performed with single minerals and simple mixtures give promising results. Refinements of the prototype promise interpretable results on complex samples.

Sarrazin, P.↗

Rejoining and misrejoining of radiation-induced chromatin breaks. I. experiments with human lymphocytes

Fluorescence in situ hybridization with a composite probe for human chromosome 4 and a probe that stained all centromeres was used to study gamma-ray induced breakage, rejoining and misrejoining in prematurely condensed chromosomes in human lymphocytes. Dose-response curves for the induction of all types of aberrations in prematurely condensed human chromosomes 4 were determined immediately after irradiation and after 8 h postirradiation incubation. In addition, aberrations were measured after various incubation times from 0 to 18 h after a dose of 7 Gy. Unrejoined chromosome breaks were the most frequent type of aberration observed immediately after irradiation. Approximately 15% of total aberrations observed were chromosome exchanges. After 8 h postirradiation incubation, the frequency of breaks in prematurely condensed chromosomes declined to about 20% of the initial value, and chromosomal exchanges became the most frequent aberration. Results of metaphase analysis were similar to those for prematurely condensed chromosomes after 8 h incubation with the exception that a significantly lower frequency of fragments was observed. Symmetrical and asymmetrical interchanges were found at similar frequencies at all doses. No complex exchanges were observed in lymphocyte chromosomes immediately after exposure. They accounted for about 1% of total exchanges in metaphase chromosomes at doses <3 Gy and about 14% at 7 Gy. Incomplete exchanges amounted to approximately 15% of total exchanges at all doses. The kinetics of break rejoining was exponential, and the frequency of exchanges increased with kinetics similar to that observed for the rejoining of the breaks. This increase in the total exchanges as a function of the time between irradiation and fusion was due to a rapid increase in reciprocal interchanges, and a slower increase in complex exchanges; the frequency of incomplete exchanges increased initially, then decreased with prolonged incubation to the level observed in metaphase. It is concluded that the formation of each kind of chromosome aberrations follows different kinetics.

NASA Discipline Radiation Health↗

Chemical and morphological changes of reusable surface insulation coatings as a function of convectively heated cyclic testing

The effects of convective heating upon reusable surface insulation coatings were studied utilizing scanning electron microscopy, X-ray fluorescence, and X-ray diffraction. Samples of coated silica, mullite, and ceramic mullite fiber were cycled in an arc plasma stream up to 15 times for 15 minutes per cycle at surface temperatures simulating those on the space shuttle vehicle. The surfaces of ceramic mullite fiber and mullite coatings were roughened substantially by the convectively heated environment while the silica was significantly smoothed after testing. Scanning electron microscopy also showed surface cracking of varying degrees in all of the coatings. The surface chemistry of the coatings as examined by X-ray fluorescence revealed that significant changes in composition were occurring during cycling, particularly within the mullite coating.

Leiser, D. B.↗

Experimental and Theoretical Analysis of Chemical Vapor Deposition with Prediction of Gravity Effects

A combined experimental and theoretical study to characterize the effects of gravitationally-induced transport on atmospheric pressure silicon epitaxy by SiH4 pyrolysis is planned. Experimentally, flow regimes in which free convective transport contributes to the Chemical Vapor Deposition (CVD) process will be identified, and, for these conditions, the flow and deposition process will be characterized. Specifically, this will include measurements of three dimensional temperature variations using in situ Rayleigh scattering, gas phase composition profiles using laser absorption and fluorescence techniques, and deposition rates and defect densities. Subsequently, the free convective transport contribution to the CVD process will be minimized and/or altered while leaving deposition chemistry unaltered, and the characterization will be repeated. Based on these analyses, the effects of gravitationally-induced transport on atmospheric pressure CVD will be assessed.

Charter D. Stinespring↗

Highly oriented Tl2Ba2Ca2Cu3O10 thin films by pulsed laser evaporation

Superconducting thin films on MgO (100) substrates with nearly pure Tl2Ba2Ca2Cu3O10 (2:2:2:3) phase using pulsed laser evaporation and postannealing have been fabricated. The films had c axes perpendicular to the substrates. Superconducting films with onset temperatures of 125 K and zero resistance at 110 K were obtained. X-ray microprobe fluorescence measurements indicate that a typical composition of films is Tl(0.66)Ba(1.77)Ca(1.46)Cu3O(x) which is low in Tl compared to that expected for the 2:2:2:3 phase. A typical grain size is greater than 10 microns revealed by scanning electron microscopy.

Liou, S. H.↗

The mini-CIDEX GC/IMS: Analysis of cometary ice and dust

Comets are recognized as among the most scientifically important objects in the solar system. They are presumed relics of the early primitive material in the solar nebula and are believed to have provided a general enrichment of volatiles to the inner solar system. The Cometary Coma Chemical Composition (C4) Mission, a proposed Discovery-Class Mission, will analyze materials released into the coma, providing information leading to the understanding of the chemical composition and make-up of the cometary nucleus. As one of two scientific instruments in the C4 spacecraft, an advanced and streamlined version of the Cometary Ice and Dust Experiment (CIDEX), a mini-CIDEX, will employ an X-Ray Fluorescence (XRF) spectrometer to determine bulk elemental composition of cometary dust grains and a Gas Chromatograph/Ion Mobility Spectrometer (GC/IMS) for determination of the molecular composition of dust and ices following stepwise pyrolysis and combustion. A description of the mini-CIDEX IMS will be provided as well as data from analyses conducted using the mini-CIDEX breadboard instrument.

Kojiro, Daniel R.↗

In Situ Resource Utilization (ISRU) on the Moon: Moessbauer Spectroscopy as a Process Monitor for Oxygen Production

Essential consumables like oxygen must to be produced from materials on the lunar surface to enable a sustained, long-term presence of humans on the Moon. The Outpost Precursor for ISRU and Modular Architecture (OPTIMA) field test on Mauna Kea, Hawaii, facilitated by the Pacific International Space Center for Exploration Systems (PISCES) of the University of Hawaii at Hilo, was designed to test the implementation of three hardware concepts to extract oxygen from the lunar regolith: Precursor ISRU Lunar Oxygen Testbed (PILOT) developed by Lockheed Martin in Littleton, CO; Regolith & Environmental Science and Oxygen & Lunar Volatiles Extraction (RESOLVE) developed at the NASA Kennedy Space Center in Cape Canaveral, FL; and ROxygen developed at the NASA Johnson Space Center in Houston, TX. The three concepts differ in design, but all rely on the same general principle: hydrogen reduction of metal cations (primarily Fe2+) bonded to oxygen to metal (e.g., Fe0) with the production of water. The hydrogen source is residual hydrogen in the fuel tanks of lunar landers. Electrolysis of the water produces oxygen and hydrogen (which is recycled). We used the miniaturized M ssbauer spectrometer MIMOS II to quantify the yield of this process on the basis of the quantity of Fe0 produced. Iron M ssbauer spectroscopy identifies iron-bearing phases, determines iron oxidation states, and quantifies the distribution of iron between mineral phases and oxidation states. The oxygen yield can be calculated by quantitative measurements of the distribution of Fe among oxidation states in the regolith before and after hydrogen reduction. A M ssbauer spectrometer can also be used as a prospecting tool to select the optimum feedstock for the oxygen production plants (e.g., high total Fe content and easily reduced phases). As a demonstration, a MIMOS II backscatter spectrometer (SPESI, Germany) was mounted on the Cratos rover (NASA Glenn Research Center in Cleveland, OH), which is one of several rover concepts designed to excavate and transfer regolith to the stationary hydrogen reduction plants. Spaceflight versions of the MIMOS II are part of the instrument payloads of NASA s Mars Exploration Rovers and still operating five years after landing on the surface of the planet. MIMOS II was also selected for Phobos-Grunt, a Russian sample return mission to the martian moon Phobos scheduled to launch in 2009, and ESA s ExoMars rover, an exobiology mission scheduled to launch in 2013. An advanced version of the instrument is currently under development. A new detector system with a higher energy resolution will not only reduce the necessary measurement time considerably, but also allow the simultaneous acquisition of an X-ray fluorescence spectrum to determine the elemental composition of samples.

Morris, R.V.↗

A Large Drift Detector Array Lunar Orbiter Spectrometer

Measurement of-rays from the surface of objects can tell us about the chemical composition. Absorption of radiation causes characteristic fluorescence from material being irradiated. By measuring the spectrum ofthe radiation and identifying lines in the spectrum, the emitting element (s) can be identified.

Gaskin, Jessica A.↗

A Radiation-Hard Silicon Drift Detector Array for Extraterrestrial Element Mapping

Measurement of x-rays from the surface of objects can tell us about the chemical composition Absorption of radiation causes characteristic fluorescence from material being irradiated. By measuring the spectrum of the radiation and identifying lines in the spectrum, the emitting element (s) can be identified. This technique works for any object that has no absorbing atmosphere and significant surface irradiation : Our Moon, the icy moons of Jupiter, the moons of Mars, the planet Mercury, Asteroids and Comets

Gaskin, Jessica↗