Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow meter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Bidirectional flow meter

Device provides wide variety of flow metering on a volume demand basis, in either of two directions. Flow is controlled by number, locations, and sizes of orifices and O-rings. Device is useful in pneumatic or hydraulic systems where valve sequence and timing functions vary from point to point.

Sutton, R. F.↗

Performance of Thermal Mass Flow Meters in a Variable Gravitational Environment

The performance of five thermal mass flow meters, MKS Instruments 179A and 258C, Unit Instruments UFM-8100, Sierra Instruments 830L, and Hastings Instruments HFM-200, were tested on the KC-135 Reduced Gravity Aircraft in orthogonal, coparallel, and counterparallel orientations relative to gravity. Data was taken throughout the parabolic trajectory where the g-level varied from 0.01 to 1.8 times normal gravity. Each meter was calibrated in normal gravity in the orthogonal position prior to flight followed by ground testing at seven different flow conditions to establish a baseline operation. During the tests, the actual flow rate was measured independently using choked-flow orifices. Gravitational acceleration and attitude had a unique effect on the performance of each meter. All meters operated within acceptable limits at all gravity levels in the calibrated orthogonal position. However, when operated in other orientations, the deviations from the reference flow became substantial for several of the flow meters. Data analysis indicated that the greatest source of error was the effect of orientation, followed by the gravity level. This work emphasized that when operating thermal flow meters in a variable gravity environment, it is critical to orient the meter in the same direction relative to gravity in which it was calibrated. Unfortunately, there was no test in normal gravity that could predict the performance of a meter in reduced gravity. When operating in reduced gravity, all meters indicated within 5 percent of the full scale reading at all flow conditions and orientations.

Brooker, John E.↗

Fluid flow meter for measuring the rate of fluid flow in a conduit

A tube fluid flow rate meter consists of a reservoir divided by flexible diaphragm into two separate isolated compartments. The incoming and outgoing tubes open into the compartments. The orifice is sized to allow maximum tube fluid flow. Opposing compression springs are secured within the two compartments on opposite sides of the orifice to maintain orifice position when the tube fluid pressure is zero. A tapered element is centered in, and extends through the orifice into the compartment, leaving an annular opening between the element and the perimeter of the oriface. The size varies as the diaphragm flexes with changes in the tube fluid pressure to change the fluid flow through the opening. The light source directs light upon the element which in turn scatters the light through the opening into the compartment. The light detector in the compartment senses the scattered light to generate a signal indicating the amount of fluid.

White, P. R.↗

Balanced Flow Metering and Conditioning: Technology for Fluid Systems

Revolutionary new technology that creates balanced conditions across the face of a multi-hole orifice plate has been developed, patented and exclusively licensed for commercialization. This balanced flow technology simultaneously measures mass flow rate, volumetric flow rate, and fluid density with little or no straight pipe run requirements. Initially, the balanced plate was a drop in replacement for a traditional orifice plate, but testing revealed substantially better performance as compared to the orifice plate such as, 10 times better accuracy, 2 times faster (shorter distance) pressure recovery, 15 times less acoustic noise energy generation, and 2.5 times less permanent pressure loss. During 2004 testing at MSFC, testing revealed several configurations of the balanced flow meter that match the accuracy of Venturi meters while having only slightly more permanent pressure loss. However, the balanced meter only requires a 0.25 inch plate and has no upstream or downstream straight pipe requirements. As a fluid conditioning device, the fluid usually reaches fully developed flow within 1 pipe diameter of the balanced conditioning plate. This paper will describe the basic balanced flow metering technology, provide performance details generated by testing to date and provide implementation details along with calculations required for differing degrees of flow metering accuracy.

Kelley, Anthony R.↗

Preliminary Design Study for an Eddy Current Flow Meter for Versatile Test Reactor

The eddy current flow meter (ECFM) serves the purpose of monitoring velocities and temperatures of conductive liquid coolant surrounding nuclear reactor cells. The ECFM can also detect voids in two-phase liquid metal flows. Measurement of this flow in reactor cells can greatly improve the accuracy of the empirical formulas used for fluid dynamics near the reactor core, as well as, aid in mapping any non-uniformities in fluid flow, its temperature estimation and phase. With modeling and experimental verification, an extensible ECFM for multiple facilities and environments can lead to an understanding of the liquid coolant flow; while saving cost of calibration and development. This can be done by characterizing the ECFM performance based on its parameters and then optimizing a sensor for a given use case. Simulation results using an ECFM and an aluminum rod medium are presented and discussed herein. Additionally, liquid metal simulations for Mercury and Galinstan will compare the ECFM behavior for different liquid velocities and excitation frequencies. After sensor calibration curves are generated and experimentally verified, ECFMs can be developed and deployed using the model introduced.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Eddy current flow meter model validation with a moving solid rod*

We report that the eddy current flow meter (ECFM) has been used to measure velocities and temperatures of conductive flows, such as liquid metal flows in a nuclear fission reactor. The goal of this paper is to develop a finite element electromagnetic model that can characterize the ECFM sensor performance and validate this finite element model with detailed velocity measurements of a controlled, well-characterized moving conductive solid rod. Both measurements and modeling were performed for various parameters that are important for ECFM performance such as rod velocity, rod material, ECFM sensor coil length, number of sensor coils, applied alternating current (AC) current amplitude, and applied ECFM AC frequency. For all parametric scans, the measurement and modeling agree well in both magnitude and trend. The normalized root-mean-square error between measurement and modeling is less than 10% for all cases. These results suggest that electromagnetic modeling could eventually be used to cost-effectively design future ECFM sensors in arbitrary geometry for more challenging applications such as liquid metal nuclear fission reactors.

47 OTHER INSTRUMENTATION↗

Electromagnetic Flow Meter Having a Driver Circuit Including a Current Transducer

An electromagnetic flow meter (EMFM) accurately measures both the complete flow rate and the dynamically fluctuating flow rate of a fluid by applying a unipolar DC voltage to excitation coils for a predetermined period of time, measuring the electric potential at a pair of electrodes, determining a complete flow rate and independently measuring the dynamic flow rate during the "on" cycle of the DC excitation, and correcting the measurements for errors resulting from galvanic drift and other effects on the electric potential. The EMFM can also correct for effects from the excitation circuit induced during operation of the EMFM.

Karon, David M.↗

Solvent Dispersion and Flow Meter Calculation Results

Savannah River National Laboratory (SRNL) found that the dispersion numbers for the six combinations of CSSX:Next Generation Solvent (NGS) “blend” and pure NGS versus salt solution, caustic wash, and strip aqueous solutions are all good. The dispersion numbers are indications of processability with centrifugal contactors. A comparison of solvent physical and thermal properties shows that the Intek™ solvent flow meter in the plant has a reading biased high versus calibrated flow when NGS is used, versus the standard CSSX solvent. The flow meter, calibrated for CSSX solvent, is predicted to read 2.8 gpm of NGS in a case where the true flow of NGS is 2.16 gpm.

42 ENGINEERING↗

Eddy Current Flow Meter Measurements and Modeling Validation

The goal of the eddy current flow meter (ECFM) is to monitor velocities and temperatures of conductive liquid metals. The ECFM can also detect voids in two-phase liquid metal flows. Measurement of these flows can greatly improve the accuracy of the empirical formulas used for fluid dynamics near the reactor core and aid in mapping any non-uniformities in fluid flow such as estimates of temperature and phase. While the eventual goal is to develop the ECFM for the liquid sodium surrounding the Versatile Test Reactor (VTR) core, this report focuses on modeling and experimental validation of ECFM for a moving solid test rod and for liquid mercury in the Target Test Facility (TTF) flow loop to better understand and further develop ECFM measurement capabilities by validating model predictions with benchmark experiments. Eventually the models could be used to design and optimize future ECFMs for specific applications such as monitoring flow within the VTR pool.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Mass-Flow-Meter Leak-Testing System

Improved leak-testing system incorporates mass-flow meter as primary sensor for measurement of leakage rate. System easier to use and more reliable and enables leak tests to be completed in less time. Produces test data more plentiful, more accurate, and better suited to leak detection and diagnosis. Operates over range of test conditions, including pressures from atmospheric to 1,000 psi, temperatures from 50 to 120 degrees F and volumes from less than 1 in.(sup3) to 22 in.(sup3). Sensitive enough to measure absorbed gas seeping from O-ring seals after test pressure released.

Sorensen, Eric B.↗

Pressure sensitive gas flow meter

Regulator, which increases flow area in discrete steps as upstream pressure falls, maintains steady flow rate of gas as the supply pressure from storage system decreases.

Hallum, C. E.↗

Demonstration of Microwave Resonant Cavity Transducer Performance in Fluid Flow Sensing: Development of Sensor Performance Model of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. To validate sensor physics, we have performed proof-of-principle test of flow sensing in water. For this test, we have developed a cylindrical resonator for K-band, which was machined from brass. The cavity was excited through WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder. To increase the spectral signal visibility, we developed a signal processing method for baseline subtraction. A flow loop for proof-of-principle test of transducer performance in water was assembled. A commercial flow meter was installed in the loop for reference measurements. Cylindrical cavity was excited in the TEM 011 mode with resonant frequency f ≈ 17.8GHz. Frequency shift of cavity spectral response was obtained by gradually increasing water flow rate from 0 to 60gpm. Corresponding monotonic increase of resonant frequency shift by several MHz was observed.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗