Engineering PapersSearch

SEARCH · Engineering Papers

Results for “electromagnetic calorimeters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Highly boosted dielectron identification in proton-proton collisions at $\sqrt{s}$ = 13 TeV

A new technique is developed to identify dielectrons (e$^+$e$^-$) with Lorentz boost $γ_\mathrm{L}$$\gt$ 20 that produce one single merged cluster in the electromagnetic calorimeter of the CMS detector. The identification uses two multivariate models: one for the case where both electron tracks are reconstructed, and another where only one of the tracks is reconstructed. The efficiency is determined using proton-proton collision data collected at a center-of-mass energy of 13 TeV. Boosted J/$ψ$ mesons decaying into e$^+$e$^-$ pairs are used to estimate the efficiency of the model with two tracks, yielding an overall efficiency of 80%. The Z $\to$ $μ^+μ^-γ$ events, where the photon converts into a collimated dielectron, are used for the model with a single track, yielding an efficiency of about 60%. A dedicated energy correction for dielectron candidates is also developed using B$^\pm$ $\to$ J/$ψ$K$^\pm$ $\to$ e$^+$e$^-$K$^\pm$ data.

Hayrapetyan, A. [Yerevan Phys. Inst.]

Measurement of inclusive jet cross section and substructure in 𝑝 + 𝑝 collisions at $\sqrt{s}$ = 200 GeV

The jet cross section and jet-substructure observables in 𝑝 + 𝑝 collisions at $\sqrt{s}$ =200 GeV were measured by the PHENIX Collaboration at the Relativistic Heavy Ion Collider (RHIC). Jets are reconstructed from charged-particle tracks and electromagnetic-calorimeter clusters using the anti-𝑘 𝑡 algorithm with a jet radius of 𝑅 = 0.3 for jets with transverse momentum within 8.0 < 𝑝 𝑇 < 40.0 GeV/𝑐 and pseudorapidity |𝜂| < 0.15. Measurements include the jet cross section, as well as distributions of SoftDrop-groomed momentum fraction (𝑧 𝑔 ), charged-particle transverse momentum with respect to jet axis (𝑗 𝑇 ), and radial distributions of charged particles within jets (𝑟). Also measured was the distribution of 𝜉 = −ln⁡(𝑧), where 𝑧 is the fraction of the jet momentum carried by the charged particle. The measurements are compared to theoretical next-to and next-to-next-to-leading-order calculations, the PYTHIA and H erwig event generators, and to other existing experimental results. Indicated from these measurements is a lower particle multiplicity in jets at RHIC energies when compared to models. Also noted are implications for future jet measurements with sPHENIX at RHIC as well as at the future Electron-Ion Collider.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Unifying simulation and inference with normalizing flows

There have been many applications of deep neural networks to detector calibrations and a growing number of studies that propose deep generative models as automated fast detector simulators. We show that these two tasks can be unified by using maximum likelihood estimation (MLE) from conditional generative models for energy regression. Unlike direct regression techniques, the MLE approach is prior independent and non-Gaussian resolutions can be determined from the shape of the likelihood near the maximum. Using an ATLAS-like calorimeter simulation, we demonstrate this concept in the context of calorimeter energy calibration. Published by the American Physical Society 2025

Hadronic calorimiters

Scintillating glass for precision calorimetry in nuclear physics

High-performance scintillator materials are needed for particle identification and measurements of energy and momentum of electromagnetic particles in modern nuclear physics experiments. As an example, the US Electron-Ion Collider, a unique collider with diverse physics topics, requires electromagnetic calorimetry enabling high-quality electron identification and detection in the momentum range of 0.3 to tens of GeV. The highest resolution in electromagnetic calorimeters can be provided by homogeneous materials, e.g., lead tungstate crystals. Inorganic glass scintillators have been investigated as an attractive and cost-effective alternative to crystals, that is also easier and faster to manufacture in mass production. In this paper, we discuss progress in the fabrication and characterization of recent scintillating glass samples on both test bench and beam tests. Further, the results are well-reproduced by simulation and are discussed in the context of the Electron-Ion Collider experimental requirements and bench-marked against lead tungstate crystals.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Measurement of the inclusive isolated-photon production cross section in pp collisions at $\mathbf {\sqrt{\textit{s}}=13}$ TeV

The production cross section of inclusive isolated photons has been measured by the ALICE experiment at the CERN LHC in pp collisions at centre-of-momentum energy of $\mathbf {\sqrt{\textit{s}}=13}$ TeV collected during the LHC Run 2 data-taking period. The measurement is performed by combining the measurements of the electromagnetic calorimeter EMCal and the central tracking detectors ITS and TPC, covering a pseudorapidity range of and a transverse momentum range of |η γ | < 0.67 and a transverse momentum range 7 < p$^{γ}_{T}$ < 200 GeV/c. The result extends to lower p$^{γ}_{T}$ and x$^{γ}_{T}$ = 2p$^{γ}_{T}$/$\sqrt{s}$ ranges, the lowest x$^{γ}_{T}$ of any isolated photon measurements to date, extending significantly those measured by the ATLAS and CMS experiments towards lower p$^{γ}_{T}$ at the same collision energy with a small overlap between the measurements. The measurement is compared with next-to-leading order perturbative QCD calculations and the results from the ATLAS and CMS experiments as well as with measurements at other collision energies. The measurement and theory prediction are in agreement with each other within the experimental and theoretical uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

The SAND detector for the DUNE experiment

The Deep Underground Neutrino Experiment (DUNE) is a next-generation project aiming to study several neutrino properties. It will feature two experimental setups: a near detector that will be installed at Fermilab, in proximity of the neutrino-production point, and a far detector at a distance of 1300 km and 1500 m underground, at the SURF laboratory. The DUNE design and configuration will allow the study of neutrino oscillation, astrophysical neutrinos, and beyond standard model physics. The near detector complex foresees three detectors to be installed. Among these, the System for on-Axis Neutrino Detection (SAND) will serve as on-axis beam monitor, reduce the systematic uncertainties for the oscillation analysis, and search for physics beyond the standard model. SAND will be composed of three sub-detectors, surrounded by a 0.6 T superconducting magnet. The outermost detector will be a lead/scintillating-fiber electromagnetic calorimeter while the inner volume will include a 1-ton liquid argon active target placed upstream followed by a target tracker system. The SAND detector and its goals will be shown in this poster.

Alemanno, Francesca [Salento U.; INFN, Lecce]

Precision Measurement of the Muon Spin Precession Frequency in the Fermilab Muon g-2 Experiment

The Fermilab Muon $g-2$ Experiment is designed to measure the muon's anomalous magnetic moment, $ a_\mu = (g-2)/2 $ with an accuracy of 140 parts per billion. This quantity is determined from two key measurements; the difference between the muon's spin precession frequency and its cyclotron frequency, given by $\omega_a = \omega_s - \omega_c$, and $\tilde{\omega_p^\prime}$, proportional to the muon-weighted magnetic field.In this talk, we focus on presenting the methodology for determining $\omega_a$. Muons with a momentum of 3.1 GeV are injected into a storage ring, and $\omega_a$ is extracted from the time distribution of decay positrons recorded by 24 electromagnetic calorimeters placed symmetrically inwards around the ring. We present the final result from the muon g-2 collaboration and analysis techniques based on data collected from 2020 to 2023.

Zaid, Estifa'a [Liverpool U.]

Crystal Calorimetry for Charged Lepton Flavor Violation Searches

The Mu2e experiment at Fermilab aims to search for Charged Lepton Flavor Violation (CLFV) through the coherent conversion of a muon into an electron in the field of an aluminum nucleus. This process, highly suppressed in the Standard Model, would clearly indicate new physics if observed. A crucial component of Mu2e is its electromagnetic calorimeter, which enhances the identification and measurement of conversion electrons. The calorimeter consists of two disks of undoped CsI crystals read out by custom-designed SiPMs and fast front-end electronics. This paper presents an overview of the calorimeter’s design, its custom SiPM technology, the readout and data acquisition system, and the results from commissioning tests.Building on the experience from Mu2e, the proposed Mu2e-II upgrade aims to enhance further the experiment’s sensitivity by an order of magnitude. This requires significant advancements in calorimeter technology, particularly in crystal materials and photodetector performance. Studies on BaF$_2$ and LYSO crystals, as well as the development of radiation-hard Silicon Photomultipliers (SiPMs), are currently underway. Test beam results demonstrate promising improvements in energy resolution and timing capabilities, ensuring the feasibility of next-generation calorimetry solutions for Mu2e-II.

Atanov, N. [Dubna, JINR]

Diagnostic Systems in the Muon $g-2$ experiment at Fermilab

The muon anomalous magnetic moment, $a_\mu=\frac{g-2}{2}$, is a low-energy observable which can be both measured and computed to high precision, making it a sensitive test of the Standard Model and a probe for new physics. This anomaly was measured with a precision of $0.20$~parts per million (ppm) by the Fermilab's Muon g-2 (E989) experiment. The final goal of the E989 experiment is to reach a precision of $0.14$~ppm. The experiment is based on the measurement of the muon spin anomalous precession frequency, $\omega_a$, based on the arrival time distribution of high-energy decay positrons observed by 24 electromagnetic calorimeters, placed around the inner circumference of a $14$~m diameter storage ring, and on the precise knowledge of the storage ring magnetic field and of the beam time and space distribution. Achieving this level of precision requires strict control over systematics, which is ensured through several diagnostic devices. At the accelerator level, these devices monitor the quality of the injected beam (e.g., verifying that it has the correct momentum), while at the detector level, they track both the magnetic field and the gain of the calorimeters. In this work the devices and techniques used by the E989 experiment will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Melting LHC detectors: a novel search for stopped long-lived particles

Particles at the TeV scale with lifetimes of a year or longer could have been abundantly produced at the LHC yet escaped detection because of backgrounds, and could still be trapped within detector materials. With gluinos in split-supersymmetry as a working example, we show that these trapped particles can be recovered from detector materials once prepared in liquid form, for example, by melting silicon detectors, extracting liquid argon from the electromagnetic calorimeter, or constructing a large water pool near ATLAS or CMS. These liquid samples can then be processed using iterative centrifugation followed by mass spectrometry, enabling single-particle sensitivity in macroscopic samples. This method can potentially discover gluinos up to 3 TeV in mass at the HL-LHC. It can also improve upon existing limits for other long-lived particles. For example, it can discover the stop up to 2 TeV, and will also be sensitive to integer-charged particles in the TeV range.

Gonski, Julia L. [SLAC]

Measurement of the muon anomalous precession frequency in runs 4, 5, and 6 of the muon ${g}-2$ Experiment at Fermilab

The Fermilab E989 Muon $g-2$ experiment measures the muon's anomalous magnetic moment to a precision of 127 parts per billion, as reported in June 2025. The value is proportional to the difference between the muon's cyclotron frequency and the spin precession frequency in the presence of a uniform magnetic field, for muons contained within the $g-2$ storage ring. Spin precession frequency is extracted from the time distribution of the muon's decay positrons recorded by 24 electromagnetic calorimeters positioned around the inner circumference of the storage ring. The anomalous precession frequency is one of the primary experimental inputs necessary to estimate the anomalous magnetic moment, the other being the measurement of the magnetic field. This dissertation details the anomalous precession frequency extraction, including reconstruction, time-distribution fitting, and treatment of systematic uncertainties for the final three data-collection runs: Run-4, Run-5, and Run-6. This data represents a fourfold increase in statistics over the previous analysis release, halving the statistical uncertainty. The residual slow term from previous analyses is now well understood and documented in a systematic treatment. As of the writing of this dissertation, the theoretical prediction for the SM estimate of the muon's anomalous magnetic moment is under debate, with two competing prediction methods, so a definitive comparison with theory is not available. The results submitted for experimental release use the kernel-ratio asymmetry method, contributing 115 parts per billion to the statistical uncertainty and 34 parts per billion to the systematic uncertainty. When combined with the previous analyses in earlier data runs, this thereby improves the measurement beyond the experimental goal and sets the world's most precise measurement of the muon's anomalous magnetic moment.

Israel, Scott Nathan [Boston U.]

Measurement of the muon anomalous precession frequency in runs 4, 5, and 6 of the muon ${g}-2$ Experiment at Fermilab

The Fermilab E989 Muon $g-2$ experiment measures the muon's anomalous magnetic moment to a precision of 127 parts per billion, as reported in June 2025. The value is proportional to the difference between the muon's cyclotron frequency and the spin precession frequency in the presence of a uniform magnetic field, for muons contained within the $g-2$ storage ring. Spin precession frequency is extracted from the time distribution of the muon's decay positrons recorded by 24 electromagnetic calorimeters positioned around the inner circumference of the storage ring. The anomalous precession frequency is one of the primary experimental inputs necessary to estimate the anomalous magnetic moment, the other being the measurement of the magnetic field. This dissertation details the anomalous precession frequency extraction, including reconstruction, time-distribution fitting, and treatment of systematic uncertainties for the final three data-collection runs: Run-4, Run-5, and Run-6. This data represents a fourfold increase in statistics over the previous analysis release, halving the statistical uncertainty. The residual slow term from previous analyses is now well understood and documented in a systematic treatment. As of the writing of this dissertation, the theoretical prediction for the SM estimate of the muon's anomalous magnetic moment is under debate, with two competing prediction methods, so a definitive comparison with theory is not available. The results submitted for experimental release use the kernel-ratio asymmetry method, contributing 115 parts per billion to the statistical uncertainty and 34 parts per billion to the systematic uncertainty. When combined with the previous analyses in earlier data runs, this thereby improves the measurement beyond the experimental goal and sets the world's most precise measurement of the muon's anomalous magnetic moment.

Israel, Scott Nathan [Boston U.]

Measurement of the muon anomalous precession frequency in Runs 4, 5, and 6 of the Muon g-2 experiment at Fermilab

The Fermilab E989 Muon g − 2 experiment measures the muon’s anomalous magnetic moment to a precision of 127 parts per billion, as reported in June 2025. The value is proportional to the difference between the muon’s cyclotron frequency and the spin precession frequency in the presence of a uniform magnetic field, for muons contained within the g − 2 storage ring. Spin precession frequency is extracted from the time distribution of the muon’s decay positrons recorded by 24 electromagnetic calorimeters positioned around the inner circumference of the storage ring. The anomalous precession frequency is one of the primary experimental inputs necessary to estimate the anomalous magnetic moment, the other being the measurement of the magnetic field. This dissertation details the anomalous precession frequency extraction, including reconstruction, time-distribution fitting, and treatment of systematic uncertainties for the final three data-collection runs: Run-4, Run-5, and Run-6. This data represents a fourfold increase in statistics over the previous analysis release, halving the statistical uncertainty. The residual slow term from previous analyses is now well understood and documented in a systematic treatment. As of the writing of this dissertation, the theoretical prediction for the SM estimate of the muon’s anomalous magnetic moment is under debate, with two competing prediction methods, so a definitive comparison with theory is not available. The results submitted for experimental release use the kernel-ratio asymmetry method, contributing 115 parts per billion to the statistical uncertainty and 34 parts per billion to the systematic uncertainty. When combined with the previous analyses in earlier data runs, this thereby improves the measurement beyond the experimental goal and sets the world’s most precise measurement of the muon’s anomalous magnetic moment.

Israel, Scott Nathan [Boston U.]

EXCLUSIVE NEUTRAL PION ELECTROPRODUCTION CROSS SECTION MEASUREMENTSWITHANEUTRALPARTICLE SPECTROMETER

Deep Virtual Compton Scattering (DVCS), the exclusive electron-proton scattering process ep ¿e'p'¿, provides access to generalized parton distributions (GPDs), which correlate information about the longitudinal momentum and transverse spatial structure of quarks inside the nucleon. Experiment E12-13-010 in Hall C at Jefferson Lab was designed to take high-precision measurements of the DVCS cross section over an extended kinematic range using the newly commissioned Neutral Particle Spectrometer (NPS). The NPS features a high-resolution electromagnetic calorimeter and a streaming data acquisition system optimized for operation at high luminosities. This thesis presents the detector and analysis work carried out to support the NPS DVCS program. In particular, it focuses on the hardware design, calibration, and performance of the calorimeter. A development of a waveform reconstruction analysis of the calorimeter signals enabled improved extraction of pulse amplitudes and times. The waveform analysis was also extended to operate in a multithreaded environment, substantially reducing processing time for large datasets. Analysis of exclusive neutral pion electroproduction events in the calorimeter gives a strong validation of the calorimeter’s performance and resolution. Together these developments establish a foundation for future analyses and extraction of the DVCS cross section and its use in constraining the GPDs.

Kerver, Mitchell [Old Dominion Univ., Norfolk, VA

Development of Advanced, Radiation Resistant, Optical-based Detector Technology for Future Experiments.

The primary objective of this project has been to advance the design of high-performance electromagnetic (EM) calorimeters for future particle physics experiments, to identify and measure the timing, position and energy of electrons, positrons and gamma rays, particularly in high-luminosity environments with intense radiation and pileup conditions. To meet such challenges, the proposed research has focused on the development of ultra-compact, radiation-hard calorimeter modules, to provide excellent timing, spatial, and energy resolution. The work aligns with the DOE’s Basic Research Needs (BRN) for High Energy Physics (HEP) Instrumentation and the research team contributes actively to the Coordinating Panel on Advanced Detectors (CPAD) RDC9 calorimetry collaboration in the USA and the European Committee on Future Accelerators (ECFA) DRD-CALO calorimetry collaboration at CERN, the European Laboratory for Particle Physics located in Geneva, Switzerland. The research builds on the RADiCAL (radiation-hard, ultra-compact) modular sampling calorimeter approach, developed by the research team, which employs dense and very bright optical materials such as LYSO:Ce scintillator plates that are interleaved with very dense tungsten plates to minimize detector size while optimizing performance. The modules are comparable in size to a human index finger, dimensionally 14 mm x 14 mm in cross section and 135 mm in length. And despite the small size, the structure is capable of providing excellent timing and energy resolution. This is facilitated through the use of specialized quartz capillaries filled with wavelength-shifting filaments, positioned at various depths along the length of a module, to collect and guide light signals to silicon photomultipliers (SiPMs) which detect and convert the optical signals to electronic signals for analysis. The primary goals of this project have been: (1) Achieve a timing resolution to σ t ≤ 30 ps for high-energy electrons and photons, important for their association with specific events produced in colliding-beam experiments and for the detection of decays-in-flight of long-lived particles. The project has achieved this goal in beam tests of a single RADiCAL module at CERN, during which a timing resolution of σ t = 27 ps was measured for electrons of energy E = 150 GeV. Based upon a mathematical fit to the data measured over a broad energy range from low energy to high energy, a resolution of σ t ≤ 18 ps has been estimated for electrons of very high (TeV) energy. From these measurements and with further expected technical improvements, the timing resolution should reach σ t ≤ 10 ps, important for searches for discovery physics in upcoming and future experiments. (2) Achieve an energy resolution of σ E / E ≤ 10% / $\sqrt{E}$. The project has yet to achieve this goal, but is close to it, having measured a value of σ E / E ≤ 15.9% / $\sqrt{E}$ using a modular array. Ultimately, the resolution goal is expected to be reached by adjustments to material thicknesses within the modules, which will improve the sampling fraction to measure more precisely the shower energy for lower energy particles. The versatility of the modular RADiCAL approach enables the testing of advanced materials, photosensors and electronics, developed in collaboration with CPAD RDC and ECFA DRD-CALO groups. The structure can distinguish electrons, positrons and gamma rays from hadrons and muons and beam-induced backgrounds, making it a valuable tool in a variety of detector environments, including future circular colliders (FCC-ee, FCC-hh) proposed for the European Laboratory for Particle Physics (CERN), the muon-collider proposed for Fermi National Accelerator Laboratory (Fermilab), and searches for new physics in beam-dump, fixed target and forward-physics experiments. And, while designed with particle physics applications in mind, the technologies developed in this project have the potential for application more broadly in particle and nuclear physics, materials science, and medical physics, underscoring the far-reaching potential of this line of instrumentation research and development.

47 OTHER INSTRUMENTATION

Commissioning of the large-scale lead tungstate scintillating calorimeter

Here, we report on the installation and initial commissioning of a large-scale lead tungstate (PbWO4) scintillating crystal calorimeter developed for high-rate photon detection and precise energy measurement. The calorimeter comprises 1596 high-granularity, high-resolution scintillating crystals optimized for electromagnetic-shower detection over a wide energy range. Scintillation light from each crystal is read out by Hamamatsu R4125 photomultiplier tubes equipped with a custom voltage divider and front-end amplifier to ensure stable gain at high rates. All calorimeter modules were fabricated and characterized using a light-emitting diode–based optical test system prior to installation to verify uniformity and photodetector performance. After installation, the electromagnetic calorimeter was fully integrated into the experiment data acquisition and energy-based trigger systems. The optical response of the modules was equalized using the light-monitoring system, cosmic-ray muons, and photons from Compton-scattering events. Commissioning results demonstrate a reliably calibrated optical response and stable detector performance during the first run. These results validate the calorimeter design and commissioning methodology for large-scale scintillator-based photonic instrumentation.

Analog to digital converters

An apparatus for the specific heat measurement of undercooled liquids

This paper describes a drop calorimeter with an electromagnetic levitator that was specifically built for enthalpy measurements of undercooled liquids, including high-melting-point metals. Design diagrams of this device and of a furnace for making a suspended drop are presented together with results of measurements on an aluminum sample.

Ohsaka, K.

Data Analysis for the Scintillating Optical Fiber Calorimeter (SOFCAL)

The scintillating optical fiber calorimeter is a hybrid instrument with both active and passive components for measuring the proton and helium cosmic ray spectra from 0.2 to IO TeV kinetic energy. A thin emulsion/x-ray film chamber is situated between a cerenkov counter and an imaging calorimeter. Scintillating optical fibers sample the electromagnetic showers that develop in the calorimeter and identify the trajectory of cosmic rays that interact in SOFCAL. The emulsion/x-ray film data provide an in flight calibration for SOFCAL. The data reduction techniques used will be discussed and interim results of the analysis from a 20 hour balloon flight will be presented.

Christl, Mark J.