Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fault detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Immunity-Based Aircraft Fault Detection System

In the study reported in this paper, we have developed and applied an Artificial Immune System (AIS) algorithm for aircraft fault detection, as an extension to a previous work on intelligent flight control (IFC). Though the prior studies had established the benefits of IFC, one area of weakness that needed to be strengthened was the control dead band induced by commanding a failed surface. Since the IFC approach uses fault accommodation with no detection, the dead band, although it reduces over time due to learning, is present and causes degradation in handling qualities. If the failure can be identified, this dead band can be further A ed to ensure rapid fault accommodation and better handling qualities. The paper describes the application of an immunity-based approach that can detect a broad spectrum of known and unforeseen failures. The approach incorporates the knowledge of the normal operational behavior of the aircraft from sensory data, and probabilistically generates a set of pattern detectors that can detect any abnormalities (including faults) in the behavior pattern indicating unsafe in-flight operation. We developed a tool called MILD (Multi-level Immune Learning Detection) based on a real-valued negative selection algorithm that can generate a small number of specialized detectors (as signatures of known failure conditions) and a larger set of generalized detectors for unknown (or possible) fault conditions. Once the fault is detected and identified, an adaptive control system would use this detection information to stabilize the aircraft by utilizing available resources (control surfaces). We experimented with data sets collected under normal and various simulated failure conditions using a piloted motion-base simulation facility. The reported results are from a collection of test cases that reflect the performance of the proposed immunity-based fault detection algorithm.

Dasgupta, D.↗

Real-Time Fault Location Using the Retardation Method

A new method for short-circuit fault location is proposed. The method is based on instantaneous signal measurement and its first and second derivatives, which are the novel elements of the current approach. The derivatives allow associating a precise time stamp to the occurrence of the fault. Due to retardation phenomena, the difference between the times in which a signal is registered in two detectors can be used to locate the fault. We offer several mathematical models to describe the fault. Although a description of faults in terms of a lumped circuit is useful for elucidating the methods for detecting the fault, this description will not suffice to describe the fault signal propagation; hence, a distributed models is needed, which is given in terms of the telegraph equations. Those equations were used to derive a transmission line transfer function, and an exact analytical description of the fault signal propagating in the transmission line was obtained. The analytical solution was verified both by numerical simulations and experimentally.

42 ENGINEERING↗

Seismic Imaging of the Mw 7.1 Ridgecrest Earthquake Rupture Zone From Data Recorded by Dense Linear Arrays

Abstract We analyze seismograms recorded by four arrays (B1–B4) with 100 m station spacing and apertures of 4–8 km that cross the surface rupture of the 2019 Mw 7.1 Ridgecrest earthquake. The arrays extend from B1 in the northwest to B4 in the southeast of the surface rupture. Delay times between P wave arrivals associated with ∼1,200 local earthquakes and four teleseismic events are used to estimate local velocity variations beneath the arrays. Both teleseismic and local P waves travel faster on the northeast than the southwest side of the fault beneath arrays B1 and B4, but the velocity contrast is less reliably resolved at arrays B2 and B3. We identify several 1–2 km wide low‐velocity zones with much slower inner cores that amplify S waveforms, inferred as damage zones, beneath each array. The damage zones at arrays B2 and B4 also generate fault‐zone head and trapped waves. An automated detector, based on peak ground velocities and durations of high‐amplitude waves, identifies candidate fault‐zone trapped waves (FZTWs) in a localized zone for ∼600 earthquakes at array B4. Synthetic waveform modeling of averaged FZTWs, generated by ∼30 events with high‐quality signals, indicates that the trapping structure at array B4 has a width of ∼300 m, depth of 3–5 km, S wave velocity reduction of ∼20% with respect to the surrounding rock, Q ‐value of ∼30, and S wave velocity contrast of ∼4% across the fault (faster on the northeast side). The results show complex fault‐zone internal structures (velocity contrasts and low‐velocity zones) that vary along fault strike.

Qiu, Hongrui↗

On-line diagnosis of unrestricted faults

A formal model for the study of on-line diagnosis is introduced and used to investigate the diagnosis of unrestricted faults. A fault of a system S is considered to be a transformation of S into another system S' at some time tau. The resulting faulty system is taken to be the system which looks like S up to time tau, and like S' thereafter. Notions of fault tolerance error are defined in terms of the resulting system being able to mimic some desired behavior as specified by a system similar to S. A notion of on-line diagnosis is formulated which involves an external detector and a maximum time delay within which every error caused by a fault in a prescribed set must be detected. It is shown that if a system is on-line diagnosable for the unrestricted set of faults then the detector is at least as complex, in terms of state set size, as the specification. The use of inverse systems for the diagnosis of unrestricted faults is considered. A partial characterization of those inverses which can be used for unrestricted fault diagnosis is obtained.

Meyer, J. F.↗

Fault-tolerant grid frequency measurement algorithm during transients

Many critical electric grid operations rely on accurate grid frequency measurements. Unfortunately, the measurement accuracy can be easily undermined by power system transient faults. During a power system transient fault, the power grid voltages and currents are usually highly distorted by high-frequency components. What is worse, the power grid signals could have discontinuity during some system transient faults such as phase angle jump, and the discontinuity could result in large measurement errors to state-of-the-art grid measurement algorithms. In this study, a fault-tolerant grid frequency measurement algorithm during transients is proposed. The new algorithm consists of two stages. The first stage is a transient detector, and it can detect the occurrence of system transient faults instantaneously. The second stage is the intelligent frequency estimator, and it will adapt its measurements according to the transient detector. The performance of the algorithm is evaluated under different steady-state and transient conditions. Both dependability and security of the fault-tolerant algorithm are assessed by using PSCAD simulation data and IEEE Standard test data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessment of Envelope- and Machine Learning-Based Electrical Fault Type Detection Algorithms for Electrical Distribution Grids

This study introduces envelope- and machine learning (ML)-based electrical fault type detection algorithms for electrical distribution grids, advancing beyond traditional logic-based methods. The proposed detection model involves three stages: anomaly area detection, ML-based fault presence detection, and ML-based fault type detection. Initially, an envelope-based detector identifying the anomaly region was improved to handle noisier power grid signals from meters. The second stage acts as a switch, detecting the presence of a fault among four classes: normal, motor, switching, and fault. Finally, if a fault is detected, the third stage identifies specific fault types. This study explored various feature extraction methods and evaluated different ML algorithms to maximize prediction accuracy. The performance of the proposed algorithms is tested in an emulated software–hardware electrical grid testbed using different sample rate meters/relays, such as SEL735, SEL421, SEL734, SEL700GT, and SEL351S near and far from an inverter-based photovoltaic array farm. The performance outcomes demonstrate the proposed model’s robustness and accuracy under realistic conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Surrogate oracles, generalized dependency and simpler models

Software reliability models require the sequence of interfailure times from the debugging process as input. It was previously illustrated that using data from replicated debugging could greatly improve reliability predictions. However, inexpensive replication of the debugging process requires the existence of a cheap, fast error detector. Laboratory experiments can be designed around a gold version which is used as an oracle or around an n-version error detector. Unfortunately, software developers can not be expected to have an oracle or to bear the expense of n-versions. A generic technique is being investigated for approximating replicated data by using the partially debugged software as a difference detector. It is believed that the failure rate of each fault has significant dependence on the presence or absence of other faults. Thus, in order to discuss a failure rate for a known fault, the presence or absence of each of the other known faults needs to be specified. Also, in simpler models which use shorter input sequences without sacrificing accuracy are of interest. In fact, a possible gain in performance is conjectured. To investigate these propositions, NASA computers running LIC (RTI) versions are used to generate data. This data will be used to label the debugging graph associated with each version. These labeled graphs will be used to test the utility of a surrogate oracle, to analyze the dependent nature of fault failure rates and to explore the feasibility of reliability models which use the data of only the most recent failures.

Wilson, Larry↗

Laboratory evaluation of Fecker and Loral optical IR PWI systems

A previous flight test of two electro-optical pilot warning indicators, using a flashing xenon strobe and silicon detectors as cooperative elements, pointed out several design deficiencies. The present laboratory evaluation program corrected these faults and calibrated the sensitivity of both systems in azimuth elevation and range. The laboratory tests were performed on an optical bench and consisted of three basic components: (1) a xenon strobe lamp whose output is monitored at the indicator detector to give pulse to pulse information on energy content at the receiver; (2) a strobe light attenuating optical system which is calibrated photometrically to provide simulated range; and (3) a positioning table on which the indicator system under study is mounted and which provides spatial location coordinates for all data points. The test results for both systems are tabulated.

Gorstein, M.↗

Detector verifier for circuit analyzers

Economical tool checks operation of automatic circuit analyzer. Each loop is addressed directly from analyzer console by switching internal analyzer bridge to resistance equal that of connecting cable plus specified limiting test value. Procedure verifies whether detected faults in circuit under test are actually due to analyzer malfunction. Standard-length universal test cables make it possible to shift detector tool from cable to cable without resistance compensation.

Pope, D. L.↗

Improved Charge Sensing on a SiMOS Double Quantum Dot using a Cryogenic Skipper Readout ASIC (Quandarum)

Major outstanding questions in high-energy physics such as the nature of dark matter and the existence of interactions beyond the standard model require new measurement techniques which are extremely sensitive to minute electromagnetic fields. An array of entangled spin qubits is a promising system for building novel detectors due to its combination of sensitivity and controllability. CMOS-based electron spin qubits, which have demonstrated the operational requirements for fault-tolerant quantum computing [1], offer a particular opportunity due to their compatibility with classical electronics, which allows the leveraging of decades of development of low-noise cryogenic detectors for physics. In this work, we combine a SiMOS double-quantum dot device architecture with a state-of-the-art cryoelectronic readout circuit [2-3] aimed to demonstrate improved charge readout using a single-electron transistor (SET). We identify the design characteristics for an SET that facilitate the use of on-chip classical electronics as a low-power, high-bandwidth first amplification stage and explore opportunities for sensor-readout co-design to minimize noise. This is the first of a series of steps to demonstrate high-fidelity readout of a large array of spin qubit with enough sensitivity to probe processes of interest for the investigation of beyond-standard-model physics.

Quinn, Adam [Fermilab]↗

Effects of carbon fibers on consumer products

The potential effects of carbon fibers on consumer products such as dishwashers, microwave ovens, and smoke detectors were investigated. The investigation was divided into two categories to determine the potential faults and hazards that could occur if fibers should enter the electrical circuits of the selected appliances. The categories were a fault analysis and a hazard analysis. Hazards considered were fire, flood, physical harm, explosion, and electrical shock. Electrical shock was found to be a possible occurrence related to carbon fibers. Faults were considered to be any effect on the performance of an appliance which would result in complaint or require service action.

Wise, R. A.↗

Technical Aspects of the Space Telescope Imaging Spectrograph Repair (STIS-R)

In August 2004, the Hubble Space Telescope (HST) Space Telescope Imaging Spectrograph (STIS) ceased operation, due to a failure in the Side 2 Low Voltage Power Supply (LVPS2). LVPS2 provided power to the entire instrument, including all detectors and mechanisms. Following the LVPS2 failure, a team was assembled to analyze the fault and to determine if STIS repair (STIS-R) was feasible. The team concluded that by replacing a power supply board within LVPS2, STIS could be brought back to full functionality. STIS-R will be conducted during Servicing Mission 4 (SM4), and will consist of replacing the power supply board and a new passive cooling system. STIS-R will restore full function of the instrument with one of the two redundant sides of the instrument. In this presentation, we focus on the technical aspects associated with STISR.

Rinehart, Stephen↗

A cryogenic muon tagging system based on kinetic inductance detectors for superconducting quantum processors

Ionizing radiation has emerged as a potential limiting factor for superconducting quantum processors, inducing quasiparticle bursts and correlated errors that challenge fault-tolerant operation. Atmospheric muons are particularly problematic due to their high energy and penetration power, making passive shielding ineffective. Therefore, monitoring the real-time muon flux is crucial to guide the development of alternative error-correction or mitigation strategies. We present the design, simulation, and first operation of a cryogenic muon-tagging system based on kinetic inductance detectors (KIDs), developed as a stand-alone cryogenic particle-tagging module for superconducting quantum processors. The system consists of two KIDs arranged in a vertical stack and operated at ∼20 mK. Monte Carlo simulations based on Geant4 guided the prototype design and provided reference expectations for muon-tagging efficiency and accidental coincidences due to ambient γ-rays. We observed a muon-induced coincidence rate among the top and bottom detectors of (192 ± 9) $\times\,10^{-3}$ events s$^{−1}$, in excellent agreement with the Monte Carlo prediction. The prototype achieves a muon-tagging efficiency of about 90% with negligible dead time. These results demonstrate the feasibility of operating a muon-tagging system at millikelvin temperatures and represent a key step toward the integration of cryogenic veto systems with multi-qubit chips to mitigate muon-induced errors.

Mariani, Ambra [INFN, Rome] (ORCID:000000028184857↗

Technical Aspects of the Space Telescope Imaging Spectrograph Repair (STIS-R)

In August 2004, the Hubble Space Telescope (HST) Space Telescope Imaging Spectrograph (STIS) ceased operation, due to a failure in the Side 2 Low Voltage Power Supply (LVPS2). The LVPS2 provided power to the entire instrument, including all detectors and mechanisms. The failure precluded movement of any STIS mechanism, leaving the instrument fully shuttered. The fault analysis team concluded that by replacing a board containing a new LVPS2 power supply, STIS could be brought back to full functionality. During Servicing Mission 4 (SM4), STIS-R will replace this board. STIS-R will restore full function of the instrument with one of the two redundant sides of the instrument.

Rinehart, Stephen A.↗

Intelligent neuroprocessors for in-situ launch vehicle propulsion systems health management

Efficacy of existing on-board propulsion systems health management systems (HMS) are severely impacted by computational limitations (e.g., low sampling rates); paradigmatic limitations (e.g., low-fidelity logic/parameter redlining only, false alarms due to noisy/corrupted sensor signatures, preprogrammed diagnostics only); and telemetry bandwidth limitations on space/ground interactions. Ultra-compact/light, adaptive neural networks with massively parallel, asynchronous, fast reconfigurable and fault-tolerant information processing properties have already demonstrated significant potential for inflight diagnostic analyses and resource allocation with reduced ground dependence. In particular, they can automatically exploit correlation effects across multiple sensor streams (plume analyzer, flow meters, vibration detectors, etc.) so as to detect anomaly signatures that cannot be determined from the exploitation of single sensor. Furthermore, neural networks have already demonstrated the potential for impacting real-time fault recovery in vehicle subsystems by adaptively regulating combustion mixture/power subsystems and optimizing resource utilization under degraded conditions. A class of high-performance neuroprocessors, developed at JPL, that have demonstrated potential for next-generation HMS for a family of space transportation vehicles envisioned for the next few decades, including HLLV, NLS, and space shuttle is presented. Of fundamental interest are intelligent neuroprocessors for real-time plume analysis, optimizing combustion mixture-ratio, and feedback to hydraulic, pneumatic control systems. This class includes concurrently asynchronous reprogrammable, nonvolatile, analog neural processors with high speed, high bandwidth electronic/optical I/O interfaced, with special emphasis on NASA's unique requirements in terms of performance, reliability, ultra-high density ultra-compactness, ultra-light weight devices, radiation hardened devices, power stringency, and long life terms.

Gulati, S.↗

Detection of High-impedance Arcing Faults in Radial Distribution DC Systems

High voltage, low current arcing faults in DC power systems have been researched at the NASA Glenn Research Center in order to develop a method for detecting these 'hidden faults', in-situ, before damage to cables and components from localized heating can occur. A simple arc generator was built and high-speed and low-speed monitoring of the voltage and current waveforms, respectively, has shown that these high impedance faults produce a significant increase in high frequency content in the DC bus voltage and low frequency content in the DC system current. Based on these observations, an algorithm was developed using a high-speed data acquisition system that was able to accurately detect high impedance arcing events induced in a single-line system based on the frequency content of the DC bus voltage or the system current. Next, a multi-line, radial distribution system was researched to see if the arc location could be determined through the voltage information when multiple 'detectors' are present in the system. It was shown that a small, passive LC filter was sufficient to reliably isolate the fault to a single line in a multi-line distribution system. Of course, no modification is necessary if only the current information is used to locate the arc. However, data shows that it might be necessary to monitor both the system current and bus voltage to improve the chances of detecting and locating high impedance arcing faults

Gonzalez, Marcelo C.↗

Virtually-synchronous communication based on a weak failure suspector

Failure detectors (or, more accurately Failure Suspectors (FS)) appear to be a fundamental service upon which to build fault-tolerant, distributed applications. This paper shows that a FS with very weak semantics (i.e., that delivers failure and recovery information in no specific order) suffices to implement virtually-synchronous communication (VSC) in an asynchronous system subject to process crash failures and network partitions. The VSC paradigm is particularly useful in asynchronous systems and greatly simplifies building fault-tolerant applications that mask failures by replicating processes. We suggest a three-component architecture to implement virtually-synchronous communication: (1) at the lowest level, the FS component; (2) on top of it, a component (2a) that defines new views; and (3) a component (2b) that reliably multicasts messages within a view. The issues covered in this paper also lead to a better understanding of the various membership service semantics proposed in recent literature.

Schiper, Andre↗

Whole program Adaptive Error Detection and Mitigation

Our project investigated methods to detect soft errors in computing systems. Such detection schemes must have low overheads and also generate no false positives. Our solutions focused on control-space error detection based on changing addressing schemes so that faults tend to cascade – rather than being masked. Our solutions also addressed data-space error detection by synthesizing error detectors based on rigorous floating-point error analysis.

42 ENGINEERING↗