Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “evaporation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Thermal Performance of a Multi-Evaporator Loop Heat Pipe with Thermal Masses and Thermoelectric Coolers

This paper describes thermal performance of a loop heat pipe (LHP) with two evaporators and two condensers in ambient testing. Each evaporator has an outer diameter of 15mm and a length of 76mm, and has an integral compensation chamber (CC). An aluminum mass of 500 grams is attached to each evaporator to simulate the instrument mass. A thermoelectric cooler (TEC) is installed on each CC to provide heating as well as cooling for CC temperature control. A flow regulator is installed in the condenser section to prevent vapor from going back to the evaporators in the event that one of the condensers is fully utilized. Ammonia was used as the working fluid. Tests conducted included start-up, power cycle, heat load sharing, sink temperature cycle, operating temperature control with TECs, and capillary limit tests. Experimental data showed that the loop could start with a heat load of less than 10W even with added thermal masses. The loop operated stably with even and uneven evaporator heat loads, and even and uneven condenser sink temperatures. The operating temperature could be controlled within +/- 0.5K of the set point temperature using either or both TECs, and the required TEC control heater power was less than 2W under most test conditions. Heat load sharing between the two evaporators was also successfully demonstrated. The loop had a heat transport capability of 120W to 140W, and could recover from a dry-out when the heat load was reduced. The 500-gram aluminum mass on each evaporator had a negligible effect on the loop operation. Existing LHPs servicing orbiting spacecraft have a single evaporator with an outer diameter of about 25mm. Important performance characteristics demonstrated by this LHP included: 1) Operation of an LHP with 15mm diameter evaporators; 2) Robustness and reliability of an LHP with multiple evaporators and multiple condensers under various test conditions; 3) Heat load sharing among LHP evaporators; 4) Effectiveness of TECs in controlling the LHP operating temperature; and 5 ) Effectiveness of the flow regulator in preventing vapor from going back the evaporators.

Ku, Jen-Tung↗

Optimization of lithium vapor box divertor evaporator location on NSTX-U using SOLPS-ITER

Commercial fusion reactors will be faced with extremely high divertor target heat fluxes that will require mitigation. Simulations of detachment in an NSTX-U scenario projected to have 92 MW/m 2 unmitigated peak target heat flux are presented, which reaches sub-10 MW/m 2 target heat flux using a highly dissipating lithium vapor box divertor design. The lithium vapor box is a detached divertor design which employs lithium vapor evaporation and condensation to contain lithium below the X-point. Previous SOLPS modeling has indicated a lithium vapor box can reduce the heat flux down to 10 MW/m 2 via simultaneous evaporation from the Private Flux Region (PFR) and the Common Flux Region (CFR) sides of the vapor box. It is found here that PFR evaporation has improved access to the separatrix leading to significantly more efficient power dissipation than CFR evaporation. Simulations of target evaporation with an evaporation distribution that is self-consistent with the temperature of a Capillary Porous System with Fast flowing liquid lithium (CPSF) could reach n Li / n e ~ 0.025-0.030 at the Last Closed Flux Surface (LCFS) depending on the liquid metal flow speeds and lithium sputtering yield, while PFR-side evaporation can reach acceptable heat fluxes with n Li / n e ~ 0.038 at the LCFS. However, PFR evaporator performance can be improved if the target is allowed to be hot enough such that it reflects lithium, reaching n Li / n e ~ 0.028 and reducing required lithium evaporation. Ultimately PFR evaporation and target evaporation are found to have similar ability to produce acceptable heat flux solutions with minimal upstream concentration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Surface Crust Formation Controls Evaporation Kinetics of Secondary Organic Aerosols

Gas-particle partitioning is critical for the evolution of secondary organic aerosols (SOA) in the atmosphere. SOA particles evaporate more slowly than expected at nearly size-independent rates, but the underlying mechanism remains controversial. Here, in this study, we apply kinetic multilayer modeling to simulate evaporation of α-pinene SOA, demonstrating that surface crust formation, emerging from accumulation of low-volatility compounds at the particle surface, leads to slow evaporation and reduced size dependence of the evaporation rate. While evaporation induced by decomposition of oligomers would naturally lead to size-independent evaporation rates, we observe and simulate nearly size-independent slow evaporation of polyethylene glycol mixture particles containing polymeric species that do not decompose, confirming the relevance of composition-dependent diffusivity for size-independent, slow evaporation. Slow evaporation of limonene SOA was also observed in environmental chamber experiments, and model simulations demonstrate strong surface crust formation with bulk diffusivity being depressed by up to 5 orders of magnitude compared to the inner bulk. We present experimental evidence using a surface-based mass spectrometry technique that shows that the particle surface becomes enriched in high molecular weight compounds upon evaporation of monomers. Our findings imply that viscous surface crusts may also limit the growth and chemical transformation of SOA particles, influencing their impacts on air quality and climate.

heterogeneous chemistry↗

Evaluating Enhanced Reservoir Evaporation Losses From CMIP6‐Based Future Projections in the Contiguous United States

Abstract Enhanced reservoir evaporation has become an emerging concern regarding water loss, especially when compounded with the ever‐increasing water demand. In this study, we evaluated the evaporation rates and losses for 678 major reservoirs (representing nearly 90% of total storage capacity) in the Contiguous United States over historical baseline (1980–2019), near‐term (2020–2039), and mid‐term (2040–2059) future periods. The evaporation rate was estimated using the Lake Evaporation Model (LEM), an advanced lake evaporation model that addresses both heat storage and fetch effects, driven by multi‐ensemble downscaled Coupled Model Intercomparison Projects 6 (CMIP6) projections under the SSP585 emission scenario. The results project that the evaporation loss may increase by 2.5 × 10 7 m 3 /yr through the research period (1980–2059). Among all regions, the Rio Grande is projected to have the largest increasing rate in the near‐term and mid‐term future, with values of 7.11% of 10.25%, respectively. At the seasonal scale, the most significant increase in the evaporation rate is projected during the fall. The evaporation is projected to increase faster than the streamflow over many of the regions in the southwestern US during the summer/fall, suggesting that the shortage of water will be further exacerbated. The climate models contribute the most to the variance, as compared to the other components related to the projection of evaporation losses (e.g., hydrological model, downscaling method, and historical meteorological data set). These findings demonstrate the need to consider accelerated water loss through open water evaporation in long‐term water resources planning across various spatiotemporal scales.

54 ENVIRONMENTAL SCIENCES↗

The continuous similarity model of bulk soil-water evaporation

The continuous similarity model of evaporation is described. In it, evaporation is conceptualized as a two stage process. For an initially moist soil, evaporation is first climate limited, but later it becomes soil limited. During the latter stage, the evaporation rate is termed evaporability, and mathematically it is inversely proportional to the evaporation deficit. A functional approximation of the moisture distribution within the soil column is also included in the model. The model was tested using data from four experiments conducted near Phoenix, Arizona; and there was excellent agreement between the simulated and observed evaporation. The model also predicted the time of transition to the soil limited stage reasonably well. For one of the experiments, a third stage of evaporation, when vapor diffusion predominates, was observed. The occurrence of this stage was related to the decrease in moisture at the surface of the soil. The continuous similarity model does not account for vapor flow. The results show that climate, through the potential evaporation rate, has a strong influence on the time of transition to the soil limited stage. After this transition, however, bulk evaporation is independent of climate until the effects of vapor flow within the soil predominate.

Clapp, R. B.↗

Capillary Limit in a Loop Heat Pipe with Dual Evaporators

This paper describes a study on the capillary limit of a loop heat pipe (LHP) with two evaporators and two condensers. Both theoretical analysis and experimental investigation are conducted. Tests include heat load to one evaporator only, even heat loads to both evaporators and uneven heat load to both evaporators. Results show that after the capillary limit is exceeded, vapor will penetrate through the wick of the weaker evaporator and the compensation chamber (CC) of that evaporator will control the loop operating temperature regardless of which CC has been in control prior to the event Because the evaporator can tolerate vapor bubbles, the loop may continue to work and reach a new steady state at a higher operating temperature. The loop may even function with a modest increase in the heat load past the capillary limit With a heat load to only one evaporator, the capillary limit can be identified by rapid increases in the operating temperature and in the temperature difference between the evaporator and the CC. However, it is more difficult to tell when the capillary limit is exceeded if heat loads are applied to both evaporators. In all cases, the loop can recover by reducing the heat load to the loop.

Ku, Jentung↗

Evaporation from the Southern Ocean Estimated on the Basis of AIRS Satellite Data

Evaporation plays an important role in the global water and energy cycles and, hence, in climate change. Evaporation over the Southern Ocean, where the Antarctic sea ice coverage has a large annual cycle, is poorly quantified. In this study, daily evaporation is estimated for the Southern Ocean with a sea‐ice‐specific algorithm, using surface temperature and air humidity from National Aeronautics and Space Administration's Atmospheric Infrared Sounder (AIRS), and wind speeds from Modern‐Era Retrospective Analysis for Research and Applications, Version 2 (MERRA‐2), reanalysis during 2003–2016. An uncertainty of 34% was found in the evaporation product. The results indicate that annual evaporation has considerable interannual and regional variability, but with a decreasing trend during the study period over most of the Southern Ocean. There are, however, areas where evaporation has increased, specifically in the Ross Sea in winter and summer, with smaller positive trends in spring and fall. Overall, the changes in the difference between the surface specific humidity and the air specific humidity, and to a much lesser extent in the wind speed, are the main drivers for the changes in evaporation throughout the year. During spring and fall months, changes to the sea ice cover, which alter the surface specific humidity, are the main drivers for the change, but in summer and winter the main driver is the air‐specific humidity. Air masses originating from the Antarctic continent (south) are associated with cold and dry conditions, which increase evaporation, whereas air masses from lower latitudes in the Southern Ocean (north) are associated with warm and moist conditions, decreasing evaporation. Comparisons with other reanalysis evaporation products produce similar trends, although annual averages differ.

Boisvert, Linette↗

Organic Evaporation and Oxidation Testing in Support of Hanford Sample-and-Send

The Hanford site has approximately 56 million gallons of radioactive mixed waste stored in 177 underground storage tanks. The Hanford Waste Treatment and Immobilization Plant (WTP) is being built to treat and immobilize the tank waste. The baseline method for immobilization of Low Activity Waste (LAW) through the WTP is vitrification, but additional immobilization capacity is needed to supplement the initial LAW melters. An alternative cementitious waste form is being investigated for that future immobilization method to supplement vitrification. However, one impediment to a cementitious waste form is the presence of Land Disposal Restricted (LDR) organic chemicals in tank waste. This work evaluates potential avenues to eliminate that impediment to permit possible use of a cementitious waste form and work towards a decision whether additional LDR organic pretreatment would be required. Savannah River National Laboratory (SRNL) performed testing using simulants to examine evaporation as a method to remove some prevalent organics from LAW. Spiking the caustic LAW simulant with selected regulated organic chemicals found one that clearly decomposes because of caustic instability. Oxidation testing of other organic chemicals found some LDR organics degrade as desired and others are stable in the presence of peroxide and permanganate. In addition to studies with simulants, a literature review was performed to evaluate radiological stability of LDR organics. Descriptions of the experimental details, equipment, and results are included in this report. Evaporation testing consisted of preparing the LAW simulant, spiking that simulant with organic chemicals, and evaporating the mixture via differential distillation. The apparatus was a laboratory-scale vacuum evaporator operated at 60 ±5 torr absolute (vacuum evaporation) and also at atmospheric pressure. The LAW simulant represented the liquid expected to be retrieved from the Hanford tank farms at approximately 4.0 M [Na + ] total sodium ion concentration. The concentration of the organic chemicals added was significantly higher than typically found in the tank waste samples since the higher levels were necessary to assist in analytical measurement and tracking of the spiked species. Organic chemicals were chosen for the work with a consideration of how their volatility compares with that of methanol. This was done by comparing the ratio of the pure water Henry’s law coefficient (K h ) of methanol to that of the compound in question (hereafter termed the K h ratio), where ratios above unity indicated less volatility than methanol. Methanol was chosen because it is a common regulated chemical with relatively low volatility but which has been removed by evaporation in previous laboratory work. While organic separation results depend on evaporator design, laboratory experiments verified that organic partitioning to the overhead condensate stream by evaporation is a practical process. The work reported here found difficulties in quantitative analysis of the organic chemicals in aqueous samples. Most of the time there was insufficient analysis to close a mass balance for evaporator runs, but qualitative evidence of carryover was obtained. The methods were also able to show whether organic chemicals were susceptible or resistant to solution oxidation in permanganate or hydrogen peroxide tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mineral Scaling in 3D Interfacial Solar Evaporators–A Challenge for Brine Treatment and Lithium Recovery

In this work, we analyzed the effects of mineral scaling on the performance of a 3D interfacial solar evaporator, with a focus on the cations relevant to lithium recovery from brackish water. The field has been rapidly moving toward resource recovery applications from brines with higher cation concentrations. However, the potential complications caused by common minerals in these brines other than NaCl have been largely overlooked. Therefore, in this study, we thoroughly examined the effects of two common cations (calcium and magnesium) on the long-term solar evaporation performance of a 3D graphene oxide stalk. The 3D stalk can achieve an evaporation flux as high as 17.8 kg m –2 h –1 under one-sun illumination, and accumulation of NaCl on the stalk surface has no impact. However, the presence of CaCl 2 and MgCl 2 significantly reduces the evaporative flux even in solutions lacking scale-forming anions. A close examination of scale formation during long-term evaporation experiments revealed that CaCl 2 and MgCl 2 tend to precipitate out within the stalk, thus blocking water transport through the stalk and significantly dropping the evaporation rates. These findings imply that research attention is needed to modify and optimize the internal water transport channels for 3D evaporators. Additionally, we emphasize the importance of testing realistic mixtures–including prominent divalent cations– and testing long-term operations in interfacial solar evaporation research and investigating approaches to mitigate the negative impacts of divalent cations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaporative segregation in 80 percent Ni-20 percent Cr and 60 percent Fe-40 percent Ni alloys

The phenomenon of evaporative segregation in binary alloys has been investigated through a study of some experimental evaporation data relating to the Ni-Cr and Ni-Fr systems. In normal evaporation it is assumed that (1) the evaporating alloy is always homogeneous, (2) the vapor is instantly removed, and (3) the alloy follows Raoult's law. The solutions of the evaporation equations for the two most important cases are presented and experimental data are analyzed with these equations. The difference between observed and calculated values of evaporation constants lies within one order of magnitude. This is surprising because of the major assumptions stated above. Experimental results have shown that the evaporation time and final solute concentration are logarithmically related, further supporting our evaporation equations. It is further shown that neglecting the nonlogarithmic term in these evaporation equations may introduce considerable errors in the analysis.

Mukherjee, J. L.↗

Seasonal and Interannual Variations of Evaporation and their Relations with Precipitation, Net Radiation, and Net Carbon Accumulation for the Gediz Basin Area

A model combining the rate of carbon assimilation with water and energy balance equations has been run using satellite and ancillary data for a period of 60 months (January 1986 to December 1990). Calculations for the Gediz basin area give mean annual evaporation as 395 mm, which is composed of 45% transpiration, 42% soil evaporation and 13% interception. The coefficient of interannual variation of evaporation is found to be 6%, while that for precipitation and net radiation are, respectively, 16% and 2%, illustrating that net radiation has an important effect in modulating interannual variation of evaporation. The mean annual water use efficiency (i.e., the ratio of net carbon accumulation and total evaporation) is ca. 1 g/sq m/mm, and has a coefficient of interannual variation of 5%. A comparison of the mean water use efficiency with field observations suggests that evaporation over the area is utilized well for biomass production. The reference crop evaporation for irrigated areas has annual mean and coefficient of variation as, respectively, 1176 mm and 3%. The total evaporation during three summer months of peak evaporation (June-August) is estimated to be about 575 mm for irrigated crops like maize and cotton. Seasonal variations of the fluxes are presented.

Choudhury, Bhaskar J.↗

Sensitivity of Spacebased Microwave Radiometer Observations to Ocean Surface Evaporation

Ocean surface evaporation and the latent heat it carries are the major components of the hydrologic and thermal forcing on the global oceans. However, there is practically no direct in situ measurements. Evaporation estimated from bulk parameterization methods depends on the quality and distribution of volunteer-ship reports which are far less than satisfactory. The only way to monitor evaporation with sufficient temporal and spatial resolutions to study global environment changes is by spaceborne sensors. The estimation of seasonal-to-interannual variation of ocean evaporation, using spacebased measurements of wind speed, sea surface temperature (SST), and integrated water vapor, through bulk parameterization method,s was achieved with reasonable success over most of the global ocean, in the past decade. Because all the three geophysical parameters can be retrieved from the radiance at the frequencies measured by the Scanning Multichannel Microwave Radiometer (SMMR) on Nimbus-7, the feasibility of retrieving evaporation directly from the measured radiance was suggested and demonstrated using coincident brightness temperatures observed by SMMR and latent heat flux computed from ship data, in the monthly time scale. However, the operational microwave radiometers that followed SMMR, the Special Sensor Microwave/Imager (SSM/I), lack the low frequency channels which are sensitive to SST. This low frequency channels are again included in the microwave imager (TMI) of the recently launched Tropical Rain Measuring Mission (TRMM). The radiance at the frequencies observed by both TMI and SSM/I were simulated through an atmospheric radiative transfer model using ocean surface parameters and atmospheric temperature and humidity profiles produced by the reanalysis of the European Center for Medium Range Weather Forecast (ECMWF). From the same ECMWF data set, coincident evaporation is computed using a surface layer turbulent transfer model. The sensitivity of the radiance to evaporation over various seasons and geographic locations are examined. The microwave frequencies with radiance that are significant correlated with evaporation are identify and capability of estimating evaporation directly from TMI will be discussed.

Liu, Timothy W.↗

EXPERIMENTAL ANALYSIS OF SINGLE EVAPORATION TUBE UTILIZING SINTERED COPPER PARTICLE WICKING STRUCTURES

Wicking structures have been widely used within passive heat transfer devices with high heat fluxes, such as heat pipes, to enhance their thermal performance. While wicking structures promote capillary pumping of the working fluid as well as thin film evaporation, they can result in capillary evaporation and further enhances the evaporation heat transfer. In this study, a 0.5 mm thick layer of 105 microns sintered copper particles was added to the inner wall of a copper tube, aiming to enhance the heat transfer characteristics by taking advantage of capillary evaporation. Acetone was chosen as the working fluid, and the performance of an evaporation tube was tested for power inputs of 10, 30, 50, and 70 W. For each power input, trials were run at inclination angles varying from -90° and 90° to investigate the capillary effects. The temperature measurements showed that the temperature distribution along the evaporation tube is always downward sloping, meaning the temperature at the fluid inlet is larger than the outlet. Interestingly, the surface temperature at some locations is less than the outlet temperature, indicating the effect of capillary evaporation. In addition, a theoretical investigation was performed to investigate the effects of the particle size on the thermal performance of the evaporation tube and found that particle sizes affect capillary evaporation.

Wang, Pengtao↗

Evaporation of Water Nanodroplets on Heated Surfaces: Does Nano Matter?

While experiments and continuum models have provided a relatively good understanding of the evaporation of macroscopic water droplets, elucidating how sessile nanodroplets evaporate is an open question critical for advancing nanotechnological applications where nanodroplets can play an essential role. In this study, using molecular dynamics simulations, we find that evaporating nanodroplets, in contrast to their macroscopic counterparts, are not always in thermal equilibrium with the substrate and that the vapor concentration on the nanodroplet surface does not reach a steady state. As a result, the evaporative behavior of nanodroplets is significantly different. Regardless of hydrophobicity, nanodroplets do not follow conventional evaporation modes but instead exhibit dynamic wetting behavior characterized by huge, non-equilibrium, isovolumetric fluctuations in the contact angle and contact radius. For hydrophilic nanodroplets, the evaporation rate, controlled by the vapor concentration, decays exponentially over time. Hydrophobic nanodroplets follow stretched exponential kinetics arising from the slower thermalization with the substrate. The evaporative half-lifetime of the nanodroplets is directly related to the thermalization time scale and therefore increases monotonically with the hydrophobicity of the substrate. Finally, the evaporative flux profile along the nanodroplet surface is highly nonuniform but does not diverge at the contact line as the macroscopic continuum models predict.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Experimental Investigation of Sintered Particle Effect on Heat Transfer Performance in an “Annular Flow” Evaporation Tube

Wicking structures have been widely used within passive heat transfer devices with high heat fluxes, such as heat pipes, to enhance their thermal performance. While wicking structures promote capillary pumping of the working fluid and thin film evaporation, they can result in capillary evaporation and further enhance the evaporation heat transfer. In this study, a 0.5 mm thick layer of 105 µm sintered copper particles was added to the inner wall of a copper tube, aiming to form an “annular flow” and enhance the heat transfer characteristics by taking advantage of thin film and capillary evaporation. Acetone was chosen as the working fluid, and the performance of an evaporation tube was tested for power inputs of 10, 30, 50, and 70 W. For each power input, trials were run at inclination angles varying from -90 deg to 90 deg to investigate the capillary effects. The temperature measurements showed that the temperature distribution along the evaporation tube is always downward sloping, meaning the temperature at the fluid inlet is larger than the outlet. In conclusion, results show that an “annular flow” formed by a thin layer of sintered particles can promote thin film and capillary evaporation and, therefore, boost the evaporation heat transfer coefficient.

42 ENGINEERING↗

Evaporative water loss of 1.42 million global lakes

The evaporative loss from global lakes (natural and artificial) is a critical component of the terrestrial water and energy balance. However, the evaporation volume of these water bodies—from the spatial distribution to the long-term trend—is as of yet unknown. Here, using satellite observations and modeling tools, we quantified the evaporation volume from 1.42 million global lakes from 1985 to 2018. We find that the long-term average lake evaporation is 1500 ± 150 km 3 year -1 and it has increased at a rate of 3.12 km 3 year -1 . The trend attributions include an increasing evaporation rate (58%), decreasing lake ice coverage (23%), and increasing lake surface area (19%). While only accounting for 5% of the global lake storage capacity, artificial lakes (i.e., reservoirs) contribute 16% to the evaporation volume. Our results underline the importance of using evaporation volume, rather than evaporation rate, as the primary index for assessing climatic impacts on lake systems.

54 ENVIRONMENTAL SCIENCES↗

Evaporation and Accompanying Isotopic Fractionation of Sulfur from FE-S Melt During Shock Wave Heating

Chondrules probably formed by melting and subsequent cooling of solid precursors. Evaporation during chondrule melting may have resulted in depletion of volatile elements in chondrules. It is known that kinetic evaporation, especially evaporation from a melt, often leads to enrichment of heavy isotopes in an evaporation residue. However, no evidence for a large degree of heavy-isotope enrichment has been reported in chondrules for K, Mg, Si, and Fe (as FeO). The lack of isotopic fractionation has also been found for sulfur in troilites (FeS) within Bishunpur (LL3.1) and Semarkona (LL3.0) chondrules by an ion microprobe study. The largest fractionation, found in only one grain, was 2.7 +/- 1.4 %/amu, while all other troilite grains showed isotopic fractionations of <1 %/amu. The suppressed isotopic fractionation has been interpreted as results of (i) rapid heating of precursors at temperatures below the silicate solidus and (ii) diffusion-controlled evaporation through a surrounding silicate melt at temperatures above the silicate solidus. The kinetic evaporation model suggests that a rapid heating rate of >10(exp 4)-10(exp 6) K/h for a temperature range of 1000-1300 C is required to explain observed isotopic fractionations. Such a rapid heating rate seems to be difficult to be achieved in the X-wind model, but can be achieved in shock wave heating models. In this study, we have applied the sulfur evaporation model to the shock wave heating conditions of to evaluate evaporation of sulfur and accompanying isotopic fractionation during shock wave heating at temperatures below the silicate solidus.

Tachibana, S.↗

Heat Load Sharing in a Loop Heat Pipe with Multiple Evaporators and Multiple Condensers

This paper describes the heat load sharing function among multiple parallel evaporators in a loop heat pipe (LHP). Each evaporator can be attached to an instrument. In the normal mode of operation, each evaporator will cool the corresponding instrument by absorbing the waste heat. When an instrument is turned off, the attached evaporator can keep it warm by receiving heat from other evaporators serving the operating instruments. This is referred to as heat load sharing. The fact that the wicks in the powered evaporators will develop capillary pressure to force the vapor that is being generated to flow to cold locations where the pressure is lower leads to the conclusion that heat load sharing is an inherent function of an LHP with multiple evaporators. This paper presents a theoretical basis of the LHP heat load sharing operation, and experimental results from ground tests of an LHP with two evaporator and two condensers. Factors that affect the amount of heat being shared are also discussed.

Ku, Jentung↗