Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron microscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

An Automated Scanning Transmission Electron Microscope Guided by Sparse Data Analytics

Abstract Artificial intelligence (AI) promises to reshape scientific inquiry and enable breakthrough discoveries in areas such as energy storage, quantum computing, and biomedicine. Scanning transmission electron microscopy (STEM), a cornerstone of the study of chemical and materials systems, stands to benefit greatly from AI-driven automation. However, present barriers to low-level instrument control, as well as generalizable and interpretable feature detection, make truly automated microscopy impractical. Here, we discuss the design of a closed-loop instrument control platform guided by emerging sparse data analytics. We hypothesize that a centralized controller, informed by machine learning combining limited a priori knowledge and task-based discrimination, could drive on-the-fly experimental decision-making. This platform may unlock practical, automated analysis of a variety of material features, enabling new high-throughput and statistical studies.

47 OTHER INSTRUMENTATION↗

Magnon spectroscopy in the electron microscope

Abstract The miniaturization of transistors is approaching its limits owing to challenges in heat management and information transfer speed 1 . To overcome these obstacles, emerging technologies such as spintronics 2 are being developed, which make use of the electron’s spin as well as its charge. Local phenomena at interfaces or structural defects will greatly influence the efficiency of spin-based devices, making the ability to study spin-wave propagation at the nanoscale and atomic scale a key challenge 3,4 . The development of high-spatial-resolution tools to investigate spin waves, also called magnons, at relevant length scales is thus essential to understand how their properties are affected by local features. Here we detect bulk THz magnons at the nanoscale using scanning transmission electron microscopy (STEM). By using high-resolution electron energy-loss spectroscopy with hybrid-pixel electron detectors, we overcome the challenges posed by weak signals to map THz magnon excitations in a thin NiO nanocrystal. Advanced inelastic electron scattering simulations corroborate our findings. These results open new avenues for detecting magnons and exploring their dispersions and their modifications arising from nanoscale structural or chemical defects. This marks a milestone in magnonics and presents exciting opportunities for the development of spintronic devices.

Science & Technology - Other Topics↗

X-ray diffraction and scanning electron microscope characterizations of the salt waste processing facility tank 101 and tank 104 solid samples

The “as-received” Salt Waste Processing Facility (SWPF) Tank 101 and two Tank 104 samples (pre-wash and washed solids) have been characterized using x-ray diffraction (XRD) and scanning electron microscope/energy dispersive x-ray (SEM/EDX) techniques to address the concerns for the existence of solids, which may interfere with the operational performance of the SWPF crossflow filtration process.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimal Geometry for Focused Ion Beam-Milled Samples for Direct-Pull Micro-Tensile Testing Performed In Situ in a Scanning Electron Microscope

A thorough procedure was developed to efficiently manufacture dogbone samples using focused ion beam (FIB) milling for micro-tensile testing. A Bruker PI 89 PicoIndenter, Billerica, MA, USA, was used as a case study, although the analysis and results are applicable to other micro-mechanical testing systems capable of mounting a standard, Ø12.7 mm × Ø3.2 mm pin, scanning electron microscopy (SEM) pin stub (Ted Pella, Redding, CA, USA). Nine dogbones were made from an Fe-45Cu alloy additively manufactured using powder-fed laser-directed energy deposition (DED-LB). Testing showed that fracture was confined to the gauge section for all dogbones and that the fracture mode, ductile vs. brittle, was entirely dependent on the grain orientation relative to the loading direction. The analysis showed that the measured plastic strain to failure can vary from >11% (optimal geometry) to <1% (non-optimal geometry) in micro-tensile testing of high-tensile-strength (>1 GPa) metallic materials. Subsequently, a finite element analysis (FEA) was conducted to identify the improved dogbone geometries. A total of ten thousand dogbone geometries were tested, and their dimensions were defined by a set of four adjustable parameters (corner radius, load surface angle, load surface length, and dogbone head length). The gauge width and gauge length were fixed to 4 µm and 10 µm, respectively. Three-dimensional surface plots of the stress concentration as a function of two parameters were used to identify the optimal ranges of parameter values. The addition of maximum width and length constraints, measuring 25 µm and 30 µm, respectively, allowed us to identify an optimal geometry at load surface angles of 30° and 45°. Their respective dimensions (corner radius, load surface length, and dogbone head length) are, in µm, 12, 6, and 7 and 10, 7, and 7. Testing these two optimal geometries with a range of gauge lengths from 4 to 20 µm showed that smaller gauge lengths only slightly reduced the detrimental stress concentration outside the gauge section. However, smaller gauge lengths will notably improve the FIB surface polishing step as tapering is reduced with smaller dogbone lengths.

Chemistry↗

Insights into Chemical Prelithiation of SiO x /Graphite Composite Anodes through Scanning Electron Microscope Imaging

Initial Coulombic efficiency (ICE) is critical for determining the energy density of lithium-ion batteries (LIBs) used for practical applications; however, it is typically disregarded in anode research. We used SiO x and graphite composite anodes for commercial lithium-ion batteries in our preliminary research to achieve a balance between ICE, capacity, and cycling life. ICE reached 88%; however, it needs further improvement for commercial applications. Prelithiation is a process that involves the introduction of extra lithium ions into LIBs during their manufacturing to enhance the overall performance of the LIBs. We applied a chemical prelithiation method on our SiO x /graphite composite anodes, which comprised 95 wt % of the active material mass loading on the electrode. The ICE increased from 88% to 98% using an aryllithium reagent impregnation method within 2 min of prelithiation. The anode’s specific capacity density, rate, and cycle performance also significantly improved. Scanning electron microscopy (SEM) imaging enhanced by an osmium tetroxide staining method indicated that the P-anode contained a stable solid electrolyte interface (SEI) layer after the prelithiation process and cycling electrochemical test. The P-anode’s stable charge differential peak over 500 cycles also showcases a robust artificial SEI layer that was generated by the prelithiation procedure. Here, this prelithiation process has significant potential for adoption in the LIB industry’s current electrode manufacturing process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Inhibition of Micro-pitting by Tribofilm-Forming ZrO 2 Nanocrystal Lubricant Additives: A Micro-pitting Rig and Transmission Electron Microscope Study

The drive to reduce fuel consumption in transportation has encouraged the emergence of low viscosity lubricants to reduce viscous losses in the engine, drivetrain, and other components. However, viscosity reduction increases the risk of surface damage, thus motivating the development of new anti-wear (AW) additives. Capped ZrO 2 nanocrystals (NCs) in base oils have been shown to form AW tribofilms within microscale sliding contacts. However, the potential of ZrO 2 NCs to protect surfaces subjected to rolling-sliding contact from macroscale damage, such as micro-pitting, remains unexplored. Here, we explore the ability of ZrO 2 NCs to form protective tribofilms under harsh conditions using a micro-pitting rig (MPR), consisting of a three ring-on-roller configuration. The experiments were conducted in polyalphaolephin (PAO) base oil, with and without 5 nm diameter ZrO 2 NCs, at two levels of slide-to-roll ratio (SRR) (30% and 0%) and at variable test durations up to long durations (119 h). MPR results showed the use of ZrO 2 NCs gives rise to the formation of a tribofilm covering the roller surfaces and decreases the initiation and propagation of micro-pits compared to tests in pure PAO base stock. Transmission electron microscopy (TEM) performed on focused ion beam (FIB) milled cross-sectional samples of the roller surfaces revealed the growth of dense and 50–100 nm thick ZrO 2 -based tribofilms independent of (SRR), indicating the potential for robust micro-pitting fatigue protection. Nevertheless, small cracks localized within the near surface region of the roller tested at the most severe conditions (30% SRR and 119 h) were observed. The initiation of these cracks was directly related to the presence of manganese sulphide (MnS) inclusions in the steel, revealed using TEM combined with energy dispersive spectroscopy (EDS). Furthermore, the results highlight the benefits of the protective tribofilms formed by ZrO 2 NCs and suggest approaches for further optimizing their use.

36 MATERIALS SCIENCE↗