Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrolyzer cells”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Hydrogen-oxygen proton-exchange membrane fuel cells and electrolyzers

Hydrogen-oxygen SPE fuel cells and SPE electrolyzers (products of Hamilton Standard) both use a Proton-Exchange Membrane (PEM) as the sole electrolyte. The SPE cells have demonstrated a ten year life capability under load conditions. Ultimate life of PEM fuel cells and electrolyzers is primarily related to the chemical stability of the membrane. For perfluorocarbon proton-exchange membranes an accurate measure of the membrane stability is the fluoride loss rate. Millions of cell hours have contributed to establishing a relationship between fluroride loss rates and average expected ultimate cell life. Several features were introduced into SPE fuel cells and SPE electrolyzers such that applications requiring greater than or equal to 100,000 hours of life can be considered. Equally important as the ultimate life is the voltage stability of hydrogen-oxygen fuel cells and electrolyzers. Here again the features of SPE fuel cells and SPE electrolyzers have shown a cell voltage stability in the order of 1 microvolt per hour. That level of stability were demonstrated for tens of thousands of hours in SPE fuel cells at up to 500 amps per square foot (ASF) current density. The SPE electrolyzers have demonstrated the same at 1000 ASF. Many future extraterrestrial applications for fuel cells require that they be self recharged. To translate the proven SPE cell life and stability into a highly reliable extraterrestrial electrical energy storage system, a simplification of supporting equipment is required. Static phase separation, static fluid transport and static thermal control will be most useful in producting required system reliability. Although some 200,000 SPE fuel cell hours were recorded in earth orbit with static fluid phase separation, no SPE electrolyzer has, as yet, operated in space.

Baldwin, R.↗

Hydrogen-oxygen proton-exchange membrane fuel cells and electrolyzers

Hydrogen-oxygen solid polymer electrolyte (SPE) fuel cells and SPE electrolyzers (products of Hamilton Standard) both use a Proton-Exchange Membrane (PEM) as the sole electrolyte. These solid electrolyte devices have been under continuous development for over 30 years. This experience has resulted in a demonstrated ten-year SPE cell life capability under load conditions. Ultimate life of PEM fuel cells and electrolyzers is primarily related to the chemical stability of the membrane. For perfluorocarbon proton exchange membranes an accurate measure of the membrane stability is the fluoride loss rate. Millions of cell hours have contributed to establishing a relationship between fluoride loss rates and average expected ultimate cell life. This relationship is shown. Several features have been introduced into SPE fuel cells and SPE electrolyzers such that applications requiring greater than or equal to 100,000 hours of life can be considered. Equally important as the ultimate life is the voltage stability of hydrogen-oxygen fuel cells and electrolyzers. Here again the features of SPE fuel cells and SPE electrolyzers have shown a cell voltage stability in the order of 1 microvolt per hour. That level of stability has been demonstrated for tens of thousands of hours in SPE fuel cells at up to 500 amps per square foot (ASF) current density.

Baldwin, R.↗

Fuel cell and electrolyzer hotbox module using conductive zirconia stacks

Modular pressurized hotbox for use and substitution in a variety of pressurized electrochemical applications to include reversible solid oxide electrolyzer and fuel cells, energy storage systems, renewable fuel production, solid-state hydrogen pumping and liquefaction, and oxygen transport membranes. This is enabled by mixed electronic and ionic conducting compositions of vanadia-yttria and vanadia-calcia stabilized zirconia and a dry powder method of manufacture for ceramic core stacks.

McLarty, Dustin↗

Performance-Limiting Factors of Hydrocarbon Ionomeric Binders for Fuel Cells and Electrolyzers

Here, the move toward nonfluorinated hydrocarbon ionomers for fuel cells and electrolyzers is driven by potential restrictions on polyfluoroalkyl substances such as Nafion. This study examines the key limitations of hydrocarbon ionomers through half- and single-cell experiments with model hydrocarbon ionomers. Half-cell tests reveal three major performance barriers: undesirable adsorption, electrochemical oxidation, and low gas permeability. Competitive sulfate adsorption helps counteract ionomer adsorption and oxidation. These findings align with single-cell performance data, which further reveal additional oxygen mass transport limitations likely caused by localized electrode flooding. Together, these findings offer valuable insights to guide the development of high-performance, fluorine-free hydrocarbon ionomers for next-generation fuel cells and electrolyzers.

Choi, Jong-Ho [Los Alamos National Laboratory (LAN↗

In-line, High-Throughput Quality Monitoring for Fuel Cell and Electrolyzer Components Based on Transmission and Reflection Imaging

During the manufacturing of fuel cell and electrolyzer membranes and membrane electrode assemblies (MEAs), real-time, in-line, high-throughput optical-based quality monitoring methods are essential for detecting defects and monitoring thickness variations, thus improving the performance and increasing the durability of fuel cell and electrolyzer in the hydrogen industry. For the MEAs with very opaque coatings, optical transmission-based imaging has been developed and applied in the Roll-to-Roll system using a flashlight and a high-sensitivity CCD camera. We observed high signal-to-noise ratio images while the Roll-to-Roll system ran at 5 ft/min. The entire sample image could quickly be recovered from the discrete frames using customized Python codes for automatic frame cropping and stitching. We detected significant non-uniformities in our experimental MEAs specimen. For fuel cell and low-temperature electrolysis (LTE) transparent membranes, we used optical reflectance hyperspectral imaging with interference fringe-based thickness mapping. We set up a hyperspectral camera to measure various rolls of commercial membranes. The measurement results are analyzed to find the thickness distribution of each roll and to check for defects. Transmission and reflection imaging-based quality monitoring techniques demonstrated in this project can be widely used in the mass production environment to improve the production yield and performance of hydrogen devices.

DIRECT ENERGY CONVERSION,ENGINEERING↗

Hydrocarbon Ionomeric Binders for Fuel Cells and Electrolyzers

Abstract Ionomeric binders in catalyst layers, abbreviated as ionomers, play an essential role in the performance of polymer–electrolyte membrane fuel cells and electrolyzers. Due to environmental issues associated with perfluoroalkyl substances, alternative hydrocarbon ionomers have drawn substantial attention over the past few years. This review surveys literature to discuss ionomer requirements for the electrodes of fuel cells and electrolyzers, highlighting design principles of hydrocarbon ionomers to guide the development of advanced hydrocarbon ionomers.

25 ENERGY STORAGE↗

Phenyl‐Free Polynorbornenes for Potential Anion Exchange Ionomers for Fuel Cells and Electrolyzers

Abstract Ionomers in the catalyst layer play a critical role in the performance of fuel cells and electrolyzers. Phenyl adsorption on hydrogen oxidation catalysts and electrochemical oxidation of phenyl moieties on oxygen evolution catalysts are detrimental to the alkaline devices’ performance. Here the adsorption energy of phenyl‐containing ionomers is compared to provide the rationale for implementing phenyl‐free ionomers. Density functional theory calculations indicated that the norbornane fragment has minimal adsorption energy on Pt(111) due to the absence of aromatic π electrons. A soluble quaternized polynorbornene ionomer is prepared by vinyl addition polymerization, and it exhibits high performance in both fuel cells and electrolyzers, proving the advantage of the phenyl‐free structure. This study establishes the phenyl adsorption energy‐electrode performance relationship, highlighting the importance of material interactions between the catalysts and ionomers.

25 ENERGY STORAGE↗

NASA Tech Briefs, June 2014

Topics include: Real-Time Minimization of Tracking Error for Aircraft Systems; Detecting an Extreme Minority Class in Hyperspectral Data Using Machine Learning; KSC Spaceport Weather Data Archive; Visualizing Acquisition, Processing, and Network Statistics Through Database Queries; Simulating Data Flow via Multiple Secure Connections; Systems and Services for Near-Real-Time Web Access to NPP Data; CCSDS Telemetry Decoder VHDL Core; Thermal Response of a High-Power Switch to Short Pulses; Solar Panel and System Design to Reduce Heating and Optimize Corridors for Lower-Risk Planetary Aerobraking; Low-Cost, Very Large Diamond-Turned Metal Mirror; Very-High-Load-Capacity Air Bearing Spindle for Large Diamond Turning Machines; Elevated-Temperature, Highly Emissive Coating for Energy Dissipation of Large Surfaces; Catalyst for Treatment and Control of Post-Combustion Emissions; Thermally Activated Crack Healing Mechanism for Metallic Materials; Subsurface Imaging of Nanocomposites; Self-Healing Glass Sealants for Solid Oxide Fuel Cells and Electrolyzer Cells; Micromachined Thermopile Arrays with Novel Thermo - electric Materials; Low-Cost, High-Performance MMOD Shielding; Head-Mounted Display Latency Measurement Rig; Workspace-Safe Operation of a Force- or Impedance-Controlled Robot; Cryogenic Mixing Pump with No Moving Parts; Seal Design Feature for Redundancy Verification; Dexterous Humanoid Robot; Tethered Vehicle Control and Tracking System; Lunar Organic Waste Reformer; Digital Laser Frequency Stabilization via Cavity Locking Employing Low-Frequency Direct Modulation; Deep UV Discharge Lamps in Capillary Quartz Tubes with Light Output Coupled to an Optical Fiber; Speech Acquisition and Automatic Speech Recognition for Integrated Spacesuit Audio Systems, Version II; Advanced Sensor Technology for Algal Biotechnology; High-Speed Spectral Mapper; "Ascent - Commemorating Shuttle" - A NASA Film and Multimedia Project DVD; High-Pressure, Reduced-Kinetics Mechanism for N-Hexadecane Oxidation; Method of Error Floor Mitigation in Low-Density Parity-Check Codes; X-Ray Flaw Size Parameter for POD Studies; Large Eddy Simulation Composition Equations for Two-Phase Fully Multicomponent Turbulent Flows; Scheduling Targeted and Mapping Observations with State, Resource, and Timing Constraints;

Source record↗

Performance degradation in proton-conducting ceramic fuel cell and electrolyzer stacks

Proton-conducting ceramics are emerging as enabling materials for efficient electrochemical electricity generation, energy storage, and fuels synthesis. In this work, we present longer-term degradation results for protonic-ceramic fuel cells and electrolyzers based on a BaCe 0.4 Zr 0.4 Y 0.1 Yb 0.1 O 3-δ (BCZYYb) electrolyte. The cells are packaged within unit-cell stacks, including metallic interconnects, current collectors, sealing glasses and gaskets. Durability is found to be superior in protonic-ceramic electrolyzers in comparison to fuel cells. Operating conditions have a large impact on degradation rates; better stability is found at fuel-cell operating temperatures above 600 °C, and electrolyzer steam feeds below 20%. Here, we find that both fuel-cell and electrolyzer degradation is greatly reduced via the introduction of a gadolinium-doped ceria interlayer between the electrolyte and the air–steam electrode. Fuel-cell degradation falls to 1.2% khr –1 under methane fuel at 600 °C; electrolyzer degradation is reduced to 1% khr –1 at 550 °C and 50% steam. Further analyses of electrochemical impedance spectroscopy and distribution of relaxation times provide insight to root processes and degradation phenomena in protonic electroceramics.

25 ENERGY STORAGE↗

High Performance Fuel Cell and Electrolyzer Membrane Electrode Assemblies (MEAs) for Space Energy Storage Systems

Regenerative fuel cells provide a pathway to energy storage system development that are game changers for NASA missions. The fuel cell/ electrolysis MEA performance requirements 0.92 V/ 1.44 V at 200 mA/cm2 can be met. Fuel Cell MEAs have been incorporated into advanced NFT stacks. Electrolyzer stack development in progress. Fuel Cell MEA performance is a strong function of membrane selection, membrane selection will be driven by durability requirements. Electrolyzer MEA performance is catalysts driven, catalyst selection will be driven by durability requirements. Round Trip Efficiency, based on a cell performance, is approximately 65%.

Plastic Encapsulated Microelectronics (PEM)↗

A Highly Efficient and Affordable Hybrid System for Hydrogen and Electricity Production (Final Project)

The pursuit of clean, secure, and sustainable energy has sparked significant interest in fuel cells for power generation and electrolyzer cells for hydrogen production. Among all types of fuel and electrolyzer cells, solid oxide cells (SOCs) have emerged as promising candidates due to their high efficiency and versatility. However, conventional oxygen-ion conductive SOCs face several challenges related to their performance and durability associated with their high-temperature operation (≥ 800 ºC). This has led to a growing interest in intermediate-temperature (≤ 650 ºC) proton-conducting solid oxide cells (p-SOCs) as potential alternatives. In collaboration between Phillips 66 and Georgia Tech, this project aims to achieve a 1 kW p-SOCs system to demonstrate the commercial viability of efficient SOC systems. This report addresses four primary areas and key challenges we overcame: (1) development of efficient and durable proton-conducting electrolyte (e.g., BaHf 0.1 Ce 0.7 Yb 0.2 O 3-δ ) and electrode/catalyst materials, (2) large area cell fabrication (10 x 10 cm 2 ), (3) scalable stack design and building (250 W and 1 kW), and (4) demonstration of a 1 kW prototype system. Notably, significant challenges faced during the large area cell fabrication process were addressed by achieving cell flatness, improving fabrication yield, and ensuring electrode/electrolyte interfacial adhesion. Stack designs were also developed, focusing on reducing contact resistance and optimizing stack components (e.g., sealants). These efforts resulted in the achievement of high performance and durability with promising outputs of 250 W and 1 kW. Furthermore, the integration of these stacks into a fuel-powered system was explored, with refinements made to heat management, as well as to pressure and heating conditions. The results demonstrated the potential applicability of our p-SOC technology in commercial energy storage and power generation systems. Additionally, the report discusses techno-economic analysis and a market transformation plan, aiming to evaluate and advance the commercial feasibility of this technology.

25 ENERGY STORAGE↗

Ozone generator system

An ozone generator system utilizes an electrochemical cell to produce and control ozone concentrations within an enclosure or to supply ozone to a flow conduit. The enclosure may he coupled with a flow conduit that carries the produced ozone to a desired location. An enclosure may be a sterilization chamber and the concentration of ozone produced by the ozone generating system may be sufficient to sterilize articles within the enclosure. An oxygen control electrolyzer cell and/or humidity control electrolyzer cell may be coupled with the enclosure to further control the environment of the enclosure. A humidity control electrolyzer cell may be fluidly coupled with the ozone generator to supply humidity for reaction on the anode of the ozone generator.

Bahar, Bamdad↗

Controlling Mass Transport in Direct Carbon Dioxide Zero-Gap Electrolyzers via Cell Compression

The development of high-performance CO 2 electrolyzers is crucial for accelerating the sustainable production of fuels and chemicals integrated with renewable energy sources. Here, we introduce a methodology to actively control mass transport inside a realistic zero-gap membrane electrode assembly of a CO 2 electrolyzer by varying the gasket thickness, which consequently changes the cell compression. This allows control over the thickness and porosity of the gas diffusion electrodes, influencing the overall electrolyzer performance, as demonstrated using Ag-deposited electrodes. At low operating voltages (<2.9 V), both high- and low-compression electrolyzers exhibit similar faradaic efficiencies and partial current densities for CO formation. However, at high voltages, the low-compression electrolyzer with high electrode porosity demonstrates superior CO selectivity and activity with suppressed H 2 formation. These experimental results are validated by the computational membrane electrode assembly (MEA) model developed by using the measured in situ electrode thicknesses and electrode porosities. Additionally, liquid electrolyte saturation at the catalyst layer is found to play a dominant role in determining the mass transport, resulting in a decreased electrolyzer performance with low electrode porosity. Finally, the systematic investigation in this study improves the understanding of the transport dynamics in MEA-based devices and provides insights into optimizing device design parameters for industry-relevant CO 2 electrolysis.

30 DIRECT ENERGY CONVERSION↗

System for capturing CO2 from a fuel cell

A carbon dioxide capture system for capturing carbon dioxide from an exhaust stream. The system may include a fuel cell configured to output a first exhaust stream comprising carbon dioxide and water. The system may further include an electrolyzer cell configured to receive a first portion of the first exhaust stream and output a second exhaust stream comprising oxygen and carbon dioxide. The fuel cell may be a solid oxide fuel cell. The electrolyzer cell may be a molten carbonate electrolysis cell.

30 DIRECT ENERGY CONVERSION↗

International Meeting on Fuel Cell and Electrolyzer Quality Control: Summary Report

Quality control (QC) for both polymer electrolyte membrane fuel cell and electrolysis membrane electrode assembly (MEA) materials is a key challenge for scale-up and cost reduction. Developing methods for detecting defects, as well as measuring critical material properties and understanding the impact of as-manufactured variations in these materials on cell performance and lifetime, are critical barriers. To help address these needs, the National Research Council Canada (NRC), Fraunhofer Institute for Solar Energy Systems (ISE), and the National Renewable Energy Laboratory (NREL) have organized and facilitated a series of workshops on the topic, bringing together industry, academia, and research institutions from North America and Europe. Prior workshops in Canada and Germany have focused on the status of quality tool capabilities and identification of needed developments for fuel cells. These meetings have garnered an excellent response and follow-on attendance, with over 100 unique attendees.

30 DIRECT ENERGY CONVERSION↗

Hydrogen-oxygen proton-exchange membrane fuel cells and electrolyzers

A flight experiment is planned for the validation, in a microgravity environment, of several ground-proven simplification features relating to SPE fuel cells and SPE electrolyzers. With a successful experiment, these features can be incorporated into equipment designs for specific extraterrestrial energy storage applications.

Baldwin, R.↗