Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic channel count”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Raman-Augmented Stratospheric-Ozone Lidar

Differential-absorption lidar (DIAL) system measures concentration of ozone in stratosphere augmented with subsystem measuring Raman scattering from nitrogen. One of number of DIAL systems used in long-term monitoring of stratospheric ozone. Raman scattering from nitrogen provides data to correct for effects of aerosols. Channels at wavelengths of 332 and 385 nm added to DIAL receiver to measure Raman backscattering from nitrogen molecules in stratosphere. Data-acquisition electronics sample photon counts at a rate of 250 MHz.

Mcdermid, I. Stuart↗

Performance characteristics of high-conductivity channel electron multipliers

The paper describes a new type of continuous channel multiplier (CEM) fabricated from a low-resistance glass to produce a high-conductivity channel section and thereby obtain a high count-rate capability. The flat-cone cathode configuration of the CEM is specifically designed for the detection of astigmatic exit images from grazing-incidence spectrometers at the optimum angle of illumination for high detection efficiencies at XUV wavelengths. Typical operating voltages are in the range of 2500-2900 V with stable counting plateau slopes in the range 3-6% per 100-V increment. The modal gain at 2800 V was typically in the range (50-80) million. The modal gain falls off at count rates in excess of about 20,000 per sec. The detection efficiency remains essentially constant to count rates in excess of 2 million per sec. Higher detection efficiencies (better than 20%) are obtained by coating the CEM with MgF2. In life tests of coated CEMs, no measurable change in detection efficiency was measured to a total accumulated signal of 2 times 10 to the 11th power counts.

Timothy, J. G.↗

Curved-channel microchannel array plates

The microchannel array plate (MCP) is a photoelectric detector with an imaging capability comparable to that of a photographic plate. Recently MCPs in which the channels are curved to inhibit ion feedback have become available. These devices represent a major advance in MCP technology, since a single curved-channel MCP can be operated stably at high gain in the pulse-counting mode without any of the problems of stability of response or short lifetime reported for 'chevron' MCP detectors. Attention is given to the mode of operation of channel electron multipliers (CEM) and MCP, curved-channel MCP, test procedures, and performance characteristics. The accumulated test data show that the fundamental operating characteristics of the curved-channel MCP are directly related to those for the CEM.

Timothy, J. G.↗

Hard-X-Ray/Soft-Gamma-Ray Imaging Sensor Assembly for Astronomy

An improved sensor assembly has been developed for astronomical imaging at photon energies ranging from 1 to 100 keV. The assembly includes a thallium-doped cesium iodide scintillator divided into pixels and coupled to an array of high-gain avalanche photodiodes (APDs). Optionally, the array of APDs can be operated without the scintillator to detect photons at energies below 15 keV. The array of APDs is connected to compact electronic readout circuitry that includes, among other things, 64 independent channels for detection of photons in various energy ranges, up to a maximum energy of 100 keV, at a count rate up to 3 kHz. The readout signals are digitized and processed by imaging software that performs "on-the-fly" analysis. The sensor assembly has been integrated into an imaging spectrometer, along with a pair of coded apertures (Fresnel zone plates) that are used in conjunction with the pixel layout to implement a shadow-masking technique to obtain relatively high spatial resolution without having to use extremely small pixels. Angular resolutions of about 20 arc-seconds have been measured. Thus, for example, the imaging spectrometer can be used to (1) determine both the energy spectrum of a distant x-ray source and the angular deviation of the source from the nominal line of sight of an x-ray telescope in which the spectrometer is mounted or (2) study the spatial and temporal development of solar flares, repeating - ray bursters, and other phenomena that emit transient radiation in the hard-x-ray/soft- -ray region of the electromagnetic spectrum.

Myers, Richard A.↗

Progress in Interferometric Rayleigh Scattering to Measure Fluctuations Spectra of Velocity and Temperature in High Speed Flows

A new, spectrally-resolved, Rayleigh scattering setup at NASA Ames is further developed to measure fluctuations in velocity and temperature. Using a combination of a continuous-wave laser, a stabilized Fabry-Perot interferometer (FPI), an EMCCD camera, and a photo-multiplier tube, the setup was demonstrated to provide fairly accurate measurements of time-averaged velocity, temperature, density and spectrum of density fluctuations in a high-speed free jet (Panda & White, 2018). This paper describes further progress in fast measurement of the Rayleigh-Brillouin spectrum via a 16-anode linear-array of photo-multiplier tube and a multi-channel, photo-electron counter. Rayleigh scattered light from a 0.4mm long probe volume was directly imaged through the FPI and was imaged on the linear array. Synchronous photo-electron counting over a series of short, contiguous gates provided time-evolution of the fringes at a 10 kHz sampling rate. Sample spectra collected from a Mach 0.98 jet show spectral content floating on high noise-floor. Efforts to collect longer time series of data and different schemes of extracting velocity and temperature information are now in progress.

Panda, J.↗

Maturing CCD Photon-Counting Technology for Space Flight

This paper discusses charge blooming and starlight saturation - two potential technical problems - when using an Electron Multiplying Charge Coupled Device (EMCCD) type detector in a high-contrast instrument for imaging exoplanets. These problems especially affect an interferometric type coronagraph - coronagraphs that do not use a mask to physically block starlight in the science channel of the instrument. These problems are presented using images taken with a commercial Princeton Instrument EMCCD camera in the Goddard Space Flight Center's (GSFC), Interferometric Coronagraph facility. In addition, this paper discusses techniques to overcome such problems. This paper also discusses the development and architecture of a Field Programmable Gate Array and Digital-to-Analog Converter based shaped clock controller for a photon-counting EMCCD camera. The discussion contained here will inform high-contrast imaging groups in their work with EMCCD detectors.

Mallik, Udayan↗

Intelligent Systems for Self-Healing Electronics

For long duration missions it is imperative to be able to monitor and record critical information. The data acquisition systems used must therefore be fault tolerant. This usually meant having redundant copies of critical channels. Since each channel usually consists of various components, the parts count, cost, weight and complexity of the system could be very high. The Advanced Data Acquisition System (ADAS) has been developed as a proof of concept. The purpose was to demonstrate an architecture where individual spare parts can replace defective ones to repair a channel. By so doing entire channels do not need replication. This reduces the need of total redundancy and reduces the parts count. This has the added feature that in addition to spare parts, good components of a failed channel can be used as spares in another channel. In addition to reducing parts count and cost, this configuration, with an intelligent decision maker, can improve the reliability of the overall system. Another unique feature of ADAS is that it uses reconfigurable analog filters. These components can be programmed, by the smart system to meet the specific needs of the part they are to replace. This way one part can serve as spare for many different components. The hardware was built and now serves as a platform for developing intelligent algorithms. Another related project was a wireless data acquisition system. I was invited to participate in the meetings and issue suggestions. A brief description of this system will also be included.

Latino, Carl D.↗

Soft X-ray photoemission with the SSX-100 spectrometer

Photoemission and SEXAFS experiments were conducted using a double crystal monochromator at the Stanford Synchrotron Radiation Laboratory. Photoelectrons were detected using a Surface Science Laboratories SSX-100 electron analyzer, which employs a magnetic/electrostatic lens, hemispherical geometry, and a two-dimensional position-sensitive detector. In the kinetic energy range of interest (1000-2000 eV), a significant improvement in count rate was observed over a single channel cylindrical mirror analyzer system. Ten second scans of the KLL silicon Auger peak manifold were recorded at a large number of photon energies for subsequent determination of SEXAFS spectra.

Hecht, M. H.↗

Improved Detection System Description and New Method for Accurate Calibration of Micro-Channel Plate Based Instruments and Its Use in the Fast Plasma Investigation on NASA's Magnetospheric MultiScale Mission

The Fast Plasma Investigation (FPI) on NASAs Magnetospheric MultiScale (MMS) mission employs 16 Dual Electron Spectrometers (DESs) and 16 Dual Ion Spectrometers (DISs) with 4 of each type on each of 4 spacecraft to enable fast (30 ms for electrons; 150 ms for ions) and spatially differentiated measurements of the full 3D particle velocity distributions. This approach presents a new and challenging aspect to the calibration and operation of these instruments on ground and in flight. The response uniformity, the reliability of their calibration and the approach to handling any temporal evolution of these calibrated characteristics all assume enhanced importance in this application, where we attempt to understand the meaning of particle distributions within the ion and electron diffusion regions of magnetically reconnecting plasmas. Traditionally, the micro-channel plate (MCP) based detection systems for electrostatic particle spectrometers have been calibrated using the plateau curve technique. In this, a fixed detection threshold is set. The detection system count rate is then measured as a function of MCP voltage to determine the MCP voltage that ensures the count rate has reached a constant value independent of further variation in the MCP voltage. This is achieved when most of the MCP pulse height distribution (PHD) is located at higher values (larger pulses) than the detection system discrimination threshold. This method is adequate in single-channel detection systems and in multi-channel detection systems with very low crosstalk between channels. However, in dense multi-channel systems, it can be inadequate. Furthermore, it fails to fully describe the behavior of the detection system and individually characterize each of its fundamental parameters. To improve this situation, we have developed a detailed phenomenological description of the detection system, its behavior and its signal, crosstalk and noise sources. Based on this, we have devised a new detection system calibration method that enables accurate and repeatable measurement and calibration of MCP gain, MCP efficiency, signal loss due to variation in gain and efficiency, crosstalk from effects both above and below the MCP, noise margin, and stability margin in one single measurement. More precise calibration is highly desirable as the instruments will produce higher quality raw data that will require less post-acquisition data correction using results from in-flight pitch angle distribution measurements and ground calibration measurements. The detection system description and the fundamental concepts of this new calibration method, named threshold scan, will be presented. It will be shown how to derive all the individual detection system parameters and how to choose the optimum detection system operating point. This new method has been successfully applied to achieve a highly accurate calibration of the DESs and DISs of the MMS mission. The practical application of the method will be presented together with the achieved calibration results and their significance. Finally, it will be shown that, with further detailed modeling, this method can be extended for use in flight to achieve and maintain a highly accurate detection system calibration across a large number of instruments during the mission.

detection system↗

Ultra-Compact Motor Controller

This invention is an electronically commutated brushless motor controller that incorporates Hall-array sensing in a small, 42-gram package that provides 4096 absolute counts per motor revolution position sensing. The unit is the size of a miniature hockey puck, and is a 44-pin male connector that provides many I/O channels, including CANbus, RS-232 communications, general-purpose analog and digital I/O (GPIO), analog and digital Hall inputs, DC power input (18-90 VDC, 0-l0 A), three-phase motor outputs, and a strain gauge amplifier. This controller replaces air cooling with conduction cooling via a high-thermal-conductivity epoxy casting. A secondary advantage of the relatively good heat conductivity that comes with ultra-small size is that temperature differences within the controller become smaller, so that it is easier to measure the hottest temperature in the controller with fewer temperature sensors, or even one temperature sensor. Another size-sensitive design feature is in the approach to electrical noise immunity. At a very small size, where conduction paths are much shorter than in conventional designs, the ground becomes essentially isopotential, and so certain (space-consuming) electrical noise control components become unnecessary, which helps make small size possible. One winding-current sensor, applied to all of the windings in fast sequence, is smaller and wastes less power than the two or more sensors conventionally used to sense and control winding currents. An unexpected benefit of using only one current sensor is that it actually improves the precision of current control by using the "same" sensors to read each of the three phases. Folding the encoder directly into the controller electronics eliminates a great deal of redundant electronics, packaging, connectors, and hook-up wiring. The reduction of wires and connectors subtracts substantial bulk and eliminates their role in behaving as EMI (electro-magnetic interference) antennas. A shared knowledge by each motor controller of the state of all the motors in the system at 500 Hz also allows parallel processing of higher-level kinematic matrix calculations.

Townsend, William T.↗

Cloud screening Coastal Zone Color Scanner images using channel 5

Clouds are removed from Coastal Zone Color Scanner (CZCS) data using channel 5. Instrumentation problems require pre-processing of channel 5 before an intelligent cloud-screening algorithm can be used. For example, at intervals of about 16 lines, the sensor records anomalously low radiances. Moreover, the calibration equation yields negative radiances when the sensor records zero counts, and pixels corrupted by electronic overshoot must also be excluded. The remaining pixels may then be used in conjunction with the procedure of Simpson and Humphrey to determine the CZCS cloud mask. These results plus in situ observations of phytoplankton pigment concentration show that pre-processing and proper cloud-screening of CZCS data are necessary for accurate satellite-derived pigment concentrations. This is especially true in the coastal margins, where pigment content is high and image distortion associated with electronic overshoot is also present. The pre-processing algorithm is critical to obtaining accurate global estimates of pigment from spacecraft data.

Eckstein, B. A.↗

Ion Storage Tests with the High Performance Antimatter Trap (HiPAT)

The NASA/Marshall Space Flight Centers (NASA/MSFC) Propulsion Research Center (PRC) is evaluating an antiproton storage system, referred to as the High Performance Antiproton Trap (HiPAT). This interest stems from the sheer energy represented by matter/antimatter annihilation process with has an energy density approximately 10 order of magnitude above that of chemical propellants. In other terms, one gram of antiprotons contains the equivalent energy of approximately 23 space shuttle external tanks or ET's (each ET contains roughly 740,000 kgs of fuel and oxidizer). This incredible source of stored energy, if harnessed, would be an enabling technology for deep space mission where both spacecraft weight and propulsion performance are key to satisfying aggressive mission requirements. The HiPAT hardware consists of a 4 Tesla superconductor system, an ultra high vacuum test section (vacuum approaching 10(exp -12) torr), and a high voltage confinement electrode system (up to 20 kvolts operation). The current laboratory layout is illustrated. The HiPAT designed objectives included storage of up to 1 trillion antiprotons with corresponding lifetimes approaching 18 days. To date, testing has centered on the storage of positive hydrogen ions produced in situ by a stream of high-energy electrons that passes through the trapping region. However, due to space charge issues and electron beam compression as it passes through the HiPAT central field, current ion production is limited to less then 50,000 ions. Ion lifetime was determined by counting particle populations at the end of various storage time intervals. Particle detection was accomplished by destructively expelling the ions against a micro-channel plate located just outside the traps magnetic field. The effect of radio frequency (RF) stabilization on the lifetime of trapped particles was also examined. This technique, referred to as a rotating wall, made use of a segmented electrode located near the center of the trap on which various phases of a particular frequency were applied. Various experiments were performed illustrating the ability of an RF drive to both prolong and reduced the lifetimes of various ion species depending on the selected frequency. HiPAT is now being reconfigured for testing with an ion source that will provide both positive and negative hydrogen ions from an external source. This ion system shall provide higher fill capacity (order of million of ions per shot), stacking of multiple shots, and injection schemes typical of a realistic antiproton delivery system.

Martin, James J.↗

Ultra-Compact Motor Controller

This invention is an electronically commutated brushless motor contro ller that incorporates Hall-array sensing in a small, 42-gram packag e that provides 4096 absolute counts per motor revolution position s ensing. The unit is the size of a miniature hockey puck, and is a 44 -pin male connector that provides many I/O channels, including CANbus , RS-232 communications, general-purpose analog and digital I/O (GPI O), analog and digital Hall inputs, DC power input (18-90 VDC, 0-l0 A), three-phase motor outputs, and a strain gauge amplifier.

Townsend, William T.↗

Maturing Electron Multiplying Charge Coupled Device Photon-Counting with Variable Multiplication Gain Imaging for a Coronagraphic Instrument

This is an introduction to a US Government Program that conducted high-contrast imaging experiments with an Electron Multiplying Charge Coupled Device (EMCCD) in an interferometric coronagraph. This report will introduce the concepts of “Charge Blooming” and “Starlight Saturation” in the context of high-contrast astronomical imaging. These phenomena adversely affect the performance of high-contrast photon-counting instruments that do not use a mask to physically block starlight in the science channel of the coronagraph. The problems will be presented with the help of images taken with a commercial EMCCD camera in the Visible Nulling Coronagraph at the Goddard Space Flight Center (GSFC). A new clocking scheme for EMCCDs – Variable Multiplication Gain Clocking – will be proposed as a means for suppressing horizontal blooming and starlight saturation in an astronomical camera. This opening report from the program will conclude with an introduction to a new controller for high-contrast imaging with EMCCDs in coronagraphs. This controller is being designed to allow a single frame from an EMCCD to be scanned in multiple modes – photon counting and digitization – to enable direct imaging of an exo-planet and wavefront control of a coronagraph, simultaneously.

Udayan Mallik↗

End-to-end test of the electron-proton spectrometer

A series of end-to-end tests were performed to demonstrate the proper functioning of the complete Electron-Proton Spectrometer (EPS). The purpose of the tests was to provide experimental verification of the design and to provide a complete functional performance check of the instrument from the excitation of the sensors to and including the data processor and equipment test set. Each of the channels of the EPS was exposed to a calibrated beam of energetic particles, and counts were accumulated for a predetermined period of time for each of several energies. The counts were related to the known flux of particles to give a monodirectional response function for each channel. The measured response function of the test unit was compared to the response function determined for the calibration sensors from the data taken from the calibration program.

Cash, B. L.↗

Upper limits for X-ray and energetic neutral particle emission from Jupiter - Voyager-1 results

The X-ray sensitivity of the low energy proton channels in the Low Energy Charged Particle (LECP) experiment and its directional measurements determined whether X-rays from Jupiter can be recognized as additional flux above background as Voyager 1 approached the planet. Between about 230 and about 100 R(J), a statistically significant count rate was detected interpreted as X-rays and/or neutral particles. Such an X-ray flux leads to estimates of precipitating electrons over the Jovian polar caps which are 200 times larger than over observed electron fluxes in the Io plasma torus.

Kirsch, E.↗

Channel electron multiplier compatibility with Viton and Apiezon-L vacuum grease

Clean Viton and Viton coated with Apiezon-L vacuum grease were tested for their noncontaminating compatibility with channel electron multipliers (CEMs). The test setup and procedure were the same as those used previously in conjunction with CEM compatibility tests of certain epoxies, solder, and fluorocarbon polymer materials useful for construction of spaceflight sensors. While some CEM gain degradation was noted during exposure to Viton and Apiezon-L, the present tests indicate that, at least over instrument lifetimes of about 2 x 10 to the 12th counts, these materials should be suitable for (1) preflight space sensor testing systems, (2) hermetic seals for CEM-based space sensors, and (3) terrestrial CEM-based instrumentation.

Mccomas, D. J.↗

Hard X-ray and radio emission at the onset of great solar flares

A study of the onset phase of ten great hard X-ray bursts is presented. It is shown from hard X-ray and radio observations in different wavelength ranges that the energization of the electrons proceeds on a global time-scale for some tens of seconds. In nine of the bursts, two phases of emission can be distinguished during the onset phase: the preflash phase (during which emission up to an energy limit ranging from some tens of keV to 200 keV is observed) followed ten to some tens of seconds later by the flash phase (where the count rate in all detector channels rises simultaneously to within some seconds). For two of the events, strong gamma-ray line emission is observed and is shown to start close to the onset of the flash phase.

Klein, K.-L.↗