Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “floors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The Short Life of Upvalley Wind in a High‐Altitude Valley in the Colorado Rocky Mountains

Thermally driven upvalley (UV) wind in the upper East River Valley in the Colorado Rocky Mountains often unexpectedly stops in midmorning and reverses back to downvalley (DV) wind. We use a comprehensive observational data set for a nearly two‐year long period to analyze the wind system and boundary layer evolution in this high‐altitude valley and determine the reason for this early wind reversal. Days with short UV wind predominantly occur during the warm season when the valley floor is free of snow and the convective boundary layer (CBL) grows well above the height of the surrounding ridges. UV wind persists throughout the day only on a few days during the warm season. We link differences in valley wind evolution to wind direction at upper levels at and above ridge height and propose forced channeling mechanisms to describe coupling between valley and upper‐level wind when the CBL grows above ridge height. The frequency distribution of upper‐level wind direction is such that channeling in the DV direction is favored, which explains the predominance of days with short UV wind. The deep CBL is supported by the presence of a deep weakly stably stratified residual layer with high aerosol content, which is regularly present over the mountain range during the warm season. On days when the CBL does not grow above ridge height, for example, when the valley floor is covered by snow, thermally driven UV wind is able to persist throughout the day independent of upper‐level wind direction.

54 ENVIRONMENTAL SCIENCES↗

Infrared thermography NDT for in-situ defect detection in sandwich composite panel manufacturing

Composite manufacturing presents numerous challenges, as defects can arise from various sources throughout the process. In sandwich composite structures, the integration of a foam core introduces additional complexity and increases the likelihood of defect formation like delamination. To mitigate these issues and reduce the risk of future structural failures, in-situ monitoring during manufacturing is essential. This study investigates infrared (IR) thermography as a non-destructive technique for detecting manufacturing defects in foam-core sandwich composite panels under thermally excited conditions representative of in-situ processing. A stationary FLIR A8590 IR camera (640 × 512 pixels, 30Hz, 17mm lens, 9 ft stand-off distance) was used to monitor prefabricated panels subjected to controlled external heating simulating compression molding and resin cure exotherm. Interlaminar delamination defects with characteristic sizes ranging from 0.25 × 0.25in² to 5 × 5in² produced measurable surface temperature depressions of approximately 4–10°C during transient cooling, exceeding the effective noise floor of the camera by more than two standard deviations. Thicker laminates exhibited prolonged defect detectability windows due to increased thermal diffusion time. In contrast, embedded Teflon inclusions generated weak thermal contrasts of ≤ 3°C, approaching the measurement noise floor, due to limited thermal property contrast with the surrounding glass fiber composite. These results establish quantitative detectability limits for stationary thermographic inspection of sandwich composite panels under manufacturing-representative thermal cycles.

Barakat, Abdallah [ORNL] (ORCID:0000000296141398)↗

AmeriFlux FLUXNET-1F US-CLF Cole Farm

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-CLF Cole Farm. This is the FLUXNET version of the carbon flux data for the site US-CLF Cole Farm produced by applying the standard ONEFlux (1F) software. Site Description - The Cole Farm catchment (0.65km2) is located ~ 4 km southwest of the Shale Hills site, draining orthogonally to a syncline axis of the Wills Creek Formation, a calcareous shale containing interbedded siltstone, sandstone, shaly limestone, and dolomite. Even though the farm adopted no-till practices in the 1970s, the axial channel of Cole Farm flows over a thick (>2.5 m) package of sediment in the valley floor. Soils range in texture from silty clay at the ridge top to sandy loam in the valley floor. Data was collected and funded by the Critical Zone Observatory Network.

Davis, Kenneth J. [Department of Meteorology, Eart↗

First ARM Mobile Facility (AMF1) Aerosol Observing System (AOS01) Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility Mobile Aerosol Observing System – Aerosols (MAOS-A), designated AOS01, entered service in March of 2012 at the Los Alamos National Laboratory for the Pajarito Aerosol Coupling to Ecosystems (PACE) field campaign. The Aerosol Observing System is meant to be a standalone, completely autonomous, aerosol sampling system. It requires only power, 208VAC 1φ or 440 VAC 1φ, and an internet connection to be operational. The physical structure is a standard-sized shipping container, 20 feet long by 8 feet wide. Inside, the walls, ceiling, and floor are insulated using >3.5” of spray polyurethane foam with an R-value of 6.2/inch of insulation. The interior walls, floor and ceiling are lined with ¾” plywood for durability and have integrated unistrut for mounting equipment.

54 ENVIRONMENTAL SCIENCES↗

Verification of RESRAD-BUILD Code Version 4

This report documents the verification of the RESRAD-BUILD code, Version 4.0, which was released on December 22, 2022. Two earlier reports verifying Versions 3.0 and 3.1, respectively, were published in 2001 (Kamboj, et al. 2001) and 2003 (Tetra Tech NUS 2003). Version 4.0 of the RESRAD-BUILD code has many new features and modeling enhancements over the earlier versions, including the previously released Version 3.5. Chapter 2 of this report focuses on verifying the external dose and risk modeling for point, line, area, and volume sources, as well as for floor deposition. Besides verification, the external radiation doses calculated by RESRAD-BUILD were also benchmarked with those calculated by the MCNP code (Briemeister 1993). Section J.3 of the RESRAD-BUILD User’s Manual Vol. 1 (Yu et al. 2022) documents the results of that benchmarking effort. Chapter 3 of this report focuses on verifying the ventilation modeling, from checking the remaining source inventory, releases of radionuclides to the air, air concentrations and deposited floor concentrations over time, to the radiation dose and risk associated with inhalation, ingestion, and air submersion, with and without vacuuming. The verification efforts involve designing spreadsheets to perform calculations the same as or like those performed by the RESRAD-BUILD code and then comparing the spreadsheet results with those produced by the code. When the results agree or the differences are within acceptable range, the accuracy of model implementation in the code is verified. In addition to model implementation, the implementation of key functions and features that facilitate the modeling or the use of the code were also verified during the release testing of the code. Appendix A presents the test cases developed for these verification testing, and Appendix B presents the testing results that verify proper implementation of key functions and features.

54 ENVIRONMENTAL SCIENCES↗

Moisture Performance of Unvented Attics With Vapor Diffusion Ports and Buried Ducts in Hot, Humid Climates

Energy efficiency measures, such as cool roofs, radiant barriers, interior radiative control coatings, and buried ducts are increasing in popularity and are promoted by energy codes because of their energy-saving potential. However, these strategies can also pose moisture risks in attics by lowering surface temperatures and increasing condensation potential and moisture accumulation. Of particular concern in hot-humid climates is dripping condensation on cold air-conditioning ductwork in the summer - commonly referred to as duct "sweating" - which threatens the attic floor with conditions conducive to mold growth and rot. One strategy to mitigate these moisture issues is to wrap ductwork in thicker duct-wrap insulation with an integrated exterior vapor barrier, but thick duct wrap can be difficult to come by, expensive, and unwieldy to work with. This study explores an alternative strategy of reducing moisture issues while embracing energy efficiency by using unvented attics with vapor diffusion ports and buried ductwork in hot-humid climates. Vapor diffusion ports have been studied so far in a wide range of U.S. climates, mostly in the context of conditioned attics. In this study, the strategy is implemented in the novel context of hot-humid climates with ductwork sitting atop blown-in attic floor insulation in unconditioned attics. Using a combination of field experiments and hygrothermal modeling, the findings of this project indicate that an unvented attic with vapor diffusion ports and buried ducts may be a key part of a successful low-cost method for reducing the attic moisture load by venting excess moisture out of the attic, keeping duct-jacket surfaces above dew point temperature, and keeping the roof deck safe from winter moisture accumulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CAD-based Energy & Cost Models Prove Affordable Net Zero Energy Performance for WonderWindows + 24" On-center Framing

Windows are thermally the “weakest link” in the building envelope. Increasing the thermal resistance of windows can make buildings more energy efficient and reduce the cost of electricity needed for conditioning the building. The proper design and placement of framing can also help to reduce the thermal bridging that occurs near the window frame area. This study investigates the energy performance of multi-pane acrylic windows fitting 24" on-center framing. Initial parametric analysis is done for a single zone accessory dwelling unit (ADU). Then, an energy model was developed for three types of wood-framed buildings: townhomes, stacked flats and hotels. A whole building energy simulation is performed for each of these building types in hot-humid Houston, mixed-humid New York, and cold-humid Minneapolis climates. The results show up to a 39% reduction in heating, ventilation, and air-conditioning (HVAC) related electricity consumption for the cold climate compared to the Base case which has window and wall properties based on ASHRAE standard 90.1 2019. In the hot climate, a modest increase in electricity consumption was seen due to an increase in cooling electricity demand. The ADU achieved Net Zero Energy performance in all 3 Climate Zones despite having the highest exterior surface area-to-floor area ratio: the ADU also had the highest PV kW to floor area ratio compared to the other multi-story building types. The townhomes, hotel and stacked flats respectively met 73, 52 and 57 % of electrical use in Houston, 71, 48 and 56 % in New York, and 63, 40 and 53 % in Minneapolis from energy produced by rooftop solar. If 400 W solar panels are used instead of 320 W panel used for energy simulation, it is estimated that in the townhomes, hotel and stacked flats rooftop solar can meet 91, 65 and 71 % of electrical use in Houston; 89, 60 and 70% in New York, and 79, 50 and 66 % in Minneapolis. A preliminary evaluation of cost shows that such superior performance can potentially be achieved at less first cost with this 24"on-center solution than conventional construction. All the building types at the three locations used for simulation had net energy use intensity under 20 kBtu/sf/year with 320 W solar panel and under 17 kBtu/sf/year with 400 W solar panel. Further tailoring of building envelope R-values and window solar heat gain to particular Climate Zone locations for each building type shows promise in reducing the HVAC electricity use that comprises almost half of building energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Microreactor Security-by-Design Recommendations for Domestic and International Deployments

This report outlines methods vendors can use to incorporate security-by-design (SeBD) into their microreactor facility design to support and address security for both U.S. and international deployment. The team developed a hypothetical below-grade microreactor with a physical protection system (PPS) to protect the microreactor against acts of theft and sabotage and evaluated it against two adversary attack scenarios defined by a group of adversary subject matter experts (SMEs). The hypothetical microreactor facility consists of two distinct buildings. The first is the above-grade protected area (PA) entry control point (ECP) building, which houses security personnel responsible for conducting screenings and managing access to the PA. The second building is the reactor building, which features both an above-grade floor and a below-grade floor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Product Defect Detection System: SYSM- 5620 Final Project

Retail sales is a growing market estimated to up to seven percent year over year. With this growing market there is also a trend in growing rate of retail returns, estimated just last year at $\$$850 billion. Retail stores must ensure that products available for purchase remain safe, undamaged, and acceptable to customers throughout their time in the store. This job exists regardless of the specific solution used because stores are always responsible for preventing damaged or defective products from reaching customers and when they fail to this is categorized under operation inefficiencies which accounts for an estimated $\$$12 billion in returns. When defective items remain on the sales floor, stores may experience increased returns, reduced customer satisfaction, loss of customer trust, and potential safety concerns depending on the product type. As a result, the core job to be done is to identify defective products quickly, remove them from the sales floor before they are purchased, and preserve useful information about the defect so that the store can improve its handling, stocking, and supplier coordination over time. The need for a more reliable process is especially important in high volume retail environments where employees manage large numbers of products across many aisles, shelves, and storage areas. In these settings, manual inspection alone can be inconsistent and difficult to sustain at the individual item level. At the same time, broader retail trends continue to emphasize operational efficiency, product visibility, and improved customer experience, creating an opportunity for more automated and data driven defect detection methods.

42 ENGINEERING↗

Determining Optimal Magnetometer Configuration on MAGIS-100

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.] (ORC↗

Determining Optimal Magnetometer Configuration on MAGIS-100

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.] (ORC↗

ECAR-8823 Rev 0 Structural Evaluation of the MARVEL Support Frame in Dry Critical Configuration

The purpose of this ECAR is to structurally evaluate the MARVEL reactor support frame during the dry critical (DryCrit) start-up testing. The ECAR includes evaluation of the DryCrit configuration for tip-over of the frame during a seismic event, floor loading of the frame on the MFC-720 (TREAT) operating floor, stress analysis of the adapter ring, and stress analysis of the frame itself for gravity and seismic loads.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

In-Situ Magnetic Field Reconstruction in the MAGIS-100 Experiment

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.; Ferm↗

A closer look in the mirror: reflections on the matter/dark matter coincidence

We argue that the striking similarity between the cosmic abundances of baryons and dark matter, despite their very different astrophysical behavior, strongly motivates the scenario in which dark matter resides within a rich dark sector parallel in structure to that of the standard model. The near cosmic coincidence is then explained by an approximate ℤ$_{2}$ exchange symmetry between the two sectors, where dark matter consists of stable dark neutrons, with matter and dark matter asymmetries arising via parallel WIMP baryogenesis mechanisms. Taking a top-down perspective, we point out that an adequate ℤ$_{2}$ symmetry necessitates solving the electroweak hierarchy problem in each sector, without our committing to a specific implementation. A higher-dimensional realization in the far UV is presented, in which the hierarchical couplings of the two sectors and the requisite ℤ$_{2}$-breaking structure arise naturally from extra-dimensional localization and gauge symmetries. We trace the cosmic history, paying attention to potential pitfalls not fully considered in previous literature. Residual ℤ$_{2}$-breaking can very plausibly give rise to the asymmetric reheating of the two sectors, needed to keep the cosmological abundance of relativistic dark particles below tight bounds. We show that, despite the need to keep inter-sector couplings highly suppressed after asymmetric reheating, there can naturally be order-one couplings mediated by TeV scale particles which can allow experimental probes of the dark sector at high energy colliders. Massive mediators can also induce dark matter direct detection signals, but likely at or below the neutrino floor.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Clarity through the neutrino fog: constraining new forces in dark matter detectors

The PandaX-4T and XENONnT experiments present indications of Coherent Elastic Neutrino Nucleus Scattering (CEνNS) from 8 B solar neutrinos at 2.6σ and 2.7σ, respectively. This constitutes the first observation of the neutrino “floor” or “fog”, an irreducible background that future dark matter searches in terrestrial detectors will have to contend with. Here, we first discuss the contributions from neutrino–electron scattering and from the Migdal effect in the region of interest of these experiments, and we argue that they are non-negligible. Second, we make use of the recent PandaX-4T and XENONnT data to derive novel constraints on light scalar and vector mediators coupling to neutrinos and quarks. We demonstrate that these experiments already provide world-leading laboratory constraints on new light mediators in some regions of parameter space.

neutrino interactions↗

Air-coupled tsunamis generated from impacts and airbursts: Our understanding before Hunga-Tonga Hunga-Ha'apai

The effort to prevent or mitigate the effects of an impact on Earth is known as planetary defense. A significant component of planetary defense research involves risk assessment. Much of our understanding of the risk from near-Earth objects comes from the geologic record in the form of impact craters, but not all asteroid impacts are crater-forming events. Small asteroids explode before reaching the surface, generating an airburst, and most impacts into the ocean do not penetrate the water to form a crater in the sea floor. The risk from these non-crater-forming ocean impacts and airbursts is difficult to quantify and represents a significant uncertainty in our assessment of the overall threat. We are currently working to better understand impact scenarios that can generate dangerous tsunamis.

54 ENVIRONMENTAL SCIENCES↗

Characterizing peak electricity demand for U.S. households: an assessment of end-use loads and demand factors

Understanding household peak electricity demand is critical to evaluate the technical need for electrical infrastructure upgrades. This study characterizes peak loads for existing and new equipment using metered data from a convenience sample of 11,940 U.S. dwellings from four sources, including 911 from two sources with end-use metering. After standardized data cleaning and labeling, we derived descriptive statistics for key metrics, such as maximum demand and demand factors, and developed predictive models relating 60- to 15-min demand for the National Electrical Code (NEC). Mean 15-min maximum demand was 9.7 kW (median 9.0 kW; IQR 7.0–11.5 kW, 95% CI 9.6–9.8 kW), indicating spare capacity in 98% of homes with hypothetical 100 A panels. Maximum demand increased with floor area and number of high-demand loads. Dwelling maximum demand was driven by higher-power, longer-duration heating appliances and vehicle charging, while most user-operated appliances contributed little. Demand factors are used to account for how most devices contribute less than their rated power to maximum demand. Existing load mean demand factors (28%; median 10%; IQR 0–58%; CI 28–29%) were higher than those for new loads (21%; median 7%; IQR 0–35%; CI 20–21%), because new loads changed the timing and magnitude of maximum demand. New high-demand loads had higher than average demand factors (40–60%). Whole dwelling demand factors support the NEC's 40% assumption, but they challenge its conservative 100% treatment of new HVAC. We propose a data-driven 50% demand factor for new equipment, which would align with metered data, improve affordability, and modernize electrical codes.

Appliances↗

Consumer safety-oriented scheduling of rotating power outages during heat waves

Extreme heat events have widespread effects on power systems, reducing available generation capacity, limiting transmission capabilities, and causing unusual demand patterns on the consumer side. As these combined effects expose bulk transmission systems to potential large-scale blackouts, utilities may be required to schedule and apply rotating outages, by temporarily and alternately disconnecting distribution substations to reduce overload. However, utilities lack mechanisms to inform these events, exacerbating the negative effects of heat waves on affected communities. This paper introduces a novel framework for scheduling rotating outages during heat waves while considering impacts on consumers’ safety. Instead of random sequential load shedding, we propose a methodology to rotate power outages considering a metric that quantifies the indoor overheating risk of groups of consumers during a power outage. The overheating risk is derived from a detailed building simulation using CityBES, where the buildings are modeled based on available data—use type, year built, floor area, number of stories, location—while presence of air conditioning and occupancy are calibrated from smart meter data. Based on the metric, an algorithm to schedule the rotating outages is applied to prioritize feeders for disconnection at each hour according to their overheating risk to meet a utility load reduction target. Applied to two substations and seven feeders in the Portland General Electric territory, the results show that this approach effectively leads to the lowest overheating risk during the resulting outage schedules, with an average 10.1% lower overheating compared to uninformed schedules.

Building thermal simulation↗