Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fire modelling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Fire Risk Investigation in 3D (FRI3D) Software and Process for Integrated Fire Modeling

Modeling and implementing fire safety for nuclear power plants is a costly activity. Because of the complexity of fire phenomena and multiple operational procedures, it is difficult to computationally provide assurance that mitigation methods are adequate for critical areas using current analysis methods in a cost-effective manner. The nuclear industry needs efficient methods to provide more accurate modeling and optimize mitigation methods to improve nuclear power plant understanding for fire scenarios. This report describes the work done over the last two year on the Fire Risk Investigation in 3D (FRI3D) software. This software simplifies the modeling process by importing existing plant models and data, incorporating a 3D modeling environment and coupling with the fire simulation software CFAST. This eliminates the manual labor and errors associated with much of the fire modeling process. The report lays out the status and path of FRID software for the Risk Informed Safety Analysis pathway of the Light Water Reactor Sustainability project at Idaho National Laboratory and industry collaborators to best help reduce costs and improve realism in fire probabilistic risk analysis.

97 MATHEMATICS AND COMPUTING↗

Global fire modelling and control attributions based on the ensemble machine learning and satellite observations

Contemporary fire dynamics is one of the most complex and least understood land surface phenomena. Global fire controls related to climate, vegetation, and anthropogenic activity are usually intertwined, and difficult to disentangle in a quantitative way. Here, we leveraged an ensemble of five machine learning (ML) models and multiple satellite-based observations to conduct global fire modeling for three fire metrics (burned area, fire number, and fire size), and quantified driving mechanisms underlying annual fire changes in a spatially resolved manner for the period 2003–2019. Ensemble learning is a meta-approach that combines multiple ML predictions to improve accuracy, robustness, and generalization performance. We found that the optimized ensemble ML well reproduced annual dynamics of global burned area (R 2 = 0.90, P < 0.001), total fire numbers (R 2 = 0.86, P < 0.001), and averaged fire size (R 2 = 0.70, P < 0.001). Additionally, the ensemble ML captured key spatial patterns of multi-year mean magnitudes, annual variabilities, anomalies, and trends for different fire metrics. Our ML-based fire attributions further highlighted the dominant role of enhanced anthropogenic activity in reducing global burned area (–1.9 Mha/yr, P < 0.01), followed by climate control (–1.3 Mha/yr, P < 0.01) and insignificant positive vegetation control (0.4 Mha/yr, P = 0.60). Spatially, climate dominated a much larger burned area (53.7%) than human (23.4%) or vegetation control (22.9%); however, the counteracting effects from regional wetting and drying trends weakened the net climate impacts on global burned area. The fire number and fire size exhibited similar spatial control patterns with burned area; globally, however, fire number tended to be more affected by climate while fire size more influenced by human activities. Overall, our study confirmed the feasibility and efficiency of ensemble ML in global fire modeling and subsequent control attributions, providing a better understanding of contemporary fire regimes and contributing to robust fire projections in a changing environment.

54 ENVIRONMENTAL SCIENCES↗

Comparison of Fire Model Predictions with Experiments Conducted in a Hangar With a 15 Meter Ceiling

The purpose of this study is to examine the predictive capabilities of fire models using the results of a series of fire experiments conducted in an aircraft hangar with a ceiling height of about 15 m. This study is designed to investigate model applicability at a ceiling height where only a limited amount of experimental data is available. This analysis deals primarily with temperature comparisons as a function of distance from the fire center and depth beneath the ceiling. Only limited velocity measurements in the ceiling jet were available but these are also compared with those models with a velocity predictive capability.

MATHEMATICAL MODELS↗

Fire Modeling of a Facility for Combustible Loading

The purpose of this project was to create a fire model of the facility. Results from the model will be used to establish standoff distances from combustible fuel packages in the facility, in order to protect material from a thermal event.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of JP-4 fire test data and development of a simple fire model

A series of field experiments involving JP-4 fires of 7.6m dia and 15.2m dia was conducted under the sponsorship of NASA. The temperature inside the fire, the specie composition and vertical axial velocity were measured at several height locations and radial positions. The peak temperature recorded is 1400-1500 K; the velocities at 6m height are 11-12 m/s. The oxygen-to-nitrogen mass ratio along the vertical axis was found to be nearly a constant at 0.05. Significant necking of the fire was observed. A simple theoretical model was developed that predicts the experimental data on the velocity and vertical temperature distribution well. The model is based on the partial combustion of entrained air and assumed top-hat distributions for various property and flow parameters inside the fire. Quantitative agreement is obtained by using a value of 0.15 for the entrainment coefficient and 0.45 for the mixing efficiency factor. The model also predicts the fire necking.

Raj, P. K.↗

Mathematical model of fires

Model allows predictions of future development of fire and can be used to evaluate different control methods at particular stages of fire. Five constraints considered are flame-spread rate, fuel-surface limit, airflow limit, quantity of fuel, original quantity of air.

Coulbert, C. D.↗

Model fire tests on polyphosphazene rubber and polyvinyl chloride (PVC)/nitrile rubber foams

A video tape record of model room fire tests was shown, comparing polyphosphazene (P-N) rubber and polyvinyl chloride (PVC)/nitrile rubber closed-cell foams as interior finish thermal insulation under conditions directly translatable to an actual fire situation. Flashover did not occur with the P-N foam and only moderate amounts of low density smoke were formed, whereas with the PVC/nitrile foam, flashover occurred quickly and large volumes of high density smoke were emitted. The P-N foam was produced in a pilot plant under carefully controlled conditions. The PVC/nitrile foam was a commercial product. A major phase of the overall program involved fire tests on P-N open-cell foam cushioning.

Widenor, W. M.↗

Analysis of NASA JP-4 fire tests data and development of a simple fire model

The temperature, velocity and species concentration data obtained during the NASA fire tests (3m, 7.5m and 15m diameter JP-4 fires) were analyzed. Utilizing the data analysis, a sample theoretical model was formulated to predict the temperature and velocity profiles in JP-4 fires. The theoretical model, which does not take into account the detailed chemistry of combustion, is capable of predicting the extent of necking of the fire near its base.

Raj, P.↗

Compartment Fire Modeling of a Crew Cabin in 1-g and Lunar-g

A fire inside a spacecraft poses one of the greatest dangers to the crew and mission success. As missions become more complex and longer in duration, the risk of a fire becomes more probable and catastrophic. A greater understanding of the effects of a fire inside a crewed vehicle at potential exploration atmospheres is needed. These exploration atmospheres, such as those being proposed for upcoming Lunar missions, include higher oxygen concentrations and lower pressures, also known as Normoxic conditions. Full scale fire testing, such as those performed during previous space programs, is the most straightforward way to obtain this understanding. These tests are difficult to implement in 1-g and even more challenging to attempt in Lunar-g. Modeling can help inform experiments aimed at determining flammability properties of common materials at exploration atmospheres, as well as determine the effect a fire has inside a spacecraft. A model can also be easily simulated in Lunar-g to predict the effect of gravity on fire propagation. This work focuses on a model of a theoretical partial crew cabin, with potential fire sources being a laptop and a Nomex sleeping bag. A simulation of the crew cabin during a high Heat Release Rate (HRR) fire and low HRR fire at 1-g was compared to simulations at Lunar-g. It was found that in both the low and high HRR cases, the temperature in the cabin was higher in the Lunar-g case than in the 1-g case. This is likely due to the hot products moving out the door of the crew cabin faster in the 1-g case. Modeling case studies like these will help guide future full-scale flammability experiments on Earth and allow for the prediction of fire spread in a Lunar gravity environment in order to design a safer crew cabin.

Fire Safety↗

Expansion of high-latitude deciduous forests driven by interactions between climate warming and fire: Modeling Archive

This Modeling Archive is in support of an NGEE Arctic publication. More information in the related references. The dataset is a model (ecosys) output used in a study that examined the potential future shifts in high-latitude vegetation types (PFTs) driven by changes in 21st century climate and fire. The study highlights the importance of mechanistically representing differences in plant functional traits on current and possible 21st century trajectories of Alaskan PFTs. This dataset package includes 13 files in pdf, csv, and nc formats.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Sodium Pool Fire Phenomena, Sodium Pool Fire Modeling in SOFIRE II, and SOFIRE II Calculations for the AFR-100

The SOFIRE II computer code for the calculation of sodium pool fires has been obtained from the Reactor Safety Information Computational Center and the SOFIRE II ONE CELL version has been implemented at Argonne National Laboratory (ANL). A critical review of literature relevant to sodium pool fires has been carried out with the objectives of understanding sodium pool fire phenomena and how well specific phenomena are modeled or neglected in SOFIRE II. Significant predictions about sodium pool fires can be made on the basis of first principles analyses alone making use of the existing experiment database and knowledge base. In implementing SOFIRE II ONE CELL, minor modifications were necessary to compile and execute the code on a personal computer (PC) and to verify the results of the test case problem. The code was applied to the AFR-100 Sodium-Cooled Fast Reactor (SFR) design to calculate a sodium pool fire following a postulated failure of the sodium storage vessel of one of the four intermediate sodium heat transport circuits and the subsequent release of sodium onto the floor of the steel-lined compartment in which the sodium storage vessel is located. SOFIRE II calculates that only a small fraction of the released sodium burns due to the rapid consumption of the available oxygen inside of the closed compartment. The preliminary results demonstrate the effects of the heat sinks provided by the compartment floor, walls, and ceiling in reducing the temperature of the sodium pool with time.

Sienicki, James J.↗

Modeling Fire Severity in Black Spruce Stands in the Alaskan Boreal Forest Using Spectral and Non-Spectral Geospatial Data

Biomass burning in the Alaskan interior is already a major disturbance and source of carbon emissions, and is likely to increase in response to the warming and drying predicted for the future climate. In addition to quantifying changes to the spatial and temporal patterns of burned areas, observing variations in severity is the key to studying the impact of changes to the fire regime on carbon cycling, energy budgets, and post-fire succession. Remote sensing indices of fire severity have not consistently been well-correlated with in situ observations of important severity characteristics in Alaskan black spruce stands, including depth of burning of the surface organic layer. The incorporation of ancillary data such as in situ observations and GIS layers with spectral data from Landsat TM/ETM+ greatly improved efforts to map the reduction of the organic layer in burned black spruce stands. Using a regression tree approach, the R2 of the organic layer depth reduction models was 0.60 and 0.55 (pb0.01) for relative and absolute depth reduction, respectively. All of the independent variables used by the regression tree to estimate burn depth can be obtained independently of field observations. Implementation of a gradient boosting algorithm improved the R2 to 0.80 and 0.79 (pb0.01) for absolute and relative organic layer depth reduction, respectively. Independent variables used in the regression tree model of burn depth included topographic position, remote sensing indices related to soil and vegetation characteristics, timing of the fire event, and meteorological data. Post-fire organic layer depth characteristics are determined for a large (N200,000 ha) fire to identify areas that are potentially vulnerable to a shift in post-fire succession. This application showed that 12% of this fire event experienced fire severe enough to support a change in post-fire succession. We conclude that non-parametric models and ancillary data are useful in the modeling of the surface organic layer fire depth. Because quantitative differences in post-fire surface characteristics do not directly influence spectral properties, these modeling techniques provide better information than the use of remote sensing data alone.

Barrett, K.↗

Fighting Fire with Fire: Modeling the Datacenter-Scale Effects of Targeted Superlattice Thermal Management

Local thermal hot-spots in microprocessors lead to worst case provisioning of global cooling resources, especially in large-scale systems. However, efficiency of cooling solutions degrade non-linearly with supply temperature, resulting in high power consumption and cost in cooling - 50 {approx} 100% of IT power. Recent advances in active cooling techniques have shown on-chip thermoelectric coolers (TECs) to be very efficient at selectively eliminating small hot-spots, where applying current to a superlattice film deposited between silicon and the heat spreader results in a Peltier effect that spreads the heat and lowers the temperature of the hot-spot significantly to improve chip reliability. In this paper, we propose that hot-spot mitigation using thermoelectric coolers can be used as a power management mechanism to allow global coolers to be provisioned for a better worst case temperature leading to substantial savings in cooling power. In order to quantify the potential power savings from using TECs in data center servers, we present a detailed power model that integrates on-chip dynamic and leakage power sources, heat diffusion through the entire chip, TEC and global cooler efficiencies, and all their mutual interactions. Our multiscale analysis shows that, for a typical data center, TECs allow global coolers to operate at higher temperatures without degrading chip lifetime, and thus save {approx}27% cooling power on average while providing the same processor reliability as a data center running at 288K.

97 MATHEMATICS AND COMPUTING↗