Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron guns”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A 500 KV INVERTED GEOEMTRY FEEDTHROUGH FOR A HIGH VOLT-AGE DC ELECTRON GUN

This contribution reports on the development of an unprecedented inverted-insulator with cable connector for reliably applying 500 kV dc to a future polarized beam photogun, to be designed for operating at 350kV without field emission. Such a photogun design could then be used for generating a polarized electron beam to drive a spin-polarized positron source as a demonstrator for high energy nuclear physics at JLab. There are no commercial cable connectors that fit the large inverted insulators required for that voltage range. Our proposed concept is based on a modified epoxy receptacle with intervening SF6 layer and a test electrode in a vacuum vessel.

Hernandez-Garcia, C.↗

A Proposed Beam-Beam Test Facility COMBINE

The COmpact Machine for Beam-beam Interactions in Non-Equilibrium systems (COMBINE) is a proposed, dedicated, beam-beam test facility. This is currently a joint effort between Jefferson Lab and Old Dominion University to create a small, low energy pair of collider rings that would be used to study beam-beam interactions, as well as act as a teaching tool for students. The base design would make use of a pair of identical rings (2.5 meters per side) one rotated 180 degrees from the other, meeting at their common interaction point. These would be fed by an electron gun producing up to 125 keV electrons. The low energy will allow for beam-beam tune shifts commensurate with existing colliders, and will also allow for an exploration of the predicted effects of gear-changing, which would be performed using a variable pathlength scheme. Finally, this machine can also test linac-ring type systems.

Nissen, Edith↗

High-brightness electron injectors for high-duty cycle X-ray free electron lasers

The successful development in the last two decades of X-ray free electron lasers (FELs) with their revolutionary brightness performance has been tightly dependent on the parallel development of electron guns and injectors capable of providing the high-brightness electron beams required by FELs lasing at these short wavelengths. The ultimate brightness delivered by a linear accelerator (linac) is already set at its injector and the remaining part of the accelerator can be only designed to preserve the injector performance. The technology to be used for the accelerator part of an X-Ray FEL strongly depends on the duty-cycle at which the FEL operates. Normal-conducting, room-temperature, copper-based radio frequency (RF) technology is typically used for low duty-cycles of up to approximately 10 −3 . For higher duty-cycles and up to continuous wave (CW) operation, the linac must rely on superconductive RF technology because, with the higher duty-cycle, the increasingly higher power dissipated in normal conducting RF structures becomes excessive for the warm technology. The situation changes in the lower energy part of the accelerator, where injector schemes, based on direct current, normal-conducting, and superconducting RF electron guns, are demonstrating the beam quality performance required by high-duty-cycle X-ray FELs. In this paper we start with a description of the requirements for such injectors, followed by an overview of the pursued technologies and schemes, and by a discussion on the main differences in terms of beam dynamics between low and high duty-cycle injectors.

Sannibale, Fernando↗

Design, development and commissioning of a multi-alkali semiconductor photocathode deposition system for the IUAC Delhi light source photoinjector

A fourth-generation light source, called Delhi Light Source (DLS) based on photocathode-based RF gun has been commissioned at Inter-University Accelerator Centre, New Delhi. Presently, the electron beam is being generated from copper photocathode and the beam is being used for scheduled experiments. Soon, the semiconductor photocathode will be used to produce higher beam current. Here, to develop the semiconductor photocathode, a dedicated photocathode deposition facility was developed in collaboration with Brookhaven national Laboratory (BNL) and has been successfully commissioned and becomes operational at IUAC. This deposition facility is an integrated system with the electron gun and is a unique system as it is capable of producing, preserving (without residual gas poisoning) and in-vacuum transfer of the deposited photocathodes from the deposition chamber up to the RF electron gun. The system is designed to operate under ultra-high vacuum (UHV) and is equipped with load-lock chambers, substrate heating assembly, thickness monitoring via a quartz crystal microbalance (QCM), and an in-situ setup for quantum efficiency (QE) measurements. After testing of all the subsystems and a detailed calibration, the first deposition of a cesium telluride (Cs 2 Te) photocathode was successfully performed on a copper (Cu) substrate. This successful commissioning and initial deposition mark a significant step toward the indigenous photocathode development and lays the groundwork for further research into advanced photo emissive materials at IUAC. This paper will discuss the salient features, installation, commissioning, first semiconductor photocathode deposition and its results.

47 OTHER INSTRUMENTATION↗

Delineation of the impact on temporal behaviors of off-axis photoemission in an ultrafast electron microscope

Efforts to push the spatiotemporal imaging-resolution limits of femtosecond laser-driven ultrafast electron microscopes (UEMs) to the combined angstrom–fs range will benefit from stable sources capable of generating high bunch charges. Recent demonstrations of unconventional off-axis photoemitting geometries are promising, but connections to the observed onset of structural dynamics are yet to be established. Here we use the in-situ photoexcitation of coherent phonons to quantify the relative time-of-flight (r-TOF) of photoelectron packets generated from the Ni Wehnelt aperture and from a Ta cathode set-back from the aperture plane. We further support the UEM experiments with particle-tracing simulations of the precise electron-gun architecture and photoemitting geometries. In this way, we measure discernible shifts in electron-packet TOF of tens of picoseconds for the two photoemitting surfaces. Furthermore, these shifts arise from the impact that the Wehnelt-aperture off-axis orientation has on the electron-momentum distribution, which modifies both the collection efficiency and the temporal-packet distribution relative to on-axis emission. Future needs are identified; we expect this and other developments in UEM electron-gun configuration to expand the range of material phenomena that can be directly imaged on scales commensurate with fundamental structural dynamics.

47 OTHER INSTRUMENTATION↗

Evaluation of accuracy and resolution of the electron beam profile scanner at the Fermilab Main Injector

The objective of this work is to assess the accuracy of measurements made by the Electron Beam Profile Scanner (EBPS), which captures the trajectory of an electron beam with and without a proton beam present. The proton beam induces deflection in the electron beam, which is influenced by proton charges.For high-resolution images, the probe beam needs to be of high intensity, small diameter, and small divergence, evaluated using a YAG screen and an optical transition radiation (OTR) screen. Additionally, the point spread function (PSF) will be calculated to characterize the optical system's properties using ZEMAX software. The capabilities of the Hamamatsu Charge-Injection Device (CID) camera and Kimball Physics electron gun (e-gun) will be considered for accuracy.

Mwaniki, Matilda [IIT, Chicago; Fermilab]↗

Phase Measurements of a 140-GHz Confocal Gyro-Amplifier

The phase stability of a 140-GHz, 1-kW pulsed gyro-amplifier system and the phase dependence on the cathode voltage were experimentally measured. To optimize the measurement precision, the amplifier was operated at 47 kV and 1 A, where the output power was ~ 30 W. The phase was determined to be stable both pulse-to-pulse and during each pulse, so far as the cathode voltage and electron beam current are constant. The phase variation with voltage was measured and found to be 130 ± 30° /kV, in excellent agreement with simulations. The electron gun used in this device is non-adiabatic, resulting in a steep slope of the beam pitch factor with respect to cathode voltage. This was discovered to be the dominant factor in the phase dependence on voltage. The use of an adiabatic electron gun is predicted to yield a significantly smaller phase sensitivity to voltage, and thus a more phase-stable performance. To our knowledge, these are the first phase measurements reported for a gyro-amplifier operating at a frequency above W-band.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase Measurements of a 140-GHz Confocal Gyro-Amplifier

The phase stability of a 140-GHz, 1-kW pulsed gyro-amplifier system and the phase dependence on the cathode voltage were experimentally measured. To optimize the measurement precision, the amplifier was operated at 47 kV and 1 A, where the output power was ~30 W. The phase was determined to be stable both pulse-to-pulse and during each pulse, so far as the cathode voltage and electron beam current are constant. The phase variation with voltage was measured and found to be 130 ± 30 deg/kV, in excellent agreement with simulations. The electron gun used in this device is non-adiabatic, resulting in a steep slope of the beam pitch factor with respect to cathode voltage. This was discovered to be the dominant factor in the phase dependence on voltage. The use of an adiabatic electron gun is predicted to yield a significantly smaller phase sensitivity to voltage, and thus a more phase-stable performance. To our knowledge, these are the first phase measurements reported for a gyro-amplifier operating at a frequency above W-band.

Rosenzweig, Guy↗

Manufacturing Supply Chain Development for Modular Solar-Thermochemical Conversion Platform [Abstract]

We will develop a tunable pulsed electron source capable of generating variable intensity highly-focused electron pulses at high repetition rates. Specifically, we need to demonstrate a high-speed variable electron gun capable of generating a variable intensity electron pulse containing between 102 and 105 electrons with an accelerating voltage of 1kV focused into a spot size <100nm in diameter at with a pulse rate >10MHz (with path to 300MHz). This combined performance cannot be achieved by commercially available electron sources. The primary technology path selected for this work will be to use a photocathode approach, where an easily modulated UV laser is used to stimulate electron emission. The approach utilizes the advances made in the development of the Dynamic TEM (DTEM), though this project will be simpler in that the pulse intensity is lower and there is no requirement for coherency. Alternate paths, including using a traditional electron beam modulated using a v-shaped slit and electrostatically deflecting the beam to adjust intensity; will also be considered for future capabilities. The electron source will then be used generate optically stimulated luminescence (OSL) in lithium fluoride (LiF) substrates to demonstrate the potential for OSL to serve as a basis technology for next generation data storage systems.

42 ENGINEERING↗

Optically Stimulated Luminescence Data Storage (Abstract)

We will develop a tunable pulsed electron source capable of generating variable intensity highly-focused electron pulses at high repetition rates. Specifically, we need to demonstrate a high-speed variable electron gun capable of generating a variable intensity electron pulse containing between 102 and 105 electrons with an accelerating voltage of 1kV focused into a spot size <100nm in diameter at with a pulse rate >10MHz (with path to 300MHz). This combined performance cannot be achieved by commercially available electron sources. The primary technology path selected for this work will be to use a photocathode approach, where an easily modulated UV laser is used to stimulate electron emission. The approach utilizes the advances made in the development of the Dynamic TEM (DTEM), though this project will be simpler in that the pulse intensity is lower and there is no requirement for coherency. Alternate paths, including using a traditional electron beam modulated using a v-shaped slit and electrostatically deflecting the beam to adjust intensity; will also be considered for future capabilities. The electron source will then be used generate optically stimulated luminescence (OSL) in lithium fluoride (LiF) substrates to demonstrate the potential for OSL to serve as a basis technology for next generation data storage systems.

42 ENGINEERING↗

NSUF Report EBSD analyses on metallic fuel samples: Tips and improvements in sample preparation

EBSD (Electron Backscatter Diffraction) is an analytic technique used to evaluate the microstructure of a specimen. It can be used to evaluate interesting crystallographic data ranging from grains size to grain orientation, from grain boundaries to stresses. Moreover, in the field of nuclear materials EBSD can aid in estimating properties important for reactor performance, such as dislocation and residual strain [1]. EBSD patterns are generated by focusing a stationary electron gun on the specimen and detecting the backscatter electrons that satisfy Bragg conditions, and thus are diffracted by the crystal planes forming the so called Kikuchi bands. These bands correspond to each of the lattice diffracting crystal planes and are detected on a phosphor screen via a low-light CCD camera [2]. The patterns are generated within a small interaction volume located at a depth of less than 50-100 nm. Because of this, the data quality is extremely sensitive to the integrity of the crystallographic lattice order at the surface of the sample and thus to sample preparation and to oxidation [3]. While conventional sample preparation methods are widely used in materials science, they often do not lead to quality electron backscatter patterns needed for the characterization of nuclear materials [4]. This has been related by many authors to the challenges associated with handling radiological specimens, their rapid oxidation, and artifacts in such samples (e.g. high number of defects, precipitates and/or porosities) [4-8]. EBSD, however, can be an invaluable technique to evaluate microstructural evolution during fabrication and after irradiation at the required mesoscale for model and simulation. It also provides important information on grain structure necessary to understand irradiation effect, such as grain subdivision. Thus, it is of paramount importance to further the application of this technique to nuclear materials and especially irradiated fuels.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Commissioning & Characterization of Magnetized Gridded Thermionic Electron Source

Collaborative efforts to design and fabricate a magnetized gridded thermionic electron source have been conducted between Xelera and Jefferson Lab. Commissioning and characterization of an electron gun fabricated by Xelera was performed to benchmark the viability of future electron source designs and capabilities. The work involved simulation, installation, trouble-shooting, modifications of the design, commissioning, characterization, and magnetization of the electron beam produced. A specially designed cavity as well as novel diagnostic tools and methods were developed, implemented, and experimentally tested. Finally, the gun was used to demonstrate a previously unachieved current of magnetized electron beam from a gridded thermionic source of this uniquely compact size. This thesis addresses the following scientific and technological challenges: building a compact gridded thermionic electron source, producing high current magnetized electron beam, and demonstrating novel characterization measurements for magnetized beam.

Stefani, Mark↗

Toward Å-fs-meV Resolution in Electron Microscopy: Systematic Simulation of the Temporal Spread of Single-Electron Packets

Though efforts to improve the temporal resolution of transmission electron microscopes (TEMs) have waxed and waned for decades, with relatively recent advances routinely reaching sub-picosecond scales, fundamental and practical challenges have hindered the advance of combined Å-fs-meV resolutions, particularly for core-loss spectroscopy and real-space imaging. This is due in no small part to the complexity of the approach required to access timescales upon which electrons, atoms, molecules, and materials first begin to respond and transform – attoseconds to picoseconds. Here we present part of a larger effort devoted to systematically mapping the instrument parameter space of a TEM modified to reach ultrafast timescales. With General Particle Tracer, we studied the statistical temporal distributions of single-electron packets as a function of various fs pulsed-laser parameters and electron-gun configurations and fields for the exact architecture and dimensions of a Thermo Fisher Tecnai Femto ultrafast electron microscope. We focused on easily-adjustable parameters, such as laser pulse duration, laser spot size, photon energy, Wehnelt aperture diameter, and photocathode size. In addition to establishing trends and dispersion behaviors, we identify regimes within which packet duration can be 100s of fs and approach the 300-fs laser limit employed here. Overall, the results provide a detailed picture of the temporal behavior of single-electron packets in the Tecnai Femto gun region, forming the initial contribution of a larger effort.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Towards advanced polarized electron sources

Polarized electrons play an important role in high-energy and nuclear physics, and their properties have also been exploited in ultrafast electron microscopy. Currently, gallium arsenide crystals illuminated by circular polarized infrared laser light are commonly used for generating polarized electrons. However, the achievable accelerating voltage and the gradient of these electrostatic sources limit the beam quality and quantity. A solution could be to combine gallium arsenide photocathodes with radio-frequency electron guns, which are capable of accelerating beams with significantly higher gradients and voltage. Here we report the successful operation of a gallium arsenide photocathode in a superconducting radio-frequency gun. Our findings are relevant for future sources of polarized electrons.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design of high-performance guns for the HL-LHC HEL

The High Luminosity LHC project (HL-LHC) foresees the construction and installation of important new equipment to increase the performance of the LHC machine. The Hollow Electron Lens (HEL) is a promising system to control the beam halo. It improves the beam collimation system of the HL-LHC and mitigates possible equipment damage in case of failure scenarios from halo losses. The halo can store up to 30 MJ energy. The specifications for this new device are quite demanding. The source, an electron gun with an annular shaped cathode, must deliver a current up to 5 A. Additionally, this is five times higher than the current in the existing electron lenses in Fermi and Brookhaven national laboratories. This note describes the programme carried out to design and test high-perveance guns equipped with two types of high-performance scandate cathodes. The size of the final gun for the HL-LHC lenses is now considerably smaller than the one of the first prototype, allowing a reduction of diameter and cost of the superconducting magnet system used to steer the electron beam. The tests carried out at FNAL, BVERI and BJUT demonstrated that the developed cathodes fulfil the specifications and can supply a 5 A fully Space Charge Limited (SCL) current.

43 PARTICLE ACCELERATORS↗