Experimental Investigation of Steel-Borne Acoustic Pulses for Fault Pinpointing in Pipe-Type Cable Systems: A Scaled-Down Model Approach

Pipe-type cable systems, including high-pressure fluid-filled (HPFF) and high-pressure gas-filled cables, are widely used for underground high-voltage transmission. These systems consist of insulated conductor cables within steel pipes, filled with pressurized fluids or gases for insulation and cooling. Despite their reliability, faults can occur due to insulation degradation, thermal expansion, and environmental factors. As many circuits exceed their 40-year design life, efficient fault localization becomes crucial. Fault location involves prelocation and pinpointing. Therefore, a novel pinpointing approach for pipe-type cable systems is proposed, utilizing accelerometers mounted on a steel pipe to capture fault-induced acoustic signals and employing the time difference of arrival method to accurately pinpoint the location of the fault. The experimental investigations utilized a scaled-down HPFF pipe-type cable system setup, featuring a carbon steel pipe, high-frequency accelerometers, and both mechanical and capacitive discharge methods for generating acoustic pulses. The tests evaluated the propagation velocity, attenuation, and pinpointing accuracy with the pipe in various embedment conditions. The experimental results demonstrated accurate fault pinpointing in the centimeter range, even when the pipe was fully embedded, with the acoustic pulse velocities aligning closely with the theoretical values. These experimental investigation findings highlight the potential of this novel acoustic pinpointing technique to improve fault localization in underground systems, enhance grid reliability, and reduce outage duration. Further research is recommended to validate this approach in full-scale systems.

Moutassem, Zaki↗

Assessment of the Phase-to-Ground Fault Apparent Admittance Method with Phase/Ground Boundaries to Detect Types of Electrical Faults for Protective Relays Using Signature Library and Simulated Events

Protective relays in electric power grids recognize the types of electrical faults in a few seconds. The most common detection method to detect the types of electrical faults is based on measuring the angle between the zero and negative sequence currents. However, it is not completely accurate because the phase-to-phase-ground and phase-to-ground electrical faults could have the same detection conditions. Therefore, engineers need to plot the events after an electrical fault to observe the nature of the incidents in detail. In this study, the phase-to-ground fault apparent (PGFA) admittance method with phase/ground boundaries identified the types of electrical faults located in distribution power lines and feeders. This method was based on measuring the PGFA admittance magnitudes for the faulted and nonfaulted phases, resulting in greater than zero and near zero, respectively. The PGFA admittance algorithm was built with MATLAB/Simulink software and tested with signature library and grid simulation events. The PGFA method with phase/ground boundaries was evaluated with the confusion matrix. The measured and predicted values matched in more than 90% of the tests, and the PGFA admittance method with phase/ground boundaries presented an accuracy of 94.3% and a precision of 100%.

42 ENGINEERING↗

Assessment of the Phase-to-Ground Fault Apparent Admittance Method with Phase/Ground Boundaries to Detect Types of Electrical Faults for Protective Relays Using Signature Library and Simulated Events

Protective relays in electric power grids recognize the types of electrical faults in a few seconds. The most common detection method to detect the types of electrical faults is based on measuring the angle between the zero and negative sequence currents. However, it is not completely accurate because the phase to phase ground and phase to ground electrical faults could have the same detection conditions. Therefore, engineers need to plot the events after an electrical fault to observe the nature of the incidents in detail. In this study, the phase to ground fault apparent (PGFA) admittance method with phase/ground boundaries identified the types of electrical faults located in distribution power lines and feeders. This method was based on measuring the PGFA admittance magnitudes for the faulted and non-faulted phases, resulting in greater than zero and near zero, respectively. The PGFA admittance algorithm was built with MATLAB/ Simulink software and tested with signature library and grid simulation events. The PGFA method with phase/ground boundaries was evaluated with the confusion matrix. The measured and predicted values matched in more than 90% of the tests, and the PGFA admittance method with phase/ground boundaries presented an accuracy of 94.3% and a precision of 100%.

Piesciorovsky, Emilio↗

Modeling supercritical CO2 injection induced rupture of a minor fault embedded in a poroelastic layered reservoir-caprock system

CO2 injection for geologic carbon sequestration involves hydromechanical processes that lead to changes in fluid pressure and stresses that can activate existing faults. This paper presents a new method and workflow of modeling fault activation considering more complex three-dimensional geometry of natural faults using the TOUGH-FLAC multiphase fluid flow and geomechanical simulator. In this method and workflow, FLAC3D mechanical interfaces and TOUGH3 finite volume elements are discretized using computer aided design and gridding software along with a tailored mesh translation routine. The method and workflow are demonstrated with a model of a curved minor fault embedded in a poro-elastic layered reservoir-caprock system. The model is used for a comprehensive sensitivity analysis of fault responses to fault length, injection mass rate, injection schedule, well-fault distance, and well locations versus fault location. Four metrics (CO2 plume, shear state of fault, pressure and stress path at fault monitoring points) are selected to assess CO2 migration, pressure change, and the reactivation of faults. The results reveal that CO2 can bypass around the tip of the minor impermeable fault, building up pressure and poro-elastic stress on both sides that tends to impede fault rupture. Our study shows the benefit of carefully designing the injection to achieve the targeted final storage volume, starting at a relatively low rate for considerable time, and then ramping up the injection rate to the full rate of injection. The initial low injection has two distinct benefits: (1) it allows for the formation of an extensive CO2 plume with a much higher mobility through a low viscosity that will result in a lower pressure for a given injection rate, and (2) it allows for gradual build-up of horizontal poro-elastic stress within the reservoir that will tend to impede activation of steeply dipping faults. The injection scenario starting at a low injection rate, denoted here as conservative injection, can significantly reduce the risk of fault activation as high fluid mobility and reservoir strengthening poro-elastic stress has been established long before reaching the peak injection rates. Moreover, simultaneous injection in two injection wells on both sides of fault can provide further reservoir strengthening through poro-elastic stress buildup acting on a fault under normal faulting stress regime. The findings presented in the paper can provide practical and effective guidance on long-term, safe, and reliable geological CO2 storage.

Cao, Meng↗

Quantifying the Protectability of Power Systems for Restoration Applications

With the increasing availability of distributed energy resources, controllable switches, and advanced metering infrastructure, distribution systems are exploring opportunities for improving system reliability through fault location, isolation, and service restoration. During permanent outages, this requires islanding microgrids and/or reconfiguration of the feeders; however, it is critical to assess the protection of the islanded/reconfigured networks before transition because the rated load and fault current conditions change. This paper presents a novel “protectability” metric that quantifies the protection performance and allows the operators to compare the effectiveness of the protection between two or more possible reconfiguration and islanding approaches. We present the mathematical formulation and assumptions for the metric. Multiple configurations of the Electric Power Research Institute J1 feeder, both in grid-connected and weak-sourced islanded operation, are used to demonstrate the performance of the metric with reference to overcurrent protection. Takeaways for future studies on system planning integration are provided.

distributed energy resources↗

Distributed Energy Resource-Cognizant Upgrade Paths to the Traditional Restoration Strategy of Utilities for Improved Load Restoration

Climate change has resulted in increasingly impactful and more frequent occurrences of extreme weather events. This trend poses a significant challenge for distribution utilities and system operators to ensure that there is uninterrupted power supply to critical loads in their networks under fault scenarios; however, currently, utilities deploying the automated fault location, isolation and restoration (FLISR) function in their advanced distribution management system (ADMS) do not take into account the available generation and load-modification capabilities of distributed energy resources present in the disconnected network due to an upstream isolated fault. This results in the network reconfiguration and restoration to result in sub-optimal load restoration. Therefore, this paper presents two approaches that can upgrade the existing FLISR capabilities of distribution utilities to significantly increase the restoration of critical loads. The performance of the proposed approaches is evaluated on a numerical model of a real distribution feeder in Georgia, USA.

DER↗

Distributed Energy Resource-Cognizant Upgrade Paths to the Traditional Restoration Strategy of Utilities for Improved Load Restoration: Preprint

Climate change has resulted in increasingly impactful and more frequent occurrences of extreme weather events. This trend poses a significant challenge for distribution utilities and system operators to ensure that there is uninterrupted power supply to critical loads in their networks under fault scenarios; however, currently, utilities deploying the automated fault location, isolation and restoration (FLISR) function in their advanced distribution management system (ADMS) do not take into account the available generation and load-modification capabilities of distributed energy resources present in the disconnected network due to an upstream isolated fault. This results in the network reconfiguration and restoration to result in sub-optimal load restoration. Therefore, this paper presents two approaches that can upgrade the existing FLISR capabilities of distribution utilities to significantly increase the restoration of critical loads. The performance of the proposed approaches is evaluated on a numerical model of a real distribution feeder in Georgia, USA.

DER↗

A Time-Domain Protection Approach for AC Transmission Systems With Grid-Forming Resources

Ac transmission protection must reliably detect, classify, and locate short-circuit faults from voltage and current measurements. At present, these functionalities, which have been classically engineered using phasors approaches, are being challenged by the dynamic behavior and fault-current limits of converter-based generation. This paper tackles these challenges by engineering a time-domain protection approach that leverages the classical Bergeron model in a new manner. Low- and high-impedance faults are detected and classified by ascertaining how well line voltage and current measurements match the Bergeron equations. Faults are located by posing a novel one-variable optimization problem, whereas voltage and current waveforms at the fault location are estimated by unveiling rigorous relationships. The proposed elements are secure against external faults, measurement errors, and variation of line parameters and sampling time. Furthermore, these advances are tested via electromagnetic transient simulations and are significant to satisfy IEEE and North American Electric Reliability Corporation requirements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Laplace-Domain Circuit Model for Fault and Stability Analysis Considering Unbalanced Topology

For systems subject to unbalanced faults, analytical model building for stability assessment is a challenging task. This letter presents a straightforward modeling approach. A generalized dynamic circuit representation is achieved by use of the Laplacian transform variable s . Here, we translate the voltage and current relationship at the fault location into the relationship of three subsystems. The final circuit model is an interconnected sequence network with impedances in the Laplace domain. This circuit can be directly converted from a steady-state sequence network. This modeling procedure is illustrated by an example case of an induction motor served by a grid through a series compensated line. Electromagnetic transient simulation results demonstrate that sub-synchronous oscillations can be mitigated when a single-line to ground fault is applied at the motor terminal. Stability analysis results based on the dynamic circuit corroborate the simulation results. What's more, the derived circuit effortlessly reveals why unbalance can enhance stability.

42 ENGINEERING↗

FLISR in the Presence of DERs ADMS Test Bed Use Case

Fault location, isolation, and restoration (FLISR) is one of the distribution automation applications that utilities are most interested in. It operates groups of switches on distribution feeders to improve the reliability of power delivery after localizing outages. FLISR is an essential function for enabling a self-healing grid, and it directly affects grid reliability and resilience. The presence of DERs brings both new opportunities and challenges for FLISR applications. For instance, some DERs can work as backup generation sources and help energize local networks so more switching options can be achieved with the coordination of FLISR operations; however, the existence of DERs also brings new challenges. The bidirectional power flow resulting from DERs might require dynamic changes to protective devices' fault current settings, and thus the FLISR application will need to dynamically adjust its operations in coordination with the dynamic protection settings. Also, some FLISR applications make their service restoration decisions and close tie-switches based on predefined rules; however, the presence of DERs and their impact on altering net loads on the local feeder network are not considered. For this use case, the project team is using the FLISR application of the Survalent ADMS operating on a real-time simulation of a feeder from Central Georgia EMC, a cooperative electric utility. The performance of the FLISR application is being evaluated for different locations and combinations of DERs, including grid-forming battery energy storage systems.

ADMS↗

Mitigation of fault related voltage swell on distribution feeders using DER-based advanced inverter controls

Unbalanced faults in distribution feeders can impact voltages on the non-faulted phases. This paper models a real-life feeder with a high penetration level of solar photovoltaic (PV) units in detail including the secondary circuits, and shows a large voltage swell in one of the non-faulted phases of the feeder during a single line to ground fault. The voltages seen during this swell are more than 1.2 p.u., which can have detrimental impacts on the connected equipment and can also lead to loss of connected generation. The reason for this voltage swell is found to be the equivalent impedance at the fault location resulting from the ratio of zero and positive sequence cable impedances. It is seen that the connected solar PV units with appropriate control are able to reduce the severity of the voltage swell, especially for higher penetration levels of solar PV considered, but not entirely eliminate it.

14 SOLAR ENERGY↗

Blockchain for Fault-Tolerant Grid Operations Version 2.0

This report explores the potential of distributed ledger technology (DLT) as a transformative tool to enhance fault-tolerant operations in electrical distribution systems. Leveraging DLT's core attributes, including an immutable decentralized ledger, distributed consensus mechanisms, and state replication capabilities, this study focuses on three critical use cases. A central aspect of this research centers on the utilization of a consensus-driven ledger, providing actors within the system, such as distributed resources, with access to a reliable data repository. This empowers these actors to collaborate effectively and make informed decisions, all securely recorded on the blockchain. The first use case concentrates on data configuration, utilizing mathematical criteria---particularly, the chi-squared test for gross error detection---to identify trustworthy sensors for advanced decision-making. Building upon this foundation of trust, the second use case, topology identification, accurately determines circuit breaker states, unveiling the distribution network's topology. Ultimately, the third use case leverages this trust to execute switching actions, reconfiguring feeders and restoring power to disconnected customers after fault events. The concept of trust serves as a cornerstone in this approach, marking a departure from traditional fault location, isolation, and service restoration (FLISR) methods. Additionally, the blockchain-based architecture introduces decentralization, empowering disconnected areas to make autonomous decisions, even when communication with a central control center is disrupted. The primary contributions of this report are twofold: (1) a novel approach for evaluating distribution system voltage areas while preserving data ownership and (2) the implementation of interactions between distribution network areas using the actor model. Unlike the previous sequential approach for evaluating the area connection voltages, which required a radial network topology, this study's area model reduction enables a more versatile approach. The area model reduction addresses issues of prolonged data waiting times and multiple points of failure within the previous approach. Notably, the presented evaluation for the reduced network model area connection reveals a significant increase in the differences in voltage magnitudes. Simulation and evaluation of area agents across four distinct cases elucidate the area-level interaction behavior during a fault event. Simulations demonstrate that the proposed distributed FLISR (DFLISR) approach can successfully restore service to an affected area. Varying message delays and message loss probabilities in each simulation case underscore their impacts on restoration times, ranging from 3 min and 32 s to 6 min and 19 s. In contrast, power is not restored in an area in one of our simulation cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Recent Improvements of the SNS Extraction Kicker Power Supplies

A total of 14 extraction kickers., with one as the hot spare., are in service to extract protons out of the storage ring at the SNS. The jitter issue and the short lifetime of the switches were resolved after the thyratrons were replaced with solid state switches in 2018. This paper discusses the recent improvements. Two thyristor switches suffered overheating damage in separate incidents. One was due to the oil pump failure and the other was the result of a disconnected oil hose. An ultrasonic flow meter and a fiber optic temperature monitoring system have been installed for each extraction kicker power supply. The flow meter continuously monitors the entire tank oil flow. The temperature monitor detects the thyristor switch real-time temperatures in three locations. Fault thresholds are selected so that the thyristor switches are protected from overheating damage. Alarms are configured to alert staff to take actions before faults occur. In addition., the cause of an intermittent misfire issue was identified, and the solution was implemented. Lastly., a future oscilloscope upgrade and an oil level sensor are discussed.

Tan, Yugang↗

SDN-Based Dynamic Cybersecurity Framework of IEC-61850 Communications in Smart Grid

In recent years, critical infrastructure and power grids have experienced a series of cyber-attacks, leading to temporary, widespread blackouts of considerable magnitude. Since most substations are unmanned and have limited physical security protection, cyber breaches into power grid substations present a risk. Nowadays, the susceptibility of SDN architecture to cyber-attacks has exhibited a notable increase in recent years, as indicated by research findings. This suggests a growing concern regarding the potential for cybersecurity breaches within the SDN framework. In this paper, we propose a hybrid intrusion detection system (IDS)-integrated SDN architecture for detecting and preventing the injection of malicious IEC 61850-based generic object-oriented system event (GOOSE) messages in a digital substation. Additionally, this program locates the fault’s location and, as a form of mitigation, disables a certain port. Furthermore, implementation examples are demonstrated and verified using a hardware-in-the-loop (HIL) testbed that mimics the functioning of a digital substation.

Liu, Chen-Ching [Virginia Tech] (ORCID:00000002894↗

Modeling Grid Data Flows for Transmission and Distribution Operations: Review, Design, Next Steps

Operational scenarios of the power grids grow multifold to accommodate the diverse needs of both the utilities and end consumers, and the various other stakeholders in-between. To comprehensively model and apply analytics to support objectives and business functions of grid sectors, a reliable approach to characterize and design data flows is crucial. The flows bridge business functions with communications protocols, stakeholders such as the grid actors, and data interfaces comprising different data objects. Additionally, constraints applied to the flow such as cybersecurity, trust, privacy, and ownership among others intersect these entities, requiring the delineation of their interactions under different scenarios. This paper aims to not only highlight relevant research in the space of grid data flows, but also proposes, for the transmission-distribution sector, a novel modeling approach that marries the aforementioned entities: objectives, business functions, data interfaces, communication protocols, data stakeholders, and flow constraints. It elaborates on the design philosophy and the significance of each entity within the model and applies it to an example function of fault location, isolation and service restoration (FLISR). Finally, the next steps to extend the application of this data flow model for other practical operational scenarios are discussed.

Sundararajan, Aditya [ORNL] (ORCID:000000033577854↗

Real-Time Hardware-in-the-Loop Testbed to Evaluate FLISR Implemented with OpenFMB

With the increasing complexity of the distribution smart grid architecture, algorithms such as the fault location, isolation, and service restoration (FLISR) scheme rely on robust communications that are resilient to natural and man-made adverse conditions and exhibit robustness. Existing communications infrastructure for information exchange are centralized at the distribution management system, with very little autonomy or intelligence at the grid-edge. As a first step towards achieving grid-edge self-healing, this paper aims to bridge this shortcoming by implementing a centrally coordinated rules-based FLISR scheme and integrating it with Open Field Message Bus (OpenFMB), which is a flexible publish-subscribe architecture with the potential to enable point-to-multipoint communications and is more robust and resilient to natural and man-made adverse conditions. A proof of concept is developed to validate the centrally coordinated FLISR and OpenFMB mounted on an SEL-3360 computer that interacts with a simple feeder network of five SEL-651R relays, an SEL-3530 RTAC, and a hardware-in-the-loop testbed. Results demonstrate the efficacy of this approach in enabling direct, low-latency information exchange. OpenFMB's publish-subscribe data model also opens new ways to enable grid-edge interoperability among devices of different vendors interacting with different protocols.

Sundararajan, Aditya↗

ADMS and DER Coordinated Capability Demonstrations to Assist Utilities to Increase Resilience and Reliability

The proliferation of distributed energy resources (DERs) presents opportunities and challenges to distribution grid operators. The National Renewable Energy Laboratory (NREL) and Survalent are collaborating to demonstrate advanced distribution management system (ADMS) and DER coordinated capability to assist utilities to increase resilience and reliability. ADMS and Distributed Energy Resource Management System (DERMS) Coordination for Peak Load Management (PLM). Fault Location, Isolation, and Service Restoration (FLISR) in the Presence of DERs. Grid-Edge Intelligent Distribution Automation System for Self-Healing Distribution Grids. These laboratory demonstrations use NREL's ADMS Test Bed.

ADMS↗

Studying the Impact of IBR Modeling on the Commonly Applied Transmission Line Protective Elements

It is a well-accepted fact that detailed inverter-based resource (IBR) models are needed for electromagnetic transient (EMT) studies, especially for protection studies and protection designs. However, it is not clear which modeling aspects should be included in the EMT model to accurately represent the IBR fault responses. Therefore, this paper addresses this gap by evaluating the impact of key modeling aspects (DC source, inverter model, power control, current/voltage control, and current limiting) on the response of protective relay elements both qualitatively and quantitatively. Both grid-following (GFL) and grid-forming (GFM) IBR models are comprehensively evaluated through a simplified real-world transmission network by varying the IBR modeling aspects, fault locations, and types. The insights and findings from this paper will benefit the power system protection community because this work provides modeling requirements and guidelines for IBR modeling so that correct IBR models will be used for protection scheme settings design.

grid-following inverter↗