Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy conservation code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Heating and Cooling Energy Modeling of 3D-Printed Concrete Construction of Residential Buildings [Slides]

3D printed concrete construction (C3DP) is an emerging technology that comes with the associated benefits of high thermal mass walls. We investigated using BEopt software the heating and cooling energy use of a single story C3DP-constructed house. We then compared the heating/cooling energy use of the C3DP house against the corresponding energy use in a traditional timber (wood) frame construction (WFC), as well as a concrete masonry unit (CMU) construction. Both peak energy use for heating and cooling (Btu), as well as base energy use for both heating and cooling (MMBtu/yr) of the C3DP design were compared against the WFC and CMU baseline construction of identical geometries and orientations across all eight climate zones defined in the International Energy Conservation Code (IECC). The BEopt models for all three constructions (C3DP, WFC, and CMU) were built to comply with the 2018 IECC code. Results indicate that C3DP construction has significant heating and cooling energy benefits in certain climate zones, with the highest peak cooling energy savings (9% compared to WFC, and 5% compared to CMU) in the IECC Climate Zone 1 in the month of July. The peak heating and cooling energy demand reduction of C3DP were found to be more significant than the base heating and cooling energy demand in all IECC climate zones. The 2018 IECC compliance-related U-Factor adjustments of all models also resulted in more peak energy savings of the C3DP design in the cooling-dominated climate zones (climate zones 1 and 2), moderate energy savings in moderate climate zones (climate zones 3, 4, and 6), and little to no change in energy savings in very cold climates (climate zones 7 and 8).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Approach to High-Performance Affordable Housing Using Point-Source Space Conditioning

In cooperation with the Building America Program, The Levy Partnership explored a variety of options to reduce space-conditioning energy consumption, working with partners to design, manu- facture, and build test homes in three states. The Levy Partnership tested the use of minisplit ductless heat pumps in combi- nation with small through-wall transfer fans to provide space conditioning in small single-story homes, including manufactured homes and homes built by Habitat for Humanity. The team set out to achieve 50% less energy consumption, compared to the 2009 International Energy Conservation Code, while maintaining home afford- ability and thermal comfort. The strategy also included a highly efficient thermal envelope to reduce space-conditioning loads.

30 DIRECT ENERGY CONVERSION↗

Benefits Of Automated Construction And Energy Efficiency Measures In Modular Homes

This article builds on and adds to a Buildings XV publication that introduced the Transformative Efficiency and Automation in Modular Homes (TEAMH) project. The TEAMH project sought to develop a scalable solution for producing modular homes with 20-50% energy savings and similar cost relative to site-fabricated single-family home construction. A key aspect of the project was assessing the potential for labor cost reductions through automation-assisted construction using light gauge steel (LGS). To quantify the advantages of this approach, side-by-side comparisons were made between traditional wood-framed construction and automation-assisted LGS construction. This demonstration involved constructing one wood-framed wall and several LGS test walls, accompanied by a time-and-motion study. The results indicated that automation assistance could decrease construction time and associated labor costs by as much as 46%. High-performance envelope technologies for exterior insulation and air sealing were evaluated to compare modular homes with site-built homes that meet the International Energy Conservation Code (IECC). A key technology considered was vacuum insulation panels (VIPs) with fiberglass cores. Guarded hot box testing of multiple full-scale wall assemblies containing different combinations of exterior continuous insulation systems containing phenolic foam and VIPs. Testing on various full-scale wall assemblies revealed that, with LGS construction, cavity insulation had minimal impact on exterior wall performance. Omitting cavity insulation can reduce labor and material costs while streamlining manufacturing, as its installation is labor-intensive and not easily automated due to the need for precise placement around wiring and other internal components. Guarded hot box tests of multiple LGS test walls with foam and VIP-based exterior insulation systems achieved R-values of up to 31 hr-ft2-°F/Btu. Finally, building energy modeling of multiple modular home designs indicated that the upgraded envelope assemblies can yield heating energy savings of up to 50% and cooling energy savings of up to 30% compared to IECC 2018 standards.

Shrestha, Som [ORNL] (ORCID:0000000183993797)↗

Modeled Results of Four Residential Energy Efficiency Measure Packages for Deriving Advanced Building Construction Research Targets

The Advanced Building Construction (ABC) Initiative from the U.S. Department of Energy Building Technologies Office is working to accelerate industrialized construction innovations for decarbonizing buildings. To inform performance and cost targets for research under the ABC Initiative, this analysis used the ResStock™ tool to evaluate the energy savings, utility bill impacts, and carbon emissions impacts of four simulated upgrade packages with specific target performance levels on a large sample of residential dwelling units (approximately 550,000) representative of the U.S. housing stock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Developing a Composite Vacuum Insulated Panel (VIP) Insulation/Vinyl Siding Composite Technology for Retrofitting Residential Walls

This paper reports on a project that has attempted to seize on an opportunity to take a giant leap forward in commercializing a technology that would address a key opportunity to achieve energy savings in the existing residential housing stock. It is typically very difficult to increase the R-value of the walls in existing residential housing as doing so from the inside is disruptive and there have not been good solutions to increase thermal envelope performance from the exterior through adding continuous insulation due to the additional work required to fit existing architectural features to the new wall thickness and to reclad the façade. A high thermal resistivity or R-value per inch product that can be used in these applications offers an excellent solution.This paper summarizes a three-year research project to a produce vacuum insulated panel (VIP)/vinyl siding that would have sufficient R-value to meet the continuous insulation requirements of the 2018 International Energy Conservation Code (IECC, 2018) in all climate zones and has a much thinner profile that will facilitate its application to existing residential homes without the need for expensive retrimming of the architectural details. The paper will supply information on the development of the technology, its thermal modelling, testing, voice of user sessions to solicit input from architects, designers, manufacturers, contractors, and installers, and a techno-economic analysis to gauge its competitiveness with existing product options.

Desjarlais, Andre Omer↗

Developing a Composite Vacuum Insulated Panel (VIP) Insulation/Vinyl Siding Composite Technology for Retrofitting Residential Walls

This paper reports on a project that has attempted to seize on an opportunity to take a giant leap forward in commercializing a technology that would address a key opportunity to achieve energy savings in the existing residential housing stock. It is typically very difficult to increase the R-value of the walls in existing residential housing as doing so from the inside is disruptive and there have not been good solutions to increase thermal envelope performance from the exterior through adding continuous insulation due to the additional work required to fit existing architectural features to the new wall thickness and to reclad the facade. A high thermal resistivity or R-value per inch product that can be used in these applications offers an excellent solution. This paper summarizes a three-year research project to a produce vacuum insulated panel (VIP)/vinyl siding that would have sufficient R-value to meet the continuous insulation requirements of the 2018 International Energy Conservation Code (IECC, 2018) in all climate zones and has a much thinner profile that will facilitate its application to existing residential homes without the need for expensive retrimming of the architectural details. The paper will supply information on the development of the technology, its thermal modelling, testing, voice of user sessions to solicit input from architects, designers, manufacturers, contractors, and installers, and a techno-economic analysis to gauge its competitiveness with existing product options.

Desjarlais, Andre↗

An Energy Codes Gap Analysis Field Study in the Southwest (Final Technical Report)

The primary goal of the “An Energy Codes Gap Analysis Field Study in the Southwest” project was to improve housing through strengthened building energy code implementation in two states, Colorado and Nevada, leading to greater energy and utility bill savings for households. Colorado is a home rule state. Nevada adopts a statewide code, but cities and counties must also adopt the code, making the state function like a home rule state. To broaden the impact of the project, an additional goal was to share and amplify project experiences, findings, and lessons that can be applied in other states. To achieve these goals, the project’s key objectives were to examine how residential energy codes are implemented in partner states; to use these findings to strengthen codes implementation through enhanced education, training, and outreach; and to enhance energy code technical assistance capabilities in the two partner states. In both partner states, the project led to the creation of a quantitative baseline understanding of compliance with high-impact energy code requirements, such as foundation, wall, and ceiling R-value; window U-factor and SHGC; envelope air tightness; duct tightness; and high-efficiency lighting. It then applied this baseline information to directly inform training in geographic areas with high levels of building and construction activity. The project has placed Colorado and Nevada among 23 states across the country that have conducted a single-family residential field study based on the established U.S. Department of Energy (DOE) methodology since 2014. It has also helped each State Energy Office test models for partnership- and relationship-building among government agencies and key stakeholder groups, including the State Energy Office and relevant code administration and professional licensing agencies, building officials, designers, builders, trades and utilities. At the national level, the project helped educate and inform State and Territory Energy Offices on a replicable methodology to assess energy code construction practices, effective stakeholder engagement strategies, and tailored energy code education and training. These findings are particularly pertinent for home-rule states, such as Colorado and Nevada, which rely on local government awareness and action to advance and implement building energy codes. By raising awareness of code adoption and compliance, this project has helped to equip each partner state with data on code compliance, strategies, education, and partnership models to advance building energy codes. This in turn will have an important impact on new construction practices in Colorado and Nevada, leading to more energy efficient and affordable housing. Currently, more than 62 percent of Colorado’s population lives in one of the 55 jurisdictions that have adopted the 2021 IECC to date, while nearly 95 percent of the state's population lives in one of the 208 jurisdictions that have adopted a code at 2015 IECC levels or higher. In Nevada, the 2018 IECC was adopted by the Governor’s Office of Energy in July 2018. By July 2020, 47 percent of the adopted energy code in the state was 2018 IECC which covers 96.5 percent of Nevada’s population. The training materials funded by this project focus on the 2021 IECC and will continue to be relevant in the two states as additional jurisdictions update their building energy codes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An implicit particle code with exact energy and charge conservation for electromagnetic studies of dense plasmas

A collisional particle code based on implicit energy- and charge-conserving methods is presented. A modified version of the particle-suppressed Jacobian-Free Newton-Krylov method that can enhance the solver efficiency is introduced. Mathematically, it is shown that this new approach can be viewed as a fixed-point iteration method for the particle positions. The model can exactly conserve global energy and local charge and can efficiently use time steps larger than the plasma period. In conclusion, the algorithm's ability to simulate dense plasmas accurately and efficiently is quantified by simulating the dynamic compression of a plasma slab via a magnetic piston in 1D planar geometry.

97 MATHEMATICS AND COMPUTING↗

An implicit particle code with exact energy and charge conservation for studies of dense plasmas in axisymmetric geometries

A collisional particle code based on implicit energy- and charge-conserving methods in axisymmetric geometries is presented. A new particle pusher for axisymmetric systems is introduced that is compatible with exact energy and charge conservation and yields improved accuracy compared to other methods. How to appropriately treat all aspects of the algorithm near the r = 0 axis of symmetry is described in detail. Here, the axisymmetric model is verified by simulating the free expansion of a plasma sphere in 2D cylindrical and 1D spherical geometries. The algorithm's ability to study the dynamic compression of a dense plasma is illustrated by simulating the dynamic Z-pinch in 1D cylindrical geometry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

EUI Benchmarks for Net-Zero Energy Buildings in India

In our study we present EUI benchmarks for NZEBs for six building types across residential and non-residential typologies and for India's five climate zones. This approach is similar to the simulation-based benchmarks used by the B3 program in Minnesota, the Cal-Arch methodology in California, and the US Solar Decathlon approach, which combine simulations with actual building data. Of the six building types we explore one in detail with a range of operation scenarios, specifically narrowing down the EUI benchmarks for mixed-mode building operation and for variable temperature set-points as prescribed in the National Building Code of India.The contribution of this work is to provide rigorous end-use level EUI benchmarks for six building types, and to describe a method for simulation-based EUI benchmarks for mixed-mode operation with variable setpoints to highlight the difference between the standard approach used for the five building types and the On-Site Construction Worker Housing which additionally has the mixed-mode variable setpoint approach.On-Site Construction Worker Housings are typically poorly constructed temporary structures, without adequate thermal comfort, It is critical to provide adequate thermal comfort to protect people from the warming effects of climate change, and to discover super efficient and cost-effective ways to do so.The methodology used for the On-Site Construction Worker Housing (CWH) results in an 80% acceptability according to the India Model for Adaptive Comfort in the National Building Code of India. EUIs of all six buildings are 60% lower than the minimum compliance with India's Energy Conservation Building Codes, providing benchmarks for efficiency levels. The end-use level EUI benchmarks are now provided to over 1800 Solar Decathlon India participants so that they can compare the performance of their NZEB designs.In particular, the CWH results provide an insight into the importance of the mixed-mode operation with variable temperature set-points. The results from the simulation study show that for an NZEB target, the EUI with standard thermal comfort model and without mixed operation is 58.26 kWh/m2*year, while that with the variable set-points of the adaptive model with mixed mode operation is 24.23 kWh/m2*year. This is a 58% reduction in EUI. Given that many building types including residential, and non-residential operate in mixed mode, it is important to take this work further to develop mixed-mode operation NZEB benchmarks so that the carbon intensity of these buildings could be lower than the standard thermal comfort model approach.

benchmarking↗

Commercial Building Energy Code Field Study (Final Report)

What is the dollar value of increasing compliance with the energy code? Ultimately, this is the question that policy makers, funders, and program implementers care about. With this in mind, Pacific Northwest National Laboratory (PNNL) developed a new methodology capable of determining how much energy cost savings could potentially be gained through better compliance with the code (Rosenberg et al. 2016). On March 2, 2016 DOE issued Funding Opportunity Announcement (FOA) Number DE-FOA-0001532, requesting proposals to develop and test a methodology for identifying the commercial energy code requirements that can provide the maximum cost-effective energy and cost savings through increased compliance. Awarded to the Institute for Market Transformation, this report summarizes the development and testing of a commercial code compliance methodology, including a summary of results, statistical analysis of sample, and best practices for others implementing a commercial energy code compliance field study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Resolution requirements for energy conservation in kinetic plasma simulations

The kinetic codes used to model the coupled dynamics of electromagnetic fields and charged particle transport have requirements for spatial, temporal, and charge resolution. These requirements may vary by the solution technique and scope of the problem. In this report, we investigate the resolution limits in the energy-conserving implicit particle-in-cell code CHICAGO. This report has the narrow aim of determining the maximum acceptable grid spacing for the dense plasmas generated in models of z-pinch target gases and power-flow electrode plasmas. In the 2D sample problem, the plasma drifts without external forces with velocity of 10 cm/µs. Simulations are scaled by plasma density to maintain uniform strides across the plasma and from the plasma to the boundaries. Additionally, the cloud-in-cell technique is used with 400 particles per cell and Δ t = 0.85× the Courant limit. For the linear cloud distribution, the criterion for conserving energy is Δ E/E tot < 0.01 for 50,000 time steps. The grid resolution is determined to crudely be Δx ≲ 3 l s , where l s is the electron collisionless skin depth. For the second-order cloud distribution the criterion is Δ E/E tot < 0.005 yielding Δx ≤ 15 l s . These scalings are functions of the chosen v d , Δ t , particles-per-cell, and number of steps.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Particle-in-cell simulations of burning inertial confinement fusion capsule implosions

Anomalies observed in the neutron spectral shift of high-yield shots at the National Ignition Facility (NIF) suggest the presence of suprathermal ions [E. P. Hartouni et al., Nat. Phys. 19, 72 (2023)], implying that kinetic effects play a significant role in burning inertial confinement fusion (ICF) plasmas. Furthermore, recent measurements of reaction-in-flight (RIF) neutrons offer a direct probe of the stopping power in the burning fuel region of high-energy alpha particles and up-scattered fuel ions. We have developed the particle-in-cell code PICNIC, an exactly energy-conserving particle-in-cell Monte-Carlo collision (PIC-MCC) code to simulate the burn stage in ICF. We present results from 1D spherical simulations of NIF shot N210808, which was the first to exceed the Lawson criterion for laser fusion. We find that the suprathermal ions generated by large-angle Rutherford and nuclear elastic scattering (NES) with fusion alphas produce an alpha knock-on neutron (AKN) signal consistent with the extent and relative yield of the AKN spectrum identified in ignition experiments at the NIF. Furthermore, we also find that the inclusion of large-angle scattering physics does not explain the anomalously large spectral shift observed in the experiment.

High-energy-density plasmas↗

Semi-coupled flow and thermal analysis of the field joint during rapid pressurization of the redesigned solid rocket motor

A transient, semi-coupled, multi-dimensional thermal and flow analysis methodology was developed to predict the thermal/gas dynamic conditions in the field joint region of the Redesigned Solid Rocket Motor (RSRM). Transient temperature response, pressure history, and combustion gas flow rate (within the field joint region), were of principle interest, in the course of this study. The thermal environment in the field joint was modeled using SINDA, a finite difference based thermal network analyzer. The combustion gas flow boundary condition was generated using the FLAP code; this code performs a transient, lumped-parameter, control volume analysis to solve the mass, momentum, and energy conservation equations. The FLAP computer code was modified to account for erosion of the NBR insulation material, following ignition. An independent grid sensitivity study was conducted to determine an appropriate grid distribution near the wall. The predicted results, obtained using an optimum grid distribution and computer generated flow boundary condition, were compared with subscale test data.

Ghaffarian, Benny↗

Modeling cross-beam energy transfer with sector ray tracing

Ray-based cross-beam energy transfer (CBET) models are an essential feature of the radiation-hydrodynamic codes used to simulate inertial confinement fusion implosions, but full 3D ray-based CBET calculations can have a prohibitively high computational cost. Sector ray tracing can be used to reduce the cost by orders of magnitude in cases where the coronal plasma and laser drive can be approximated as spherically symmetric. An extension of sector ray tracing (section ray tracing) can be used to relax the assumption of a spherically symmetric drive while still retaining most of the computational savings of a sector ray trace. We discuss the foundations of sector and section ray tracing and compare them to full ray tracing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tunnel Event 2020 (G-tunnel event modeling) [Slides]

HOSS (Hybrid Optimization Software Suite) is a fracture mechanics code that properly conserves mass, energy and momentum. HOSS-FSIS was utilized to conduct exploratory calculations (2D plane strain/3D) for the G-tunnel event 2020 where a pseudo NPE 1.1kt HE equivalent source is used. The purpose of this analysis is to determine if the HOSS fluid-solid coupling solver can capture relevant down-tunnel phenomenology.

42 ENGINEERING↗

Explicit Modeling of Pebble Temperature in the Porous-medium Framework for Pebble-bed Reactors Applications

In this study, an explicit model for pebble temperature calculations in the framework of a porous-medium approach has been developed and implemented in the SAM code. The solid-phase energy conservation equation, including the explicit modeling of pebble temperature, is a multi-scale model, which can predict the macroscopic (pebble-bed) and microscopic (pebble) temperature distributions under both steady-state and transient conditions. Extensive and successful code verifications and demonstrations have been performed for this newly developed model. By explicitly modeling pebble temperatures, this new model addresses a major deficiency of the previously implemented model, which assumed a local solid-phase thermal equilibrium that is not appropriate for pebble-bed reactor design and safety analysis applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Environmental Impact of Deep Energy Retrofits in Residential Construction

Almost two thirds of the residential homes in the U.S. were constructed before the Department of Energy implemented energy conservation measures that were later formalized in the building codes. To reduce energy consumption and carbon emissions from the built environment, improvement to the existing housing stock is a prerequisite. However, improvements that lower energy consumption address carbon emissions related to heating, cooling and plug loads but not the embodied carbon of the building materials that also contribute to global carbon emissions. As the enclosure is made more efficient a larger portion of total carbon emissions is embodied carbon from the building materials. To mitigate carbon emissions, a holistic approach is required so that any improvement to the home results in a net reduction in carbon emissions. To understand the overall environmental impact of building enclosure improvements, the embodied and operational carbon emissions are calculated in this investigation and compared to the overall energy savings associated with enclosure improvements. The energy savings together with a reduction in operational carbon emissions are calculated using a novel building envelope metric. The net carbon emissions are then determined before and after the energy improvement measures. This approach allows or enables architects and builders to select designs that result in maximizing the overall reduction in energy and carbon emissions.

Aldykiewicz Jr, Antonio↗