Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy use intensity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Catalytic Graphitization of Biocarbon for Lithium‐Ion Anodes: A Minireview

Abstract The demand for electrochemical energy storage is increasing rapidly due to a combination of decreasing costs in renewable electricity, governmental policies promoting electrification, and a desire by the public to decrease CO 2 emissions. Lithium‐ion batteries are the leading form of electrochemical energy storage for electric vehicles and the electrical grid. Lithium‐ion cell anodes are mostly made of graphite, which is derived from geographically constrained, non‐renewable resources using energy‐intensive and highly polluting processes. Thus, there is a desire to innovate technologies that utilize abundant, affordable, and renewable carbonaceous materials for the sustainable production of graphite anodes under relatively mild process conditions. This review highlights novel attempts to realize the aforementioned benefits through innovative technologies that convert biocarbon resources, including lignocellulose, into high quality graphite for use in lithium‐ion anodes.

25 ENERGY STORAGE↗

Quantifying Thermal Performance of the Building Envelope - Beyond Common Practice

Performance metrics serve as useful tools and indicators for many applications. For the building industry, various metrics exist; typically, these metrics do not assess the whole building performance. Instead, these represent separate components or heat transfer mechanisms of a building like R-value, U-factor/value, and airtightness. The mechanisms defined under these metrics all contribute significantly to the overall thermal performance of a building but will rarely act independently. There are metrics that account for the overall energy performance of a building, such as Energy Use Intensity (EUI). However, these metrics tend to be highly influenced by how the building is operated and used. There are also metrics which provide assessment on a relative basis. These indices are based upon comparison to a baseline, which complicates meaningful metric-based energy analyses. This paper presents a performance metric developed to account for various thermal properties and behaviors of a building. The metric accounts for all the relevant mechanisms that influence heat losses and gains in buildings and is thus directly related to the energy performance. In addition, the metric is designed to comprise air infiltration and allows users to account for workmanship quality, and imperfections of the building thermal resistance due to penetrations and other installations. This paper will describe how the metric can be applied for various building types and in different climates.

Pallin, Simon B.↗

Evaluating Energy Efficiency Opportunities from Connected and Automated Vehicle Deployments Coupled with Shared Mobility in California

Connected and Automated Vehicles (CAVs) can be considered to be a disruptive transportation technology, with the potential to significantly improve overall transportation system efficiency; however, CAVs may increase induce vehicle miles traveled (VMT) and bring on greater energy consumption. Further, shared mobility is another disruptive transportation event that is reshaping our travel patterns. The primary goal of this project was to extensively collect data from vehicles and associated infrastructure equipped with CAV technologies from both real-world experiments and simulation studies mainly deployed in California, and develop a comprehensive framework for evaluating energy efficiency opportunities from large-scale (e.g., statewide) introduction of CAVs and a wide deployment of shared mobility systems in a variety of scenarios. To quantify the combined impact of CAV and shared mobility on travel behavior, traffic performance, and energy efficiency, a unique mesoscopic simulation-based model was developed for mobility and energy efficiency evaluation considering these disruptive transportation technologies. As a complement to existing studies on nationwide evaluation of CAVs’ energy impacts, this project was focused on data collection efforts and CAV applications under congested traffic environments that are frequently experienced on a massive scale across the major metropolitan areas in California. Extensive real-world data collection supplemented with simulation studies were conducted to cover a variety of CAV and shared mobility scenarios, particularly on scenarios less-explored in the existing research. Another key component of this project was to consider the interaction between different CAV technologies and shared mobility models, and the compound effect on energy efficiency. A comprehensive modeling suite was developed to quantify the impact of new mobility technologies on travel behavior and traffic performance. The developed modeling framework includes an energy intensity module, mode choice module and activity generation module that are integrated into an agent-based BEAM simulation platform to perform impact analysis based on a variety of scenarios. In addition, the RouteE model has been upgraded to incorporate the impact of CAVs on traffic flow, VMT and energy intensity, using micro-simulation data collected from both freeways and urban arterials. A novel fundamental influencing factor (FIF) mode choice model was developed to link CAV and shared mobility components with travel behaviors, and adapted into the BEAM-centered model framework. A statewide energy inventory was constructed under various CAV technology deployment scenarios by incorporating datasets and models for predicting vehicle market share and vehicle usage, which are tightly associated with the penetration of shared mobility systems. Based applying this modeling suite to a calibrated network in Riverside California, it was found that cooperative automated driving in general will improve mobility, but automated vehicles, even when deployed in a shared autonomous fleet, will likely bring an increase of VMT (up to 36%) due to mode shifts and deadheading. Ride-hailing vehicles typically have better energy efficiency and a higher share of electric vehicles, which helps offset the negative impact from VMT increases when estimating the system-level energy consumption. In general, simulation results show a 6% increase in energy consumption for the scenarios with an increasing shift to ride-hailing modes. The statewide analysis based on the National Household Travel Survey (NHTS) sample data is consistent with the findings from the Riverside network and validate the developed clustering-prediction modeling methodology. The outcomes from this project will help close the knowledge gap on recognizing the potential performance and energy impacts of a broad deployment of CAV and shared mobility technologies across a wide range of roadway infrastructure with varying levels of congestion. Results from this project: 1) will support policymakers in steering CAV development and deployment towards an energy favorable direction; 2) reduce uncertainties in estimating energy saving opportunities from new mobility technologies and services; 3) increase the confidence of CAV technology investors both on the infrastructure side (i.e., transportation agencies) and on the vehicle side (i.e., OEMs); and 4) expedite the deployment of energy-efficient CAV and shared mobility applications.

33 ADVANCED PROPULSION SYSTEMS↗

ORNL Campus Sustainability and Decarbonization using Waste Heat Recovery from the Oak Ridge Leadership Computing Facility’s High-Performance Computing Data Center

Heat pumps are a clean and efficient technology that can be powered by renewable electricity to transfer heat using a refrigerant from one place to another by different heat sources, making buildings clean and environmentally friendly. With the support of the ORNL Laboratory Modernization Division, this project explored and evaluated an innovative solution that uses water-water cost-effective midtemperature heat pump (MTHP) technology to leverage the low-grade waste heat from ORNL Frontier and the data center to deliver 85°C hot water, which replaces hot steam generated using natural gas combustion boilers for water heating or space heating in the buildings of ORNL campus. Two scenarios were studied. In the first scenario, which considered the 5600-5700-5800 complex only, Carrier’s commercial 1,000 kW MTHP technology achieves more than 6,640 MWh/year energy savings, an emission reduction of 858 TCO2e/year CO2, and a payback time of 4.85 years. In the second scenario, which considered the 5600-5700-5800 complex and Buildings 5100, 5200, and 5300, the CO2 emission reduction is 1,483 TCO2e/year, the operating cost savings are $0.21 million annually, and the payback time is 3.74 years. Additionally, a comprehensive HP ShowCase Tool was developed for evaluating the optimal solution to improve sustainability and decarbonization of the buildings on the ORNL campus. The tool is an Excel-based tool integrated with VBA (Visual Basic for Applications) coding. The tool includes collected ORNL campus building information and an MTHP library, which comprises collected commercial and ORNL-defined MTHPs. The tool was used to evaluate the sustainability and decarbonization of the ORNL campus. The tool can be widely used or referenced for heat pump solutions and building decarbonization renovation strategies to modernize ORNL facilities and energy use–intensive equipment to enable efficient, sustainable, and resilient operations in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transforming New Multifamily Construction to Zero: Strategies for Implementing Energy Targets and Design Pathways: Preprint

Creating zero energy (ZE) mid- to high-rise multifamily buildings represent significant challenges in the design world. Tenants often take responsibility for some of the utilities and are responsible for consumption of some of the largest end uses: hot water and plug loads. Furthermore, designers can experience risk in creating new sets of details and recommending new strategies to reach aggressive EUI targets. To assist in a more streamlined and successful design approach to ZE multifamily buildings, five major professional societies and experts from the multifamily space created a Zero Energy Advanced Energy Design Guide (AEDG) for multifamily buildings based on data driven results coupled with actual design experiences and case studies. Pathways to achieve ZE design were established including whole building energy use intensity targets coupled with details on how to achieve success in implementing individual efficiency measures. The guidance strives to overcome design barriers and this paper provides an overview of the recommended process to achieve ZE or ZE-ready status, along with details on selecting energy targets, and strategy pathways to achieve the targets.

advanced energy design guide↗

CAD-based Energy & Cost Models Prove Affordable Net Zero Energy Performance for WonderWindows + 24" On-center Framing

Windows are thermally the “weakest link” in the building envelope. Increasing the thermal resistance of windows can make buildings more energy efficient and reduce the cost of electricity needed for conditioning the building. The proper design and placement of framing can also help to reduce the thermal bridging that occurs near the window frame area. This study investigates the energy performance of multi-pane acrylic windows fitting 24" on-center framing. Initial parametric analysis is done for a single zone accessory dwelling unit (ADU). Then, an energy model was developed for three types of wood-framed buildings: townhomes, stacked flats and hotels. A whole building energy simulation is performed for each of these building types in hot-humid Houston, mixed-humid New York, and cold-humid Minneapolis climates. The results show up to a 39% reduction in heating, ventilation, and air-conditioning (HVAC) related electricity consumption for the cold climate compared to the Base case which has window and wall properties based on ASHRAE standard 90.1 2019. In the hot climate, a modest increase in electricity consumption was seen due to an increase in cooling electricity demand. The ADU achieved Net Zero Energy performance in all 3 Climate Zones despite having the highest exterior surface area-to-floor area ratio: the ADU also had the highest PV kW to floor area ratio compared to the other multi-story building types. The townhomes, hotel and stacked flats respectively met 73, 52 and 57 % of electrical use in Houston, 71, 48 and 56 % in New York, and 63, 40 and 53 % in Minneapolis from energy produced by rooftop solar. If 400 W solar panels are used instead of 320 W panel used for energy simulation, it is estimated that in the townhomes, hotel and stacked flats rooftop solar can meet 91, 65 and 71 % of electrical use in Houston; 89, 60 and 70% in New York, and 79, 50 and 66 % in Minneapolis. A preliminary evaluation of cost shows that such superior performance can potentially be achieved at less first cost with this 24"on-center solution than conventional construction. All the building types at the three locations used for simulation had net energy use intensity under 20 kBtu/sf/year with 320 W solar panel and under 17 kBtu/sf/year with 400 W solar panel. Further tailoring of building envelope R-values and window solar heat gain to particular Climate Zone locations for each building type shows promise in reducing the HVAC electricity use that comprises almost half of building energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of low-exergy heating and cooling systems and topology optimization for deep energy savings at the urban district level

District energy systems have the potential to achieve deep energy savings by leveraging the density and diversity of loads in urban districts. However, planning and adoption of district thermal energy systems is hindered by the analytical burden and high infrastructure costs. It is hypothesized that network topology optimization would enable wider adoption of advanced (ambient temperature) district thermal energy systems, resulting in energy savings. In this study, energy modeling is used to compare the energy performance of “conventional” and “advanced” district thermal energy systems at the urban district level, and a partial exhaustive search is used to evaluate a heuristic for the topology optimization problem. For the prototypical district considered, advanced district thermal energy systems mated with low-exergy building heating and cooling systems achieved a source energy use intensity that was 49% lower than that of conventional systems. The minimal spanning tree heuristic was demonstrated to be effective for the network topology optimization problem in the context of a prototypical district, and contributes to mitigating the problem’s computational complexity. The work presented in this paper demonstrates the potential of advanced district thermal energy systems to achieve deep energy savings, and advances to addressing barriers to their adoption through topology optimization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building envelope anomaly characterization and simulation using drone time-lapse thermography

Defects in building envelopes deteriorate over time without being visible to the human eye, while significantly impacting energy performance due to unaccounted heat transfer. Defects can be characterized in the infrared (IR) spectrum. However, IR readings are typically recorded at singular points in time, when in several cases anomalies can only be revealed at specific times of the day, possibly in different seasons of the year. This paper presents a novel workflow for 3D envelope defect characterization and modeling using aerial time-lapse IR data collection using drones. A comprehensive envelope thermal profile is developed for a case study building employing the photogrammetry software Agisoft Photoscan, which generates temporal IR inspections of building skins using multiple thermography orthomosaics. Point-cloud data is then translated into a CAD model and thermal zones for whole Building Energy Modeling (BEM) using Honeybee as a frontend to EnergyPlus to showcase the potential of inclusion of detailed 4D data. Envelope contributions in this case study’s anomalies showed heat losses of 6447.6 kWh, and Energy Use Intensity (EUI) differences of ~2 kWh/m 2 /year from the baseline. Finally, why there is currently little translation of this work in BEM software is discussed, while identifying limitations and future research in the employment of time-lapse thermography using drones for more accurate building envelope inspection and modeling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long-Term Assessment of Commercial Building Energy and Carbon Emissions in the Northwestern Region Under Future Weather Trend

The future climate significantly impacts building performance and increases uncertainties in energy simulations. A rising temperature trend is expected to heighten cooling loads during summer and result in more carbon emissions. Understanding the impact of future climate on building performance is significant for policymakers to make informed decisions. Building retrofit measures can improve building energy efficiency and reduce operational carbon emissions, yet their effects under future climate conditions have not been fully investigated so far. Thus, we proposed an assessment methodology for evaluating long-term energy consumption and operational carbon reduction potential using a building stock dataset. For this study, commercial buildings in the northwestern (NW) region were utilized to assess the impacts of future climate and building retrofit. In addition, we selected Montana with a cold and dry climate as an example to analyze and discuss the carbon emission reduction potential in buildings. The main findings are: (1) Under future climate trends, changes in energy use intensity (EUI) will fluctuate due to variations in heating and cooling degree-days (HDDs and CDDs) and increasing HDDs will lead to increasing EUI. (2) After applying annual building retrofitting, the long-term EUI reduction potential of buildings in the NW region will decrease with the increasing retrofitting degree, and the short-term EUI reduction potential will be impacted by the change of heating and cooling degree days. (3) In Montana, the long-term carbon intensity reduction potential of retrofitted buildings will decrease under future climate trends with the increasing renewable energy penetration.

building energy modeling↗

Impacts of Model Building Energy Codes

The Department of Energy (DOE) Building Energy Codes Program (BECP) periodically evaluates national and state-level impacts associated with energy codes in residential and commercial buildings. Pacific Northwest National Laboratory (PNNL), funded by DOE, conducted an assessment of the prospective impacts of national model building energy codes from 2010 through 2040. A previous PNNL study evaluated the impact of the Building Energy Codes Program. A 2016 study looked more broadly at overall code impacts and this report describes the methodology used for the assessment and presents the impacts in terms of energy savings, consumer cost savings, and reduced emissions at the state level and at aggregated levels. In 2021, DOE conducted an interim and limited update to its 2016 study to evaluate potential building code updates using the 2016 methodology. That interim update includes estimated savings resulting from updates to the model energy codes, including the ANSI/ASHRAE/IES Standard 90.1-2016 (ASHRAE 90.1-2016) and 2019 editions, as well as the 2018 and 2021 International Energy Conservation Code (IECC). In 2023, DOE developed a fully updated report that includes code updates (ASHRAE 90.1-2019 and 2021 IECC), as well as additional enhancements and updates, including updated energy prices, annual floorspace additions, state code adoption dates, and emission factors, among others. This current version is another fully updated report that includes code updates (ASHRAE 90.1-2022 and 2024 IECC), as well as additional enhancements and updates, including updated energy prices, state code adoption dates, emission factors, and renewable energy contribution among others. Energy codes follow a three-phase cycle that starts with the development of a new model code, proceeds with the adoption of the new code by states and local jurisdictions, and finishes when the new code is implemented and builders, architects, and engineers are required to comply with the new provisions. The development of new model code editions creates the potential for increased energy savings. After a new model code is adopted, potential savings are realized in the field when new buildings (or additions and alterations) are constructed to comply with the new code. The contributions of all three phases are crucial to the overall impact of codes and are considered in this assessment. Figure ES.1 schematically describes the analysis framework. Energy savings are expressed in terms of energy use intensity (EUI) in the figure.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Housing-Performance Atlas of Baltimore Row Homes: Archetype-Based Multi-Hazard Baseline of Energy, Heat, Survivability, and Durability

Baltimore’s historic row-home neighborhoods face escalating risks to energy, heat, and durability under intensifying climate stress. This study develops a Housing-Performance Atlas that quantifies multi-hazard performance for eight representative archetypes using DesignBuilder/EnergyPlus Version 7.3.1.003, under Baltimore TMY3 boundary conditions. Performance is evaluated across the following four adaptation domains: energy use intensity, passive survivability during 72 h outage events, roof overheating exposure (>150 °F exceedance hours), and material service life derived from ISO 15686 and synthesized into Lean and Full Deficit Indices for comparative resilience ranking. Results show that EUI ranged from 46.7 to 67.6 kBtu ft −2 ·yr −1 , survivability from 0 to 23 h, and roof temperatures exceeded 150 °F for 150–210 h, shortening roof service life by up to 10 years. Composite Lean and Full Deficit Indices ranged 7.8–92.4, ranking Model 5 (end-unit, flat roof, two-story with basement) as the most resilient configuration and Model 8 (end-unit, pitched roof, three-story above-grade) as the least resilient due to compounded overheating and energy losses. Heat-related domains accounted for nearly 70% of overall resilience deficits, confirming thermal safety and roof reflectivity as retrofit priorities. The Housing-Performance Atlas establishes a reproducible diagnostic framework linking simulation, service life, and resilience metrics to guide cost-effective, climate-responsive retrofits in Baltimore’s aging urban housing stock.

Housing-Performance atlas↗

Development of new baseline models for U.S. medium office buildings based on commercial buildings energy consumption survey data

Building energy estimation for the building sector under various scenarios are needed for building energy regulation and policy making. This often starts with representative baselines (either empirical baseline or modeled baseline). Commercial Buildings Energy Consumption Survey (CBECS) data is a widely used empirical baseline for U.S. commercial buildings, but none of the existing baseline model are developed to represent the CBECS data. This paper aims to develop new baseline models for the U.S. medium office buildings, which can produce modeled baselines consistent with the CBECS data. Here, we introduced the methodology to create baseline models and the criteria to evaluate the performance of baseline models. The methodology consists of three phases: (1) identification of model inputs, (2) model calibration, and (3) model validation with uncertainty analysis. The evaluation index is the coefficient of variation of the root-mean-square deviation (CV(RMSD)) of site energy use intensities (EUIs) between the modeled baseline and empirical baseline. Then 30 new baseline models for two vintages (pre- and post-1980) and 15 climate zones were created. The evaluation shows that the CV(RMSD) is lower than 0.05 for the modeled baselines produced by the new baseline models. As a comparison, the CV(RMSD) is higher than 0.1 for the existing modeled baselines generated by DOE Commercial Reference Building Models. Further analysis shows that the new baseline models are able to capture the uncertainties of the representative features of existing buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lighting and visual comfort performance of commercially available tubular daylight devices

Tubular daylight devices (TDDs) require a much smaller roof opening than conventional skylights and, because of their highly reflective tube, they can deliver daylight farther away from the building envelope. This can provide lighting energy savings, increasing resilience in new and existing buildings. Different types and configurations are available amongst commercially available TDDs, including domes/diffusers with varying optical properties and the diameter of the TDD. This paper presents a comprehensive experimental evaluation of the lighting and visual comfort performance of multiple configurations of commercially available TDDs, varying dome type (prismatic and clear), diffuser type (Fresnel and prismatic), and diameter (53 and 35 cm), under a range of environmental conditions (different times of day/year, sky cover). Based on illuminance measurements, estimated lighting energy use is also presented. Results indicate that, for clear sky, light levels increase and energy use decreases with solar altitude (e.g., 16 Wh/m 2 daily energy use intensity on a high maximum daily solar altitude (MDSA) day and 34 Wh/m 2 on a low MDSA day) and TDD diameter (e.g., 34 Wh/m 2 and 69 Wh/m 2 for 53 cm and 35 cm TDDs, respectively, for low MDSA). The daily illuminance profile is more rounded for prismatic domes and has higher peaks for clear domes; this translates into a somewhat higher average daily useful daylight illuminance (DUDI) for prismatic domes (86 %) when compared to clear domes (80 %). No clear impact of diffuser type was apparent. In conclusion, measurements indicated no discomfort glare for any of the conditions tested.

14 SOLAR ENERGY↗

Pathway for decarbonizing residential building operations in the US and China beyond the mid-century

With global carbon budget targets looming, residential buildings in top economies must become carbon neutral as soon as possible to reserve more emission space for emerging carbon-emitting economies. This study is the first to compare the operational decarbonization process of China’s and the United States (US) residential buildings from 2000 to 2060 by combining the end-use emission model with the decomposing structural decomposition (DSD) method and Monte Carlo simulation. The results show that from 2001 to 2020 China decarbonized 1544 mega-tons of carbon dioxide (MtCO 2 ) and the US decarbonized 1848 MtCO 2 . In the business-as-usual scenario, China will hit its emission peak in 2031 (±3) with 934 (±61) MtCO 2 , while the US will maintain a lock-in level of 736 (±133) MtCO 2 since the 2030s. In the decarbonization scenario, operational carbon neutrality for residential buildings in 2060 is promoted by an increase in clean power generation proportion, building-integrated power generation level, building electrification level, and a reduction in end-use energy intensity, which will contribute 34.4 %, 21.4 %, 14.3 %, and 29.9 % in China and 32.9 %, 33.1 %, 8.2 %, and 25.8 % in the US, respectively. Especially, building-integrated power generation in China only costs about 40 % of what it costs in the US. Besides, high-decarbonization strategies for residential building operations are proposed as references for governments to formulate targeted climate policies. Overall, this study offers data benchmarks for buildings’ carbon neutrality of top economies to further promote synergistic carbon neutrality with the buildings of emerging economies in the age of Post COP27.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Process modeling guides operational variables that affect CO 2 utilization during the accelerated carbonation of concrete

Abstract Accelerated concrete carbonation is an expanding option for decarbonizing construction. Factors such as concrete mixture design and carbonation environment can influence the maximum CO 2 utilization that can be achieved during such a process. A carbonation process designed to utilize a water‐saturated dilute CO 2 source wherein 2 < CO 2 concentration (v/v%) < 16, was modeled in AspenPlus©. A regression model was developed to correlate CO 2 uptake, relative humidity (11%–100%), CO 2 concentration ([CO 2 ] = 2—16 v/v%), and temperature ( T = 11–74°C) conditions within a carbonation reactor. It was determined that [CO 2 ] was the most significant variable as higher concentrations enhanced CO 2 transport through the concrete. The energy use intensity per mass of CO 2 utilized (kWh/kgCO 2 ) was determined across a range of processing conditions. As a function of the operational conditions, accelerated carbonation provides a net CO 2 reduction of up to 28 kgCO 2 /tonne of concrete; a reduction of up to ~45% compared to typical formulations.

Prentice, Dale P.↗

Life-cycle energy use and greenhouse gas emissions of palm fatty acid distillate derived renewable diesel

This study aims to quantify life-cycle fossil energy use and greenhouse gas (GHG) emissions for palm fatty acid distillate (PFAD) derived renewable diesel (RD) taking into consideration different feedstock classifications that are applicable to PFAD (residue, byproduct, or coproduct), and incorporating updated data for key processes. Under the three classifications, the PFAD to RD pathway was modeled using the Greenhouse gases, Regulated Emissions, and Energy Use in Technologies (GREET®) model. PFAD-derived RD could reduce fossil energy consumption by 77%–88%, relative to petroleum diesel. GHG emissions are very sensitive to PFAD classification and coproduct handling methods. Considering the production of palm oil and PFAD and economic value, we maintain that PFAD should be treated as a byproduct in palm oil refineries. With this treatment, PFAD-derived RD could achieve 84% GHG emissions reductions, compared to the emissions of petroleum diesel. We also employed a substitution method to address the substitution of PFAD by other materials in the marketplace. Compared to coproduct allocation results, we found substituting PFAD by tallow, soy oil, barley, and canola oil results in lower GHG emissions. Due to high induced land-use change emissions associated with palm farming, if PFAD is treated as a coproduct with refined palm oil, PFAD-derived RD may not deliver GHG reductions. A sensitivity analysis identified key parameters such as palm fruit yield, oil extraction efficiency in oil mills, and energy use intensity for RD production affects LCA results significantly; future efforts to improve these parameters could result in further GHG reductions.

09 BIOMASS FUELS↗

Systematic approach to define a prototype building model: Convenience Store

The US Department of Energy supports the development of commercial building energy codes and standards. To support commercial building energy research activities, continuous efforts have been made to convert 30 prototype building models, which cover 80% of commercial building floor space in the United States, into OpenStudio Standards prototype buildings. In this paper, we provide a systematic approach to define the building and system characteristics of a convenience store, which has the largest energy use intensity among the commercial building types not covered by current prototype models. This study will be used as a basis for developing the prototype convenience store building model.

Yoon, Yeobeom↗

A Comprehensive System of Energy Intensity Indicators for the U.S.: Methods, Data and Key Trends

This report describes a comprehensive system of energy intensity indicators for the United States that has been developed for the Department of Energy’s Office of Energy Efficiency and Renewable Energy (EERE) over the past decade. This system of indicators is hierarchical in nature, beginning with detailed indexes of energy intensity for various sectors of the economy, which are ultimately aggregated to an overall energy intensity index for the economy as a whole. The aggregation of energy intensity indexes to higher levels in the hierarchy is performed with a version of the Log Mean Divisia index (LMDI) method. Based upon the data and methods in the system of indicators, the economy-wide energy intensity index shows a decline of about 16% in 2014 relative to a 1985 base year. Discussion of energy intensity indicators for each of the broad end-use sectors of the economy—residential, commercial, industrial, and transportation—is presented in the report. An analysis of recent changes in the efficiency of electricity generation in the U.S. is also included. A detailed appendix describes the data sources and methodology behind the energy intensity indicators for each sector.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗