Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fault prevalence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

28 records · Page 2

Facet-Dependent Cold Welding of Au Nanorods Revealed by Liquid Cell Transmission Electron Microscopy

Cold welding of metals at the nanoscale has been demonstrated to play a significant role in bottom-up manufacturing and self-healing processes of nanostructures and nanodevices. However, the welding mechanism at the nanoscale is not well understood. In this study, a comprehensive demonstration of the cold welding process of gold nanorods with different modes is presented through in situ liquid cell transmission electron microscopy. The experimental results and molecular dynamics simulations reveal that the nanorods are welded through the facet-dependent atomic surface diffusion and rearrangement along {100} facets. The density functional theory calculations indicate that the preferred coalescence of two {100} surfaces is thermodynamically favorable. Unlike the prevalent “oriented attachment” in the nanoparticle coalescence, the misalignment of nanorod orientations and local stresses can induce grain boundaries and stacking faults in the welded interface.

42 ENGINEERING↗

Metadata Schemas and Ontologies for Building Energy Applications: A Critical Review and Use Case Analysis

With the increasing digitalization of processes throughout the lifecycle of buildings, data exchanged between stakeholders and between building systems has grown significantly. However, a lack of semantic interoperability between data in different systems is still prevalent, hindering the development of applications that can be reused across buildings and limiting the scalability of innovative solutions. Semantics refers to the description of the meaning of the data in a way that can be consistently understood by applications. Recently, several competing initiatives have been developing metadata schemas and ontologies to express this semantic information for different applications in the building domain. This paper systematically reviews these schemas and conducts an analysis of five of them to evaluate their applicability to three high-value use cases for building operations: energy audits, automated fault detection and diagnostics and optimal control. The survey finds 40 schemas published in the last 10 years but but their actual use in industry is difficult to estimate. Among the five selected ontologies, several gaps are highlighted in relation to the three use cases. Recommendations for the future include better harmonization of these initiatives, more centralized repositories and search engines for these schemas as well as better industry engagement to facilitate their adoption.

Smart Building, Sematic, Metadata, Ontology, Data ↗

Air Handling Unit Shutdowns During Scheduled Unoccupied Hours: US Commercial Building Stock Prevalence and Energy Impact

Commercial buildings account for 18% of U.S. energy consumption, with 44% used for heating, ventilation, and air conditioning (HVAC). American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) 90.1 requires HVAC systems to shutdown fans and outdoor air ventilation during unoccupied times, only allowing fans to cycle on, without outdoor air, to maintain thermostat setpoints. However, it is minimally understood how often existing building operations align with energy code requirements and the energy implications of not doing so. This study used building automation system data from 843 buildings containing 5706 air handling units (AHUs) to determine three unoccupied AHU shutdown control schemes ranging in efficiency and then estimated their prevalence in the U.S. commercial building stock, segmented by building type. ComStock was then used to analyze the energy savings potential of implementing the most energy efficient unoccupied shutdown control scheme in non-participating buildings across the U.S commercial building stock. Results show that only 23% of AHUs align completely with the ASHRAE 90.1 requirement. ComStock modeling results show 4% annual stock energy savings by switching all non-participating buildings to the most efficient scheme, with 19% annual energy savings demonstrated for the median building switching from the least efficient scheme to the most efficient. Findings also show 114.5 TBtu electricity and 75.8 TBtu natural gas fuel savings when converting to the most efficient scheme. Furthermore, these findings help stakeholders understand the high prevalence of buildings not aligning with the ASHRAE-90.1 requirements for unoccupied AHU shutdowns and the energy savings potential of utilizing the most efficient unoccupied AHU shutdown scheme.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Unstable twin in body-centered cubic tungsten nanocrystals

Twinning is commonly activated in plastic deformation of low stacking fault face-centered cubic (Fcc) metals but rarely found in body-centered cubic (Bcc) metals under room temperature and slow strain rates. Here, by conducting in situ transmission electron microscopy (TEM) at atomic scale, we discovered that, in stark contrast to those in most Fcc metals, a majority of deformation twins in Bcc metals are unstable and undergo spontaneously detwinning upon unloading. Such unexpected instability of Bcc twins was found to be closely related to the prevalence of the inclined twin boundaries—a peculiar structure where twin boundaries are not parallel to the twinning plane, and the degree of instability is in direct proportion to the fraction of the inclined twin boundary. This work provides significant insights into the structure and stability of deformation twins in Bcc metals.

36 MATERIALS SCIENCE↗

Mitigating commutation failures in HVDC systems with SFCL deployment

Commutation failures represent a prevalent issue encountered in line-commutated-converter high voltage direct current (LCC-HVDC) systems. As the widespread deployment of HVDC systems continues, the risk associated with commutation failures increases, posing a growing threat to power grids due to their potential to trigger severe consequences, including cascading failures and widespread blackouts. This research paper aims to address the significant issue of commutation failure within direct current (DC) systems through advocating for the use of resistive-type Superconducting Fault Current Limiters (R-SFCLs). To substantiate the efficacy of this proposed strategy, an array of simulations are executed using the PSCAD/EMTDC software. This comprehensive study investigates the performance characteristics of R-SFCLs configured with varying resistance values, scrutinizing their response under diverse fault resistance scenarios and distinct fault initiation times within the LCC-HVDC system. The outcomes of these simulations are that SFCLs confer significant advantages for mitigating commutation failures, surpassing traditional mitigation methods in terms of effectiveness. Consequently, SFCLs emerge as an optimal solution to prevent commutation failures in the HVDC systems.

Commutation failure↗

The Effect of Power Electronic Loads on Western Interconnection Stability

The prevalence of power electronics in the bulk power system is increasing rapidly in both the generation and consumption of electricity. This work focuses on the effect of changing load composition - specifically the transition from single phase air conditioner motors to power electronics backed air conditioners - on power system stability. Various transmission and generation contingency events for the Western Interconnection were simulated using Positive Sequence Load Flow software and planning models from the Western Electricity Coordinating Council. In general, an increased proportion of power electronic load leads to more instability. For some specific faults resulting in fault-induced delayed voltage recovery, transitioning to higher proportions of power electronic loads helps expedite system recovery. These results demonstrate that load composition should be examined in conjunction with generation composition when evaluating system stability.

FIDVR↗

Limited Dynamic Earthquake Triggering in Nevada

Dynamic triggering occurs when seismic waves from distant large earthquakes temporarily alter stress conditions along faults, potentially triggering new earthquakes hundreds to thousands of kilometers away from the source. Previous studies have linked triggered seismicity to anthropogenic activities such as geothermal, oil, and gas production. Although these activities are present in Nevada, little work has been conducted to explore dynamically triggered seismicity in Nevada. Here, we analyze a newly published, high-resolution earthquake catalog for Nevada to identify local seismicity dynamically triggered by teleseismic events (Mw≥7) from 2008 to 2023. We identify 94 dynamically triggered earthquakes concentrated in four distinct regions, which qualitatively show a modest positive correlation with geothermal well locations. Triggered seismicity in Nevada is predominantly delayed, with some instantaneously triggered by Rayleigh waves. The prevalence of delayed triggering indicates that pore fluid interactions may play a critical role in controlling dynamic triggering susceptibility in Nevada. Our results demonstrate that dynamic triggering can provide valuable insight to help identify critically stressed regions.

58 GEOSCIENCES↗

Interrogating the Effects of Hydrogen on the Behavior of Planar Deformation Bands in Austenitic Stainless Steel

The effects of internal hydrogen on the deformation microstructures of 304L austenitic stainless steel have been characterized using electron backscattered diffraction (EBSD), transmission Kikuchi diffraction (TKD), high-resolution scanning transmission electron microscopy (HRSTEM), and nanoprobe diffraction. Samples, both thermally precharged with hydrogen and without thermal precharging, were subjected to tensile deformation of 5 and 20 pct true strain followed by multiple microscopic interrogations. Internal hydrogen produced widespread stacking faults within the as-forged initially unstrained material. While planar deformation bands developed with tensile strain in both the hydrogen-precharged and non-precharged material, the character of these bands changed with the presence of internal hydrogen. As shown by nanobeam diffraction and HRSTEM observations, in the absence of internal hydrogen, the bands were predominantly composed of twins, whereas for samples deformed in the presence of internal hydrogen, ε -martensite became more pronounced and the density of deformation bands increased. For the 20 pct strain condition, α '-martensite was observed at the intersection of ε -martensite bands in hydrogen-precharged samples, whereas in non-precharged samples α '-martensite was only observed along grain boundaries. We hypothesize that the increased prevalence of α '-martensite is a secondary effect of increased ε -martensite and deformation band density due to internal hydrogen and is not a signature of internal hydrogen itself.

36 MATERIALS SCIENCE↗

Exponential Backoff and Its Security Implications for Safety-Critical OT Protocols over TCP/IP Networks

The convergence of Operational Technology (OT) and Information Technology (IT) networks has become increasingly prevalent with the growth of Industrial Internet of Things (IIoT) applications. This shift, while enabling enhanced automation, remote monitoring, and data sharing, also introduces new challenges related to communication latency and cybersecurity. Oftentimes, legacy OT protocols were adapted to the TCP/IP stack without an extensive review of the ramifications to their robustness, performance, or safety objectives. To further accommodate the IT/OT convergence, protocol gateways were introduced to facilitate the migration from serial protocols to TCP/IP protocol stacks within modern IT/OT infrastructure. However, they often introduce additional vulnerabilities by exposing traditionally isolated protocols to external threats. This study investigates the security and reliability implications of migrating serial protocols to TCP/IP stacks and the impact of protocol gateways, utilizing two widely used OT protocols: Modbus TCP and DNP3. Our protocol analysis finds a significant safety-critical vulnerability resulting from this migration, and our subsequent tests clearly demonstrate its presence and impact. A multi-tiered testbed, consisting of both physical and emulated components, is used to evaluate protocol performance and the effects of device-specific implementation flaws. Through this analysis of specifications and behaviors during communication interruptions, we identify critical differences in fault handling and the impact on time-sensitive data delivery. The findings highlight how reliance on lower-level IT protocols can undermine OT system resilience, and they inform the development of mitigation strategies to enhance the robustness of industrial communication networks.

DNP3↗

Cascaded Control for Building HVAC Systems in Practice

Actuator hunting is a widespread and often neglected problem in the HVAC field. Hunting is typically characterized by sustained or intermittent oscillations, and can result in decreased efficiency, increased actuator wear, and poor setpoint tracking. Cascaded control loops have been shown to effectively linearize system dynamics and reduce the prevalence of hunting. This paper details the implementation of cascaded control architectures for Air Handling Unit chilled water valves at three university campus buildings. A framework for implementation the control in existing Building Automation software is developed that requires only a single line of additional code. Results gathered for more than a year show that cascaded control not only eliminates hunting in control loops with documented hunting issues, but provides better tracking and more consistent performance during all seasons. A discussion of efficiency losses due to hunting behavior is presented and illustrated with comparative data. Furthermore, an analysis of cost savings from implementing cascaded chilled water valve control is presented. Field tests show 2.2–4.4% energy savings, with additional potential savings from reduced operational costs (i.e., maintenance and controller retuning).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗