Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fiber optic distributed temperature sensing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Evaluation of ARM tethered-balloon system instrumentation for supercooled liquid water and distributed temperature sensing in mixed-phase Arctic clouds

A tethered-balloon system (TBS) has been developed and is being operated by Sandia National Laboratories (SNL) on behalf of the U.S. Department of Energy's (DOE) Atmospheric Radiation Measurement (ARM) User Facility in order to collect in situ atmospheric measurements within mixed-phase Arctic clouds. Periodic tethered-balloon flights have been conducted since 2015 within restricted airspace at ARM's Advanced Mobile Facility 3 (AMF3) in Oliktok Point, Alaska, as part of the AALCO (Aerial Assessment of Liquid in Clouds at Oliktok), ERASMUS (Evaluation of Routine Atmospheric Sounding Measurements using Unmanned Systems), and POPEYE (Profiling at Oliktok Point to Enhance YOPP Experiments) field campaigns. The tethered-balloon system uses helium-filled 34 m 3 helikites and 79 and 104 m 3 aerostats to suspend instrumentation that is used to measure aerosol particle size distributions, temperature, horizontal wind, pressure, relative humidity, turbulence, and cloud particle properties and to calibrate ground-based remote sensing instruments. Supercooled liquid water content (SLWC) sondes using the vibrating-wire principle, developed by Anasphere Inc., were operated at Oliktok Point at multiple altitudes on the TBS within mixed-hase clouds for over 200 h. Sonde-collected SLWC data were compared with liquid water content derived from a microwave radiometer, Ka-band ARM zenith radar, and ceilometer at the AMF3, as well as liquid water content derived from AMF3 radiosonde flights. The in situ data collected by the Anasphere sensors were also compared with data collected simultaneously by an alternative SLWC sensor developed at the University of Reading, UK; both vibrating-wire instruments were typically observed to shed their ice quickly upon exiting the cloud or reaching maximum ice loading. Temperature sensing measurements distributed with fiber optic tethered balloons were also compared with AMF3 radiosonde temperature measurements. Combined, the results indicate that TBS-distributed temperature sensing and supercooled liquid water measurements are in reasonably good agreement with remote sensing and radiosonde-based measurements of both properties. From these measurements and sensor evaluations, tethered-balloon flights are shown to offer an effective method of collecting data to inform and constrain numerical models, calibrate and validate remote sensing instruments, and characterize the flight environment of unmanned aircraft, circumventing the difficulties of in-cloud unmanned aircraft flights such as limited flight time and in-flight icing.

47 OTHER INSTRUMENTATION↗

Cascaded Sapphire Fiber Bragg Gratings Inscribed by Femtosecond Laser for Molten Steel Studies

This research reports a distributed fiber optic high-temperature sensing system tailored for applications in the steel industry and various other sectors. Recent advancements in optical sensor technology have led to the exploration of sapphire crystal fibers as a solution for sensing in harsh environments. Utilizing a femtosecond (fs) laser, cascaded fiber Bragg gratings (FBGs) were meticulously fabricated within a multimode sapphire optical fiber. These FBGs endowed the system with distributed sensing capabilities and underwent rigorous testing under extreme temperatures, reaching up to 1800 °C. Here, the study delves into the investigation of the FBG reflection spectrum, facilitated by the development of a sophisticated multimode demodulation system, which contributed to the attainment of precise temperature measurements with a performance accuracy of 99.9%. Demonstrating exceptional thermal stability, the sapphire FBGs endured temperatures of 1600 °C for a sustained duration of 22 h. Furthermore, this article explores the application of distributed temperature sensing employing multiple sapphire FBGs, showcasing their utility in temperature measurements related to molten steel studies.

47 OTHER INSTRUMENTATION↗

EGS Collab Experiment 2: Distributed Fiber Optic Temperature Data (DTS)

Distributed fiber optic sensing was an important part of the monitoring system for EGS Collab Experiment #2. A single loop of custom fiber package was grouted into the four monitoring boreholes that bracketed the experiment volume. This fiber package contained two multi-mode fibers and four single-mode fibers. These fibers were connected to an array of fiber optic interrogator units, each targeting a different measurement. The distributed temperature system (DTS) consisted of a Silixa XT-DTS unit, connected to both ends of one of the two multi-mode fibers. This system measured absolute temperature along the entire length of fiber for the duration of the experiment at a sampling rate of approximately 10 minutes. This dataset includes both raw data in XML format from the XT-DTS, as well as a processed dataset with the sections of data pertaining only to the boreholes are extracted. We have also included a report that provides all of the relevant details necessary for users to process and interpret the data for themselves. Please read this accompanying report. If, after reading it, there are still outstanding questions, please do not hesitate to contact us. Happy processing.

15 GEOTHERMAL ENERGY↗

Distributed fiber-optic sensing in a subscale high-temperature superconducting dipole magnet

High-temperature superconductors, such as REBa2Cu3O7−x (REBCO, RE = rare earth), are becoming pivotal for high-field magnet technology for future circular colliders and compact fusion reactors. The U.S. Magnet Development Program, in collaboration with industry, is developing REBCO magnet technology using round conductors consisting of multiple REBCO tapes. For these multi-tape cables, traditional instrumentation, such as voltage taps and resistive strain gauges, become insufficient to help measure and understand the performance-limiting factors in these model magnets. Distributed fiber-optic sensing (DFOS) is a potential solution to address this challenge. Although DFOS is well established for various applications, measuring temperature and strain in high-temperature superconducting magnets is in its infancy. Here we report the detailed implementation and test results of DFOS based on Rayleigh scattering in a subscale canted cosθ (CCT) dipole magnet using high-temperature superconducting CORC® wires. We co-wound optical fibers in each layer of the CCT magnet and compared different types of commercial fibers and mold-release agents to reduce the power attenuation in the fibers. The DFOS allowed us to measure mechanical deformation and temperature along the conductor during tests at 77 and 4.2 K. The measured strain agreed quantitively with a finite-element mechanical model of the subscale magnet. Our results indicate that DFOS can effectively identify locations of strain and temperature changes, offering unique insight into magnet performance that can advance our understanding and development of the REBCO magnet technology for high-energy physics and fusion applications.

Luo, Linqing↗

Interpretation of Fracture Initiation Points by In-Well Low-Frequency Distributed Acoustic Sensing in Horizontal Wells

Summary Low-frequency distributed acoustic sensing (LF-DAS) exploits the optical phase shift of Rayleigh backscatter in fiber-optic cables to obtain distributed measurements of changes in strain and temperature. Fiber-optic cables are often installed for multistage hydraulic fracture diagnostics in horizontal wells. LF-DAS in an untreated well provides far-field strain measurements, while offset wells are hydraulically fractured. Such a configuration is called crosswell LF-DAS sensing. Crosswell LF-DAS measurements have proved useful in diagnosing fracture hits, fracture azimuth, planarity, cluster efficiency, fracture propagation rates, and the dynamic distance to the fracture front. In contrast, in-well LF-DAS is conducted on the actively fractured well. Due to cool fracture fluid being injected at high injection rates, the strain component of the LF-DAS response is largely obscured by temperature changes. In permanent fiber-optic cable installations, distributed temperature sensing (DTS) is often conducted simultaneously with LF-DAS. An opportunity exists to decouple the temperature and strain components of LF-DAS sensors to observe strain changes on in-well LF-DAS. The LF-DAS response is modeled as linearly dependent on strain and temperature changes. Theoretical LF-DAS temperature and strain sensitivity coefficients are derived based on the changes to the index of refraction and length of the fiber. Using the DTS measurements, temperature changes are computed, smoothed, filtered, and compared to the LF-DAS response. Crossplots of the in-well LF-DAS measurements and temperature changes from DTS measurements far from the actively fractured region are used to validate the theoretical sensitivity coefficients. Uncertainty in the temperature component of the LF-DAS response is quantified. The difficulty in corresponding the different spatial and temporal resolutions of the DTS and LF-DAS measurements is overcome by comparing the responses over a moving temporal and spatial window. If the LF-DAS response at the center of the window agrees with the DTS response within uncertainty, the measurement is filtered out. After filtering, the remaining nonzero in-well LF-DAS measurements are due to changes in strain. The data are then visualized in waterfall plots. The results indicate that the theoretical and observed strain and temperature coefficients agree within 10%. After the temperature component of the in-well LF-DAS response is extracted, the remaining nonzero measurements are located primarily within the actively treated region. Locations with peaks in the strain response are interpreted to indicate fracture initiation points. These fracture initiation points are compared with in-well DTS and high-frequency DAS noise measurements across multiple stages to better understand fracture initiation along the horizontal well.

Engineering↗

Utah FORGE: Well 16B(78)-32 DTS, RFS DSS Strain, and Absolute Strain Circulation Test Fiber Optic Data - August 2024

This dataset contains processed fiber optic measurements collected during the extended cross-well circulation test at the Utah FORGE site in August 2024. The data was acquired from the 16B(78)-32 well using distributed fiber optic sensing (DFOS) technology, including distributed temperature sensing (DTS) on multimode fiber and distributed strain sensing (DSS) measurements on single-mode fiber. The dataset includes Brillouin absolute strain, Rayleigh frequency shift (RFS) DSS strain change, RFS DSS strain change rate, and temperature (DTS) data, all stored in HDF5 format. Time coordinates are provided in UTC, and depth measurements are given in measured depth relative to the rotary kelly bushing (MD RKB) in feet. The spatial sampling on the RFS DSS strain data and the Brillouin Absolute Total Strain data is 20 cm and the spatial sampling on the DTS data is 1m. The dataset is accompanied by a report from Neubrex, which provides further documentation.

15 GEOTHERMAL ENERGY↗

Utah FORGE: Neubrex Well 16B(78)-32 Circulation Test Fiber Optics Monitoring Data and Reports - July, 2023

This dataset features Distributed Acoustic Sensing (DAS) and fiber optics monitoring data acquired by Neubrex Energy Services during the Utah FORGE Well 16B(78)-32 circulation test in July 2023. DAS and fiber optic monitoring data include absolute strain, strain change, strain change rate, distributed temperature sensing (DTS), and frequency band extraction (FBE). Data processing was completed between September and October 2023. The dataset includes the fiber optic sensing data collected during these operations, along with a data collection report, descriptions of the data, and instructions for reading the data files.

15 GEOTHERMAL ENERGY↗

Distributed Fiber Optic Sensing to Identify Locations of Resistive Transitions in REBCO Conductors and Magnets

High-temperature superconductors such as REBa 2 Cu 3 O 7-x (REBCO, RE = rare earth) can generate strong magnetic fields that are promising for applications in particle accelerators and compact fusion reactors. Traditionally, voltage taps are installed in superconducting magnets to measure the voltage signals due to resistive transitions. The voltage-tap-based diagnostics is important for the development of magnet technology as it can help pinpoint the locations in the magnet windings that limit the magnet performance. The architecture of the multi-tape REBCO cable such as CORC wires, however, makes it difficult to apply the voltage-tap-based diagnostics to identify the locations of resistive transitions. Distributed fiber optic sensing (DFOS) has the potential to address this issue. In this paper, we report the measurements of thermal strain along a CORC wire based on optical frequency domain reflectometry with a maximum spatial resolution of 0.65 mm and a temporal resolution of 10 Hz. The optical fiber is co-wound with the CORC wire that is epoxy impregnated. During the test, current was increased until a resistive transition occurred in the conductor. The spectrum shift of the reflected light along the fiber was recorded. The results suggested that with proper thermal isolation from the cryogen, DFOS can be used to identify the locations of resistive transitions in CORC wires and magnets. In conclusion, the results will allow a better understanding of the causes of resistive transitions in REBCO conductors and magnets, which will help improve the REBCO magnet technology.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Temporal Forecasting of Distributed Temperature Sensing in a Thermal Hydraulic System With Machine Learning and Statistical Models

We benchmark performance of long-short term memory (LSTM) network machine learning model and autoregressive integrated moving average (ARIMA) statistical model in temporal forecasting of distributed temperature sensing (DTS). Data in this study consists of fluid temperature transient measured with two co-located Rayleigh scattering fiber optic sensors (FOS) in a forced convection mixing zone of a thermal tee. We treat each gauge of a FOS as an independent temperature sensor. We first study prediction of DTS time series using Vanilla LSTM and ARIMA models trained on prior history of the same FOS that is used for testing. The results yield maximum absolute percentage error (MaxAPE) and root mean squared percentage error (RMSPE) of 1.58% and 0.06% for ARIMA, and 3.14% and 0.44% for LSTM, respectively. Next, we investigate zero-shot forecasting (ZSF) with LSTM and ARIMA trained on history of the co-located FOS only, which is advantageous when limited training data is available. The ZSF MaxAPE and RMSPE values for ARIMA are comparable to those of the Vanilla use case, while the error values for LSTM increase. We show that in ZSF, performance of LSTM network can be improved by training on most correlated gauges between the two FOS, which are identified by calculating the Pearson correlation coefficient. The improved ZSF MaxAPE and RMSPE for LSTM are 4.4% and 0.33%, respectively. Performance of ZSF LSTM can be further enhanced through transfer learning (TL), where LSTM is re-trained on a subset of the FOS that is the target of forecasting. We show that LSTM pre-trained on correlated dataset and re-trained on 30% of testing target dataset achieves MaxAPE and RMSPE values of 2.32% and 0.28%, respectively.

ARIMA↗

High Fluence Active Irradiation and Combined Effects Testing of Sapphire Optical Fiber Distributed Temperature Sensors

Investigate the in-pile performance of sapphire optical fiber temperature sensors and to develop clad sapphire optical fibers for in-pile instrumentation. Evaluate the distributed sensing performance of the sensors through optical backscatter reflectometry under combined radiation and temperature effects, and high fluence.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distributed Temperature Profiles of Silicon Carbide Catalyst Bed in a Microwave Reactor using Fiber-optic Sensor

Microwave heating is of great interest for reducing greenhouse gas emissions of catalytic chemical conversion processes because it can heat up the reactants rapidly and efficiently and accelerate reaction rates. In microwave-assisted catalytic thermochemical conversion processes, accurate internal temperature measurement would help facilitate effective process control. Metallic thermocouples interfere and spark in the microwave heating environment, so they are not an option. Infrared pyrometers typically provide a single temperature value by averaging over a finite surface area of the catalyst bed. In this work, we use fiber-optic sensors passing through the catalyst bed to provide more accurate temperatures along the height of the catalyst bed. The fiber optic sensors are immune to the electromagnetic microwave radiation and provide temperature profiles along their length. Here, custom fiber-optic sensors were coupled to the optical distributed temperature sensing devices to measure the temperature profiles along the height of the catalyst bed at high temperatures with ~1 mm spatial resolution. The sensing devices use optical frequency domain reflectometry (OFDR) technique for distributed temperature measurement. This work shows the temperature profiles along the height of the silicon carbide powder catalyst bed in the variable and fixed frequency microwave reactors.

Thapa, Juddha↗

Magnetic Field Sensing via Multi-Material Acoustic Sensing Optical Fibers with Magnetostrictive Cladding Inclusions

In this conducted research, optical fiber sensors are used to measure low strength alternating magnetic fields. Various fiber sensor configurations are tested and investigated to demonstrate sensing capabilities at different field magnitudes and frequencies. Distributed acoustic sensing fibers (DAS) have been largely studied and documented across a variety of applications and sensing systems. This research uses the DAS technology in tandem with magnetostrictive materials to create a distributed multi-material optical fiber magnetic sensor. Magnetic sensing has high demand across different fields and often runs into challenges of extreme environments including high temperature, corrosion, and areas with poor accessibility. The robust and distributed nature of optical fiber sensors which can be cheaply produced for long lengths is an attractive option over other single point magnetic sensors. In down hole applications specifically, having a distributed sensor able to be deployed easily and over long distances for magnetic sensing would be a large improvement to bulkier traditional magnetometers. In the conducted study, different magnetostrictive materials are implemented in distributed optical fiber sensors to analyze and compare the effective sensitivity and potential commercial viability. Nickel, galfenol alloy, and MetGlas alloy inclusions are drawn into fused silica optical fibers with Bragg gratings inscribed later on for DAS capability. Each was investigated for its response to varying AC magnetic fields to determine relative sensitivity and resolution for distributed magnetic field sensing.

Dejneka, Zach↗

Toward local core outlet temperature monitoring in gas-cooled nuclear reactors using distributed fiber-optic temperature sensors

Gas-cooled nuclear reactors operate at temperatures up to 950 °C with significant spatial variations in power generation and coolant flow through hundreds of parallel flow channels, resulting in complex mixing at the core outlet. The high temperatures and complex mixing can damage downstream components, challenge reactor calorimetry for power determination, and result in significant conservatism in calculated peak fuel temperatures, which ultimately limits the total power output. Directly measuring each gas stream individually is unrealistic using single point thermocouples, requiring more robust sensing techniques. Fiber-optic sensors are resilient to high temperatures (up to 1,000 °C) and radiation damage. Moreover, distributed measurements can be made along the length of one fiber, making them potential candidates for monitoring local core outlet temperatures to improve core calorimetry and identify hot channels. Here, to the authors’ knowledge, this manuscript is the first to report spatially distributed fiber optic temperature measurements to quantify mixing at the outlet of a relevant orifice plate under prototypic temperature and flow regimes to assess the feasibility of using fiber-optic sensors for distributed measurements of coolant temperature in gas-cooled reactors. A single optical fiber captured dynamic changes in local temperatures, whereas the mixed outlet temperature exhibited a muted response and could not identify which channels were responsible for the change in the mixed outlet temperature. The discussion focuses on potential challenges for deploying distributed optical fibers in gas-cooled reactors, including the effects of vibrations, radiation-induced signal attenuation and drift, and routing of the fiber while minimizing flow obstructions.

42 ENGINEERING↗

Development of fracture diagnostic methods for fluid distribution based on quantitative interpretation of distributed acoustic sensing and distributed temperature sensing

Multistage hydraulic fracturing design on horizontal wells has significantly evolved with larger fluid volume, more fracturing stages, and tighter perforation cluster spacing to efficiently stimulate unconventional reservoirs. From the published field observations, the recent fracturing design results in complex fracture networks or swarm of fractures. Fracture treatment evaluation is extremely challenging in such a case because of the large amount of variables in well completion and stimulation design. Combined measurements from different technologies can help in fracture diagnosis. Fluid distribution, either during fracture injection or during production, directly relates to the stimulation efficiency at the cluster level and at the stage level. Because it is unlikely in the real world to distribute the injected fluid uniformly among all the clusters, we need diagnostic techniques to generate the flow profile along a lateral. Fiber-optic measurements, such as distributed acoustic sensing (DAS) and distributed temperature sensing (DTS), are currently used to diagnose downhole flow conditions. This technology allows us to qualitatively confirm the fluid flow profile and other issues occurring downhole during fracturing such as leakage through plugs. For optimizing a fracturing design, we also need to understand how the design parameters are correlated with the stimulation efficiency. In this study, we combine two sets of models of DAS and DTS data interpretation for injected fluid volume distribution. The DAS is interpreted based on an empirical correlation between fluid flow rates and frequency band energy from the acoustic signals. The DTS is interpreted by performing temperature history match-based thermal energy conservation. Because of the completely different physics behind the interpretations, the confirmation of two interpretations provides confidence in fluid distribution.

Geochemistry & Geophysics↗