Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The interactive indoor-outdoor building energy modeling for enhancing the predictions of urban microclimates and building energy demands

There is a lack of an urban building energy modeling framework that considers the influence of surrounding buildings and local urban climate on building thermal performance. This can lead to inaccurate results since the thermal performance of individual buildings is heavily influenced by their surrounding built and climatic environment. This study establishes an interactive indoor-outdoor building energy modeling method to enhance the predictions of urban microclimates and building energy demands by coupling an urban physics model with a physics-based building energy model. Validation of the interactive coupling scheme uses field measurement datasets. Parametric simulation and analysis are conducted to understand the influence of the roof-to-canyon width ratio, canyon orientation, and ground vegetation fraction on canyon temperature, building energy consumption, and energy demand. Furthermore, the impacts of building energy model complexity (e.g., detailed vs. simplified building models) and coupling approaches on canyon temperature and building energy profiles are demonstrated using two case study buildings. In comparison with the one-way coupling approach, cooling energy consumption predicted with the dynamic two-way coupling approach varies by 3.5% and 0.5% for the detailed medium office building model and high-rise building model, respectively, and peak cooling demand varies by 8.4% and 7.0% for the detailed medium office building model and high-rise building model, respectively. Here this study also suggests that adopting a complex two-way coupling approach with environmental data exchange at various elevations is necessary for modeling tall buildings at the urban scale.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automated model generation and parameter estimation of building energy models using an ontology-based framework

This study presents a methodology for automated model generation and parameter estimation of building energy models using semantic modeling and Bayesian estimation. Semantic modeling techniques are used to represent the system components and their interactions, facilitating the automatic generation of a simulation model from dynamic component models. The proposed approach is applied to a case study of a ventilation system where a simulation model is generated, calibrated, and assessed through different performance metrics. These metrics demonstrate the accuracy and reliability of both model point estimates and probabilistic prediction intervals across all model outputs. Overall, the proposed methodology offers a systematic and automated approach to model development and calibration in building energy systems, with potential applications in building performance analysis, monitoring, and optimization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Generation of Data-Driven Expected Energy Models for Photovoltaic Systems

Although unique expected energy models can be generated for a given photovoltaic (PV) site, a standardized model is also needed to facilitate performance comparisons across fleets. Current standardized expected energy models for PV work well with sparse data, but they have demonstrated significant over-estimations, which impacts accurate diagnoses of field operations and maintenance issues. This research addresses this issue by using machine learning to develop a data-driven expected energy model that can more accurately generate inferences for energy production of PV systems. Irradiance and system capacity information was used from 172 sites across the United States to train a series of models using Lasso linear regression. The trained models generally perform better than the commonly used expected energy model from international standard (IEC 61724-1), with the two highest performing models ranging in model complexity from a third-order polynomial with 10 parameters (Radj2 = 0.994) to a simpler, second-order polynomial with 4 parameters (Radj2=0.993), the latter of which is subject to further evaluation. Subsequently, the trained models provide a more robust basis for identifying potential energy anomalies for operations and maintenance activities as well as informing planning-related financial assessments. We conclude with directions for future research, such as using splines to improve model continuity and better capture systems with low (≤1000 kW DC) capacity.

14 SOLAR ENERGY↗

A Knowledge-based Framework for Building Energy Model Performance Verification

Building energy modeling (BEM) has been widely used by researchers, regulators, and engineers to quantify building energy performance. Quality assurance (QA) and quality control (QC) of the model's performance are essential parts of such analysis. Currently, QA/QC is done in a manual and ad-hoc manner, which is tedious, error-prone, and time-consuming when QA/QC a large number of models. To solve these challenges, we propose a a dAta-driveN buIlding perforMance verificATion framEwork (ANIMATE), which conducts automated output-based verification of building operations requirements (especially for time-series output-based verification of control requirements). While this framework was developed for verifying energy model performance, it can be extended for other applications such as BEM software testing and performance verification of real buildings in the field.

Chen, Yan↗

Development, calibration, and validation of a novel gray-box energy model for residential split air conditioners

Energy models for vapor compression refrigeration in residential air conditioners have been developed through white-box, gray-box, and black-box methods in decades. However, existing white-box and gray-box models require complicated equations with detailed geometries while black-box models require substantial experimental data. Further, this paper aims to develop and validate a simple gray-box steady-state energy model without the need for detailed geometries, which can accurately predict the cooling capacity and electrical power input based on outdoor and indoor air conditions, and supply airflow rates. First three state variables, including the evaporation and condensation temperatures, and refrigerant mass flowrate, are applied to develop the energy model and are solved by three physical equations, including the energy conservations at the evaporator and condenser, and the refrigerant volume-mass flow correlation of the compressor. Secondly, seven performance property functions related to three state variables and three physical equations are identified and calibrated by simple temperature and power measurements. Finally, field experiments are conducted on a residential air conditioner to calibrate these performance property functions and validate the developed model. The validated results reveal the model can accurately predict the cooling capacity and electrical power input, with the normalized root mean square errors of 2.3% and 0.87% respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Customized open source renewable energy models validated through PHIL lab experiments

Energy models for power systems require ongoing updates to reflect advancements in equipment technology and the increasing complexity of power electronic devices. This study utilizes a Power Hardware-in-the-Loop (PHIL) experimental setup to validate custom photovoltaic (PV) inverter models, aiming to enhance and expedite the development of advanced renewable energy models. The research compares the performance of a physical inverter with generic Renewable Energy Source (RES) models recommended by the Western Electricity Coordinating Council (WECC). As inverter-based renewable energy sources become more prevalent in modern electrical grids, it is crucial that dynamic models accurately represent their real-world behavior. Accurate models improve our understanding of these energy resources and their interactions with the grid. The proposed model enhancements are designed to better reflect real inverter performance, based on insights from PHIL experiments. These models are developed using the open source Modelica language and the OpenIPSL Modelica Library, allowing integration across various simulation tools without re-implementation. The paper concludes with a thorough assessment, comparing the enhanced models with PHIL experiments on a real PV inverter in a controlled laboratory setting. As a result, the study provides the enhanced WECC RES models and validation data as open source resources, facilitating further research and development.

Modelica↗

Model Energy Codes End-Use Opportunity Analysis

Model energy codes (ASHRAE Standard 90.1 and IECC) has significantly impacted programs and policies aimed at improving energy efficiency both in United States and across the globe. Standard 90.1, first published in 1975 (originally referred to as Standard 90) provides minimum energy efficiency guidelines for designing, constructing, operating, and maintaining new construction and renovated buildings. It is updated continuously, with new editions published every 3 years. Pacific Northwest National Laboratory (PNNL) conducts simulated energy and cost savings analysis of model energy codes to determine their expected impact and to track progress toward net-zero goals and efficiency targets. Additionally, the simulation outputs are examined to assess how energy is used across primary systems within prominent U.S. commercial building types to understand how energy is used in each building type at the end-use level and to identify areas for improvements in future code cycles. This end-use opportunity analysis of model energy codes provides ASHRAE technical committees and other interested parties a better understanding of how the Standard affects various building systems and end uses, specifically, those in the Standard that most prominently influence energy efficiency. Additionally, findings provide industry stakeholders guidance in identifying building types and end-uses with the most potential for energy efficiency improvements through energy codes and those that may require beyond code measures to meet energy use reduction targets. This paper summarizes features and functionalities of a webtool created by PNNL to explore and visualize the End-Use opportunity analysis.

ASHRAE 90.1, Energy Codes, Tableau↗

Prototype Courthouse Building Energy Model: Building Characteristics and Energy Simulation Results

To coordinate commercial building energy research activities, the US Department of Energy uses a suite of commercial prototype building models, which includes 16 building types and covers 80% of US commercial floorspace. Efforts are underway to expand this suite by developing prototype models for additional building types, including a courthouse. Informed by building design guides, databases, documented projects, and personal communication with courthouse design experts, a 3-story, 4-courtroom, 69,324 ft 2 building was considered as the prototype courthouse to represent an average-sized courthouse in the United States. This report documents the building and system characteristics of the prototype courthouse model combined with climate-specific and construction vintage–specific requirements for the building envelope and systems from ASHRAE Standard 90.1. The energy simulation results are presented for 4 construction vintages (2004, 2007, 2010, and 2013) and 15 ASHRAE climate zones. To verify the energy simulation results, energy use statistics of existing courthouses from different building database are also presented. Based on the simulated energy use, the site energy use intensity of the prototype courthouse ranged from 45 to 159 kBtu/ft 2 compared with the average energy use intensity of 94.7 kBtu/ft 2 for the courthouse building type in the 2012 Commercial Building Energy Consumption Survey (CBECS) Data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prototype College Building Energy Model: Building Characteristics and Energy Simulation Results

The US Department of Energy supports the development of commercial building energy codes and standards. To support commercial building energy research activities and the development of commercial building energy codes and standards, continuous efforts have been made to convert 16 prototype building models, which cover 80% of US commercial building floor space, to OpenStudio prototype buildings. Additionally, the suite of prototype building models was expanded to include the addition of new building prototype models (e.g., courthouse, college building). Multiple sources, including databases, documented projects, and personal communications, were used to define the prototype college building, and a 4-story with 69,063 ft 2 building was considered as the prototype college building to represent an average-sized college building in the United States. To represent realistic occupancy schedules and increase the granularity of information, actual class reservation schedules were collected and used. This report documents the building and system characteristics of the prototype college building model combined with climate-specific and construction vintage–specific requirements for the building envelope and systems from ASHRAE Standard 90.1. The energy simulation results are presented for 4 construction vintages (2004, 2007, 2010, and 2013) and 15 ASHRAE climate zones. The site energy use intensity of the college building was compared with 2012 Commercial Building Energy Consumption Survey (CBECS) and ENERGY STAR data to verify the simulation results. The site energy use intensity of the college building ranged from 60 to 202.4 kBtu/ft 2 , and compared with the energy use intensities of Commercial Building Energy Consumption Survey (122.9 kBtu/ft 2 ) and ENERGY STAR (84.3 kBtu/ft 2 ) data, the prototype college building results are in a reasonable range.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An open source analysis framework for large-scale building energy modeling

Full integration of building energy modelling into the design and retrofit process has long been a goal of building scientists and practitioners. However, significant barriers still exist. Among them are the lack of available: (1) configurable technology stacks for performing both small- and large-scale analyses, (2) different classes of algorithms compatible with common design workflows, and (3) analysis tools for effectively visualizing large-scale simulation results. This article discusses the OpenStudio® Analysis Framework: a scalable analysis framework for building energy modelling that was developed to overcome the three barriers listed above. The framework is open-source and scalable to facilitate wider adoption and has a clearly defined application programming interface upon which other applications can be built. It runs on high-performance computing systems, within cloud infrastructure, and on laptops, and uses a common workflow to enable different classes of algorithms. Lessons learned from previous development efforts are also discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Model to Evaluate Thermal Energy Storage Integrated with Air Source Heat Pumps: Preprint

Full decarbonization in buildings requires the replacement of combustion appliances with electric ones, and air source heat pumps (ASHP) are a candidate alternative. However, technical limitations, such as the efficiency decrease when operating in cold weather, limit their adoption in the global heating market. Among several options to improve ASHP efficiency operating in colder climates, thermal energy storage (TES) has been considered, as it may provide heating when it is cold and shift ASHP operation to times when the weather is warmer. It may also take advantage of time of use electricity rates and support defrosting when necessary. The evaluation of ASHP-TES systems, however, is still limited because traditional metrics do not capture their full economic and environmental benefits. In this work, a python framework is presented to model the ASHP with and without the presence of TES. Metrics are proposed to analyze the system performance in terms of costs, equivalent CO2 emission, and efficiency metrics to evaluate and compare alternative systems. Model validation against experimental data obtained for a commercial heat pump is provided, as well as an application example using Denver, Colorado, to highlight the model capabilities.

cold climate↗

MCP-enabled agentic AI workflow for building energy modelling: framework and use cases

Traditional building energy modelling workflows remain labor-intensive and error-prone, requiring specialized expertise that limits broader adoption. This paper introduces a novel Model Context Protocol (MCP)-enabled framework that connects AI assistants to EnergyPlus through MCP, a standardized interface for tool invocation and context management. Two complementary integration paradigms are presented and compared: conversational integration, where users interact through natural language while an AI assistant orchestrates MCP tools on demand, and agentic workflow integration, where specialized agents coordinate autonomously to complete multi-step tasks. Using an experimental testbed for residential buildings, the end-to-end workflows are demonstrated. The conversational approach reduced typical inspection and modification tasks from 1-2 h to under 15 min, while maintaining full transparency through visible tool invocations. The agentic approach automated parametric analysis. These demonstrations establish MCP as a foundational layer for AI-assisted building energy modelling, enabling natural language interactions with simulation tools while preserving professional oversight and decision-making authority.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

How close are urban scale building simulations to measured data? Examining bias derived from building metadata in urban building energy modeling

Residential and commercial buildings in the United States accounted for 40% of total energy in 2020. Building energy modeling (BEM) is a useful tool that allows individuals, researchers, companies, or utilities to save energy by optimizing buildings through estimation of building technology savings and performance projection of building energy under various environmental conditions. Urban building energy modeling (UBEM) expands the scope beyond individual buildings to the buildings in a neighborhood, city, utility and more. Yet there is a knowledge gap in the literature as to how these models compare to measured data on an individual and aggregated basis. As UBEM data and methods continue to develop, it is important to consider the accuracy, bias, and limitations of the models. Here, nation-scale data and UBEM software suite named Automatic Building Energy Modeling (AutoBEM) was used to model 50,843 buildings in Chattanooga, Tennessee. The uncalibrated simulation results were compared to aggregated 15-minute electricity data for the year 2019 with visualizations highlighting sources of bias in building data and the AutoBEM framework while considering how they relate to other UBEM methods. Estimation of building type and year of constructions are found to be the major sources of bias. Accounting for the amount of conditioned area per building significantly improves the overall fit of the simulated energy use intensity. it was found that inherent variation in building energy use contributes to R 2 values between 0.008 and 0.095 across building types but slope values near 1 for the total number of buildings. This indicates the need for building aggregation for representative building energy modeling with data sources available at an urban scale while illustrating the need for additional individual building data and model improvement beyond the originally produced UBEM models for individual building analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Net-zero CO 2 by 2050 scenarios for the United States in the Energy Modeling Forum 37 study

The Energy Modeling Forum (EMF) 37 study on deep decarbonization and high electrification analyzed a set of scenarios that achieve economy-wide net-zero carbon dioxide (CO 2 ) emissions in North America by mid-century, exploring the implications of different technology evolutions, policies, and behavioral assumptions affecting energy supply and demand. Here, for this paper, 16 modeling teams reported resulting emissions projections, energy system evolution, and economic activity. This paper provides an overview of the study, documents the scenario design, provides a roadmap for complementary forthcoming papers from this study, and offers an initial summary and comparison of results for net-zero CO 2 by 2050 scenarios in the United States. We compare various outcomes across models and scenarios, such as emissions, energy use, fuel mix evolution, and technology adoption. Despite disparate model structure and sources for input assumptions, there is broad agreement in energy system trends across models towards deep decarbonization of the electricity sector coupled with increased end-use electrification of buildings, transportation, and to a lesser extent industry. All models deploy negative emissions technologies (e.g., direct air capture and bioenergy with carbon capture and storage) in addition to land sinks to achieve net-zero CO 2 emissions. Important differences emerged in the results, showing divergent pathways among end-use sectors with deep electrification and grid decarbonization as necessary but not sufficient conditions to achieve net zero. These differences will be explored in the papers complementing this study to inform efforts to reach net-zero emissions and future research needs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Developing and tuning a community scale energy model for a disadvantaged community

This work describes the development of a community-scale energy model for a mixed-use low-income community located in Huntington Beach, CA. An accurate community-scale energy model is useful for evaluating the use of limited capital resources used to invest in clean energy technologies. This work lays out the process of developing such a model while relying primarily on publicly available data and highlighting critical partnerships necessary for model development success. The primary contribution of this work is the demonstration of the process used to develop an accurate energy model for a disadvantaged community when minimal building and energy use data is available. The heart of the model is the physics-based community scale energy modeling platform URBANopt. Using a bottom-up load modeling approach, energy simulated energy use falls within 3% or less of aggregate annual utility data, and within 10% or less aggregate monthly utility data. The demonstrated model development and tuning process can be used by others to characterize other atypical communities, which may differ significantly from prototypical models.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Empirical Validation of UBEM: An Assessment of Bias in Urban Building Energy Modeling for Chicago

Residential and commercial buildings currently account for 30% of total global final energy consumption. Urban-scale building energy modeling (UBEM) can enable scalable investments and unlock building improvements by quantifying energy, demand, emissions, and cost reductions of specific measures or packages for building-specific technologies in large geographic regions. While the sophistication of UBEM data sources and technologies have increased dramatically in the past decade, there remains a knowledge gap for empirical validation and sources of bias between building-specific energy models and measured data at varying geographic scales.As UBEM continues to develop, systemic analysis of accuracy, bias, and limitations of the resulting models is necessary to inform best practices and move toward standardization. These are characterized for the Automatic Building Energy Modeling (AutoBEM) software suite with an initial case study involving metered electricity consumption data from 247,188 buildings in Chicago, Illinois, USA - averaged across years 2019-2021 - compared to the following datasets: (1) the AutoBEM-generated nation-scale Model America version 2 (MAv2) data for 596,064 buildings, (2) tax assessor data for 579,829 buildings, (3) tax assessor data filled with MAv2, and (4) 102 representative dynamic archetypes. The accuracy is reported for every building type and vintage combination, along with multiple sources of bias for unique building descriptors. The AutoBEM simulation workflow produced energy consumption estimates that closely match aggregated metered electricity consumption data for different types of buildings constructed during various time periods at the city scale - with initial normalized mean bias error of 10.9%, and 1.1% after removing outliers. Contribution of statistically significant factors including building type, land use, age, and size to variance in UBEM bias is quantified.

Garg, Ankur↗

Bioenergy pathways within United States net-zero CO 2 emissions scenarios in the Energy Modeling Forum 37 study

The Energy Modeling Forum 37 study is organized around carbon dioxide (CO 2 ) mitigation scenarios reaching net-zero CO 2 emissions by 2050 in the United States. Here, this paper summarizes the potential contribution of bioenergy use in the electric power, transportation, industrial, and buildings sectors toward meeting that target based on model results. Thirteen modeling teams reported bioenergy consumption in the Reference and Net Zero scenarios. Consumption of bioenergy increased over time in the Reference scenario, from an average across models of 3.2 exajoules (EJ) in 2020 to 3.8 EJ in 2050. Average bioenergy consumption in 2050 increased further to 7.3 EJ in the Net Zero scenario. All scenarios that reach net-zero emissions required some form of carbon dioxide removal to offset emissions that are difficult to reduce. Carbon dioxide removal using bioenergy with CO 2 capture and storage (BECCS) varies widely across models, up to 1000 Mt CO 2 in 2050. Some models rely instead on direct air carbon capture and storage (DACCS), up to 2200 Mt CO 2 , and others use a combination of BECCS and DACCS. Model results show a strong inverse relationship between the amounts of BECCS and DACCS deployed. All modeling teams assumed a carbon sink from land use, land use change, and forestry, further offsetting a portion of emissions from fossil fuels and industry that are expensive to eliminate. Bioenergy consumption in 2050 decreased by an average of 1.5 EJ across eight models in a Net Zero+ scenario relative to the Net Zero scenario, due in part to a lower equilibrium carbon price resulting from optimistic cost assumptions for all energy technologies.

09 BIOMASS FUELS↗

Calibration of urban building energy model using smart meter data for district peak load prediction

Urban building energy modeling (UBEM) is a powerful approach to assessing baseline building energy performance and retrofits with new technologies across building stocks in cities. However, the accuracy of UBEM is often constrained by the limited availability of reliable data about building characteristics and operations, such as envelope efficiency levels, HVAC system performance, and end-use load patterns. Existing research has performed UBEM calibration using annual or monthly energy consumption data, which falls short when higher-resolution time series applications are needed, such as peak load prediction for utility operation planning. This study presents a new framework for calibrating building energy models at urban scale using smart meter data, targeting the accurate prediction of summer peak electricity loads to support robust grid planning. The framework first integrates various data sources to enhance baseline input assumptions for building models, and then calibrates the baseline models through a pattern-matching approach. A case study using CityBES and two years of AMI data from over 9000 residential customers in Portland, Oregon, demonstrated the workflow and its effectiveness. The calibrated models achieved a daily peak load mean absolute percentage error of 2.6 % during the heatwave in the calibration year, and 2.0 % in the validation year using another year of AMI data. Using the calibrated models, we analyzed the demand flexibility potential of the district building stock as an application of UBEM calibration. The findings affirm the appropriate use of UBEM for peak electric load forecasting and demand side management at the utility distribution system level.

AMI data↗