Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “emergency management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

PR100: Puerto Rico Grid Resilience and Transition to 100% Renewable Energy [Slides]

Puerto Rico has committed to meeting its electricity needs with 100% renewable energy by 2050. The PR100: Puerto Rico Grid Resilience and Transition to 100% Renewable Energy study, led by the National Renewable Energy Laboratory (NREL), will leverage world-class expertise, cross-sector modeling capabilities, and community engagement to generate feasible pathways to affordable and reliable electricity across the archipelago. PR100 is being funded by the Federal Emergency Management Agency through an interagency agreement with DOE's Office of Electricity to support recovery efforts in the island's energy sector leveraging the expertise and capabilities of the National Laboratories including Argonne, Lawrence Berkeley, NREL, Oak Ridge, Pacific Northwest, and Sandia. The public is invited to this virtual launch event to learn more about the scope and benefits of the study and opportunities for engagement. Welcoming remarks will be provided by Jennifer M. Granholm, Secretary of the U.S. Department of Energy; Martin Keller, Director of the National Renewable Energy Laboratory; and Deanne Criswell, Administrator of the Federal Emergency Management Agency.

100% renewable energy↗

BESS Digital Assurance, Supply Chain Risk Management, and Emerging Regulation Session One - Abridged

The TADA BESS Supply Chain Workshops are designed to equip participants with the knowledge and tools necessary to address the evolving challenges at the intersection of battery energy storage systems (BESS), cybersecurity, and supply chain vulnerabilities. The workshops emphasize the application of Cyber-Informed Engineering (CIE) principles using INL’s procurement guide and the CIE-BAT tool. Attendees will develop risk-based security strategies and actionable compliance roadmaps tailored to their BESS projects. Additionally, the program fosters a collaborative network of practitioners and provides guidance on navigating emerging regulatory requirements, including FEOC rules under the OBBB framework, to assess and enhance organizational readiness. This is Session 1 of 3.

25 - ENERGY STORAGE↗

BESS Digital Assurance, Supply Chain Risk Management, and Emerging Regulation Session Two

The TADA BESS Supply Chain Workshops are designed to equip participants with the knowledge and tools necessary to address the evolving challenges at the intersection of battery energy storage systems (BESS), cybersecurity, and supply chain vulnerabilities. The workshops emphasize the application of Cyber-Informed Engineering (CIE) principles using INL’s procurement guide and the CIE-BAT tool. Attendees will develop risk-based security strategies and actionable compliance roadmaps tailored to their BESS projects. Additionally, the program fosters a collaborative network of practitioners and provides guidance on navigating emerging regulatory requirements, including FEOC rules under the OBBB framework, to assess and enhance organizational readiness. A comprehensive exploration of BESS cybersecurity supply chain risks, systematic vendor risk assessment through the BESS Procurement Guide, and practical application of the INL SCRM Chatbot for enhanced supply chain resilience. This is Session 2 of 3. (Full Version)

25 - ENERGY STORAGE↗

BESS Digital Assurance, Supply Chain Risk Management, and Emerging Regulation Session One

The TADA BESS Supply Chain Workshops are designed to equip participants with the knowledge and tools necessary to address the evolving challenges at the intersection of battery energy storage systems (BESS), cybersecurity, and supply chain vulnerabilities. The workshops emphasize the application of Cyber-Informed Engineering (CIE) principles using INL’s procurement guide and the CIE-BAT tool. Attendees will develop risk-based security strategies and actionable compliance roadmaps tailored to their BESS projects. Additionally, the program fosters a collaborative network of practitioners and provides guidance on navigating emerging regulatory requirements, including FEOC rules under the OBBB framework, to assess and enhance organizational readiness. This is Session 1 of 3. (Full Version)

25 - ENERGY STORAGE↗

Hurricane Helene: Energy Systems Impact and Situational Insights in East Tennessee

This situational report focuses specifically on energy system performance and interdependencies associated with Hurricane Helene’s impacts across East Tennessee. It does not attempt to identify root causes, evaluate broader emergency response structures, or assess agency effectiveness. Rather, it aims to illuminate how energy disruptions intersected with other lifeline services, particularly water, transportation, and communications, and identify the infrastructural and logistical conditions that shaped those outcomes. Where possible, this report seeks to highlight both constraints and successful practices that emerged during the event.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Advances in the Application and Utility of Subseasonal-to-Seasonal Predictions

The subseasonal-to-seasonal (S2S) predictive time scale, encompassing lead times ranging from 2 weeks to a season, is at the frontier of forecasting science. Forecasts on this time scale provide opportunities for enhanced application-focused capabilities to complement existing weather and climate services and products. There is, however, a “knowledge–value” gap, where a lack of evidence and awareness of the potential socioeconomic benefits of S2S forecasts limits their wider uptake. To address this gap, here we present the first global community effort at summarizing relevant applications of S2S forecasts to guide further decision-making and support the continued development of S2S forecasts and related services. Focusing on 12 sectoral case studies spanning public health, agriculture, water resource management, renewable energy and utilities, and emergency management and response, we draw on recent advancements to explore their application and utility. These case studies mark a significant step forward in moving from potential to actual S2S forecasting applications. We show that by placing user needs at the forefront of S2S forecast development—demonstrating both skill and utility across sectors—this dialogue can be used to help promote and accelerate the awareness, value, and cogeneration of S2S forecasts. We also highlight that while S2S forecasts are increasingly gaining interest among users, incorporating probabilistic S2S forecasts into existing decision-making operations is not trivial. Nevertheless, S2S forecasting represents a significant opportunity to generate useful, usable, and actionable forecast applications for and with users that will increasingly unlock the potential of this forecasting time scale.

54 ENVIRONMENTAL SCIENCES↗

Lac du Flambeau - Climate Change Resilience Initiative (Final Report)

The goals of this project were to create a comprehensive Environmental Resiliency Plan and to increase the capacity of all Lac du Flambeau Tribal Program Managers to incorporate environmental impact thinking into the everyday management of their departments. Environmental Resiliency Planning utilized current Tribal documents, which include the Integrated Resource Management Plan (IRMP), the Lac du Flambeau Tribal Emergency Management Plan (EMP), and the Lac du Flambeau Strategic Energy Plan, as guidance throughout the process. A vulnerability assessment initiated our technical process and allowed us to identify, quantify, and prioritize (or rank) the vulnerabilities in our system. This set the stage for a reduction and resilience plan as well as providing insight for revisions of existing management plans such as the Energy and Integrated Resources Management Plans

54 ENVIRONMENTAL SCIENCES↗

Health Analysis and Research for Public Events (HARPE) Tool (Final CRADA Report)

Based on its experience in building assessment tools, Argonne National Laboratory (Argonne) has demonstrated expertise in developing comparative methodologies and question sets that provide both a physical and cyber-based risk assessment for the commercial facilities sector. A high-level risk assessment tool can be beneficial for venues and organizations that fall under a wide array of facility characterizations, ultimately accommodating the evolving landscape of threats specific to these facilities. The Health Analysis and Research for Public Events (HARPE) Tool is an assessment that seeks to help facility managers assess and mitigate aspects of safety, security, and emergency management within their venues. With the pandemic featuring prominently in today’s landscape, we have adapted and extended the scope of the HARPE tool so that it offers users the ability to integrate assessments of their preparation for, response to, and recovery from threats faced at the venue arising from the COVID-19 pandemic. Traditional threats and hazards remain prevalent in today’s landscape, and the best defense is a proactive approach to preventing and mitigating these threats. At the very core of prevention and mitigation is the first step of conducting a risk assessment—this is the gap that HARPE fills. While it is obvious that the response to COVID-19 is health and sanitation driven, leaders within the commercial facilities sector must also know where to best extend their efforts in mitigating future threats arising from the pandemic. Public events and mass gatherings are directly impacted by COVID-19; however, with the help of HARPE, leaders can focus their attention on core impact areas related to the safety and security of returning to a new normal, as they assess their risks using the Argonne-developed tool. HARPE provides an important solution to the COVID-19 situation by assisting venue managers and health officials in identifying their risks.

59 BASIC BIOLOGICAL SCIENCES↗

Monitoring and Documentation of Forest Management Activities at Los Alamos National Laboratory

Forest management treatments at Los Alamos National Laboratory (LANL) are administered by the Emergency Management Division (EMD-DO) Wildland Fire Program within the Wildland Fire and Forest Management Program (WFFM Program or the Program). Open space forest inventory monitoring is conducted by Forest Health Program staff and students within the Environmental Stewardship Group (EPC-ES). The goals of the integrated Wildland Fire and Forest Management Program are to reduce impacts to Laboratory operations from climate driven events by implementing forest management and healthy forest initiatives such as forest thinning and erosion control. The LANL Wildland Fire Mitigation and Forest Health Plan (EMD PLAN-200, LA-UR-19-25122; LANL 2019) presents treatment standards for LANL property to meet the following goals: 1) Restore and maintain landscapes: LANL landscapes are resilient to disturbances; 2) Develop a fire-adapted community: LANL workforce, neighbors, and infrastructure can withstand a wildland fire without loss of life and property; 3) Ensure wildland fire mitigation implementation: All wildland fire mitigation working group organizations participate in making and implementing safe, effective, efficient risk-based wildland fire management decisions.

54 ENVIRONMENTAL SCIENCES↗

The FLOod Probability Interpolation Tool (FLOPIT): A Simple Tool to Improve Spatial Flood Probability Quantification and Communication

Understanding flood probabilities is essential to making sound decisions about flood-risk management. Many people rely on flood probability maps to inform decisions about purchasing flood insurance, buying or selling real-estate, flood-proofing a house, or managing floodplain development. Current flood probability maps typically use flood zones (for example the 1 in 100 or 1 in 500-year flood zones) to communicate flooding probabilities. However, this choice of communication format can miss important details and lead to biased risk assessments. Here we develop, test, and demonstrate the FLOod Probability Interpolation Tool (FLOPIT). FLOPIT interpolates flood probabilities between water surface elevation to produce continuous flood-probability maps. FLOPIT uses water surface elevation inundation maps for at least two return periods and creates Annual Exceedance Probability (AEP) as well as inundation maps for new return levels. Potential advantages of FLOPIT include being open-source, relatively easy to implement, capable of creating inundation maps from agencies other than FEMA, and applicable to locations where FEMA published flood inundation maps but not flood probability. Using publicly available data from the Federal Emergency Management Agency (FEMA) flood risk databases as well as state and national datasets, we produce continuous flood-probability maps at three example locations in the United States: Houston (TX), Muncy (PA), and Selinsgrove (PA). We find that the discrete flood zones generally communicate substantially lower flood probabilities than the continuous estimates.

54 ENVIRONMENTAL SCIENCES↗

Manatee County Clear Sky Assessment Process: Prioritizing Solar + Storage for Resilient Facilities & Communities

The Clear Sky Tampa Bay project was a 15-month collaborative research effort to support solar + storage deployment for community resilience in Florida. The Clear Sky Decision Support Toolkit is a collection of resources designed to support users in conducting solar + storage prioritization and feasibility screening assessments at critical facilities. The Tampa Bay Regional Planning Council worked with four local governments in the region to test and apply the Toolkit. This case study series describes how each partner government used the Toolkit and highlights key insights and lessons learned that other users could follow to replicate the process. Manatee County applied the Clear Sky Decision Support Toolkit to two of the county's critical facilities: Nolan Middle School, which serves as a special needs emergency shelter, and its Public Safety Complex (PSC), which houses critical services including emergency management, communications, and medical services, traffic control, and more. The PSC serves as the Emergency Operations Center during activation events. The Clear Sky assessment process improved interagency communication and coordination and informed siting decisions for a potential solar + storage system for the Manatee County PSC.

14 SOLAR ENERGY↗

Apple Bitter Rot: Biology, Ecology, Omics, Virulence Factors, and Management of Causal Colletotrichum Species

ABSTRACT Apple bitter rot is caused by various Colletotrichum spp. that threaten apple production globally resulting in millions of dollars in damage annually. The fungus causes a decline in fruit quality and yield, eventually rotting the fruit and rendering it inedible. The pathogen is difficult to keep out of orchards because of its broad host range and transmissibility by rain splash and insects. Once the disease manifests, pathogen identification is difficult due to evolving taxonomy and similar morphology between species. Current management strategies are threatened by an increase in fungicide resistance and regulations on many multisite fungicides, leading to a pressing need for new management options for control. This review aims to summarise the most current knowledge regarding the biology, virulence factors, ecology, omics and emerging management strategies for Colletotrichum species that cause apple bitter rot. Taxonomy Colletotrichum species—Domain Eukaryota, Kingdom Fungi, Phylum Ascomycota, Class Sordariomycetes, Order Glomerellales, Family Glomerellaceae, Genus Colletotrichum . Biology Hemibiotrophic pathogen with a wide host range that establishes a biotrophic interaction where it penetrates host plants using appressoria followed by a switch to necrotrophy causing rot symptoms. Toxins Cercosporin, colletotrichins, colletotric acid, ferricrocin. Host Range The host range varies by species but largely occurs on dicotyledonous plants and is less prevalent on monocots as well as gymnosperms, ferns, mosses and animals (e.g., insects). Disease Symptoms Symptoms often manifest as flat to sunken necrotic areas on fruit. Lesions on leaves and fruit can have concentric rings with abundant pathogen sporulation. Disease Control Colletotrichum spp. are primarily managed by single‐site quinone outside inhibitor (Qol), methyl benzimidazole carbamate (MBC), demethylation inhibitor (DMI) fungicides, and multisite dithiocarbamate and phthalimide fungicides. Susceptibility may vary with species, strain specificity, or geographic region. Other management options include clean stock production, cultural practices, resistance breeding, and biological control through the introduction of protective or competing microorganisms.

Boeckman, Nathanial J. [Plant Pathology Laboratory↗

Field surveying data of low-cost networked flood sensors in southeast Texas

Floods are common natural disasters worldwide and pose substantial risks to life, property, food production, and natural resources. Effective measures for flood mitigation and warning are essential. Southeast Texas is still at significant risk of flooding, and Lamar University is assisting the region with asset management of a flood sensor network for flooding events. This network provides real-time water stage information. Lamar University developed a survey program to measure elevation and coordinates at each sensor site location to make this data more useful for flood monitoring and mapping. This paper overviews the measurement of the elevation and coordinates of 74 networked flood sensors and various flood stage thresholds at critical points that flood decision-makers can use for reference at each site. In the first phase of this program, these sensors were deployed throughout a 7-county region spanning nearly 6,000 square miles in Southeast Texas. The latitude and longitude of the sensors and their elevations were determined using survey-grade Global Navigation Satellite System (GNSS) technology. Various Continually Operating Reference Stations (CORS) were utilized for post-processing to achieve sub-inch resolution. The flood stage thresholds, water level sensors elevation, and the elevations and positions of other critical surrounding points are viewable to the public through two online repositories and a web-based sensor management dashboard. The data is used to aid with decisions related to road closures or modeling efforts by mitigation decision-makers, emergency managers, and the public, including the Texas Department of Transportation, Houston Transtar, the National Weather Service, and the Sabine River Authority of Texas (SRA).

54 ENVIRONMENTAL SCIENCES↗

Bridge Seismic Screening Tool (BSST), Version 2.0

The Regional Resiliency Assessment Program (RRAP) is a cooperative assessment of specific critical infrastructure within a designated geographic area and a regional analysis of the surrounding infrastructure that addresses a range of infrastructure resilience issues that could have regionally and nationally significant consequences. In 2018, DHS’s Cybersecurity and Infrastructure Security Agency (CISA) sponsored the Oregon Transportation Systems RRAP project in coordination with the Office of the Governor (under the oversight of the state resilience officer), the Oregon Office of Emergency Management (OEM), the Oregon Department of Transportation (ODOT), and other regional stakeholders (CISA 2021). This project focuses on assessing the impacts of a Cascadia Subduction Zone (CSZ) earthquake on state transportation systems and, in particular, how those impacts may affect the ability of emergency response efforts to move supplies into the region. The intended outcome of this analysis is the prioritization of transportation routes and modes for additional planning, investment, hardening, or other activities to enhance their resilience—and therefore, to enhance their ability to support response and recovery efforts following a CSZ earthquake. An important part of this transportation system-level assessment has been to assess the seismic vulnerability of the state highway system. In doing so, the RRAP project team used the Bridge Seismic Screening Tool (BSST) to assess, at a system-level, the potential impacts that a CSZ earthquake could have on state highway bridges (Bergerson et al. 2019).1 Argonne National Laboratory (Argonne), in collaboration with the Washington State Department of Transportation (WSDOT), originally developed the BSST as part of the 2017 Washington State Transportation Systems RRAP project, a sister project to the 2018 Oregon Transportation Systems RRAP project. Argonne updated the BSST during this more recent project in Oregon based on feedback from stakeholders and subject matter experts (SMEs) on the original version of the tool. The first step in the BSST is to assess the seismic vulnerability of roadway bridges following a CSZ earthquake to determine a projected or potential damage state. Damage states then help determine approximate reopening times for bridge crossings.2 This document provides details on the BSST methodology, the implementation of that tool to analyze the projected damage incurred in a CSZ earthquake scenario, and the determination of corresponding reopening times of interstate, state highway, and local bridges following such an event.

58 GEOSCIENCES↗

Meteorological Tower Network Expansion Pilot Project Siting Considerations to Ensure Data Quality and Representativeness of Three New Meteorological Towers at Los Alamos National Laboratory

Associated with the Meteorological Tower Network Expansion Pilot Project by the Environmental Protection and Compliance (EPC) Compliance Programs (CP) Meteorology and Air Quality (MAQ) team, the purpose of this technical report is to establish requisite justification for the siting of three 10-meter high instrumented meteorological towers at three new locations on the Los Alamos National Laboratory (LANL) site. These towers and their associated instrumentation are similar in scope to the existing 10-meter meteorological tower that is collecting meteorological data in Mortandad Canyon (MDCN). The conclusions and recommendations in this technical report will inform LANL management, EPC-CP MAQ staff, and other LANL divisions of the criteria employed for the selection of the final location for siting these three new towers. Meeting such comprehensive criteria will ensure that all data acquired will be spatially representative for meeting the diverse Safety Basis (SB), emergency management, and operations organizations programmatic needs and analytical data input requirements to its codes.

54 ENVIRONMENTAL SCIENCES↗

Power Supply Options for the Marpi Landfill, Saipan: Comprehensive Feasibility Study

The Marpi Landfill (“Marpi” or “the landfill”), located on the northern end of the island of Saipan in the Commonwealth of the Northern Mariana Islands (CNMI), is powered by a single on-site diesel generator that only operates when the landfill is open and staffed. The project team, composed of representatives of the Department of Public Works and the Office of Planning and Development (OPD), aspires to provide the Marpi Landfill with 24-hour power availability despite its remote location to increase the use of sustainable energy and to ensure environmentally compliant landfill operations. This is consistent with the sustainable development goals documented in the 2021–2030 Comprehensive Sustainable Development Plan (OPD 2021), including Goal #12 (ensure environmentally compliant waste management facilities) and Goal #7 (renewable energy deployment). Further, the CNMI has a 20% target for renewable energy consumption by 2030, as documented in the 2021–2030 Comprehensive Sustainable Development Plan (OPD 2021) and the renewable portfolio standard (Public Law 18-62). To accomplish these goals, the Federal Emergency Management Agency, through its Interagency Reimbursable Work Agreement with the U.S. Department of Energy, funded a feasibility study and follow-up study in 2023–2024 to assess and prioritize power supply options for the landfill. This report combines the results from both feasibility studies.

14 SOLAR ENERGY↗

Radiological Mapping of Nuclear Facilities

Identifying radiological abnormalities is critical during emergencies at nuclear facilities. This facilitates a necessity for the Emergency Management (EM) to map baseline radiation levels at the Idaho National Laboratory (INL). The INL uses scintillation detectors to measure radioactivity and gamma spectrums; but, because they are heavy and costly, these detectors can be impractical for mapping radiological areas. This presentation will establish initial radiological heat maps for emergencies and test the Radiacode-103G — a handheld scintillator with GPS and Bluetooth capability with a Gadolinium Aluminum Gallium Garnet (GAGG) crystal.

61 RADIATION PROTECTION AND DOSIMETRY↗

Accelerating Nuclear Facility Mission Completion Through an Improved Chemical Hazard Control Strategy - 20460

Code of Federal Regulation (CFR) 10 CFR 830, Nuclear Safety Management [1], explicitly identifies hazardous materials in addition to radioactive materials when establishing the scope of materials that must be evaluated in Hazard Category (HC) 1, 2, and 3 nuclear facilities. This inclusion has led to a near decade-long progression of more and more rigorous application of chemical hazard controls in these facilities. The progressive addition of more rigorous chemical hazard controls has occurred across the Department of Energy (DOE) Complex, having been driven by contractors and regulators alike. However, chemical hazards in other DOE facilities have been, and continue to be, controlled using traditional industrial safety centered strategies. Thus, identical chemical hazards are controlled using dramatically different approaches based solely on the facility type. Not only are the controls different, the analysis and derivation rigor and requirements are also significantly different. In particular, chemical control derivation and application in non-nuclear facilities are much less onerous than the comprehensive hazard analysis process used in nuclear facilities, even in circumstances in which chemicals are not initiators to, or do not exacerbate a nuclear event. While the derivation and control approaches used in these two types of facilities are disparate, the safety results are similarly effective based on a review of reported chemical events from 2014 through 2018. While both approaches achieve comparable safety outcomes, the approach used in nuclear facilities results in significantly greater preparation costs and implementation costs. Furthermore, the problem with the differing approach is not relegated to the control preparation and implementation burden. The operational impact of potentially unnecessary controls slows mission completion without a corresponding increase in safety, not to mention the dilution of the importance of Technical Safety Requirements. The proposed solution must first include a critical and thorough examination of DOE Complex and top-tier chemical industry chemical hazard control practices, coupled with a similar examination of the driving facility regulatory requirements. Results from the examination can then be used to fuel a bold departure from current chemical control practices in Hazard Category 1, 2, and 3 nuclear facilities. Development of an improved and consistent chemical hazard control process would follow, one that continues to ensure safety while accelerating mission completion and significantly reducing the burden associated with chemical hazard control development and implementation. The improved process must establish a hierarchy where radiological hazards are addressed using safety class and safety significant controls and chemical hazards are addressed using overarching safety management programs (with limited unique exceptions). The improved Hazard Category 1,2, and 3 nuclear facility chemical hazard control strategy, while compliant with 10 CFR 830 [1], would be founded on the requirements in 10 CFR 851, Worker Safety and Health Program [2], and the complementary DOE O 151.1D, Comprehensive Emergency Management System [3]. In this way, the Hazard Category 1, 2, and 3 nuclear facility chemical hazard control strategy would, wherever appropriate, be the same process used at other DOE Complex facilities. Ultimately, the improved process will maintain safety and significantly reduce costs and life cycle risk through faster mission completion. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗