Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy intensity usage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Digital Modeling on Large Kernel Metamaterial Neural Network

Deep neural networks (DNNs) utilized recently are physically deployed with computational units (e.g., CPUs and GPUs). Such a design might lead to a heavy computational burden, significant latency, and intensive power consumption, which are critical limitations in applications such as Internet of Things (IoT), edge computing, and usage of drones. Recent advances in optical computational units (e.g., metamaterial) have shed light on energy-free and light-speed neural networks. However, the digital design of the metamaterial neural network (MNN) is fundamentally limited by its physical limitations, such as precision, noise, and bandwidth during fabrication. Moreover, the unique advantages of MNN’s (e.g., light-speed computation) are not fully explored via standard 3×3 convolution kernels. In this paper, we propose a novel large kernel metamaterial neural network (LMNN) that maximizes the digital capacity of the state-of-the-art (SOTA) MNN with model re-parametrization and network compression, while also considering the optical limitation explicitly. The new digital learning scheme can maximize the learning capacity of MNN while modeling the physical restrictions of meta-optics. With the proposed LMNN, the computation cost of the convolutional front-end can be offloaded to fabricated optical hardware. The experimental results on two publicly available datasets demonstrate that the optimized hybrid design improved classification accuracy while reducing computational latency. In conclusion, the development of the proposed LMNN is a promising step towards the ultimate goal of energy-free and light-speed AI.

97 MATHEMATICS AND COMPUTING↗

Designing Energy-Efficient Quantum Computers Through Prediction and Reduction of Cooling Requirements for Cryogenic Electronics

Quantum computing has been identified as a “wild card” by the International Energy Agency in predicting future global data center energy usage. This is primarily because both uncertainty in the extent to which quantum computing will be adopted, and uncertainty in the power consumption of individual quantum data centers. Unlike the classical counterparts, quantum computers need to be maintained at near absolute zero, requiring energy-intensive cryogenic cooling systems. Therefore, as quantum computers scale up from existing 50 qubit technology demonstrations to the 10,000 to 100,000 qubit systems that will be able to solve complex problems, the energy consumption of both the electronics and the required cooling systems will also increase. To predict this scaling, this work analyzes the energy requirements for both computation and cooling of quantum hardware. We show that the energy requirements for cooling of quantum computers is determined by several computing system parameters, including the number and type of physical qubits, the operating temperature, the packaging efficiency of the system, and the split between circuits operating at cryogenic temperatures and those operating at room temperature. The energy requirements can then be found based on thermal system parameters such as cooling efficiency and cryostat heat transfer. Analysis of these parameters shows that the energy required for cooling is significantly larger than that required for computation, a reversal from energy usage patterns seen in conventional computing. The results and discussions provide a road-map for creating energy efficient quantum computers through the selection of computer architectures and cryogenic system configurations that minimize cooling requirements.

energy efficiency↗

Impact of installation faults in air conditioners and heat pumps in single-family homes on U.S. energy usage

To ensure that new residential air conditioners and heat pumps operate optimally, care must be taken during the initial system design and installation to avoid missteps that immediately degrade a system’s performance. Laboratory and simulation studies have quantified the impact that faults can have on capacity and efficiency. Field studies have demonstrated that installation-related faults are commonplace. However, the national impact of installation-related faults cannot be accurately estimated by only simulating a limited number of homes at several fault levels because of the variety of home characteristics and climates involved. In our analysis, we use an improved residential building stock simulation tool to predict the annual energy increase and additional utility costs resulting from two common installation faults: indoor airflow rate and refrigerant charge level. Our method considers the wide range of building characteristics and climate zones of the U.S. housing stock. We use existing field data to develop fault intensity probability distributions to inform our analysis. The study shows that these two faults result in approximately 20.7 TWh/y of additional energy use for central air conditioners and air-source heat pumps in U.S. single-family detached homes, which is a 9% increase over baseline (no-fault) usage, costing homeowners approximately $2.5 billion annually on utility bills. Air-source heat pumps are responsible for a disproportionate fraction of this energy use increase because of the larger number of operating hours compared to central air conditioners and the sensitivity of heating mode performance to the faults analyzed compared to cooling mode.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Intelligent Distributed Ledger Construction Algorithm for IoT

Blockchain is the next generation of secure data management that creates near-immutable decentralized storage. Secure cryptography created a niche for blockchain to provide alternatives to well-known security compromises. However, design bottlenecks with traditional blockchain data structures scale poorly with increased network usage and are extremely computation-intensive. This made the technology difficult to combine with limited devices, like those in Internet of Things networks. In protocols like IOTA, replacement of blockchain's linked-list queue processing with a lightweight dynamic ledger showed remarkable throughput performance increase. However, current stochastic algorithms for ledger construction suffer distinct trade-offs between efficiency and security. This work proposed a machine-learning approach with a multi-arm bandit that resolved these issues and was designed for auditing on limited devices. This algorithm was tested in a reinforcement-learning environment simulating the IOTA ledger's construction with a decision tree. This study showed through regret analysis and experimentation that this approach was secure against impulse manipulation attacks while remaining energy-efficient. Although the IOTA protocol was a pioneer for lightweight distributed ledgers, it is expected that future blockchain protocols will adopt techniques similar to those presented in this work.

multi-arm bandit↗

Technoeconomic Analysis of Microwave-Assisted Dry Reforming Integrated with Chemical Looping for Production of Methanol

Methanol is a key component in producing formaldehyde, acetic acid, and methyl tert -butyl ether (MTBE) and supports a wide array of industries, including plastics, textiles, and automotive. It also plays a growing role in renewable energy solutions. However, the conventional production of methanol involves steam reforming of methane, which is very energy-intensive and produces significant quantities of the greenhouse gas carbon dioxide. In this research, a chemical looping scheme is combined with dry reforming of natural gas in a novel microwave reactor to produce an industrial quantity of methanol. A heat exchanger network is developed to substantially reduce hot and cold utility usage. The effect of the cost of purchasing carbon dioxide from an external source for dry reforming, the capital cost of the microwave reactor, and the cost of electricity on the net present value is analyzed. Technoeconomic comparison with the conventional industrial process that produces methanol via steam reforming of methane indicates that the chemical looping generates a significant positive net present value along with a substantial reduction in carbon dioxide emissions while producing methanol significantly below the U.S. Department of Energy’s goal of $800/ton.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spatially and Temporally Detailed Water and Carbon Footprints of U.S. Electricity Generation and Use

Electricity generation in the United States entails significant water usage and greenhouse gas emissions. However, accurately estimating these impacts is complex due to the intricate nature of the electric grid and the dynamic electricity mix. Existing methods to estimate the environmental consequences of electricity use often generalize across large regions, neglecting spatial and temporal variations in water usage and emissions. Consequently, electric grid dynamics, such as temporal fluctuations in renewable energy resources, are often overlooked in efforts to mitigate environmental impacts. The U.S. Department of Energy (DOE) has initiated the development of resilient energyshed management systems, requiring detailed information on the local electricity mix and its environmental impacts. This study supports DOE's goal by incorporating geographic and temporal variations in the electricity mix of the local electric grid to better understand the environmental impacts of electricity end users. We offer hourly estimates of the U.S. electricity mix, detailing fuel types, water withdrawal intensity, and water consumption intensity for each grid balancing authority through our publicly accessible tool, the Water Integrated Mapping of Power and Carbon Tracker (Water IMPACT). While our primary focus is on evaluating water intensity factors, our dataset and programming scripts for historical and real-time analysis also include evaluations of carbon dioxide (equivalence) intensity within the same modeling framework. This integrated approach offers a comprehensive understanding of the environmental footprint associated with electricity generation and use, enabling informed decision-making to effectively reduce Scope 2 water usage and emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Conventional and Next Generation Treatment Technologies for PFAS - 20067

In 2016, the United States Environmental Protection Agency (USEPA) established a Health Advisory Limit (HAL) for perfluorooctanoic acid (PFOA) and perfluorooctane sulfonic acid (PFOS) (individually and the summation) of 70 nanograms per liter (ng/L) based on developing toxicological information. These two compounds are among several thousand per- and polyfluoroalkyl substances (PFAS). Due to a multitude of commercially beneficial physical and chemical properties, the availability of PFAS-relevant and practical water treatment technologies is limited. The use of conventional adsorbents, such as activated carbon (AC) and anion exchange (AIX) resins, have become a 'de facto' interim measure to immediately address drinking water above this criterion. However, these adsorbents can have marginal long-term efficiency and are relatively unproven against the diversity of polyfluorinated compounds. Additionally, geochemical and/or co-contaminant competition can significantly impede adsorption based PFAS removal. These challenges may be addressed using engineered filtration, such as reverse osmosis or nanofiltration (RO/NF); however, for larger flow systems RO/NF may have unacceptable reject ratios as high as 35% and the capital cost may preclude these technologies. Extending these technologies to natural waters, which have various degrees of geochemical and co-contaminant competition, often requires a treatment train, combining conventional adsorbents or engineered filtration with pretreatment and more innovative and emerging remediation solutions for PFAS. Conventional and Next Generation water treatment technologies for PFAS generally employ one of three mechanisms (adsorption, separation, or destruction). These mechanisms include many types of technologies for both municipal drinking water and extracted natural water applications. The previously mentioned AC, AIX, and RO/NF are commercially available technologies that are actively being deployed for PFAS treatment. Research and development around these technologies is focused on optimization, and ultimate destruction of PFAS is achieved through incineration. Next Generation water treatment technologies include PFAS-specific flocculants, foam fractionation, novel AIX resins, new engineered adsorptive media, electrochemical treatment, sonolysis, and photolysis, radiation, and plasma (forms of advanced reductive processes [ARP]). Research and development around these technologies is focused on proof of concept and assimilation to real world applications. As the PFAS-relevant destructive technologies (such as incineration, electrochemical treatment, sonolysis, and ARP) are energy intensive, the state of the practice for PFAS water treatment is to focus adsorption/separation based technologies on reducing and concentrating the volume of water requiring destructive treatment. This enables more flexibility with respect to circulation frequency, residence time, and more control over energy usage. Water treatment for PFAS presently requires multiple technologies (i.e. a treatment train) to protect human health in a cost-conscious manner. An investment in research and development to explore new technologies is part of a key initiative for efficient protection of human health. This presentation attempts to review PFAS-relevant water treatment technologies and provide perspective as to their status with respect to applicability and commercial relevance. (authors)

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Advanced electrode processing for lithium-ion battery manufacturing

Lithium-ion batteries (LIBs) need to be manufactured at speed and scale for their use in electric vehicles and devices. However, LIB electrode manufacturing via conventional wet slurry processing is energy-intensive and costly, challenging the goal to achieve sustainable, affordable and facile manufacturing of high-performance LIBs. Here, in this Review, we discuss advanced electrode processing routes (dry processing, radiation curing processing, advanced wet processing and 3D-printing processing) that could reduce energy usage and material waste. Maxwell-type dry processing is a scalable alternative to conventional processing and has relatively low manufacturing cost and energy consumption. Radiation curing processing could enable high-throughput manufacturing, but binder selection is limited to certain radiation curable chemistries. 3D-printing processing can produce electrodes with diverse architectures and improved rate performance, but scalability is yet to be demonstrated. 3D-printing processing is good for special applications where throughput and cost can be compromised for performance.

25 ENERGY STORAGE↗

Silicon x-ray backlighter improvement by targets with spike-like microstructures

In order to accurately probe high energy density matter states, it is vital to create powerful x-ray backlighters. One approach to create such x-ray sources is based on the usage of short-pulse, high-energy lasers, which greatly benefits from an optimization of the laser target coupling. Here, the spectral and temporal x-ray emission profiles of structured silicon targets with micron-sized spikes on the front surface are studied at laser intensities of 10 17 W cm -2 . The laser pulse length is varied between 1 and 20 ps with an energy of up to 1 kJ. The structured targets show an up to 13× enhancement of silicon He α emission compared to flat foils with a well-defined, sharp emission pulse profile. Furthermore, the performance of the microstructured targets is compared to targets with a CH shield as well as foils irradiated with a UV prepulse.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enabling Technology - Reducing Greenhouse Gas Emissions and Energy Demands in the Meat Production Industry via Scaling Advanced 3D Culture Bioreactors

The project “Enabling Technology - Reducing Greenhouse Gas Emissions and Energy Demands in the Meat Production Industry via Scaling Advanced 3D Culture Bioreactors” focuses on developing transformational and disruptive food technologies, specifically in the area of alternative protein and meat production techniques. The impetus for developing alternative protein technologies include reducing intensive greenhouse gas emissions and energy/land/water usages associated with conventional meat production (animal agriculture). Additional rationales include providing alternatives to livestock rearing as a means of reducing antimicrobial resistance (most antibiotic and antimicrobial use occurs in food-producing animals), as well as the transmission of zoonotic diseases. The goal of this ARPA-E project was to research and develop novel and effective technologies to produce cell-cultured meat (also named in vitro meat, cultivated meat). Cell-cultured meat is an alternative protein or meat technology that involves directly growing muscle and fat tissues (which comprise meat) without using the full animal. This offers benefits in terms of animal welfare (elimination of animal slaughter), while also being projected to be more resource efficient in terms of metrics such as land use and greenhouse gas emissions, especially when compared to beef and lamb. Cell cultured meat additionally offers greater control over the cultivated cells, enabling more precise control over nutrition and taste. For example, cultured cells could be tuned to produce antioxidants such as carotenoids to improve human health. However, to date there are no scalable methods of producing cell-cultured meat cheaply at a large scale.

59 BASIC BIOLOGICAL SCIENCES↗

A particle-in-cell code comparison for ion acceleration: EPOCH, LSP, and WarpX

There are now more Particle-in-Cell (PIC) codes than ever before that researchers use to simulate intense laser-plasma interactions. To date, there have been relatively few direct comparisons of these codes in the literature, especially for relativistic intensity lasers interacting with thin overdense targets. To address this we perform a code comparison of three PIC codes: EPOCH, LSP, and WarpX for the problem of laser-driven ion acceleration in a 2D(3v) geometry for a 10 20 W cm -2 intensity laser. We examine the plasma density, ion energy spectra, and laser-plasma coupling of the three codes and find strong agreement. We also run the same simulation 20 times with different random seeds to explore statistical fluctuations of the outputs. We then compare the execution times and memory usage of the codes (without “tuning” to improve performance) using between 1 and 48 processors on one node. We provide input files to encourage larger and more frequent code comparisons in this field.

36 MATERIALS SCIENCE↗

Lighting Condition Analysis for Mars' Moon Phobos

This study used high fidelity computer simulation to investigate the lighting conditions, specifically the solar radiation flux over the surface, on Phobos. Ephemeris data from the Jet Propulsion Laboratory (JPL) DE405 model was used to model the state of the Sun, Earth, Moon, and Mars. An occultation model was developed to simulate Phobos' self-shadowing and its solar eclipses by Mars. The propagated Phobos state was compared with data from JPL's Horizon system to ensure the accuracy of the result. Results for Phobos lighting conditions over one Martian year are presented, which include the duration of solar eclipses, average solar radiation intensity, surface exposure time, and radiant exposure for both sun tracking and fixed solar arrays. The results show that: Phobos' solar eclipse time varies throughout the Martian year, with longer eclipse durations during the Martian northern spring and fall seasons and no eclipses during the Martian northern summer and winter seasons; solar radiation intensity is close to minimum in late spring and close to maximum in late fall; exposure time per orbit is relatively constant over the surface during the spring and fall but varies with latitude during the summer and winter; and Sun tracking solar arrays generate more energy than a fixed solar array. A usage example of the result is also present in this paper to demonstrate the utility.

Li, Zu Qun↗

Electrifying High-Efficiency Future Communities: Impact on Energy, Emissions, and Grid

To combat climate change and meet decarbonization goals, the building sector is improving energy efficiency and electrifying end uses to reduce carbon emissions from fossil fuels. All-electric buildings are becoming a trend among new constructions, introducing opportunities for decarbonization but also technical challenges and research gaps. For instance, further investigation is needed to understand how the adoption of energy efficiency measures (EEMs) and distributed energy resources (DERs) in all-electric communities would affect energy consumption, carbon emissions, and grid planning. This paper presents a case study of a mixed-use, all-electric community located in Denver, Colorado. We use URBANopt TM , a physics-based urban energy modeling platform to model the community and then evaluate the impact of EEMs and DERs (i.e., photovoltaics [PV], electric vehicles [EVs], and batteries) on the community's energy usage, carbon emissions, and peak demand. The results show that adding EEMs and PV led to both energy consumption and carbon emissions reductions across all building types. However, we saw fairly limited impact of EEMs and PV on buildings' peak demand in our case. Additionally, due to overnight EV charging activities and higher grid carbon intensity at night, the carbon emissions in multifamily buildings have a noticeable increase compared to scenarios without vehicles. Finally, the addition of batteries helped reduce peak demand by 11%-29%. The modeling workflow and evaluation methods can be applied to similar communities to evaluate their performance and the effect of integrating EEMs and DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Lighting Condition Analysis for Mars' Moon Phobos

This study used high fidelity computer simulation to investigate the lighting conditions, specifically the solar radiation flux over the surface, on Phobos. Ephemeris data from the Jet Propulsion Laboratory (JPL) DE405 model was used to model the state of the Sun, Earth, Moon, and Mars. An occultation model was developed to simulate Phobos' self-shadowing and its solar eclipses by Mars. The propagated Phobos state was compared with data from JPL's Horizon system to ensure the accuracy of the result. Results for Phobos lighting conditions over one Martian year are presented, which include the duration of solar eclipses, average solar radiation intensity, surface exposure time, available energy per unit area for sun tracking arrays, and available energy per unit area for fixed arrays (constrained by incident angle). The results show that: Phobos' solar eclipse time varies throughout the Martian year, with longer eclipse durations during the Martian spring and fall seasons and no eclipses during the Martian summer and winter seasons; solar radiation intensity is close to minimum at the summer solstice and close to maximum at the winter solstice; exposure time per orbit is relatively constant over the surface during the spring and fall but varies with latitude during the summer and winter; and Sun tracking solar arrays generate more energy than a fixed solar array. A usage example of the result is also present in this paper to demonstrate the utility.

Li, Zu Qun↗

FPGA-based HPC accelerators: An evaluation on performance and energy efficiency

Hardware specialization is a promising direction for the future of digital computing. Reconfigurable technologies enable hardware specialization with modest non-recurring engineering cost, but their performance and energy efficiency compared to state-of-the-art processor architectures remain an open question. In this article, we use FPGAs to evaluate the benefits of building specialized hardware for numerical kernels found in scientific applications. In order to properly evaluate performance, we not only compare Intel Arria 10 and Xilinx U280 performance against Intel Xeon, Intel Xeon Phi, and NVIDIA V100 GPUs, but we also extend the Empirical Roofline Toolkit (ERT) to FPGAs in order to assess our results in terms of the Roofline model. We show design optimization and tuning techniques for peak FPGA performance at reasonable hardware usage and power consumption. As FPGA peak performance is known to be far less than that of a GPU, we also benchmark the energy efficiency of each platform for the scientific kernels comparing against microbenchmark and technological limits. Results show that while FPGAs struggle to compete in absolute terms with GPUs on memory- and compute-intensive kernels, they require far less power and can deliver nearly the same energy efficiency.

97 MATHEMATICS AND COMPUTING↗

Connected Loads – Grid Connected Appliances: Commercial Refrigeration System Fault Detection and Diagnostics

As one of the most energy-intensive end-uses in the commercial buildings sector, supermarkets consume around 50 kWh/ft 2 (or 537.6 kWh/m 2 ) of electricity annually, or more than 2 million kWh of electricity per year for a typical store. The biggest consumer of energy in a supermarket is its refrigeration system, which accounts for 40–60% of its total electricity usage and is equivalent to about 2–3% of the total energy consumed by commercial buildings in United States, or around 0.5 quadrillion Btu (or 0.53 quadrillion KJ). Also, the supermarket refrigeration system is one of the biggest consumers of refrigerants. Current supermarket refrigeration systems rely on high global warming potential hydrofluorocarbon refrigerants. Reducing refrigerant usage or using environment friendly alternatives can result in significant climate benefits. Transcritical CO2 refrigeration systems have attracted more attention in recent years because of their zero-carbon emission advantages compared with traditional refrigerants. These systems are widely used in commercial buildings such as supermarkets. The refrigeration system can also be adapted to handle flexible building loads and be integrated into grid response transactive control to balance the supply and demand of the electric grid. Even minor improvements in the efficiency and operational reliability of supermarket refrigeration systems can create significant value in terms of saving energy, improving food quality, protecting the environment, reducing carbon footprint, and enhancing electric grid resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Connected Loads – Grid Connected Appliances: Deployment IoT Solution for Fault Detection and Diagnostics

As one of the most energy-intensive end-uses in the commercial buildings sector, supermarkets consume around 50 kWh/ft 2 ( or 537.6 kWh/m 2 ) of electricity annually, or more than 2 million kWh of electricity per year for a typical store. The biggest consumer of energy in a supermarket is its refrigeration system, which accounts for 40–60% of its total electricity usage and is equivalent to about 2–3% of the total energy consumed by commercial buildings in United States, or around 0.5 quadrillion Btu (or 0.53 quadrillion KJ). Also, the supermarket refrigeration system is one of the biggest consumers of refrigerants. Current supermarket refrigeration systems rely on high global warming potential hydrofluorocarbon refrigerants. Reducing refrigerant usage or using environment friendly alternatives can result in significant climate benefits. Transcritical CO2 refrigeration systems have attracted more attention in recent years because of their zero-carbon emission advantages compared with traditional refrigerants. These systems are widely used in commercial buildings such as supermarkets. The refrigeration system can also be adapted to handle flexible building loads and be integrated into grid response transactive control to balance the supply and demand of the electric grid. Even minor improvements in the efficiency and operational reliability of supermarket refrigeration systems can create significant value in terms of saving energy, improving food quality, protecting the environment, reducing carbon footprint, and enhancing electric grid resilience. For decarbonization, the new administration has set a target to reduce greenhouse gas emissions by 50– 52% by 2030 and targeting a carbon-neutral economy by 2050. For electrification, the goal is to achieve 100% clean electricity by 2035. Such decarbonization and electrification in the building sector require that energy consumption in buildings be reduced significantly. Therefore, the building sector must continuously adopt new technologies to achieve its energy and carbon emission goals. One of the most fundamental technologies is the Internet of Things (IoT). IoT has proven to be an effective solution for the building domain, including building information/energy modeling, smart buildings, etc. Although much progress has been made in the development of IoT-based building energy systems, there is still a lack of reliable, scalable, and affordable IoT-based automated fault and degradation diagnostics (AFDDs) solutions. Such solutions would enable deployment of advanced algorithms into real systems to archive the projected energy benefits. This study reviews existing IoT solutions developed for building energy– related application and developed a simple but effective AFDD IoT deployment solution, including developing a suitable IoT architecture and conducting easy and scalable deployment by leveraging a common cloud-based IoT service.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗