A method of treating the non-grey error in total emittance measurements
Calculating non-grey errors in total emittance measurements as function of temperature control coating thickness
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Calculating non-grey errors in total emittance measurements as function of temperature control coating thickness
Accurate measurement of electron beam emittance is essential for optimizing high-brightness electron sources. The Pinhole Scan Technique measures the 4D phase space and hence the emittance by measuring the beam profile after clipping the beam using a pinhole followed by a drift section and then scanning the beam over the pinhole. This technique has been implemented in low energy (< 200 keV) beamlines at both Cornell University and Arizona State University. However, the technique poses several practical challenges. In this work, we analyze and address key issues affecting the 4D phase space and emittance measurements using this technique. We identify and investigate sources of inaccuracies like the pinhole aspect ratio, beam divergence, position-momentum correlations in the phase space, and the point-spread-function of the detector and suggest techniques to minimize them. Our findings offer a pathway to more accurate 4D phase space characterization in advanced electron beam systems.
Emittance measurement for temperatures to 3000-deg f to provide data on thermal radiation of ceramics for reentry vehicle use
Theoretical and experimental determinations of the emittance of soils and leaves are reviewed, and an error analysis of emittance and spectral emittance measurements is developed as an aid to remote sensing applications. In particular, an equation for the upper bound of the absolute error in an emittance determination is derived. The absolute error is found to decrease with an increase in contact temperature and to increase with an increase in environmental integrated radiant flux density. The difference between temperature and band radiance temperature is plotted as a function of emittance for the wavelength intervals 4.5 to 5.5 microns, 8 to 13.5 microns and 10.2 to 12.5 microns.
Emittance measurements of ceramic coatings up to 2900 deg kelvin
Infrared spectral emittance measurements of rocks from Mono Craters region, California
A technique to reduce point-spread originating from physical slit width in emittance measurements is described. This technique is developed to improve phase resolution in a longitudinal emittance apparatus consisting of a dipole magnet, energy-selecting slit and bunch shape monitor. In this apparatus, the energy and phase resolutions are directly proportional to the width of the slit, but the virtual slit method enables sub-slit resolution. The bunch phase profile is measured at two points in the energy distribution with a separation less than the physical slit width. The difference of these two profiles is used to reconstruct the profile from a virtual slit of width equal to the separation.
Micro/nanostructures play a key role in tuning the radiative properties of materials and have been applied to the high-temperature energy conversion systems for improved performance. Among the various radiative properties, spectral emittance is of integral importance for the design and analysis of materials that function as radiative absorbers or emitters. This article presents an overview of the spectral emittance measurement techniques using both the direct and indirect methods. Several micro/nanostructures are also introduced, and a special emphasis is placed on the emissometers developed for characterizing engineered micro/nanostructures in high-temperature applications (e.g., solar energy conversion and thermophotovoltaic devices). Both experimental facilities and measured results for different materials are summarized. Future prospects in developing instrumentation and micro/nanostructured surfaces for practical applications are also outlined. This study provides a comprehensive source of information for the application of micro/nanostructures in high-temperature energy conversion engineering.
We present PyEmittance: a new Python package for general particle beam emittance measurements that offers adaptive quadrupole scans and is designed for robust and flexible integration with Python-based software, with online accelerators, and with simulation software. It is open source software, and can be installed via the command pip install pyemittance.
The Mid Infrared Instrument aboard the James Webb Space Telescoep includes a mechanical cryocooler which cools its detectors to their 6 K operating temperature. The refrigerant flows through several meters of approximately 2 mm diameter 304L stainless steel tubing, with some sections gold plated, and some not, which are exposed to their environment. An issue of water freezing onto the tube surfaces is mitigated by a running a warm gas through the lines to sublimate the water. To model the effect of this process on nearby instruments, an accurate measure of the tube emittance is needed. Previously we reported the abosprtance of the gold plated stainless steel tubing as a function of source temperature (i.e. its environment). In this work the thermal emittance of the uncoated tubing is measured as a function of its temperature between 100 and 300 K. This value leads to an accurate prediction of the minimum length of time required to thermally recycle the system. We report the technique and present the results.
The Mid Infrared Instrument aboard the James Webb Space Telescope includes a mechanical cryocooler which cools its detectors to their 6 K operating temperature. The refrigerant flows through several meters of 2 mm diameter 304L stainless steel tubing, with some sections gold plated, and some not, which are exposed to their environment. An issue of water freezing onto the tube surfaces is mitigated by running a warm gas through the lines to sublimate the frozen water. To model the effect of this process on nearby instruments, an accurate measure of the tube emittance is needed. Previously we reported the absorptance of the gold plated stainless steel tubing as a function of source temperature (i.e. its environment). In this work the thermal emittance of the uncoated tubing is measured as a function of its temperature between 100 and 280 K. These values lead to an accurate prediction of the minimum length of time required to thermally recycle the system. We report the technique and present the results.
A short pulse high gradient RF gun has been recently tested at Argonne Wakefield Accelerator (AWA) facility. The carried-out test showed that the 1,5-cell gun was able to inject 3 MeV, up to 100 pC bunches at room tem-perature being fed by 9 ns up to 300 MW 11.7 GHz puls-es. The cathode field was as high as about 400 MV/m. So high field is aimed to mitigate repealing Coulomb forces substantially. In accordance with simulations the emit-tance could be as low as less than 0.2 mcm. To obtain so low emittance in the experiment, the gun is assumed to be equipped with a downstream linac to be fed from the same power extractor as the gun itself. Here we report design of the RF power distribution system splitting RF power among the gun and the linac, results of low-power tests, and emittance measurement plans for upcoming new experiment at AWA.
IR directional and hemispherical emittance of spacecraft thermal control coatings, comparing values determined by various measurement techniques
Calorimetric measurements determining total hemispheric emittance of thin gold films as function of temperature, demonstrating film thickness effect
Calorimetric measurements determining total hemispheric emittance of thin gold films as function of temperature, demonstrating film thickness effect
Instrumentation for simultaneous measurement of spectral and normal emittance of materials in ambient and vacuum environment at high temperature
Calorimetric measurements of the total hemispherical emittance of a section of polished aluminum support tubing from the Surveyor 3 spacecraft are reported. The values found, 0.090 at 25 C and 0.089 at 50 C, are lower than was expected from a visual estimate but are in good agreement with an estimate based upon scanning electron microscopy of the tubing.