Mechanical behavior of carbon-fiber reinforced- epoxy composites.
Carbon fiber reinforcing and epoxy resin composites mechanical properties for NOL ring, belt, cylinder and tube-column specimens
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Carbon fiber reinforcing and epoxy resin composites mechanical properties for NOL ring, belt, cylinder and tube-column specimens
The difference in thermal expansion characteristics of epoxy matrices and graphite fibers can produce significant residual stresses in the fibers during curing of composite materials. Tests on single fiber glass-epoxy and graphite-epoxy composite specimens were conducted in which the glass and graphite fibers were preloaded in tension, and the epoxy matrix was cast around the fibers. The fiber tension was monitored while the matrix was placed around the fiber and subjected to the temperature-time curing cycle. Two mechanisms responsible for producing stress in embedded fibers were identified as matrix thermal expansion and contraction and matrix cure shrinkage. A simple analysis based on the change in fiber tension during the curing cycle was conducted to estimate the produced stresses. Experimental results on single fiber glass- and graphite-epoxy composites show that the fiber was subjected to significant tensile stresses when the temperature was raised from the first to the second dwell period. When initial fiber pretension is about 60 percent of the fiber failure load, these curing-induced stresses can cause tensile fracture of the embedded fiber.
The damping properties of a graphite epoxy composite material (used in the construction of the Hubble Space Telescope) are measured under a variety of conditions in a vacuum chamber to simulate conditions in space. An improved method is proposed which utilizes several points of the response curve near a resonance to estimate the damping ratio and the undamped resonance frequency. The damping of a graphite epoxy tube is monitored for four weeks to study moisture desorption and temperature effects. A significant variation is observed in the damping ratio with temperature.
Radiation effects on engineering properties, dimensional stability, and chemistry on state of the art composite systems were characterized. T300/934 graphite-epoxy composite was subjected to 1.0 MeV electron radiation for a total dose of 1.0 x 10(10) rads at a rate of 5.0 x 10(7) rads/hour. This simulates a worst case exposure equivalent to 30 years in space. Mechanical testing was performed on he 4-ply unidirectional laminates over the temperature range of -250 F (116K) to +250 F (394K). A complete set of in-plane tensile elastic and strength properties were obtained (E sub 1, E sub 2, nu sub 12, G sub 12, X sub T, Y sub T, and S). In addition electron microscopy was used to study and analyze the fracture surfaces of all specimens tested. Results indicate that little difference in properties is noted at room temperature, but significant differences are observed at both low and elevated temperatures.
Scaling effects in the large deflection response of graphite-epoxy composite beams was investigated. Eight different scale model beams ranging from 1/6 to full-scale were subjected to an eccentric axial compressive load to promote large bending deformations and failures. Beams having laminate stacking sequences including unidirectional, angle ply, cross ply, and quasi-isotropic were tested to examine a wide variety of composite response and failure modes. The model beams were loaded under scaled test conditions until catastrophic failure. Data acquired included load, end displacement, and strain measurements, and qualitative failure measurements. The experimental data is compared to a large rotation beam analysis and a finite element model analysis. Results from the tests indicate that the beam response becomes nonlinear. Failure modes are consistent between scale models within a laminate family, however, a significant scale effect is observed in strength of the scaled beams.
The effects of oxidative surface treatments and differences in resin crack sensitivity on the tensile properties of carbon-epoxy composites have been investigated. A comparison of the fracture mechanisms for two different fiber batches was made in both model and engineering composites, using unmodified and modified epoxy resin. It has been observed that two distinct characteristics occur in the fracture surfaces of most engineering composites; first, fibers which fracture at the surface result in cleavage failure and, second, those which have fractured elsewhere and pulled out. A detailed discussion of these observations is contained in this paper.
A study of the effects of thermal environment and microcracking in graphite epoxy composites was made. Research indicates that microcracking does affect the thermal expansion of composite laminates. The amount of reduction in thermal expansion was a function of the crack density. A maximum reduction of approximately 25% occurred in a quasi-isotropic specimen with a crack density of 2.05 mm 1 in the 90 deg plies. Laminate analysis with appropriate reductions in E sub 2 and Alpha sub 2 of the damaged plies appears to be capable of modeling the observed
Fracture and notch strength tests of graphite-epoxy composites showed that unidirectional lay-ups generally exhibit longitudinal cracking before failure, whereas multidirectional lay-ups fail transversely with little longitudinal cracking. A simple qualitative analysis suggested that the higher matrix shear stresses in unidirectional materials cause the longitudinal cracking, and that this cracking was responsible for the high toughness of unidirectional composites. In a series of comparative tests, the interlaminar strength of multi-directional composites was reduced by placing perforated Mylar films between laminae; tests on notched and slotted specimens showed that the interlaminar films promoted delamination and longitudinal cracking near the notches and that, as a result, toughness, notch strength, and impact strength were substantially increased.
A comparative evaluation of some of the mechanical properties of woven graphite-epoxy composites are discussed. In particular, the types of weaves and the resin contents were chosen for comparison. The types of weaves selected are plain weave, satin weave, and tridirectional weave. The composites made of the fabrics are compared to composites made from unidirectional tapes under static and fatigue loading. During static loading, acoustic emission events were monitored. Also, examinations of fracture surfaces and polished sections both away from the fracture surface, and of virgin specimens under an electron microscope are discussed.
A comparative evaluation of some of the mechanical properties of woven graphite-epoxy composites have been discussed in this report. In particular the types of weaves and the resin contents have been chosen for comparison. The types of weaves selected are plain weaves, satin weave and tri-directional weave. The composites made of these fabrics have been compared to composites made from unidirectional tapes under static and fatigue loading. During static loading acoustic emission events have been monitored. Also, examinations of fracture surface and polished sections of specimens away from the fracture surface under an electron microscope have been discussed.
The existence of five different waves fronts in a unidirectional graphite fiber reinforced epoxy composite with energy flux propagation at the angle of 60 deg with respect to the fiber direction is verified by measuring their corresponding group and phase velocities of longitudinal and shear waves using the through transmission technique. The experimental and theoretical values of phase velocities show excellent agreement for all three modes of wave propagation. It is also verified that the maximum output voltage amplitude is obtained when the line joining the centers of the transmitting and receiving transducers is parallel to the energy propagation direction defined by the deviation angle.
The influence of material volume on the transverse tensile strength of AS4/3501-6 graphite epoxy composites was investigated. Tensile tests of 90 degree laminates with 3 different widths and 5 different thicknesses were conducted. A finite element analysis was performed to determine the influence of the grip on the stress distribution in the coupons and explain the tendency for the distribution of failure locations to be skewed toward the grip. Specimens were instrumented with strain gages and extensometers to insure good alignment and to measure failure strains. Data indicated that matrix dominated strength properties varied with the volume of material that was stressed, with the strength decreasing as volume increased. Transverse strength data were used in a volumetric scaling law based on Weibull statistics to predict the strength of 90 degree laminates loaded in three point bending. Comparisons were also made between transverse strength measurements and out-of-plane interlaminar tensile strength measurements from curved beam bending tests. The significance of observed scale effects on the use of tests for material screening, quality assurance, and design allowables is discussed.
Eight-ply (0, + or - 45, 0)s laminates of Hercules AS/3501-6 graphite epoxy composite are fabricated using various cure pressures ranging from 0.52 to 0.86 MPa and cure temperatures ranging from 150 C to 200 C. In general, the minimum composite void volume fraction is obtained at a cure temperature of 175 C and a cure pressure of 0.86 MPa, or at 200 C and 0.86 MPa. The ultrasonic attenuation at 4 MHz was found to correlate with the composite void volume fraction. Composite specimens were tested in flexural fatigue. Beyond 10,000 fatigue cycles, the ultrasonic attenuation at 4 MHz was found to increase and the flexural stiffness was found to decrease. The ultrasonic attenuation at 4 MHz of the as-fabricated composite can be correlated with the number of fatigue cycles to failure.
The kinetics of polymerization/curing of a filament-wound composite epoxy resin consisting of an 80/20 DGEBA/DGEBD blend and an MDA/m-PDA blend (Tonox 60/40) was studied at various temperatures and at amine epoxy ratios between 1.1 and 4.4 by means of Fourier-transform (FT) IR and bulk viscosity measurements. The activation energy for the polymerization/curing reaction using an amine/epoxy ratio of 1.1 was 11.9 kcal/mole, in agreement with a previous value. The FT-IR conversion-time plots were fitted to a kinetic expression containing two rate constants with activation energies of 13.7 and 10.0 kcal/mole. The bulk viscosity followed the Williams et al. (1955) equation, with a Di Benedetto (1965) expression for the glass transition temperature.
A method for measuring the acoustic velocity in a thin sheet of a graphite epoxy composite (GEC) material was investigated. This method uses two identical acoustic-emission (AE) sensors, one to transmit and one to receive. The delay time as a function of distance between sensors determines a bulk velocity. A lightweight fixture (balsa wood in the current implementation) provides a consistent method of positioning the sensors, thus providing multiple measurements of the time delay between sensors at different known distances. A linear fit to separation, x, versus delay time, t, will yield an estimate of the velocity from the slope of the line.
Results of an exploration of the relationship between ultrasonic attenuation and fatigue survivability of graphite fiber epoxy composites fabricated under different cure conditions are reported. A total of 9 27 x 40 cm eight-ply graphite epoxy laminated specimens were formed, and fatigue tests were run on five partial samples at 73.5 N varying at 30 Hz, with tests ending at a 1.27 cm deflection. A pulsed oscillator generated sinusoidal waves and transducers recorded the passage of the ultrasonic waves for display on oscilloscopes. Cure pressures ranged from 0.52-0.85 MPa and cure temperatures were in the 150-200 C interval. Ultrasonic through-transmission at 4 MHz was performed prior to and during fatigue testing. The minimum void volume fraction occurred at 175 C and 0.86 MPa. The flexural stiffness decreased with the number of fatigue cycles past 10,000, when the attenuation also increased. Correlations were found between the 4.0 MHz signal attenuation and the void volume fraction, and between the number of fatigue cycles to failure and the 4.0 MHz signal attenuation.
The effects of water and ice on the strength and fracture toughness of boron-epoxy composites with polyurethane intermittent bonding have been investigated. Neither simple soaking in water nor soaking followed by freezing and thawing have marked effects on the strength of the fully-coated composites, but they have disastrous effects on the uncoated composites. Toughness is affected only marginally, with some small reductions in the fully-coated samples, and with essentially no effect on the uncoated composites. An analysis is presented which explains adequately the experimental strength and toughness results obtained, and which is based on an argument that water absorption reduces the interfacial shear strength only of the uncoated areas and not those regions coated by the polyurethane varnish. The results indicate that the advantages of appropriate intermittent bonding (i.e., high strength combined with high toughness) are retained in wet conditions so that such composites may be favorably used in such adverse environmental conditions.
The frequencies and nodal patterns of a square thick plate of unidirectional fiberglass epoxy composite are measured experimentally. The constituent material is transversely isotropic. The plate is transversely excited at the center of the upper face, its resonant frequencies in the frequency range of 3 kHz to 21.73 kHz are detected and the measured nodal patterns are sketched.