Engineering PapersSearch

SEARCH · Engineering Papers

Results for “electron counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The development and test of multi-anode microchannel array detector systems. Part 2: Soft X-ray detectors

Detector systems based on the high gain microchannel plate (MCP) electron multiplier were used extensively for imaging at soft X-ray wavelengths both on the ground and in space. The latest pulse counting electronic readout systems provide zero readout noise, spatial resolutions (FWHM) of 25 microns or better and can determine the arrival times of detected photons to an accuracy of the order of 100 ns. These systems can be developed to produce detectors with active areas of 100 nm in diameter or greater. The use of CsI photocathodes produces very high detective quantum efficiencies at wavelengths between about 100 and 1A (approximately 0.1 to 10 keV) with moderate energy resolution. The operating characteristics of the different types of soft X-ray MCP detector systems are described and the prospects for future developments are discussed.

Timothy, J. G.

Microchannel plates and image detection at soft X-ray wavelengths

Detector systems based on the high-gain microchannel plate (MCP) electron multiplier have been used extensively for imaging at soft X-ray wavelengths both on the ground and in space. The latest pulse-counting electronic readout systems provide zero readout-noise, spatial resolutions (FWM) of 25 microns or better and can determine the arrival times of detected photons to an accuracy of the order of 100 ns. These systems can br developed to produce detectors with active areas of 100 mm in diameter or greater. The use of CsI photocathodes produces very high detective quantum efficiencies to wavelengths between about 100 and 1A (0.1 to 10 keV) with moderate energy resolution. The operating characteristics of the different types of soft X-ray MCP detector systems are described, and the prospects for future developments are discussed.

Timothy, J. G.

Energetic charged particles in the Uranian magnetosphere

The cosmic ray instrument on Voyager 2 obtained detailed charged particle data on the path the spacecraft followed through the newly-discovered Uranian magnetosphere. Notably, the electron counts did not rise above background until the spacecraft was deep in the magnetosphere. The data further indicated that the satellites Miranda, Ubriel and Ariel impose a sweep effect on MeV electrons, which move radially inward from some source in the outer magnetosphere or the magnetotail. The energetic particle data also supported a firm pitch angle dependence for proton energy spectra in the 1-8 MeV range. Finally, the particle density data were commensurate with a dipole magnetic field tilted 60.1 deg in relation to the planet and rotating every 17.4 hr, close to estimates from other instruments.

Stone, E. C.

Bldg. 7930 Cell G Neutron Detector New Electronics Testing

The Cell G neutron assay system within 7930 provides an important function in the production of Californium-252 in the quantitative determination of the amount of Cf-252 present in a sample. The assay system consists of a Uranium-238 fission chamber coupled to the necessary counting electronics including preamplifier, amplifier, discriminator and counter/timer. The original electronics date back to the 1970s but were replaced back in 2011 with little documentation detailing the testing and replacement efforts. This work focused on procuring a new spare set of electronics, their subsequent testing as a backup in case any of the currently in use electronics were to fail and documentation of the existing and new setups.

Taylor, Neil [Oak Ridge National Laboratory (ORNL)

The 4D Camera: An 87 kHz Direct Electron Detector for Scanning/Transmission Electron Microscopy

We describe the development, operation, and application of the 4D Camera—a 576 by 576 pixel active pixel sensor for scanning/transmission electron microscopy which operates at 87,000 Hz. The detector generates data at ~480 Gbit/s which is captured by dedicated receiver computers with a parallelized software infrastructure that has been implemented to process the resulting 10–700 Gigabyte-sized raw datasets. The back illuminated detector provides the ability to detect single electron events at accelerating voltages from 30 to 300 kV. Through electron counting, the resulting sparse data sets are reduced in size by 10--300× compared to the raw data, and open-source sparsity-based processing algorithms offer rapid data analysis. The high frame rate allows for large and complex scanning diffraction experiments to be accomplished with typical scanning transmission electron microscopy scanning parameters.

47 OTHER INSTRUMENTATION

Measurements of electron detection efficiencies in solid state detectors.

Detailed laboratory measurement of the electron response of solid state detectors as a function of incident electron energy, detector depletion depth, and energy-loss discriminator threshold. These response functions were determined by exposing totally depleted silicon surface barrier detectors with depletion depths between 50 and 1000 microns to the beam from a magnetic beta-ray spectrometer. The data were extended to 5000 microns depletion depth using the results of previously published Monte Carlo electron calculations. When the electron counting efficiency of a given detector is plotted as a function of energy-loss threshold for various incident energies, the efficiency curves are bounded by a smooth envelope which represents the upper limit to the detection efficiency. These upper limit curves, which scale in a simple way, make it possible to easily estimate the electron sensitivity of solid-state detector systems.

Lupton, J. E.

Effect of Electronic Shot Noise on Dynamic Measurements using Optical Techniques: Examples from Rayleigh Scattering and Unsteady PSP

Electronic shot noise is an unavoidable reality in all optical techniques that depend on measuring light intensity. For steady-state, time-averaged measurements the impact of shot noise can be easily reduced by increasing the exposure time, or by averaging over multiple-exposures. That is not the case for unsteady measurements, where time histories of light intensity variations need to be created either by high-speed photography (unsteady PSP) or via photoelectron counting (spectrally resolved Rayleigh scattering) over short time durations using a photo-multiplier tube (PMT) and photon counting electronics. Electronic shot noise introduces a fixed amount of random error, which can overwhelm the light intensity variation caused by turbulent fluctuations. Spectrum computed from such time series shows a fixed noise floor that is independent of the number of data points in the time series. For a fixed optical system, where the collected power of the luminescent light (uPSP), or the scattered light (Rayleigh) is fixed, one needs to resort to special techniques to obtain enough signal-to noise ratio (SNR). For the uPSP application it is shown that averaging of the adjacent pixels improves SNR; although this may lead to a sacrifice of spatial resolution. A second means is to increase the exposure time, which leads to a lowering of the frequency range. For the Rayleigh application, improvements of SNR can be achieved via two different cross-correlation based approaches. The first involves measuring the light intensity using two PMTs using short, contiguous gates; thereby, creating two time-series of data. The second one involves collecting one long time-series of data using one set of measurement device, followed by an odd-even splitting into two time series. When the two time-series are cross-correlated, and a power spectrum is calculated, a significant reduction in the shot noise floor can be achieved. Examples from measurements of density and velocity fluctuations spectra from two different Rayleigh setup are presented to demonstrate the process.

uPSP

Accounting for electron-beam-induced warping of molecular nanocrystals in MicroED structure determination

High-energy electrons induce sample damage and motion at the nanoscale to fundamentally limit the determination of molecular structures by electron diffraction. Using a fast event-based electron counting (EBEC) detector, we characterize beam-induced, dynamic, molecular crystal lattice reorientations (BIRs). These changes are sufficiently large to bring reciprocal lattice points entirely in or out of intersection with the sphere of reflection, occur as early events in the decay of diffracted signal due to radiolytic damage, and coincide with beam-induced migrations of crystal bend contours within the same fluence regime and at the same illuminated location on a crystal. These effects are observed in crystals of biotin, a series of amino acid metal chelates, and a six-residue peptide, suggesting that incident electrons inevitably warp molecular lattices. The precise orientation changes experienced by a given microcrystal are unpredictable but are measurable by indexing individual diffraction patterns during beam-induced decay. Reorientations can often tilt a crystal lattice several degrees away from its initial position before irradiation, and for an especially beam-sensitive Zn(II)-methionine chelate, are associated with dramatic crystal quakes prior to 1 e − Å −2 electron beam fluence accumulates. Since BIR coincides with the early stages of beam-induced damage, it echoes the beam-induced motion observed in single-particle cryoEM. As with motion correction for cryoEM imaging experiments, accounting for BIR-induced errors during data processing could improve the accuracy of MicroED data.

Vlahakis, Niko (ORCID:0000000250920265)

Interstitial Atoms and the Frustrated and Allowed Structural Transitions Principle: Tunability in the Electronic Structure of AuCu 3 ‐type Frameworks in Dy 4 T 1− x Ga 12 (T = Ag, Ir)

In this Article, we explore how the chemical pressure (CP) features of an intermetallic phase may provide opportunities to couple perturbations in electron count with the stabilization of the underlying geometrical structure. AuCu 3 ‐type LnGa 3 (Ln = lanthanide or group 3 metal) phases contain octahedral cavities of negative CP held open by overly compressed Ln–Ga interactions, leading to a series of transition metal‐stuffed derivatives. We present new additions to this family with the synthesis and crystal structures of Dy 4 T 1−x Ga 12 with (T, x) = (Ag, 0.29) and (Ir, 0.15), adopting Y 4 PdGa 12 ‐type superstructures of the AuCu 3 ‐type. density functional Ttheory (DFT)‐CP calculations, when adjusted to avoid dipolar CP features, affirm that T atom incorporation provides a mechanism for the relief of packing tensions, while electronic density of states distributions illustrate that the T atoms serve largely as electron or hole donors to the band structure, as needed for them to attain d 10 configurations. The maximum obtainable value for x may be limited by a mismatch between the Fermi energy and pseudogap, in line with the balance of factors envisioned by the frustrated and allowed structural transitions principle. Furthermore, trends in resistivity measurements on T = Ir, Pd, and Ag compounds are interpretable in terms of the varying degrees of disorder arising from x < 1.0.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Valence instability and collapse of ferromagnetism in EuB 6 at high pressures

Despite the simplicity of their cubic crystal lattice, rare-earth hexaborides display complex physical properties including a (long debated) onset of metallization via magnetic polaron formation at T c1 approximate to 15 K preceding ferromagnetic ordering at T c2 approximate to 12 K. Here, in this work, we used applied pressure to tune the interplay between electronic structure and magnetism in EuB6. We probed the magnetism, valence, and structure of EuB 6 under quasi-hydrostatic pressures up to 30 GPa using X-ray techniques. Our findings show evidence for collapse of ferromagnetism above 20 GPa following a monotonic increase of mean Eu valence. While X-ray diffraction measurements in the paramagnetic state at room temperature show that the lattice retains cubic symmetry, a measurable quadrupole interaction seen by time-domain synchrotron Mössbauer spectroscopy suggests a lowering of symmetry associated with magnetic ordering, becoming more prominent across the magnetic transition. The interplay between conduction band electron count and magnetism observed under applied pressure in EuB 6 opens possibilities for fine-tuning metallization and magnetic properties of similar Eu-based semi-metal systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Integrated design of aluminum-enriched high-entropy refractory B2 alloys with synergy of high strength and ductility

Refractory high-entropy alloys (RHEAs) are promising high-temperature structural materials. Their large compositional space poses great design challenges for phase control and high strength-ductility synergy. The present research pioneers using integrated high-throughput machine learning with Monte Carlo simulations supplemented by ab initio calculations to effectively navigate phase selection and mechanical property predictions, developing single-phase ordered B2 aluminum-enriched RHEAs (Al-RHEAs) demonstrating high strength and ductility. These Al-RHEAs achieve remarkable mechanical properties, including compressive yield strengths up to 1.7 gigapascals, fracture strains exceeding 50%, and notable high-temperature strength retention. They also demonstrate a tensile yield strength of 1.0 gigapascals with a ductility of 9%, albeit with B2 ordering. Furthermore, we identify valence electron count domains for alloy ductility and brittleness with the explanation from density functional theory and provide crucial insights into elemental influence on atomic ordering and mechanical performance. The work sets forth a strategic blueprint for high-throughput alloy design and reveals fundamental principles governing the mechanical properties of advanced structural alloys.

Science & Technology - Other Topics

DarkNESS: developing a skipper-CCD instrument to search for Dark Matter from Low Earth Orbit

The DarkNESS (Dark Matter Nano-satellite Equipped with Skipper Sensors) mission aims to deploy a skipper-CCD CubeSat Observatory to search for dark matter (DM) from Low Earth Orbit. This mission will employ novel skipper-CCDs to investigate O(keV) X-rays from decaying DM, as well as electron recoils from strongly-interacting sub-GeV DM. The DarkNESS mission will be the first space deployment of skipper-CCDs, and the DarkNESS team is developing a skipper-CCD instrument that is compatible with the CubeSat platform. DarkNESS has recently progressed from laboratory validation to a Critical Design Review (CDR) phase, with a launch opportunity anticipated in late 2025. The implementation of the DarkNESS skipper-CCD payload on the CubeSat platform will pave the way for future demonstrators of space-based imagers for X-ray and single-electron counting applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

A digital multichannel photometer

Semiconductor diode image tube system as digital multichannel photometer, noting cost, weight and size advantages over photomultiplier tube array with pulse counting electronics

Beaver, E. A.

Absolute calibration of ultraviolet filter photometry

The essential features of the calibration procedure can be divided into three parts. First, the shape of the bandpass of each photometer was determined by measuring the transmissions of the individual optical components and also by measuring the response of the photometer as a whole. Secondly, each photometer was placed in the essentially-collimated synchrotron radiation bundle maintained at a constant intensity level, and the output signal was determined from about 100 points on the objective. Finally, two or three points on the objective were illuminated by synchrotron radiation at several different intensity levels covering the dynamic range of the photometers. The output signals were placed on an absolute basis by the electron counting technique described earlier.

Bless, R. C.

Titan photometric parameters

Measurements of the irradiance of Titan from 0.05 to 1.08 micrometer were carried out by 60-inch reflector, spectrometer, and pulse counting electronics. An approximate contour of the geometric albedo assumes methane is the principal absorber. The albedo of Titan reaches a maximum value of 0.37 at 0.68, 0.753, and 0.83 micrometers, while in the center of the strongest absorption features, at 0.89 and 1.0. micrometer, it falls to 0.10. Comparison with the methane bands of Jupiter and Saturn indicates that the maxima clearly do not represent the continuum and that the lower values may well be depressed by wings of methane bands adjacent to them.

Younkin, R. L.

Preliminary interpretation of plasma electron observations at the third encounter of Mariner 10 with Mercury

Plasma electron count observations made during the first and third encounters of Mariner 10 with Mercury (i.e., during Mercury I and III) are reported. They provide detailed information on the magnetosphere of Mercury, especially those from Mercury III. A low-flux region was observed about closest approach (CA) of Mercury III, whereas no such region was detected by the lower-latitude Mercury I; a hot plasma sheet was measured on the outgoing (and near-equator) trajectory of Mercury I, while only cool plasma sheets were observed in the magnetosphere by Mercury III. Findings are similar, on a reduced scale, to models of the earth's magnetosphere and magnetosheath.

Hartle, R. E.

Mossbauer effect in the ion-implanted iron-carbon alloys

The concentration dependence of Mossbauer effect in four carbon ion-implanted iron absorbers, which contain carbon as the solute atoms, has been investigated over the range of concentration 0.05 through 1 atomic percent. The specimens were prepared by implanting carbon atoms on each reference iron foil with four different bombarding energies of 250 keV, 160 keV, 140 keV and 80 keV, respectively. Thus, the specimen contains a uniform dosage of carbon atoms which penetrated up to 3,000 A depth of the reference iron. In the measurement of Mossbauer spectra, the backscattering conversion electron counting geometry was used. Typical results of Mossbauer parameters of iron-carbon alloys show that the isomer shift, quadrupole shift, the effective hyperfine splitting of Fe-57, and the intensity ratio exhibit a large variation with the increase of carbon concentration in the environment of iron atoms.

Han, K. S.