Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flowmeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The impact assessment of eccentric installation and roughness change in piping on the orifice flow measurement

In orifice flowmeters used in nuclear power plants, requirements for the inner surface roughness of upstream piping and eccentric installation exist depending on certain standards. If these cannot be satisfied based on the installation condition, an appropriate error margin must be considered, although this remains to be clarified. In this research, quantitative data concerning the relative error of orifice flowmeters were obtained during experiments with the parameters of the inner surface roughness of upstream piping and the installation eccentricity of the orifice hole. The maximum Reynolds number of the experimental facility is about 1.6x10{sup 6}. In orifice flowmeters, the flow rate is calculated based on the differential pressure between upstream and downstream orifices and the peculiar discharge coefficient C. The latter value shows an upward trend with increasing roughness of piping, while change of 0.3% of C was observed in terms of roughness (case 2), which approaches the limits of the JIS standard. With significant roughness (Case 3) that exceeds five times the JIS standard, C is shown to have increased by about 1%. No influence was observed by varying the direction of eccentric installation, hence this was fixed and the amount of eccentricity was considered. Change in C of about 0.25% was observed when around twice the standard level of eccentricity was applied. The error margin data under conditions exceeding the JIS standard for the orifice flowmeter was obtained. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal Hydraulic Experimental Test Article (FY2020 Status Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA will be installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2. The design work for the facility has been completed. Since the FY19 THETA status report, the THETA primary system components have been assembled and tested using de-ionized water. Some results of this testing at select Richardson and Reynolds numbers are included herein. The custom THETA sodium flowmeter (permanent magnet submersible sodium flowmeter) has been built and calibrated using sodium in an auxiliary facility against a NIST traceable vortex shedder type flowmeter. The permanent magnet flowmeter showed excellent performance, following the theoretical equation for measured voltage quite well, with an error < 3.5% at flow rates ranging from 3-24 GPM at temperatures up to 400 °C. The secondary sodium system for heat rejection from intermediate heat exchanger has been analyzed according to ASME code. All secondary side piping, fittings and a U-stamped air-to-sodium heat exchanger have been procured.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sodium Hydrogen Sensor and Acoustic Flow Sensor Development

This report documents the development of diffusion-type hydrogen meters (DTHMs) as part of a steam generator leak detection system (SGLDS) of sodium-cooled fast reactors (SFR) and the demonstration of the capabilities of acoustic flowmeters, including a commercial UTFM (Flexim FLUXUS F721) and an Argonne HT acoustic flowmeter running on shear-to-longitudinal mode. It also evaluates two Argonne permanent magnet flowmeters (PMFMs).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Upgrade of the gas flow control system of the resistive current leads of the LHC inner triplet magnets: Simulation and experimental validation

The 600 A and 120 A circuits of the inner triplet magnets of the Large Hadron Collider are powered by resistive gas cooled current leads. The current solution for controlling the gas flow of these leads has shown severe operability limitations. In order to allow a more precise and more reliable control of the cooling gas flow, new flowmeters will be installed during the first long shutdown of the LHC. Because of the high level of radiation in the area next to the current leads, the flowmeters will be installed in shielded areas located up to 50 m away from the current leads. The control valves being located next to the current leads, this configuration leads to long piping between the valves and the flowmeters. In order to determine its dynamic behaviour, the proposed system was simulated with a numerical model and validated with experimental measurements performed on a dedicated test bench.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method and apparatus for controlling mass flow rate of recycled anode tail gas in solid oxide fuel cell system

In an SOFC stack system, a reformer supplies reformate to the stack. An anode tail gas portion is recycled into the reformer. An inline flowmeter indicates an apparent recycle flow rate. A map of anode tail gas composition as a function of fuel utilization efficiency U, reformer oxygen/carbon ratio O:C, and recycle percentage R is generated on a laboratory test bed at various recycle rates and fuel utilization rates. Compositions are sent through a flowmeter and a Coriolus mass flowmeter provide a Coriolus flow and sensor voltage function across the various compositions and flow rates to create an average curve and an average (reference) voltage at a given flow. A scale factor Z is calculated and used to determine a scaled sensor voltage X for use in an average flow polynomial curve fit equation to calculate tail gas mass flow rate at any flow value indicated by the flow meter.

30 DIRECT ENERGY CONVERSION↗

Liquid Metal Diagnostics

Liquid metal (LM) plasma-facing components (PFCs) (LM-PFCs) within next-generation fusion reactors are expected to enhance plasma confinement, facilitate tritium breeding, improve reactor thermal efficiency, and withstand large heat and particle fluxes better than solid components made from tungsten, molybdenum, or graphite. Some LM divertor concepts intended for long-pulse operation at >20 MW/m 2 incorporate thin (~1 cm), fast-moving (~5 to 10 m/s), free-surface flows. Such systems will require a range of diagnostics to monitor and control the velocity, flow depth, temperature, and impurity concentration of the LM. As such, this paper will highlight technologies developed for the fission and casting/metallurgical industries that can be adapted to meet the needs of LM-PFC research. This paper is divided into four major parts. The first part will look at noncontact flowmeter technologies that are suitable for high-temperature alkali metal systems. These technologies include rotating Lorentz-force flowmeters for bulk flow rate measurements and particle tracking techniques for surface velocity measurements. Second, this paper will detail the operation of a new inductive level sensor that can be used within free-surface LM-PFCs. This robust level sensor can be mounted below the substrate that supports the LM, so it is simple to install and is protected from the damaging conditions inside a fusion reactor. It has been shown that this level sensor can be calibrated using either numerical or experimental techniques. Third, distributed temperature sensors based on fiber-optic technologies will be discussed. This advanced measurement technique provides temperature data with high spatial resolution and has recently been successfully tested in LM systems. Last, diagnostics to measure impurity concentration, such as electrochemical cells, plugging meters, and spectroscopic systems, will be addressed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Estimating irrigation water use from remotely sensed evapotranspiration data: Accuracy and uncertainties at field, water right, and regional scales

Irrigated agriculture is the dominant user of water globally, but most water withdrawals are not monitored or reported. As a result, it is largely unknown when, where, and how much water is used for irrigation. Here, we evaluated the ability of remotely sensed evapotranspiration (ET) data, integrated with other datasets, to calculate irrigation water withdrawals and applications in an intensively irrigated portion of the United States. We compared irrigation calculations based on an ensemble of satellite-driven ET models from OpenET with reported groundwater withdrawals from hundreds of farmer irrigation application records and a statewide flowmeter database at three spatial scales (field, water right group, and management area). At the field scale, we found that ET-based calculations of irrigation agreed best with reported irrigation when the OpenET ensemble mean was aggregated to the growing season timescale (bias = 1.6–4.9%, R 2 = 0.53–0.74), and agreement between calculated and reported irrigation was better for multi-year averages than for individual years. At the water right group scale, linking pumping wells to specific irrigated fields was the primary source of uncertainty. At the management area scale, calculated irrigation exhibited similar temporal patterns as flowmeter data but tended to be positively biased with more interannual variability. Disagreement between calculated and reported irrigation was strongly correlated with annual precipitation, and calculated and reported irrigation agreed more closely after statistically adjusting for annual precipitation. The selection of an ET model was also an important consideration, as variability across ET models was larger than the potential impacts of conservation measures employed in the region. From these results, we suggest key practices for working with ET-based irrigation data that include accurately accounting for changes in soil moisture, deep percolation, and runoff; careful verification of irrigated area and well-field linkages; and conducting application-specific evaluations of uncertainty.

59 BASIC BIOLOGICAL SCIENCES↗

Thermal Hydraulic Experimental Test Article (FY21 Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA has been installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2 and Figure 3. Since the FY20 THETA status report, further water shakedown testing was performed, some final welding modifications were performed, all system components were sanitized, dry assembled, and commissioned. The THETA submersible electromagnetic flowmeter was welded closed to hermetically seal internal components from sodium followed by a helium leak check for the final time. Following installation of THETA into vessel #4, all data acquisition and control systems were brought online and commissioned at room temperature in the argon gas space of the empty vessel. The vessel zone 1 heaters were reinstalled and the flange was then insulated. The vessel 4 heaters were brought to a temperature of 100 °C and the THETA pump was jogged at 600 RPM to ensure it was functioning correctly. The secondary, AC Conduction based electromagnetic pump from CMI Novacast (product number CA-15) was ordered and will be delivered in late calendar year 2021. The custom designed permanent magnet based secondary flowmeter was designed, a drawing package and manufacturing specification created and quote requested from a machine shop. The intermediate heat exchanger design was completed and a drawing package is currently in progress. During the middle of calendar year 2021 the Building 308 sodium scrubber system was shut down in order to replaced some corroded piping and facilitate improvements on the system, thus requiring the sodium in METL to remain frozen. This has imposed a delay in filling vessel 4 with sodium to begin THETA testing. Sodium testing is expected to begin in early fiscal year 2022 as all THETA primary systems are operational.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Utah FORGE: Well 14-2 Logs and Data from Roosevelt Hot Spring Area

This is a compilation of logs and data from Well 14-2 in the Roosevelt Hot Springs area in Utah. This well is also in the Utah FORGE study area. Data includes: flowmeter survey (1989), geochemistry (1977-1978, 1977-1983), injection test data (1979, 1982), and spinner surveys (1989, 1985-1986). Logs include: borehole compensated sonic and gamma ray (600'-6112'), borehole geometry and gamma ray (50'-4829'), caliper (0'-1720'), compensated neutron formation density (600'-6121'), induction electric (650'-6118'), mud log (79'-6100'), steam injection survey (50'-1175'), subsurface pressure surveys (0'-6087'), and subsurface temperature surveys (0'-6106'). The file is in a compressed .zip format and there is a data inventory table (Excel spreadsheet) in the root folder that is a guide to the data that is accessible in subfolders.

14-2↗

Three-Dimensional Bayesian Geostatistical Aquifer Characterization at the Hanford 300 Area using Tracer Test Data

Tracer testing under natural or forced gradient flow holds the potential to provide useful information for characterizing subsurface properties, through monitoring, modeling and interpretation of the tracer plume migration in an aquifer. Non-reactive tracer experiments were conducted at the Hanford 300 Area, along with constant-rate injection tests and electromagnetic borehole flowmeter (EBF) profiling. A Bayesian data assimilation technique, the method of anchored distributions (MAD) [Rubin et al., 2010], was applied to assimilate the experimental tracer test data with the other types of data and to infer the three-dimensional heterogeneous structure of the hydraulic conductivity in the saturated zone of the Hanford formation. In this study, the Bayesian prior information on the underlying random hydraulic conductivity field was obtained from previous field characterization efforts using the constant-rate injection tests and the EBF data. The posterior distribution of the conductivity field was obtained by further conditioning the field on the temporal moments of tracer breakthrough curves at various observation wells. MAD was implemented with the massively-parallel three-dimensional flow and transport code PFLOTRAN to cope with the highly transient flow boundary conditions at the site and to meet the computational demands of MAD. A synthetic study proved that the proposed method could effectively invert tracer test data to capture the essential spatial heterogeneity of the three-dimensional hydraulic conductivity field. Application of MAD to actual field data shows that the hydrogeological model, when conditioned on the tracer test data, can reproduce the tracer transport behavior better than the field characterized without the tracer test data. This study successfully demonstrates that MAD can sequentially assimilate multi-scale multi-type field data through a consistent Bayesian framework.

54 ENVIRONMENTAL SCIENCES↗

A high sensitivity fiber optic macro-bend based gas flow rate transducer for low flow rates: Theory, working principle, and static calibration

A novel fiber optic macro-bend based gas flowmeter for low flow rates is presented. Theoretical analysis of the sensor working principle, design, and static calibration were performed. The measuring system consists of: an optical fiber, a light emitting diode (LED), a Quadrant position sensitive Detector (QD), and an analog electronic circuit for signal processing. The fiber tip undergoes a deflection in the flow, acting like a cantilever. The consequent displacement of light spot center is monitored by the QD generating four unbalanced photocurrents which are function of fiber tip position. The analog electronic circuit processes the photocurrents providing voltage signal proportional to light spot position. A circular target was placed on the fiber in order to increase the sensing surface. Sensor, tested in the measurement range up to 10 l min{sup -1}, shows a discrimination threshold of 2 l min{sup -1}, extremely low fluid dynamic resistance (0.17 Pa min l{sup -1}), and high sensitivity, also at low flow rates (i.e., 33 mV min l{sup -1} up to 4 l min{sup -1} and 98 mV min l{sup -1} from 4 l min{sup -1} up to 10 l min{sup -1}). Experimental results agree with the theoretical predictions. The high sensitivity, along with the reduced dimension and negligible pressure drop, makes the proposed transducer suitable for medical applications in neonatal ventilation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Conceptual Lead Cartridge Design to Perform Irradiation Experiments in VTR

This paper seeks to introduce the latest design of the Extended Length Test Assembly–Cartridge Lead (ELTA-CL) with associated thermal-hydraulic (TH) assessment and related experiment activities to support the critical component development performed by the ELTA-CL team (Los Alamos National Laboratory, Westinghouse Electric Company, and the University of New Mexico). The goal of the ELTA-CL program is to develop and validate an experimental capability to perform irradiation experiments in the Versatile Test Reactor (VTR) addressing Lead Fast Reactor (LFR) technology gaps, in support of the commercial development of advanced lead-cooled fast reactor concepts. Through a design maturation process and parametric study, a conceptual design is proposed to meet the requirements for material and corrosion testing. Thermal-hydraulic characteristics for the conceptual design at desired operating conditions are assessed with systems-level (one-dimensional) and computational fluid dynamics (three-dimensional) simulations. Along with the conceptual design work, experimental activities for the development of critical components such as the pump and flowmeter are undertaken. From both the modeling study and the experimental results, the design requirements of the Phase 1 ELTA-CL (e.g., 500°C and 2 m/s) are achievable with the current conceptual design. Additional design improvements and safety assessments at both steady-state and transient conditions for the final ELTA-CL design will be pursued.

42 ENGINEERING↗

River-Induced Flow Dynamics in Long-Screen Wells and Impact on Aqueous Samples

Previously published field investigations and modeling studies have demonstrated the potential for sample bias associated with vertical wellbore flow in conventional monitoring wells constructed with long-screened intervals. This paper builds on the existing body of literature by 1) demonstrating the utility of continuous (i.e., hourly measurements for ~ one month) ambient wellbore flow monitoring and 2) presenting results from a field experiment where relatively large wellbore flows (up to 4 LPM) were induced by aquifer hydrodynamics associated with a fluctuating river boundary located approximately 250 m from the test well. The observed vertical wellbore flows were strongly correlated with fluctuations in river stage, alternating between upward and downward flow throughout the monitoring period in response to changes in river stage. Continuous monitoring of ambient wellbore flows using an Electromagnetic Borehole Flowmeter (EBF) allowed these effects to be evaluated in concert with continuously monitored river-stage elevations (hourly) and aqueous uranium concentrations (daily) in a long-screen well and an adjacent multi-level well cluster. This study demonstrates that when contaminant concentrations within the aquifer vary significantly over the depth interval interrogated, even for screen lengths as small as 7.6 m, river-induced vertical wellbore flow can result in variations in measured concentration that nearly encompass the full range of variation in aquifer contaminant concentration with depth. An approach to mitigate these effects based on increasing hydraulic resistance within the wellbore by installing an inflatable packer was evaluated and was demonstrated to reduce vertical wellbore flows.

54 ENVIRONMENTAL SCIENCES↗

Vertical Wellbore Flow Monitoring for Assessing Spatial and Temporal Flow Relationships with a Dynamic River Boundary

A useful tool for identifying the temporal and spatial ambient wellbore flow relationships near a dynamic river boundary is to continuously monitor ambient vertical wellbore flow with an electromagnetic borehole flowmeter (EBF). This is important because the presence of the wellbore can result in significant mixing or exchange of groundwater vertically across the aquifer. Mixing or exchanging groundwater within the well-screen section can have significant impacts on the distribution of contaminants within the aquifer and adverse effects on the representativeness of groundwater samples collected from the monitoring well. EBF monitoring data collected from long, fully screened wells at Hanford’s 300-Area Integrated Field Research Challenge (IFRC) site, located ~260 to 290 m from the Columbia River, demonstrate that ambient vertical wellbore flow exhibits both a positive (direct) and inverse temporal relationship with periodic river-stage fluctuations over short distances. The ambient flow monitoring wells fully penetrate a highly transmissive unconfined aquifer that consists of unconsolidated coarse sediments of the Hanford formation. The spatial distribution of ambient vertical wellbore flows across the IFRC’s ~2,200 m2 well-field size indicates two general regions of inverse ambient wellbore flow behavior. The western region of the IFRC site is characterized by ambient vertical wellbore flows that are positively related to river-stage fluctuations. In contrast, the eastern region of the site exhibits ambient wellbore flows that are inversely related to river-stage fluctuations. The cause of this opposite relationship between ambient wellbore flows and river-stage changes is not completely understood; however, the positive relationships appear to be associated with high-energy Hanford formation flood deposits. These flood deposits have a well-defined northwest-southeast trend and are believed to coincide with a local paleochannel. This local paleochannel bisects the site and connects to larger, more regionally developed flood paleochannels that laterally connect to the north and south across the 300 Area and the Hanford Site. The inverse relationships are attributed to an erosional, subsurface high in the Hanford/Ringold formation contact between the IFRC site and the Columbia River. Under these complex hydrogeologic and hydrodynamic conditions, the behavior of ambient vertical wellbore flow in monitoring wells near a dynamic river boundary can have important implications for collecting groundwater-quality samples, for contributing to contaminant distribution and transport within an aquifer system, and for implementing effective remediation strategies.

54 ENVIRONMENTAL SCIENCES↗

Objective assessment in digital images of skin erythema caused by radiotherapy

Purpose: Skin toxicity caused by radiotherapy has been visually classified into discrete grades. The present study proposes an objective and continuous assessment method of skin erythema in digital images taken under arbitrary lighting conditions, which is the case for most clinical environments. The purpose of this paper is to show the feasibility of the proposed method. Methods: Clinical data were gathered from six patients who received carbon beam therapy for lung cancer. Skin condition was recorded using an ordinary compact digital camera under unfixed lighting conditions; a laser Doppler flowmeter was used to measure blood flow in the skin. The photos and measurements were taken at 3 h, 30, and 90 days after irradiation. Images were decomposed into hemoglobin and melanin colors using independent component analysis. Pixel values in hemoglobin color images were compared with skin dose and skin blood flow. The uncertainty of the practical photographic method was also studied in nonclinical experiments. Results: The clinical data showed good linearity between skin dose, skin blood flow, and pixel value in the hemoglobin color images; their correlation coefficients were larger than 0.7. It was deduced from the nonclinical that the uncertainty due to the proposed method with photography was 15%; such an uncertainty was not critical for assessment of skin erythema in practical use. Conclusions: Feasibility of the proposed method for assessment of skin erythema using digital images was demonstrated. The numerical relationship obtained helped to predict skin erythema by artificial processing of skin images. Although the proposed method using photographs taken under unfixed lighting conditions increased the uncertainty of skin information in the images, it was shown to be powerful for the assessment of skin conditions because of its flexibility and adaptability.

60 APPLIED LIFE SCIENCES↗

The Development of an INL Capability for High Temperature Flow, Heat Transfer, and Thermal Energy Storage with Applications in Advanced Small Modular Reactors, High Temperature Heat Exchangers, Hybrid Energy Systems, and Dynamic Grid Energy Storage C

The overall goal of this project is to support Idaho National Laboratory in developing a new advanced high temperature multi fluid multi loop test facility that is aimed at investigating fluid flow and heat transfer, material corrosion, heat exchanger characteristics and instrumentation performance, among others, for nuclear applications. Specifically, preliminary research has been performed at The Ohio State University in the following areas: 1. A review of fluoride molten salts’ characteristics in thermal, corrosive, and compatibility performances. A recommendation for a salt selection is provided. Material candidates for both molten salt and helium flow loop have been identified. 2. A conceptual facility design that satisfies the multi loop (two coolant loops [i.e., fluoride molten salts and helium]) multi purpose (two operation modes [i.e., forced and natural circulation]) requirements. Schematic models are presented. The thermal hydraulic performances in a preliminary printed circuit heat exchanger (PCHE) design have been estimated. 3. An introduction of computational methods and models for pipe heat loss analysis and cases studies. Recommendations on insulation material selection have been provided. 4. An analysis of pipe pressure rating and sizing. Preliminary recommendations on pipe size selection have been provided. 5. A review of molten fluoride salt preparation and chemistry control. An introduction to the experience from the Molten Salt Reactor Experiment at Oak Ridge National Laboratory has been provided. 6. A review of some instruments and components to be used in the facility. Flowmeters and Grayloc connectors have been included. This report primarily presents the conclusions drawn from the extensive review of literatures in material selections and the facility design progress at the current stage. It provides some useful guidelines in insulation material and pipe size selection, as well as an introductory review of facility process and components.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Aethalometer™ Instrument Handbook

The Aethalometer is an instrument that provides a real-time readout of the concentration of “Black” or “Elemental” carbon aerosol particles (BC or E) in an air stream (see Figure 1 and Figure 2). It is a self-contained instrument that measures the rate of change of optical transmission through a spot on a filter where aerosol is being continuously collected and uses the information to calculate the concentration of optically absorbing material in the sampled air stream. The instrument measures the transmitted light intensities through the “sensing” portion of the filter, on which the aerosol spot is being collected, and a “reference” portion of the filter as a check on the stability of the optical source. A mass flowmeter monitors the sample air flow rate. The data from these three measurements is used to determine the mean BC content of the air stream.

54 ENVIRONMENTAL SCIENCES↗