Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron recoils”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Calibration plan for the SBC 10-kg liquid argon detector with 100 eV target threshold

The Scintillating Bubble Chamber (SBC) Collaboration is designing a new generation of low background, noble liquid bubble chamber experiments with sub-keV nuclear recoil threshold. These experiments combine the electronic recoil blindness of a bubble chamber with the energy resolution of noble liquid scintillation, and maintain electron recoil discrimination at higher degrees of superheat (lower nuclear recoil thresholds) than Freon-based bubble chambers. A 10-kg liquid argon bubble chamber has the potential to set world leading limits on the dark matter nucleon cross-section for 𝒪(GeV/c 2 ) masses, and to perform a high statistics coherent elastic neutrino nuclear scattering measurement with reactor neutrinos. This work presents a detailed calibration plan to measure the detector response of these experiments, combining photoneutron scattering with two new techniques to induce sub-keV nuclear recoils: nuclear Thomson scattering and thermal neutron capture.

Dark Matter detectors (WIMPs, axions, etc.)↗

Calibration of the liquid argon ionization response to low energy electronic and nuclear recoils with DarkSide-50

DarkSide-50 has demonstrated the high potential of dual-phase liquid argon time projection chambers in exploring interactions of WIMPs in the GeV=c 2 mass range. The technique, based on the detection of the ionization signal amplified via electroluminescence in the gas phase, allows us to explore recoil energies down to the sub-keV range. We report here on the DarkSide-50 measurement of the ionization yield of electronic recoils down to ~180 eV er , exploiting 37 Ar and 39 Ar decays, and extrapolated to a few ionization electrons with the Thomas-Imel box model. Further, we present a model-dependent determination of the ionization response to nuclear recoils down to ~500 eV nr , the lowest ever achieved in liquid argon, using in situ neutron calibration sources and external datasets from neutron beam experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detector Characterization for Accurate Monte Carlo Simulation and Neutron Energy-spectrum Unfolding

This report details the characterization of a deuterated scintillation detector for use in neutron spectroscopy via the spectrum unfolding technique. The active volume of the detector consists of a 3-in. diameter by 3 in. depth right circular cylinder that contains 337 cm3 of liquid scintillator EJ-315, deuterated benzene with a D:H ratio of 141:1. A deuterated scintillator is desirable for unfolding fast neutron energy spectra because the backscattering of neutrons from deuterium produces peaks in the pulse height response corresponding to the incident neutron energy. Spectrum unfolding requires the detector’s response to be accurately known for any input neutron energy. The characterization in this report supports using a simulated response matrix calibrated by the measured light output and convolved with the measured resolution to produce a response matrix without bringing the detector to a neutron beam facility for characterization. In particular, characterization measurements were performed that included calibration of the detector’s light output to recoil electrons from gamma sources, calibration of the detector’s resolution to recoil electrons, and calibration of the detector’s light output to recoil protons from a time-tagged neutron source and a monoenergetic 14.1 MeV neutron source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bremsstrahlung emission of the SN1987A interior

The down-scattering of gamma photons stores a significant fraction of the total energy in recoil electrons. This paper presents the bremsstrahlung emission of those recoil electrons in SN1987A. If the bolometric luminosity derives from radioactive decay, the bremsstrahlung emissivity must be present, but has not previously been treated. Initially it was our hope to account for the Ginga 16-28 keV measurement of SN1987A or to find a detectable X-ray luminosity near 1 keV for ROSAT. Although this bremsstrahlung emission fails to explain Ginga fluxes, it dominates the X-ray fluxes below 20 keV and can have detectable consequences for the X-ray lines from circumstellar matter. Results for day 175, 500, 1000, and 1500 are shown.

The, Lih-Sin↗

Gamma Ray Source Localization for Time Projection Chamber Telescopes Using Convolutional Neural Networks

Diverse phenomena such as positron annihilation in the Milky Way, merging binary neutron stars, and dark matter can be better understood by studying their gamma ray emission. Despite their importance, MeV gamma rays have been poorly explored at sensitivities that would allow for deeper insight into the nature of the gamma emitting objects. In response, a liquid argon time projection chamber (TPC) gamma ray instrument concept called GammaTPC has been proposed and promises exploration of the entire sky with a large field of view, large effective area, and high polarization sensitivity. Optimizing the pointing capability of this instrument is crucial and can be accomplished by leveraging convolutional neural networks to reconstruct electron recoil paths from Compton scattering events within the detector. In this investigation, we develop a machine learning model architecture to accommodate a large data set of high fidelity simulated electron tracks and reconstruct paths. We create two model architectures: one to predict the electron recoil track origin and one for the initial scattering direction. We find that these models predict the true origin and direction with extremely high accuracy, thereby optimizing the observatory’s estimates of the sky location of gamma ray sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Scintillating Bubble Chambers for Rare Event Searches

The Scintillating Bubble Chamber (SBC) collaboration is developing liquid-noble bubble chambers to detect sub-keV nuclear recoils, allowing the search for low-mass (GeV-scale) dark matter and coherent elastic neutrino-nucleus scattering from low-energy (MeV-scale) neutrinos. The scintillating bubble chamber detectors benefit from the energy reconstruction that the scintillation signal gives in addition to the superior electron-recoil insensitivity that bubble chambers naturally provide. The high level of superheat achievable in noble liquids while being electron-recoil insensitive allows for lower nuclear recoil thresholds than in existing freon-based bubble chambers, potentially reaching the 100 eV threshold desired for reactor CEvNS measurements. To validate this lower threshold, the SBC collaboration is constructing two 10 kg detectors that are functionally identical. The SBC-LAr10, which is being commissioned at Fermilab, is intended for engineering and calibration research and has additional possibilities in assessing coherent elastic neutrino-nucleus scattering in argon. SBC-SNOLAB, the second detector for a low-background dark matter search, will be run at SNOLAB underground.

Pyda, Daniel [Unlisted, US]↗

Systematics in the XENON1T data: The 15-keV anti-axion

The XENON1T collaboration Aprile et al. [2020] has found an excess of electron recoil events in their Science Run 1 data below ~7 keV with a spectral shape consistent with that expected from a solar-axion-induced signal. The claimed statistical significance of the solar-axion model over the null hypothesis is 3.5σ. In this work we provide suggestive evidence for mismodeling in the electron recoil data that may decrease the local significance of the axion model. To reach this conclusion, we search for a signal with the spectral template of the solar axion model, but shifted to higher (unphysical) energies above ~7 keV. We find that the distribution of significances found from this side-band analysis does not follow the expected chi-square distribution. For example, we find a high-significance feature in the data, with a global $p$-value $p≈0.026$, when the solar axion model is shifted upwards in energy by ~15 keV and allowed to have a negative normalization. We argue that such statistical tests, if performed a priori, provide a data-driven way to test and potentially account for systematic uncertainties on the background model in low-threshold dark matter experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Constraints on dark photons and axionlike particles from the SuperCDMS Soudan experiment

We present an analysis of electron recoils in cryogenic germanium detectors operated during the SuperCDMS Soudan experiment. The data are used to set new constraints on the axioelectric coupling of axion-like particles and the kinetic mixing parameter of dark photons, assuming the respective species constitutes all of the galactic dark matter. This study covers the mass range from 40 eV/$c^2$ to 500 eV/$c^2$ for both candidates, excluding previously untested parameter space for masses below ~1 keV/$c^2$. For the kinetic mixing of dark photons, values below $10^{-15}$ are reached for particle masses around 100 eV/$c^2$; for the axioelectric coupling of axion-like particles, values below $10^{-12}$ are reached for particles with masses in the range of a few-hundred eV/$c^2$.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon

Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioactive isotope, 39Ar, a ß emitter of cosmogenic origin. For large detectors, the atmospheric 39Ar activity poses pile-up concerns. The use of argon extracted from underground wells, deprived of 39Ar, is key to the physics potential of these experiments. The DarkSide-20k dark matter search experiment will operate a dual-phase time projection chamber with 50 tonnes of radio-pure underground argon (UAr), that was shown to be depleted of 39Ar with respect to AAr by a factor larger than 1400. Assessing the 39Ar content of the UAr during extraction is crucial for the success of DarkSide-20k, as well as for future experiments of the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by the DArT in ArDM experiment, a small chamber made with extremely radio-pure materials that will be placed at the centre of the ArDM detector, in the Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an active veto for background radioactivity, mostly ?-rays from the ArDM detector materials and the surrounding rock. This article describes the DArT in ArDM project, including the chamber design and construction, and reviews the background required to achieve the expected performance of the detector.

Noble liquid detectors, Dark Matter detectors, Cry↗

A Scintillating Xenon Bubble Chamber for Dark Matter Detection. Final Report

This report describes the progress in the search for particle dark matter achieved under DOE award DE-SC0012161, as well as the invention of a new dark matter and neutrino detection technique. Work supported by this award follows in three distinct thrusts: (1) the successful completion of the Generation-1 Direct Detection experiment PICO-60, which set the world-leading limit on the spin-dependent coupling of dark matter to protons and achieved a precise understanding of the response of bubble chambers to nuclear-recoil signals and electron-recoil backgrounds; (2) the construction of the Generation-2 Direct Detection experiment LZ, which will soon be the world's most sensitive dark matter detector; and (3) the demonstration of the first scintillating bubble chamber. The development of a scintillating liquid noble bubble chamber was the primary goal of the proposed work, with the aim of combining the excellent background rejection of a PICO-style bubble chamber with the event-by-event energy resolution of a liquid-noble detector such as LZ. This work produced the first ever observation of coincident scintillation and bubble nucleation by a nuclear recoil in a superheated fluid and also revealed an unexpected benefit to the use of noble liquids in a bubble chamber, namely the ability to increase the degree of superheat by an order of magnitude beyond that achievable in PICO-style detectors while maintaining PICO's world-leading background rejection. This discovery has led to new projects in the US and Canada, developing noble liquid bubble chambers both as detectors for low-mass dark matter and as detectors of coherent elastic neutrino-nucleus scattering (CEvNS) by neutrinos produced at nuclear reactors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Solar-neutrino oscillations

The theory of oscillations of solar neutrinos is developed as it applies to the electron-recoil spectrum in neutrino-electron scattering. The spectral information obtained by such measurements (as opposed to counting total event rates) is crucial for allowing observation of neutrino oscillations for masses down to 500 neV. In this regard, the effects of different masses and mixing angles, as well as such subtleties as thermal and pressure broadening, finite solar-core size, and variable indices of refraction are investigated.

Krauss, L.↗

Scintillating Bubble Chambers for Rare Event Searches

The Scintillating Bubble Chamber (SBC) collaboration is developing liquid-noble bubble chambers for the detection of sub-keV nuclear recoils. These detectors benefit from the electron recoil rejection inherent in moderately-superheated bubble chambers with the addition of energy reconstruction provided from the scintillation signal. The ability to measure low-energy nuclear recoils allows the search for GeV-scale dark matter and the measurement of coherent elastic neutrino-nucleus scattering on argon from MeV-scale reactor antineutrinos. The first physics-scale detector, SBC-LAr10, is in the commissioning phase at Fermilab, where extensive engineering and calibration studies will be performed. In parallel, a functionally identical low-background version, SBC-SNOLAB, is being built for a dark matter search underground at SNOLAB. SBC-SNOLAB, with a 10 kg-yr exposure, will have sensitivity to a dark matter–nucleon cross section of 2×10 –42 cm 2 at 1 GeV/c 2 dark matter mass, and future detectors could reach the boundary of the argon neutrino fog with a tonne-yr exposure. In addition, the deployment of an SBC detector at a nuclear reactor could enable neutrino physics investigations including measurements of the weak mixing angle and searches for sterile neutrinos, the neutrino magnetic moment, and the light Z’ gauge boson.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Directional Recoil Detection

Searches for dark matter–induced recoils have made impressive advances in the last few years. Yet the field is confronted by several outstanding problems. First, the inevitable background of solar neutrinos will soon inhibit the conclusive identification of many dark matter models. Second, and more fundamentally, current experiments have no practical way of confirming a detected signal's Galactic origin. The concept of directional detection addresses both of these issues while offering opportunities to study novel dark matter– and neutrino-related physics. The concept remains experimentally challenging, but gas time projection chambers are an increasingly attractive option and, when properly configured, would allow directional measurements of both nuclear and electron recoils. In this review, we reassess the required detector performance and survey relevant technologies. Fortuitously, the highly segmented detectors required to achieve good directionality also enable several fundamental and applied physics measurements. As a result, we comment on near-term challenges and how the field could be advanced.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Observables for recoil identification in high-definition Gas Time Projection Chambers

Directional detection of nuclear recoils is broadly desirable in nuclear and particle physics. At low recoil energies, this capability may be used to confirm the cosmological origin of a dark matter signal, to penetrate the so-called neutrino floor, or to distinguish between different neutrino sources. Gas Time Projection Chambers (TPCs) can enable directional recoil detection if the readout granularity is sufficiently high, as is the case when micro-pattern gaseous detectors (MPGDs) are utilized. A key challenge in such detectors is identifying and rejecting background electron recoil events caused by gamma rays from radioactive contaminants in the detector materials and the environment. We define new observables that can distinguish electron and nuclear recoils, even at keV-scale energies, based on the simulated ionization's topology. Here we perform a simulation study that shows these observables outperform the traditionally used discriminant, dE/dx, by up to three orders of magnitude. Furthermore, these new observables work well even at ionization energies well below 10keV and remain robust even in the regime where directionality fails.

79 ASTRONOMY AND ASTROPHYSICS↗

Scintillation yield from electronic and nuclear recoils in superfluid He 4

Superfluid $^4$He is a promising target material for direct detection of light ($<$ 1 GeV) dark matter. Possible signal channels available for readout in this medium include prompt photons, triplet excimers, and roton and phonon quasiparticles. The relative yield of these signals has implications for the sensitivity and discrimination power of a superfluid $^4$He dark matter detector. Using a 16~cm$^3$ volume of 1.75~K superfluid $^4$He read out by six immersed photomultiplier tubes, we measured the scintillation from electronic recoils ranging between 36.3 and 185~keV$_\mathrm{ee}$, yielding a mean signal size of $1.25^{+0.03}_{-0.03}$~phe/keV$_\mathrm{ee}$, and nuclear recoils from 53.2 to 1090~keV$_\mathrm{nr}$. We compare the results of our relative scintillation yield measurements to an existing semiempirical model based on helium-helium and electron-helium interaction cross sections. As a result, we also study the behavior of delayed scintillation components as a function of recoil type and energy, a further avenue for signal discrimination in superfluid $^4$He.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Atmospheric neutrinos in next-generation xenon and argon dark matter experiments

In this work, we study the sensitivity of future xenon- and argon-based dark matter and neutrino detection experiments to low-energy atmospheric neutrinos. Not accounting for experimental backgrounds, the primary obstacle for identifying nuclear recoils induced by atmospheric neutrinos in xenon is the tail of the electron recoil distribution due to pp solar neutrinos. We use the NEST code to model the solar and atmospheric neutrino signals in a xenon detector and find that an exposure of 700 tonne-years will produce a 5σ detection of atmospheric neutrinos. We explore the effect of different detector properties and find that a sufficiently long electron lifetime is essential to the success of such a measurement.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Bremsstrahlung and energetic electrons in supernovae

Explicit Monte Carlo calculations are presented for the rate of Compton scattering and for the spectrum recoil electrons per gram at discrete depths within models of supernovae, with emphasis on the bremsstrahlung emissivity within supernova interiors. The spectrum of the bremsstrahlung emissivity is calculated at E to the -1.3 for a wide range of supernova models. The radial and temporal dependence of that emissivity is calculated for two models of SN 1987A and for one model of a Type Ia and of a He core explosion model of a Type Ib. The spectrum emerging from the surface, which is then evaluated by Monte Carlo techniques, was found to be sensitive to the photoelectric opacity and inverted by it, i.e., the spectral luminosity of the bremsstrahlung component increases slowly between 1 and 30 keV even though the emissivity declines with energy within that energy band. The bremsstrahlung luminosity was found to dominate that of the primary scattered gammas for E of less than 20 keV.

Clayton, Donald D.↗

Intrinsic Fano factor of nuclear recoils for dark matter searches

Nuclear recoils in germanium and silicon are shown to have much larger variance in electron-hole production than their electron recoil counterparts for recoil energies between 10 and 200 keV. This effect—owing primarily to deviations in the amount of energy given to the crystal lattice in response to a nuclear recoil of a given energy—has been predicted by the Lindhard model. Here, we parametrize the variance in terms of an intrinsic nuclear recoil Fano factor that is 24.3 ± 0.2 and 26 ± 8 at around 25 keV for silicon and germanium, respectively. The variance has important effects on the expected signal shapes for experiments utilizing low-energy nuclear recoils such as direct dark matter searches and coherent neutrino-nucleus scattering measurements.

79 ASTRONOMY AND ASTROPHYSICS↗