Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron tubes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Co-Extrusion of Dissimilar Aluminum Alloys via Shear-Assisted Processing and Extrusion

Bimetallic tubes are used when a component requires more than one performance requirement, for instance, strength/creep resistance and oxidation/corrosion resistance. Shear-assisted processing and extrusion (ShAPE) can be used to fabricate extrudates that are comparable or superior in performance relative to conventionally manufactured extrudates. For the first time, ShAPE has been successfully employed in producing bimetallic Al tubing consisting of 6061 and 7075 Al alloys. Both light and electron microscopy techniques were used to investigate the integrity of the tubes, especially the interface between the core and cladding of the bimetallic tubes. Void-free bimetallic tubes were produced using ShAPE. Quantification of tube integrity was carried out with tensile testing under as-extruded and post-aged conditions. All the bimetallic tubes in the as-extruded samples exhibited uniform elongation above 5% with good tensile strength. Key insights such as material flow during bimetallic tube extrusion were obtained from the characterization of remnant billet and simulation results from a smoothed particle hydrodynamics model.

36 MATERIALS SCIENCE↗

Design, assembly and operation of a Cosmic Ray Tagger based on scintillators and SiPMs

The Mu2e experiment at Fermilab aims to search for the SM forbidden μ – → e – conversion in Al muonic atoms. The signal signature consists of 104.96 MeV electrons, identified by a straw-tube tracker and a crystal calorimeter, made of two annular disks. Here, in order to calibrate the calorimeter disks with minimum ionizing particles (MIP) before the installation, we have realized a Cosmic Ray Tagger (CRT) at Laboratori Nazionali di Frascati (LNF) of INFN. The CRT consists of two planes of eight 2.5 x 1.5 x 160 cm 3 plastic scintillator (EJ-200) bars, coupled to SiPMs on both edges, so as to estimate longitudinal hit positions from time differences. 3D MIP tracking is achieved by reconstructing hit positions in the two planes, placed above and below the disks, and allows to calibrate the energy response, to align the time offsets, and to study the detector performances dependence along the crystals axis.

79 ASTRONOMY AND ASTROPHYSICS↗

Next-generation neutron detection using a 6 Li glass scintillator composite

Neutron detectors are crucial in fundamental science, nuclear security, safeguards, and civil applications. 3 He-filled gas proportional counters are the gold standard for thermal neutron detection, prized for their efficiency, neutron/gamma discrimination, and stability; however, the scarcity of 3 He has prompted the search for alternatives. Here, we introduce a neutron detector design based on a scintillating composite consisting of 6 Li glass scintillator particles dispersed in an organic matrix. A detector consisting of this scintillating composite, photomultiplier tubes (PMTs) for optical detection, and electronics for reading out the PMT signal in both pulse and current modes was prototyped and characterized using various neutron and gamma sources. The prototype achieves a measured intrinsic detection efficiency of 6.70 ± 0.01%, a die-away time of 10.3 ± 0.1 μs, a negligible gamma misidentification probability, and response linearity up to at least 3.7 × 10 6 incident neutrons/s established via a cross-calibration technique. This detector holds the potential to outperform traditional 3 He-gas-based neutron detection systems, offering a viable alternative amidst the ongoing 3 He shortage and promising advancements in neutron detection technology.

47 OTHER INSTRUMENTATION↗

Final Report on the Phase II Physics Proposal for T-1063: The Accelerator Neutrino Neutron Interaction Experiment (ANNIE)

The goal of ANNIE is to make the first detailed measurement of the number of neutrons produced by neutrinos interacting with nuclei. This measurement is important for understanding the results of previous and planned neutrino experiments, as neutrons carry away energy from the neutrino interactions that must be accounted for in determining the energy and neutrino type. This effort is also focused on using a new photodetector technology and key target material enhancements to enable advanced water-based neutrino detectors. The ANNIE detector has been installed in the Booster Neutrino Beam at Fermilab, which provides a pulsed source of neutrinos in the energy range of 300-1200 MeV, which is relevant for the next generation of neutrino experiments. In 2017-2018 measurements of the neutron background in this beam were made with a partially-instrumented ANNIE detector. These measurements guided our design of the upgraded detector now built. The upgrade has been realized by adding Large Area Picosecond Photodetectors (LAPPDs) for the first time, more conventional photomultiplier tubes (PMTs), as well as adding electronics channels to the existing data acquisition system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of a comprehensive first-principles-based framework for predicting the performance of future stellarators

This paper presents the validation of the GENE-KNOSOS-Tango framework for recovering both the steady-state plasma profiles in the considered radial domain and selected turbulence trends in a stellarator. This framework couples the gyrokinetic turbulence code GENE, the neoclassical transport code KNOSOS, and the transport solver Tango in a multi-timescale simulation feedback loop. Ion-scale kinetic-electron and electron-scale adiabatic-ion flux-tube simulations were performed to evolve the density and temperature profiles for four OP1.2b W7-X scenarios. The simulated density and temperature profiles showed good agreement with the experimental data using a reasonable set of boundary conditions. Equally important was the reproduction of observed trends for several turbulence properties, such as density fluctuations and turbulent heat diffusivities. Key effects were also touched upon, such as electron-scale turbulence and the neoclassical radial electric field shear. The validation of the GENE-KNOSOS-Tango framework enables credible predictions of physical phenomena in stellarators and reactor performance based on a given set of edge parameters.

Gyrokinetic simulations↗

Ni/NiO Reference Electrode Potential Measurements in Molten CaCl 2 –CaO

A direct oxide reduction (DOR) process is used to reduce PuO 2 to Pu metal via Ca metal. Molten CaCl 2 is commonly used as the electrolyte for this reaction. As the DOR reaction proceeds, CaO accumulates in the salt and must be measured in real-time to know when the reaction has gone to completion. Open circuit potential (OCP) was measured in this report between a reference electrode consisting of Ni/NiO contained in a MgO tube and a tungsten working electrode. Two methods of CaO additions were performed over several experiments, and both methods correlated to a 0.11 to 0.23 V decrease in OCP up to 14.4 wt% CaO. CaO concentrations were separately measured via sampling and acid-base titration. A plot of OCP versus concentration of CaO fits the Nernst equation with the CaO powder additions up to 5.2 wt% and also at the higher end of the CaO pellet concentration range. While the MgO tubes were observed to be structurally stable in the molten salt, scanning electron microscopy and energy dispersive X-ray spectroscopy showed that Mg in the tubes had been partially replaced with Ca.

36 MATERIALS SCIENCE↗

Effects of Proton Irradiation on GaN Vacuum Electron Nanodiodes

Gallium nitride (GaN)-based nanoscale vacuum electron devices, which offer advantages of both traditional vacuum tube operation and modern solid-state technology, are attractive for radiation-hard applications due to the inherent radiation hardness of vacuum electron devices and the high radiation tolerance of GaN. Here, we investigate the radiation hardness of top-down fabricated n-GaN nanoscale vacuum electron diodes (NVEDs) irradiated with 2.5-MeV protons (p) at various doses. We observe a slight decrease in forward current and a slight increase in reverse leakage current as a function of cumulative protons fluence due to a dopant compensation effect. The NVEDs overall show excellent radiation hardness with no major change in electrical characteristics up to a cumulative fluence of 5E14 p/cm 2 , which is significantly higher than the existing state-of-the-art radiation-hardened devices to our knowledge. In conclusion, the results show promise for a new class of GaN-based nanoscale vacuum electron devices for use in harsh radiation environments and space applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Overview of the New Beam Physics Research at the IOTA/FAST Facility

The Fermilab Accelerator Science and Technology (FAST) facility is dedicated to the exploration of novel concepts in accelerator and beam physics, and the development of a robust workforce, in order to enable and enhance next-generation particle accelerators. FAST comprises a high-brightness superconducting electron linac, and a storage ring, the Integrable Optics Test Accelerator (IOTA). Experiments in the most recent operational run include studies of nonlinear integrable lattices; tracking of single electrons; precise characterization of undulator radiation; studies with low-momentum-compaction lattices; and ultra-wide range beam diagnostics based on Photomultiplier tubes. In the linac, experiments on noise in intense electron bunches were conducted. The IOTA proton injector, currently being commissioned, will enable a diverse program on space-charge-dominated beams. Research areas include non-invasive beam profile monitoring for proton beams; beam dynamics with electron lenses; halo suppression, feedback systems, and electron cooling. In this presentation, we provide an overview of the recent results and highlight future plans together with opportunities for collaboration.

43 PARTICLE ACCELERATORS↗

Mu2e Tracker Electronics - Construction of a Straw Tracker

The Mu2e experiment, currently under construction at the Fermi National Accelerator Laboratory (FNAL) in Batavia, Illinois, is a particle physics experiment designed to detect Charged Lepton Flavor Violation (CLFV) via muon-to-electron conversion, a process beyond the Standard Model (BSM). One of the primary Mu2e detectors is the Straw Tracker, whose purpose is to measure the momentum of the electron, identify the signal, and reject background. The straw tubes are being read out by a total of 20,736 preamplifiers (preamps) within 36 planes that make up the Tracker. In this presentation, the installation of electronics into the Tracker, the implementation of anti-oscillation copper clips, and the process of installing fully constructed planes into the frame will be discussed in depth.

Lynch, Alec [UC, Berkeley]↗

Analysis of the elliptic integrable non-linear system in IOTA using tracking of a single electron

Integrable nonlinear lattices that can be realized in practical accelerators are of great interest, as they offer the potential to support high-intensity beams via Landau damping of collective instabilities. One such system, based on an elliptic potential, has been extensively studied at the IOTA storage ring at Fermilab. The analysis of strongly nonlinear dynamics with multi-particle bunches is challenging due to the rapid decoherence of kicked beams. IOTA has the capability to track single electrons using linear multi-anode photomultiplier tubes for simultaneously measuring transverse coordinates and arrival times of synchrotron-radiation pulses. This technology enables the full reconstruction of turn-by-turn positions and momenta in all three planes for a single particle. Using this apparatus, we measured the dependence of small-amplitude tunes on the strength of the nonlinear magnet, as well as tunes dependence on oscillations amplitudes.

Romanov, A. [Fermilab]↗

Analysis of the Elliptic Integrable Non-Linear System in IOTA Using Tracking of a Single Electron

Integrable nonlinear lattices that can be realized in practical accelerators are of great interest, as they offer the potential to support high-intensity beams via Landau damping of collective instabilities. One such system, based on an elliptic potential, has been extensively studied at the IOTA storage ring at Fermilab. The analysis of strongly nonlinear dynamics with multi-particle bunches is challenging due to the rapid decoherence of kicked beams. IOTA has the capability to track single electrons using linear multi-anode photomultiplier tubes for simultaneously measuring transverse coordinates and arrival times of synchrotron-radiation pulses. This technology enables the full reconstruction of turn-by-turn positions and momenta in all three planes for a single particle. Using this apparatus, we measured the dependence of small-amplitude tunes on the strength of the nonlinear magnet, as well as tunes dependence on oscillations amplitudes.

Romanov, Aleksandr Leonidovich [Fermilab] (ORCID:0↗

Measurement of the gas gain and understanding the gas flow in the Mu2e Tracker

The Mu2e experiment will search for the charged-lepton flavor violating (CLFV) neutrinoless conversion of a negative muon into an electron in the field of an Aluminum nucleus µ − N → e − N. The signature of this process is the emission of a monochromatic electron with an energy of 104.97 MeV. The Mu2e Tracker is a low mass straw tube detector, whose aim is to measure the position and the momentum of the electron. In past measurements, high values of currents were found in some panels of the Tracker in absence of any radioactive sources. In this report new measurements of currents, that were taken with the panel MN084 of the Mu2e Tracker are described. Moreover, the addition of a small amount of water vapour in the gas mixture and the influence of the environmental conditions on the currents of the panel are studied.

47 OTHER INSTRUMENTATION↗

A 4 x 4 SiPM Sensor Array with Fast Preamplified Output Engineered for the PWO Detectors of the EIC EEEMCAL

The PbWO4 scintillation detectors for the Electron-Ion Collider Electron Endcap Electromagnetic Calorimeter (EEEMCAL) cannot use vacuum photomultipler tubes due to the high magnetic field environment. We are presenting a readout solution with a 4 x 4 SiPM array directly coupled to a preamplification and summing stage. A second amplification stage with variable gain and offset adjustments is also included in the compact electronics module. The integrated power supply feeds the signal processing chain and the adjustable bias control. The parameter settings are saved locally on a EEPROM and are adjustable via the integrated communication interface through USB or RS485. The design was optimized to maximize signal collection energy resolution, for fast timing and wide dynamic range while keeping a small footprint with low power consumption and heat dissipation. The output response is fast enough to meet the 100 ? 200 ns digitization gate requirements for the detector. The electronics assembly requires no active cooling and includes a temperature sensor and a gain compensation of thermal variations which are important features for stable operation in large scale detector structures. A detector prototype was constructed with 20 mm x 20 mm x 200 mm PWO crystals affixed with individual SiPM array readouts and arranged in a 3 x 3 array. This detector was tested at the Thomas Jefferson National Accelerator Facility with 5GeV positrons. We will present the results of these detector characterization measurements.

Philip, O.↗

Accurate activity determination of a californium neutron source

Accurately counting analog events requires constructing an electronics chain that produces one count for each input pulse. Here, in this work, we review the use of Nuclear Instrumentation Module electronic units for counting neutron capture events in a 3He tube. We identify two unique types of false trigger events in a leading-edge discriminator and show how a dual timer module can be used to produce a veto window to exclude these events. We use the constructed electronics chain to build an apparatus to measure neutron pulses from a 252 Cf neutron source. We compare the measurements with a Monte Carlo N-Particle (MCNP) model to determine the activity of the neutron source. Furthermore, by making additional measurements with borated polyethylene attenuators between the source and detector, we are able to determine the boron concentration of the polyethylene. This technique provides accurate determination of the source activity to a precision of 2.8% at the k=1 level. The method used is simple, inexpensive, and requires no additional calibrated instruments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiplexing and Demultiplexing Signals for Radiography Application Using the Discrete Fourier Transform

Our goal is to develop an X-ray phase-contrast imaging system that can provide excellent soft tissue contrast of phase, attenuation, and small-angle scatter. We propose to replace the common system of G0, G1, and G2 gradings with a biprism array to replace the G1 grading and introduce a novel X-ray tube designed to replace the motion of the phase stepping grading G2. The proposed X-ray tube uses temporal multiplexing to provide simultaneous virtual “electronic phase stepping.” In this work the discrete Fourier transform is used to separate from the composite measurement individual X-ray phase contrast measurements sampled at different frequencies. The method performs a discrete Fourier transform of a composite refence sequence to obtain using the frequency amplitudes calibration factors needed to extract the X-ray phase contrast measurement amplitudes from the composite image. The composite reference sequence is the sum of the individual sequences, at different frequencies, with amplitudes of one. The method takes the discrete Fourier transform of this composite reference sequence; whereby, the amplitude of each frequency component is compared with the total sum of its stand-alone sequence amplitude. A calibration factor is determined so that the amplitude of this composite reference frequency times the calibration factor must equal the total sum of the sequence amplitude—the zero-frequency amplitude of the discrete Fourier transform of its stand-alone sequence. To demultiplex the composite measured signal these calibration factors are multiplied by the amplitudes of the frequency components of the discrete Fourier transform of the composite X-phase-contrast measurement to obtain the amplitude of each frequency encoded measurement. Using these calibration factors, we demonstrate with the discrete Fourier transform in Mathematica the extraction of individual images from a composite image that one would expect obtaining from our proposed new X-ray phase contrast imaging system. We then demonstrate as an example how using images from X-ray phase contrast data one can calculate phase, attenuation and the dark field images using grading phase step data supplied to use from Microworks, GmbH in Karlsruhe, Germany.

42 ENGINEERING↗

Enhanced Pool Boiling of Low-Pressure Refrigerants on Round Tubes- An Experimental Evaluation

Pool boiling heat transfer is one of the most effective heat transfer methos and crucial for several energy conversion processes such as electronic cooling, steam generation, water purification and thermal management. Enhancing boiling heat transfer around the tubes enables higher heat flux, which can improve the efficiency and lead to compact heat exchangers. Delaying the onset of critical heat flux (CHF) allows for higher CHFs and protects equipment during anomalous transient conditions. Growing interest in process intensification and delayed CHF has motivated the current study. An experimental approach has been deployed to investigate a potential technique to enhance the pool boiling performance around small diameter tubes by open cell metal foams. The findings for nucleate pool boiling of Novec HFE 7000 on the externally enhanced and smooth tubes are reported. The enhanced tube comprised of compressed aluminum foam brazed around. All the samples were horizontally oriented, and the experiments were performed under ambient pressure conditions. The heat transfer measurements for the smooth tubes were compared with several existing correlations and established the baseline. The preliminary results showed that the aluminum foam effectively enhanced the heat transfer coefficient and delayed the onset of critical heat flux. In addition, the pool boiling process around the round tube sample was visualized from both side and front views to comprehend the heat transfer mechanisms underlying substantial enhancement observed during experiments.

Yang, Cheng-Min↗

The ATLAS experiment at the CERN Large Hadron Collider: a description of the detector configuration for Run 3

The ATLAS detector is installed in its experimental cavern at Point 1 of the CERN Large Hadron Collider. During Run 2 of the LHC, a luminosity of ℒ = 2 × 10 34 cm -2 s -1 was routinely achieved at the start of fills, twice the design luminosity. For Run 3, accelerator improvements, notably luminosity levelling, allow sustained running at an instantaneous luminosity of ℒ = 2 × 10 34 cm -2 s -1 , with an average of up to 60 interactions per bunch crossing. The ATLAS detector has been upgraded to recover Run 1 single-lepton trigger thresholds while operating comfortably under Run 3 sustained pileup conditions. A fourth pixel layer 3.3 cm from the beam axis was added before Run 2 to improve vertex reconstruction and b-tagging performance. New Liquid Argon Calorimeter digital trigger electronics, with corresponding upgrades to the Trigger and Data Acquisition system, take advantage of a factor of 10 finer granularity to improve triggering on electrons, photons, taus, and hadronic signatures through increased pileup rejection. The inner muon endcap wheels were replaced by New Small Wheels with Micromegas and small-strip Thin Gap Chamber detectors, providing both precision tracking and Level-1 Muon trigger functionality. Trigger coverage of the inner barrel muon layer near one endcap region was augmented with modules integrating new thin-gap resistive plate chambers and smaller-diameter drift-tube chambers. Tile Calorimeter scintillation counters were added to improve electron energy resolution and background rejection. Upgrades to Minimum Bias Trigger Scintillators and Forward Detectors improve luminosity monitoring and enable total proton-proton cross section, diffractive physics, and heavy ion measurements. These upgrades are all compatible with operation in the much harsher environment anticipated after the High-Luminosity upgrade of the LHC and are the first steps towards preparing ATLAS for the High-Luminosity upgrade of the LHC. This paper describes the Run 3 configuration of the ATLAS detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A subgrid model for electron-scale turbulent transport in global ion-scale gyrokinetic simulations of tokamak plasmas

A subgrid electron–temperature–gradient (ETG) model is demonstrated here which averages local electron-scale turbulence over intermediate scales in space and time to include in global ion–temperature–gradient (ITG) simulations. This approach results in ion-scale equations, which incorporate the electron heat transport from ETG turbulence and the effects of electron-scale turbulence on the ion scale. Flux-tube ETG Cyclone Base Case simulations are performed at different radial locations and a kinetic form of the flux is added to global ion-scale (IS) simulations as a source term. Analytic radial profiles of ETG heat flux are constructed and compared to flux-tube results at multiple radial locations. Different ratios of ITG to ETG heat flux levels are considered and the results of capturing ETG heat transport in global ion-scale simulations are discussed. The potential coupling of the ETG streamer potential and intermediate-scale zonal flows to the ion scale is further addressed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗