Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic channel count”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Calibration of the underground muon detector of the Pierre Auger Observatory

To obtain direct measurements of the muon content of extensive air showers with energy above 10 16.5 eV, the Pierre Auger Observatory is currently being equipped with an underground muon detector (UMD), consisting of 219 10 m 2 -modules, each segmented into 64 scintillators coupled to silicon photomultipliers (SiPMs). Direct access to the shower muon content allows for the study of both of the composition of primary cosmic rays and of high-energy hadronic interactions in the forward direction. As the muon density can vary between tens of muons per m 2 close to the intersection of the shower axis with the ground to much less than one per m 2 when far away, the necessary broad dynamic range is achieved by the simultaneous implementation of two acquisition modes in the read-out electronics: the binary mode, tuned to count single muons, and the ADC mode, suited to measure a high number of them. In this work, we present the end-to-end calibration of the muon detector modules: first, the SiPMs are calibrated by means of the binary channel, and then, the ADC channel is calibrated using atmospheric muons, detected in parallel to the shower data acquisition. The laboratory and field measurements performed to develop the implementation of the full calibration chain of both binary and ADC channels are presented and discussed. The calibration procedure is reliable to work with the high amount of channels in the UMD, which will be operated continuously, in changing environmental conditions, for several years.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dual-sided charge-coupled devices

Existing charge-coupled devices (CCDs) operate by detecting either the electrons or holes created in an ionization event. Here, we propose an imager, the dual-sided CCD, which collects and measures both charge carriers on opposite sides of the device via a dual-buried channel architecture. We show that this dual detection strategy provides exceptional dark-count rejection and enhanced timing capabilities. These advancements have wide-ranging implications for dark-matter searches, near-infrared/optical spectroscopy, and time-domain x-ray astrophysics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A stilbene–strontium iodide based radioxenon detection system for monitoring nuclear explosions

Atmospheric measurement of noble gases has been extensively used for monitoring clandestine nuclear weapon explosions for many years. The ratios of four xenon isotopes of interest ( 131 mXe, 133 mXe, 133 Xe, and 135 Xe) help in discriminating regular reactor operations from nuclear tests. A new coincidence-based detection system using stilbene and strontium iodide [SrI 2 (Eu)] for electron and photon detection respectively was developed at Oregon State University to address some of the challenges of the radioxenon systems deployed in the field such as memory effect, and poor energy resolution. Silicon photomultipliers (SiPMs) were used for sensing optical photons from all scintillation media. Real-time coincidence identification was achieved using the eight-channel digital pulse processor. The detection system was evaluated using lab check sources and Oregon State TRIGA reactor irradiated radioxenon samples. A 48-hour background coincidence spectrum was collected yielding a coincidence count rate and background rejection rate of 0.0174 ± 0.0003 counts per second (cps) and 98.9% respectively. The minimum detectable concentration (MDC) of the system was evaluated to be 0.11 ± 0.01, 0.13 ± 0.02, 0.20 ± 0.02, and 0.73 ± 0.08 for 131 mXe, 133 mXe, 133 Xe, and 135 Xe respectively. The memory effect of the detection system was found to be 0.069 ± 0.015%, which is almost a 70-fold reduction compared to traditional plastic scintillators. Here, the detection elements, custom-designed electronics, and the detector response to radioxenon are detailed in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reaching For New Physics With MeV-scale Reconstruction In The MicroBooNE LArTPC Neutrino Detector

Large neutrino liquid argon time projection chamber (LArTPC) experiments can broaden their physics reach by reconstructing MeV-Scale energy depositions, or blips, in their data. We demonstrate new calorimetric and particle discrimination capabilities at the MeV scale using reconstructed blips in MicroBooNE LArTPC data at Fermilab. A concentration of low-energy ($<$3 MeV) blips is observed around fiberglass mechanical support struts along the TPC edges, with spectral features consistent with the Compton edge of the 2.614 MeV $^{208}$Tl decay $\gamma$ ray. With these features we perform the electron energy scale calibration to few-percent precision and yield the specific activity of $^{208}$Tl in the struts, $(11.7 \pm 0.2 \text{(stat)} \pm 2.8 \text{(syst)})$ Bq/kg. Using cosmogenic blips above 3 MeV, we demonstrate the ability of large LArTPCs to discriminate low-energy proton and electron depositions. An enriched low-energy proton sample selected with this technique is smaller in data than in dedicated CORSIKA simulations, pointing to possible mismodeling in CORSIKA incident cosmic fluxes or Geant4 particle transport. These methods are applied to MicroBooNE's inclusive single-photon search, which reported a 2.2$\sigma$ excess below 600 MeV in shower energy for events with no reconstructed protons. By identifying and classifying blips near single-photon events selected by the WireCell reconstruction framework, a more comprehensive labeling of nearby hadronic activity is established: blips upstream of the shower axis indicate previously unidentified final-state protons, while elevated blip counts at wide angles signal final-state neutrons. Taken together with MiniBooNE's long-standing low-energy excess (LEE) and MicroBooNE electron-like and sterile neutrino searches disfavored as possible explanations of the MiniBooNE anomaly, this analysis motivates an expanded exploration of the single-photon channel in Fermilab's short-baseline LArTPC program. This thesis documents the current status of this enhanced analysis, which will form a key part of MicroBooNE's final low-energy-excess results.

Andrade Aldana, Diego Armando [IIT, Chicago (main)↗

Development and evaluation of a list mode neutron coincidence collar for spatial response measurements of fresh fuel assemblies

A traditional safeguards neutron coincidence counting system, the Neutron Coincidence Collar, has been modified to incorporate individual preamplifiers on each of its 18 3He tubes in active interrogation mode. When used with list mode data acquisition (LMDA) and analysis, a signal from each 3He tube can be recorded and analyzed to allow a spatial response measurement to be performed on an item based on count rate and 3He tube location within the system. The ultimate goal of this project is to demonstrate the capabilities of a list mode response matrix for the nondestructive assay of fresh nuclear fuel assemblies. To enable partial defect detection of fuel pin locations and absences within an assembly, the project aims to extend well-established correlated neutron analysis techniques on a preexisting Neutron Coincidence Collar by extracting a greater number of useful signatures from the system than are currently generated. LMDA, combined with the addition of multiple preamplifiers, facilitates this capability by increasing the number of simultaneous signals that can be measured; this allows an in-depth analysis of neutron coincidence events to determine a fissioning item’s location based on the measured doubles count rate in various channel logic coincidence combinations. All of this can be done from a single measurement pulse train in offline analysis, which is the major benefit provided by LMDA. Through various stages of development and testing, a Mirion Technologies model JCC-71 Neutron Coincidence Collar has been successfully retrofit with modern electronics designed in-house at Oak Ridge National Laboratory, matching preexisting JAB-01 electronics performance, while maintaining the original system footprint. This paper presents these various stages of development and experimental evaluation of the proof of concept system.

Moore, Angela S.↗

Shot noise sets the limit of quantification in electrochemical measurements

Detection of single molecules, particles, and rapid redox events is a challenge of electrochemical investigations and requires either an amplification strategy or significant averaging for the electrochemical current to exceed the noise level. We consider the minimum number of electrons required to reach the limit of quantification in these electrochemical measurements. A survey of the literature indicates that the state-of-the-art limit in current detection for different types of measurements (e.g. voltammetry, single-molecule redox cycling, ion channel recordings of single molecules, metal nanoparticle collision, and phase nucleation) is independent of the nature of the measurement and increases linearly with reciprocal response time, Δt -1 , over ~5 orders of magnitude (from ~10 to ~10 6 s -1 ). This paper demonstrates that the practical limit of quantification requires cumulative measurement of ~2100 electrons during Δt and is determined by statistics of counting electrons, that is, the shot noise in the current.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

HRPPD photosensors for RICH detectors with a high resolution timing capability

Recently, a new version of DC-coupled High Rate Picosecond Photodetectors (DC-HRPPDs) substantially re-designed for use at the Electron-Ion Collider (EIC) has been developed. A first batch of seven “EIC HRPPDs” was manufactured in early 2024. These HRPPDs are DC-coupled photosensors based on Micro-Channel Plates (MCPs) that have an active area of 104 mm by 104 mm, 32 × 32 direct readout pixel array at a pitch of 3.25 mm, peak quantum efficiency in excess of 30%, exceptionally low dark count rates and timing resolution of 15–20 ps for a single photon detection. As such, these photosensors are very well suited for Ring Imaging CHerenkov (RICH) detectors that can additionally provide high resolution timing capability, especially in a configuration where a detected charged particle passes through the sensor window, which produces a localized flash containing a few dozens of Cherenkov photons in it.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A PIPS + SrI 2 (Eu) detector for atmospheric radioxenon monitoring

The PIPS–SrI 2 (Eu) is a prototype atmospheric radioxenon detection system designed at Oregon State University in support of international efforts towards monitoring clandestine nuclear weapon testing activities. This detector aims to address some shortcomings found in currently deployed beta–gamma atmospheric radioxenon detection systems, such as lackluster energy resolution and memory effect, by employing modern detection materials and readout. The system uses a PIPSBox, a silicon-based gas cell, for electron detection, and a pair of ultrabright, D-shaped SrI 2 (Eu) scintillators coupled to silicon photomultipliers for photon detection. A custom eight-channel digital pulse processor equipped with a field programmable gate-array (FPGA) identifies electron–photon coincidences between the volumes in near real-time. Gas samples of the four radioxenon isotopes of interest were independently measured with the PIPS–SrI 2 (Eu) detection system to determine energy resolution and efficiency. Application of FPGA-based coincidence discrimination in near real-time reduced the ambient background count rate by 95.85 ± 0.04%. Using parameters from the Xenon International gas processing unit and assuming a blank sample and zero memory effect the minimum detectable concentrations (MDCs) for the isotopes were calculated to be 0.12 ± 0.03, 0.27 ± 0.05, 0.15 ± 0.02, and 1.00 ± 0.08 mBq/m 3 air for 131m Xe, 133 Xe, 133m Xe, and 135 Xe, respectively. These MDC estimates compare well with other radioxenon detection systems employed in the International Monitoring System (IMS) and indicate that the PIPS–SrI 2 (Eu) is in compliance with the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO) sensitivity requirement of ≤ 1 mBq/m 3 for 133 Xe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel integrated time-resolved array avalanche photodiode detection system for nuclear resonant scattering measurements

Here, the nuclear resonant scattering (NRS) experiment requires photon-counting detectors with high time resolution, short dead time, large dynamic range, low noise, and large detection area. An 8-channel avalanche photodiode (APD) array detector system with high integrity, flexibility, and reliability has been developed to adapt to the demands of NRS experiments. The detector system mainly consists of four key parts: (i) an array-APD sensor, (ii) 8-channel integrated fast preamplifiers, (iii) the time-to-digital converter readout electronics, and (iv) a data acquisition system and EPICS support software. Remarkably, the system exhibits a time resolution of better than 500 ps and has a sufficiently low noise level, allowing for the lowest detection energy threshold of 4 keV. The performance of the new array-APD system as well as its real application in nuclear forward scattering (NFS) and nuclear resonant inelastic x-ray scattering (NRIXS) experiments was tested in two synchrotron facilities. With the new system, the NFS signal very close to the prompt electronic scattering signal can be extracted. Thanks to the customized EPICS-areaDetector-based control software, NRIXS spectra can be readily measured with time and energy information of the NRIXS signal stored in the raw data, which is promising for developing NRIXS data analysis in the time domain. The array-APD detector can be deployed for nuclear resonant scattering experiments at various synchrotron radiation facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evolution of Bonding and Magnetism via Changes in Valence Electron Count in CuFe 2– x Co x Ge 2

A series of solid solutions, CuFe 2–x Co x Ge 2 (x = 0, 0.2, 0.4, 0.8, and 1.0), have been synthesized by arc-melting and characterized by powder X-ray and neutron diffraction, magnetic measurements, Mössbauer spectroscopy, and electronic band structure calculations. All compounds crystallize in the CuFe 2 Ge 2 structure type, which can be considered as a three-dimensional framework built of fused MGe6 octahedra and MGe 5 trigonal bipyramids (M = Fe and Co), with channels filled by rows of Cu atoms. As the Co content (x) increases, the unit cell volume decreases in an anisotropic fashion: the b and c lattice parameters decrease while the a parameter increases. The changes in all the parameters are nearly linear, thus following Vegard’s law. CuFe 2 Ge 2 exhibits two successive antiferromagnetic (AFM) orderings, corresponding to the formation of a commensurate AFM structure, followed by an incommensurate AFM structure observed at lower temperatures. Additionally, as the Co content increases, the AFM ordering temperature (TN) gradually decreases, and only one AFM transition is observed for x ≥ 0.2. The magnetic behavior of unsubstituted CuFe 2 Ge 2 was found to be sensitive to the preparation method. The temperature-dependent zero-field 57 Fe Mössbauer spectra reveal two hyperfine split components that evolve in agreement with the two consecutive AFM orderings observed in magnetic measurements. In contrast, the field-dependent spectra obtained for fields ≥ 2 T reveal a parallel arrangement of the moments associated with the two crystallographically unique metal sites. Electronic band structure calculations and chemical bonding analysis reveal a mix of strong M–M antibonding and non-bonding states at the Fermi level, in support of the overall AFM ordering observed in zero field. The substitution of Co for Fe reduces the population of the M–M antibonding states and the overall density of states at the Fermi level, thus suppressing the T N value.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancing the sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment to low energy signals

Two-phase xenon detectors, such as that at the core of the forthcoming LZ dark matter experiment, use photomultiplier tubes to sense the primary (S1) and secondary (S2) scintillation signals resulting from particle interactions in their liquid xenon target. This paper describes a simulation study exploring two techniques to lower the energy threshold of LZ to gain sensitivity to low-mass dark matter and astrophysical neutrinos, which will be applicable to other liquid xenon detectors. The energy threshold is determined by the number of detected S1 photons; typically, these must be recorded in three or more photomultiplier channels to avoid dark count coincidences that mimic real signals. To lower this threshold: a) we take advantage of the double photoelectron emission effect, whereby a single vacuum ultraviolet photon has a $\sim20\%$ probability of ejecting two photoelectrons from a photomultiplier tube photocathode; and b) we drop the requirement of an S1 signal altogether, and use only the ionization signal, which can be detected more efficiently. For both techniques we develop signal and background models for the nominal exposure, and explore accompanying systematic effects, including the dependence on the free electron lifetime in the liquid xenon. When incorporating double photoelectron signals, we predict a factor of $\sim 4$ sensitivity improvement to the dark matter-nucleon scattering cross-section at $2.5$ GeV/c$^2$, and a factor of $\sim1.6$ increase in the solar $^8$B neutrino detection rate. Dropping the S1 requirement may allow sensitivity gains of two orders of magnitude in both cases. Finally, we apply these techniques to even lower masses by taking into account the atomic Migdal effect; this could lower the dark matter particle mass threshold to $80$ MeV/c$^2$.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancing the sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment to low energy signals

Two-phase xenon detectors, such as that at the core of the forthcoming LZ dark matter experiment, use photomultiplier tubes to sense the primary (S1) and secondary (S2) scintillation signals resulting from particle interactions in their liquid xenon target. This paper describes a simulation study exploring two techniques to lower the energy threshold of LZ to gain sensitivity to low-mass dark matter and astrophysical neutrinos, which will be applicable to other liquid xenon detectors. The energy threshold is determined by the number of detected S1 photons; typically, these must be recorded in three or more photomultiplier channels to avoid dark count coincidences that mimic real signals. To lower this threshold: a) we take advantage of the double photoelectron emission effect, whereby a single vacuum ultraviolet photon has a $\sim20\%$ probability of ejecting two photoelectrons from a photomultiplier tube photocathode; and b) we drop the requirement of an S1 signal altogether, and use only the ionization signal, which can be detected more efficiently. For both techniques we develop signal and background models for the nominal exposure, and explore accompanying systematic effects, including the dependence on the free electron lifetime in the liquid xenon. When incorporating double photoelectron signals, we predict a factor of $\sim 4$ sensitivity improvement to the dark matter-nucleon scattering cross-section at $2.5$ GeV/c$^2$, and a factor of $\sim1.6$ increase in the solar $^8$B neutrino detection rate. Dropping the S1 requirement may allow sensitivity gains of two orders of magnitude in both cases. Finally, we apply these techniques to even lower masses by taking into account the atomic Migdal effect; this could lower the dark matter particle mass threshold to $80$ MeV/c$^2$.

Akerib, DS↗

LLNL International Working Group on Gamma Spectrometry - Preparation of IDB Dataset

The spectral information and associated metadata, including source information, detector setup, and shielding configuration is described in human readable, comma-separated text files (csv). Five csv files are associated with each material type and include the following information (where [Isotope] is U, Pu, and MOX): [Isotope]_measurement_metadata - Metadata of the measurement configuration, including material composition at time of acquisition (decay corrected from certificate date). Data that is unique to a measurement configuration e.g. detector geometry, source-detector distance, analyzer and other electronics used, attenuating materials are provided in this file. [Isotope]_spectrum_metadata - The information that is unique to the spectrum. This includes detector specifications (e.g. date of acquisition, number of channels, gain (keV/channel), energy range, real and live time, full width half-maximum (FWHM) of the 186 or 208 peak for uranium or plutonium measurements, respectively. [Isotope]_source_metadata - The source material used for the measurement, this includes the ratio and uncertainties of isotopes present and processing information of the material. In addition, the certificate information for the source material is listed. [Isotope]_spectrum_counts_metadata - The counts per channel for each spectrum. This data is linked via the UID.spectrum index to the measurement_metadata file. [Isotope]_spectrum_checksum_metadata The MD5 checksum for the original spectrum file. This data is linked via the UID.spectrum index to the measurement_metadata file. This information is provided to prevent duplication of entries in the database.

42 ENGINEERING↗

LLNL International Working Group on Gamma Spectrometry - Preparation of IDB Dataset [Slides]

The spectral information and associated metadata, including source information, detector setup, and shielding configuration is described in human readable, comma-separated text files (csv). Six csv files are associated with each material type and include the following information (where [Isotope] is U, Pu, and MOX): [Isotope]_measurement_metadata Metadata of the measurement configuration, including material composition at time of acquisition (decay corrected from certificate date). Data that is unique to a measurement configuration e.g. detector geometry, source-detector distance, analyzer and other electronics used, attenuating materials are provided in this file. [Isotope]_spectrum_metadata The information that is unique to the spectrum. This includes detector specifications (e.g. date of acquisition, number of channels, gain (keV/channel), energy range, real and live time, full width half-maximum (FWHM) of the 186 or 208 peak for uranium or plutonium measurements, respectively. [Isotope]_source_metadata The source material used for the measurement, this includes the ratio and uncertainties of isotopes present and processing information of the material. In addition, the certificate information for the source material is listed. [Isotope]_spectrum_counts_metadata The counts per channel for each spectrum. This data is linked via the UID.spectrum index to the measurement_metadata file. [Isotope]_spectrum_checksum_metadata The MD5 checksum for the original spectrum file. This data is linked via the UID.spectrum index to the measurement_metadata file. This information is provided to prevent duplication of entries in the database. [Isotope]_provenance Details on the csv data provider, including laboratory and contract information.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Improving MicroBooNE's Inclusive Single-Photon Search with Low-Energy Hadronic Identification

This analysis aims to further investigate MicroBooNE’s inclusive single-photon search results, which reported a 2.2$\sigma$ excess below 600 MeV in shower energy for events with no reconstructed protons using roughly half of MicroBooNE's dataset. Taken together with MiniBooNE’s long-standing low-energy excess and MicroBooNE’s recent electron-like search results showing no observable excess with respect to Standard Model predictions, this result provides strong impetus for expanded exploration of the single-photon channel in Fermilab’s short-baseline liquid-argon time projection chamber (LArTPC) experiments. By identifying and classifying isolated MeV-scale energy depositions, or blips, in the vicinity of single-photon events selected by the Wire-Cell reconstruction framework, we establish a more comprehensive labeling scheme for nearby hadronic content. In particular, blips found backwards along the shower axis indicate the presence of previously-unidentified final-state protons, while elevated blip counts at wide angles signal the presence of final-state neutrons. By applying this new technique to its full dataset, MicroBooNE will perform a purer and higher-statistics test of the truly isolated nature of its modest photon-like excess, furthering its hunt for the presence of unexpected new physics beyond the Standard Model.

Andrade Aldana, Diego [Los Alamos; IIT, Chicago (m↗

Multi-amplifier Sensing Charge-coupled Devices for Next Generation Spectroscopy

We present characterization results and performance of a prototype Multiple-Amplifier Sensing (MAS) silicon charge-coupled device (CCD) sensor with 16 channels potentially suitable for faint object astronomical spectroscopy and low-signal, photon-limited imaging. The MAS CCD is designed to reach sub-electron readout noise by repeatedly measuring charge through a line of amplifiers during the serial transfer shifts. Using synchronized readout electronics based on the Dark Energy Spectroscopic Instrument CCD controller, we report a read noise of 1.03 e$^{−}$ rms pix$^{−1}$ at a speed of 26 μs pix$^{−1}$ with a single-sample readout scheme where charge in a pixel is measured only once for each output stage. At these operating parameters, we find the amplifier-to-amplifier charge transfer efficiency (ACTE) to be >0.9995 at low counts for all amplifiers but one for which the ACTE is 0.997. This charge transfer efficiency falls above 50,000 electrons for the read-noise optimized voltage configuration we chose for the serial clocks and gates. The amplifier linearity across a broad dynamic range from ∼300 to 35,000 e$^{−}$ was also measured to be ±2.5%. We describe key operating parameters to optimize on these characteristics and describe the specific applications for which the MAS CCD may be a suitable detector candidate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electromagnetic production of kaons on the nucleon

Studies of the electromagnetic production of strange quarks started in the 1950s as something of a curiosity that puzzled experimentalists and theorists alike. Eventually, a nascent understanding of these processes began to take shape through the first pioneering experiments dedicated to explore photo- and electroproduction that were carried out in the period from the 1950s to the 1980s. As the datasets increased, concomitant advances in theoretical models were realized. However, these initial studies also made clear that more precise data was essential to continue to move forward. A paradigm shift occurred in the 1990s with the development of second-generation facilities at ELSA, MAMI, SPring-8, and JLab. High-intensity, high duty-factor accelerators, coupled with novel detector systems and advances in computing and readout electronics, brought nuclear physics experiments forward by orders of magnitude in counting statistics compared to the first-generation efforts. This was an utter boon to strangeness physics investigations, and to date, more than 50 dedicated experiments in kaon photo- and electroproduction have been completed at facilities around the world, leading to a host of experimental observables that have enabled significant advances in the exploration of strongly interacting systems that decay via $s\bar{s}$ quark pair creation. These data have proven to be an essential complementary pathway to study the spectrum and structure of the excited states of the nucleon, and the search for missing and exotic baryon configurations. As well, investigations in these channels are requisite for exploring hypernuclear production as a probe of the $YN$ interaction and for studies of the electromagnetic form factors of strange mesons. This review was designed to provide the first-ever in-depth overview of both the experimental and theoretical progress in the field of the electromagnetic production of strangeness. This work looks back over 70 years of past developments, discusses ongoing work and near-term plans, and details future possibilities being considered for third-generation facilities. Extensive lists of the available datasets and theoretical models are provided, together with a comprehensive supporting bibliography of the field. Throughout this work, the primary impacts of these explorations are highlighted, along with connections to a wide range of related phenomenological applications. An important goal of this review is to provide a complete, (reasonably) self-contained guide into this field prepared at a level that is relevant for both new and seasoned scientists, whether experimentalists, phenomenologists, or theorists, to better understand what has been accomplished by so many dedicated folks-each building on what has come before-and to appreciate the exciting future potential for continued studies in this area.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Astronomical Spectroscopy with Skipper CCDs: First Results from a Skipper CCD Focal Plane Prototype at SIFS

We present the first on-sky results from an ultra-low-readout-noise Skipper CCD focal plane prototype for the SOAR Integral Field Spectrograph (SIFS). The Skipper CCD focal plane consists of four 6k $\times$ 1k, 15 $\mu$m pixel, fully-depleted, $p$-channel devices that have been thinned to $\sim$250 $\mu$m, backside processed, and treated with an anti-reflective coating. These Skipper CCDs were configured for astronomical spectroscopy, i.e., a single-sample readout noise $< 4.3$\,e$^-$\,rms/pixel, the ability to achieve multi-sample readout noise $\ll 1\,$e$^-$\,rms/pix, full-well capacities $\sim$40,000--65,000 e$^-$, low dark current and charge transfer inefficiency ($\sim 2$ $\times$ $10^{-4}$ e$^-$/pixel/s and 3.44 $\times$ $10^{-7}$, respectively), and an absolute quantum efficiency of $\gtrsim 80\%$ between 450\,nm and 980\,nm ($\gtrsim 90\%$ between 600\,nm and 900\,nm). We optimize the readout sequence timing to achieve sub-electron noise ($\sim 0.5$\,e$^-$\,rms/pix) and photon-counting ($\sim 0.22$\,e$^-$\,rms/pix) readout noise over an area of 2k $\times$ 4k and 110 $\times$ 4k pixels, respectively in a readout time of $\lesssim 17$min. We observed two Lyman-$\alpha$ emitting quasars (HB89\,1159$+$123 and QSO\,J1621$–$0042) at redshift $z \sim 3.5$, two moderate redshift galaxy clusters (CL\,J1001$+$0220 and SPT-CL\,J2040$-$4451), an emission line galaxy at $z = 0.3239$, a candidate member star of the Bo\"{o}tes~II ultra-faint dwarf galaxy, and five CALSPEC spectrophotometric standard stars (HD074000, HD60753, HD106252, HD101452, HD200654). We present charge-quantized, photon-counting observation of the quasar HB89\,1159$+$123 and show the detector sensitivity increase for faint spectral features. We demonstrate signal-to-noise performance improvement for SIFS for observations in the low-background, readout-noise-dominated regime. We outline preliminary scientific studies that will leverage the SIFS-Skipper CCD data to derive new cosmological measurements in the context of dark matter and galaxy evolution.

79 ASTRONOMY AND ASTROPHYSICS↗