Neuro-Prosthetic Implants With Adjustable Electrode Arrays

Brushlike arrays of electrodes packaged with application-specific integrated circuits (ASICs) are undergoing development for use as electronic implants especially as neuro-prosthetic devices that might be implanted in brains to detect weak electrical signals generated by neurons. These implants partly resemble the ones reported in Integrated Electrode Arrays for Neuro-Prosthetic Implants (NPO-21198), NASA Tech Briefs, Vol. 27, No. 2 (February 2003), page 48. The basic idea underlying both the present and previously reported implants is that the electrodes would pick up signals from neurons and the ASICs would amplify and otherwise preprocess the signals for monitoring by external equipment. The figure presents a simplified and partly schematic view of an implant according to the present concept. Whereas the electrodes in an implant according to the previously reported concept would be microscopic wires, the electrodes according to the present concept are in the form of microscopic needles. An even more important difference would be that, unlike the previously reported concept, the present concept calls for the inclusion of microelectromechanical actuators for adjusting the depth of penetration of the electrodes into brain tissue. The prototype implant now under construction includes an array of 100 electrodes and corresponding array of electrode contact pads formed on opposite faces of a plate fabricated by techniques that are established in the art of microelectromechanical systems (MEMS). A mixed-signal ASIC under construction at the time of reporting the information for this article will include 100 analog amplifier channels (one amplifier per electrode). On one face of the mixed-signal ASIC there will be a solder-bump/micro-pad array that will have the same pitch as that of the electrode array, and that will be used to make the electrical and mechanical connections between the electrode array and the ASIC. Once the electrode array and the ASIC are soldered together, the remaining empty space between them will be filled with a biocompatible epoxy, the remaining exposed portions of the ASIC will be covered with micromachined plates for protection against corrosive bodily fluids, and then the ASIC and its covering micromachined plates will be coated with parylene

Whitacre, Jay↗

Research into the use of pyrolytic oxides and polymers for the fabrication of thin film high energy capacitors

Construction, capacitance and dissipation factor, and electrode materials for single layer capacitors are discussed. Basic construction, phosphosilicate glass, ten layer capacitors, twenty layer capacitors, stress measurements, buffered oxide layers, and 30 layer capacitors are also discussed. Spin-on phosphosilicate glass is addressed. Polymers as dielectric materials are also considered.

Nevin, J. H.↗

Integrated Solid-Electrolyte Construction

Proposed construction method for electrolytic cells would integrate porous surface electrodes into a block of solid electrolyte. Porous electrodes would facilitate unrestricted gas flow thereby improving cell performance. Electrode wire mesh is embedded at surface of solid electrolyte. Construction would assure high electrode conductance and low resistance to gas flow.

Richter, R.↗

Study directed at development of an implantable biotelemetry ion detector

A literature search was conducted to currently update known information in the field of ion-selective electrodes. The review attempts to identify present trends in cation and anions selective electrodes pertinent to the area of bioimplantable units. An electronic circuit was designed to provide the high impedance interface between the ion-selective sensors and signal-processing equipment. The resulting design emphasized the need for low power and miniaturization. Many of the circuits were constructed and used to evaluate the ion-selective electrodes. A cuvette capable of holding the ion-selective and the reference electrodes was designed and constructed. This equipment was used to evaluate commercially available ion-selective electrodes and the electrodes designed and constructed in the study. The results of the electrode tests are included.

Hanley, L. D.↗

Bonded electrodes for use on the external surface of spacecraft

A new bonding process is described which is suitable for applying electrodes to the external surfaces of spacecraft and sounding rockets. A polyimide material containing small, uniform glass spheres provides the necessary insulation and mechanical strength. The bonded electrodes are simple to construct and are shown to have good electrical, vacuum, and thermal properties.

Kendall, B. R. F.↗

Improved Einzel lenses

New insulator configuration simplifies construction of three-electrode electrostatic electron lenses in which center electrode is at high electrical potential. Spherical sapphire insulators are used in lieu of conventional tubular ceramic or plastic insulators in Einzel lens assembly.

Hart, R. K.↗

Ultraviolet laser excitation source

A new intense ultraviolet light source has been developed from an array of hypocycloidal pinch (HCP) devices. The basic unit of the array is constructed with three disk electrodes and is capable of producing dense plasmas at temperatures up to 10,000,000 K. Very high input power levels to the array are possible without significantly shortening its useful life, in strong contrast with conventional xenon flashlamps. The new light source, when operated with Ar and Xe gas mixtures at high pressures (approximately 5 x 10 to the 4th Pa), produced a light output of over 100 MW in the near-UV spectral range and successfully pumped an iodine photodissociation laser at 1.315 microns. A xenon recombination laser at 2.027 microns was also pumped in the HCP array.

Lee, J. H.↗

Non-gassing nickel-cadmium battery electrodes and cells

Supposedly long-lived nickel-cadmium batteries often fail due to severe gassing on charge. In order to increase the lives of such cells attempts are being made to construct nongassing positive and negative electrodes. The gassing characteristics of both electrodes in negative limited cells were determined as a function of charge rate, charge temperature, and loading. Cycle life tests, up to 70 cycles, of some of the cells show they operate in a nongassing manner with very low degradation rates.

Luksha, E.↗

Electrochemical processing of solid waste

The investigation into electrolysis as a means of waste treatment and recycling on manned space missions is described. The electrochemical reactions of an artificial fecal waste mixture was examined. Waste electrolysis experiments were performed in a single compartment reactor, on platinum electrodes, to determine conditions likely to maximize the efficiency of oxidation of fecal waste material to CO2. The maximum current efficiencies for artificial fecal waste electrolysis to CO2 was found to be around 50 percent in the test apparatus. Experiments involving fecal waste oxidation on platinum indicates that electrodes with a higher overvoltage for oxygen evolution such as lead dioxide will give a larger effective potential range for organic oxidation reactions. An electrochemical packed column reactor was constructed with lead dioxide as electrode material. Preliminary experiments were performed using a packed-bed reactor and continuous flow techniques showing this system may be effective in complete oxidation of fecal material. The addition of redox mediator Ce(3+)/Ce(4+) enhances the oxidation process of biomass components. Scientific literature relevant to biomass and fecal waste electrolysis were reviewed.

Bockris, J. OM.↗

Micromachined silicon tunnel sensor for motion detection

The extreme sensitivity of electron tunneling to variations in electrode separation has been used to construct a novel, compact displacement transducer. Electrostatic forces are used to control the separation between the tunneling electrodes, thereby eliminating the need for piezoelectric actuators. The entire structure is composed of micromachined silicon single crystals, including a folded cantilever spring and a tip. Measurements of displacement sensitivity and noise are reported. This device offers a substantial improvement over conventional technology for applications which require compact, highly sensitive transducers.

Kenny, T. W.↗

Single Wall Carbon Nanotube-Based Structural Health Sensing Materials

Single wall carbon nanotube (SWCNT)-based materials represent the future aerospace vehicle construction material of choice based primarily on predicted strength-to-weight advantages and inherent multifunctionality. The multifunctionality of SWCNTs arises from the ability of the nanotubes to be either metallic or semi-conducting based on their chirality. Furthermore, simply changing the environment around a SWCNT can change its conducting behavior. This phenomenon is being exploited to create sensors capable of measuring several parameters related to vehicle structural health (i.e. strain, pressure, temperature, etc.) The structural health monitor is constructed using conventional electron-beam lithographic and photolithographic techniques to place specific electrode patterns on a surface. SWCNTs are then deposited between the electrodes using a dielectrophoretic alignment technique. Prototypes have been constructed on both silicon and polyimide substrates, demonstrating that surface-mountable and multifunctional devices based on SWCNTs can be realized.

Watkins, A. Neal↗

Dust Removal Technology Demonstration for a Lunar Habitat

We have developed an Electrodynamic Dust Shield (EDS), an active dust mitigation technology with applications to solar panels, thermal radiators, optical systems, visors, seals and connectors. This active technology is capable of removing dust and granular material with diameters as large as several hundred microns. In this paper, we report on the development of three types of EDS systems for NASA's Habitat Demonstration Unit (HDU). A transparent EDS 20 cm in diameter with indium tin oxide electrodes on a 0.1 mm-thick polyethylene terephtalate (PET) film was constructed for viewport dust protection. Two opaque EDS systems with copper electrodes on 0.1 mm-thick Kapton were also built to demonstrate dust removal on the doors of the HDU. A lotus coating that minimizes dust adhesion was added to one of the last two EDS systems to demonstrate the effectiveness of the combined systems.

Calle, C. I.↗

Fabrication and testing of silver-hydrogen cells

Silver electrodes containing various additives were fabricated and tested in single electrode cells in order to improve the electrochemical utilization of sintered silver cathodes in Ag-H2 aerospace batteries. A standard stack arrangement was used which featured a NASA-developed organic-inorganic separator. All cells were cycled in a regime designed to remove 75% of the cells nominal capacity based on 3.3 gms/AHr Ag utilization. In cases where performance degradation was observed, the main feature mode appeared to be corrosion of either the expanded silver current collector or the connection between the silver electrode and the electrode tab. Promising silver electrodes from single electrode studies were used in the construction of 35 AHr Ag-H2 cells. Two such cells were constructed and installed in heavy walled pressure vessels for testing. Based on the data obtained from all cells tested during the program, four lightweight 35 AHr cells were fabricated. During acceptance testing these cells yielded an average gravimetric energy density of 30 WHr/1b.

Debicarri, D. J.↗

Excursion of vibrating microelectrodes in tissue

The paper deals with a vibrating microelectrode holder consisting of a support rod attached to the cone of a miniature loudspeaker. This holder facilitates a microelectrode penetration into arterial wall tissue, eliminates surface dimpling, and relieves polarographic artifacts believed to be due to tissue compression. The paper presents construction and performance details of the electrode holder, and evaluates the extent of possible damage incurred during such vibration by measuring electrode motion relative to surrounding tissue in an excised segment of femoral artery in the rabbit. It is concluded that under proper vibratory conditions microelectrodes can be easily inserted into the arterial wall with minimum tissue disturbance.

Kanabus, E. W.↗

Single-Layer, Multicolor Electroluminescent Phosphors

Etching eliminated in producing phosphor layers for displays. New process enables production of single-layer, two-color phosphor layer without etching. Method of construction, beginning with glass substrate with electrode and insulator layers, involves deposition of green phosphor masking with metal mask or photoresist; diffusion or ion implantation of manganese through mask to produce red phosphor and removal of mask.

Robertson, James B.↗

Characterization testing of a 40 Ahr bipolar nickel hydrogen battery

In a continuing effort to develop NiH2 bipolar technology to a point where it can be used efficiently in space flight, testing of a second 40 Ahr, 10-cell bipolar battery has begun. This battery has undergone extensive characterization testing to determine the effects of such operating parameters as charge and discharge rates, temperature, and pressure. The fundamental design of this actively cooled bipolar battery is the same as the first battery. Most of the individual components, however, are from different manufacturers. Different testing procedures as well as certain unique battery characteristics make it difficult to directly compare the two sets of results. In general, the performance of this battery throughout characterization produced expected results. The main differences seen between the first and second batteries occurred during the high-rate discharge portion of the test matrix. The first battery also had poor high-rate discharge results, although better than those of the second battery. Minor changes were made to the battery frame design used for the first battery in an attempt to allow better gas access to the reaction sites for the second build and hopefully improve performance. The changes, however, did not improve the performance of the second battery and could have possibly contributed to the poorer performance that was observed. There are other component differences that could have contributed to the poorer performance of the second battery. The H2 electrode in the second battery was constructed with a Goretex backing which could have limited the high-rate current flow. The gas screen in the second battery had a larger mesh which again could have limited the high-rate current flow. Small scale 2 x 2 batteries are being tested to evaluate the effects of the component variations.

Brewer, Jeffrey C.↗

A Survey of Alternative Oxygen Production Technologies

Utilization of the Martian atmosphere for the production of fuel and oxygen has been extensively studied. The baseline fuel production process is a Sabatier reactor, which produces methane and water from carbon dioxide and hydrogen. The oxygen produced from the electrolysis of the water is only half of that needed for methane-based rocket propellant, and additional oxygen is needed for breathing air, fuel cells and other energy sources. Zirconia electrolysis cells for the direct reduction of CO2 arc being developed as an alternative means of producing oxygen, but present many challenges for a large-scale oxygen production system. The very high operating temperatures and fragile nature of the cells coupled with fairly high operating voltages leave room for improvement. This paper will survey alternative oxygen production technologies, present data on operating characteristics, materials of construction, and some preliminary laboratory results on attempts to implement each. Our goal is to significantly improve upon the characteristics of proposed zirconia cells for oxygen production. To achieve that goal we are looking at electrolytic systems that operate at significantly lower temperatures, preferably below 31C to allow the incorporation of liquid CO2 in the electrolyte. Our preliminary results indicate that such a system will have much higher current densities and have simpler cathode construction than a porous gas feed electrode system. Such a system could be achieved based on nonaqueous electrolytes or ionic liquids. We are focusing our research on the anode reaction that will produce oxygen from a product generated at the cathode using CO2 as the feed. Operation at low temperatures also will open up the full range of polymer and metal materials, allowing a more robust system design to withstand the rigors of flight, landing, and long term unattended operation on the surface of Mars.

Lueck, Dale E.↗