At least 37 records · Page 2

Utah FORGE 5-2557: Role of Fluid and Temperature in Fracture Mechanics and Couples THMC Processes for Enhanced Geothermal Systems - 2024 Annual Workshop Presentation

This is a presentation on the Role of Fluid and Temperature in Fracture Mechanics and Couples THMC Processes for Enhanced Geothermal Systems by Purdue University, presented by Laura Pyrak-Nolte. This video slide presentation describes the development and validation of a macroscopic model that can account for local deformation/friction behavior, seismic/aseismic behavior, chemical reactions, and determine the adequacy of classic Coulomb failure vs. rate-and-state friction. This presentation was featured in the Utah FORGE R&D Annual Workshop on August 13, 2024.

15 GEOTHERMAL ENERGY↗

Experimental investigation of flow distribution in enhanced geothermal systems with deep eutectic solvent

Geothermal energy has been recognized as a valuable alternative to fossil fuels and nuclear power, as it is renewable and reliable. Enhanced Geothermal Systems (EGSs) have the potential to expand geothermal energy production by enabling access to previously untapped geothermal resources. Geothermal short-circuiting poses a significant challenge to EGS development, leading to reduced heat extraction. Deep Eutectic Solvent (DES) exhibits favorable thermal and rheological properties, making it a candidate for geothermal applications. Here, this paper examines Choline Chloride-Based Deep Eutectic Solvent (DES) as a working fluid in geothermal applications and its potential to mitigate geothermal short-circuiting. Hydraulic experiments using a dual fracture flow loop were conducted at high temperatures. The results showed that DES exhibited higher differential pressure behavior compared to water. Flow distribution results revealed that DES enhances flow allocation within the small fracture, particularly when a temperature difference exists between fractures. Specifically, DES increased flow distribution by an average of 11% when the temperature difference was 85°C, and by 13% when the difference was 45°C, relative to water. These findings suggest that DES responds to thermal fracture differences, making it a potential remedy to address geothermal short-circuiting.

15 GEOTHERMAL ENERGY↗

Development of Ionic Based Fluid to Improve Fluid Hydraulics in Enhanced Geothermal Systems

This research advances the field of geothermal energy by developing and evaluating novel fluid systems designed explicitly for high-temperature subsurface environments to enhance fracture flow distribution. The project integrates chemical synthesis, environmental assessment, rheological testing, microfluidic analysis, and reservoir-scale laboratory testing and analysis to identify optimal ionic and nonionic fluids for Enhanced Geothermal Systems (EGS).

15 GEOTHERMAL ENERGY↗

Computed Tomography Scanning and Geophysical Measurements of the Enhanced Geothermal Systems (EGS) Collab SURF Core

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize core from 8 wells from the Enhanced Geothermal Systems (EGS) Collab project located in the Sanford Underground Research Facility’s (SURF) 4850 level. The work in this report falls in Experiment 1 in a three-phase experiment, with the primary purpose to increase understanding of hydraulic fracturing. The primary impetus of this work is a collaboration between U.S. Department of Energy (DOE) and the EGS Collab. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/surf-collab-core. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. None of the equipment used was suitable for direct visualization of the pore space in the core, although fractures and discontinuities were detectable with the methods tested. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis as well as fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy related examinations traditionally performed at NETL.

47 OTHER INSTRUMENTATION↗

Energy to Communities Program Short Introduction: Evaluation of Enhanced Geothermal System for Cornell District Heating [Slides]

Through the U.S. Department of Energy's Energy to Communities (E2C) program, NLR, other national laboratory experts, and select organizations provide Expert Match - free, short-term technical assistance to address near-term energy challenges and questions. Expert Match is for community stakeholders who have decision-making power or influence in their community but need access to additional energy expertise to inform key upcoming decisions. This Expert Match request supported Cornell University (Itaca, NY) community efforts in developing Enhanced Geothermal System (EGS) reservoir performance, by simulating fracture flow to estimate pressure drop, flow distribution, and heat extraction efficiency in fractured rock. Thermal drawdown modeling was used to assess long-term resource sustainability, while system optimization studies refined key parameters such as well configuration and flow rate to improve overall reservoir efficiency.

15 GEOTHERMAL ENERGY↗

Alternative, Less Water-Intensive, Fracturing Fluids for Enhanced Geothermal Systems

Four fracturing fluids; water, CO2, CO2 with water, and CO2 with an aqueous solution of a CO2-reactive polymer, poly(allylamine) (PAA, 1wt%) were evaluated using a high-temperature true-triaxial fracturing apparatus and ½ foot side granite cubic samples. All three CO2-based fracturing fluids, CO2, CO2 with water, and CO2 with aqueous PAA fractured granite at higher breakdown pressures, high transient flow rates, and produce higher-conductivity fractures as compared to water. Additionally, faster pressurization rates with CO2-based fracturing fluids (obtained when fracturing at constant flow rate mode) are found to be associated with higher fracture conductivities. When partially saturating the rock sample with PAA solution followed by fracturing with CO2, the volume expansion caused by CO2-induced cross-linking of PAA leads to a faster pressure increase due to the associated stress generated and increase in viscosity. It was also found that CO2 as a fracturing fluid injected in hot dry rock (HDR) attain the highest fracture conductivity only when injected at very high flow rates, followed very closely by the CO2/PAA fracturing fluid system that generates fractures with, on average, similarly high conductivity values though independently of injection flow rate and using 1/6 of the mass of CO2 as compared to CO2 in HDR. Breakdown pressures were also similar for CO2 stimulation in HDR and CO2/PAA fluid system under identical injection flow rates. It is concluded that CO2 (when injected in HDR) and CO2/PAA are the fluids of choice for stimulation of granitic rock samples under the studied geothermal P/T conditions. CO2/PAA, however, offer the following three additional advantages; 1) it requires significantly lower volumes of CO2, 2) fracture permeability is independent of injection flow rate, and 3) the reversible (previously reported) viscosity increase is beneficial to transport proppants if they are ever developed enhanced geothermal systems.

Jian, Guoqing↗

Evaluation of sintered bauxite proppant for binary enhanced geothermal systems

Abstract Solid granular proppant particles are widely used in oil and gas development to sustain permeability through fractures after hydraulic stimulation. Similar proppants are of interest for geothermal applications where the goal of sustaining permeability is the same, but the harsh geothermal environment risks rapid proppant degradation that will reduce fracture permeability. Here, we present proppant conductivity experiments using saw cut granite, tensile fractured granite, and aluminum control specimens packed with sintered bauxite ceramic proppants at concentrations of 0.0, 0.1, and 1.0 kg/m 2 . Simulated geothermal conditions included temperatures up to 130 °C and normal closure stresses up to 60 MPa. Compared to unpropped specimens, peak fracture conductivity enhancement was up to 6 orders of magnitude. At simulated geothermal conditions, proppants were able to sustain fracture conductivity over 60 h, but chemical dissolution and decreasing permeability over time were evident. Irreversible conductivity reductions with crushing and embedment of proppants during loading stages were also observed. Overall, sintered bauxite proppant remains a promising option for low-temperature binary-cycle enhanced geothermal systems.

58 GEOSCIENCES↗

Selecting Appropriate Model Complexity: An Example of Tracer Inversion for Thermal Prediction in Enhanced Geothermal Systems

Abstract A major challenge in the inversion of subsurface parameters is the ill‐posedness issue caused by the inherent subsurface complexities and the generally spatially sparse data. Appropriate simplifications of inversion models are thus necessary to make the inversion process tractable and meanwhile preserve the predictive ability of the inversion results. In this study, we investigate the effect of model complexity on fracture aperture inversion and thermal performance prediction in a field‐scale EGS model. Principal component analysis was used to map the aperture field to a low‐dimensional latent space. The complexity of the inversion model was quantitatively represented by the percentage of total variance in the original aperture fields preserved by the latent space. Tracer, pressure and flow rate data were used to invert for fracture aperture through an ensemble‐based inversion method, and the inferred aperture field was used to predict thermal performance. With an over‐simplified aperture model, ensemble collapse occurred. The inverted aperture models failed to resolve necessary flow and transport features, leading to a biased thermal performance prediction. A complex aperture model involved excessive features and was prone to overinterpreting the inversion data. Both the tracer/pressure/flow rate data reproduction and thermal prediction showed significant uncertainties, making it difficult to properly estimate long‐term thermal performance. Fortunately, our results indicate that there exists an appropriate model complexity which can simultaneously match inversion data and predict thermal performance with an acceptable uncertainty. The quality of the fit of tracer data appears to be a useful indicator of such an appropriate model complexity.

15 GEOTHERMAL ENERGY↗

Mixed-Mechanism Stimulation Enabled Enhanced Geothermal Systems (CRADA FP00007509 Final Report)

In this project, we aimed to develop a robust, novel EGS design that would enable broad deployment of geothermal energy at costs competitive with other sources of renewable energy. The technical objectives included developing reservoir models for synthetic geothermal systems that meet target reservoir performance characteristics, performing a quantitative assessment of selection criteria for candidate geothermal sites, perform proppant studies under relevant geothermal conditions, and complete an induced seismicity risk analysis for potential geothermal development sites. The project team made significant progress towards these objectives. Specifically, we developed a prioritization to rank candidate sites for suitability of our technology based on 10 separate technical, operational, logistic, regulatory, and commercial criteria. The team performed laboratory testing at Lawrence Berkeley National Laboratory to characterize the functionality of several different types of proppant materials at temperatures of up to 200 C for durations of up to 9 weeks. We also created an Induced Seismicity Mitigation Plan for the top two sites selected for our future field demonstrations.

58 GEOSCIENCES↗