Quasi-Dynamic Electromagnetic Field Safety Analysis and Mitigation for High-Power Dynamic Wireless Charging of Electric Vehicles

Dynamic wireless charging of electric vehicles (EV) is an emerging charging technology to enable non-contact wireless charging while the vehicle is moving. Compared to stationary wireless charging, in-motion wireless charging involves dynamic processes in which an EV is passing over the charging pads (transmitters). This in motion process makes the dynamic electromagnetic (EM) environment more complicated, and EM safety needs to be ensured under all circumstances. This is due to the fact that the entire vehicle body may be exposed to magnetic fields while the vehicle moves over the energized transmitter. This paper investigates several typical charging scenarios when EVs approach, pass over, and move away from the charging pads. Quasi-dynamic models, which are preliminarily verified by coils’ inductance measurements, are developed to analyze the dynamic process. Based on the quasi-dynamic analysis, shielding solutions are also studied to ensure EM safety for the dynamic wireless charging processes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Insights Into Thermal Runaway Mechanisms: Fast Tomography Analysis of Metal Agglomerates in Lithium-Ion Batteries

Thermal Runaway (TR) in lithium-ion batteries (LIB) is a critical technological and social concern. Whilst such events are rare, TR is characterized by uncontrollable heating leading to catastrophic failures. To deepen the understanding of the failure process and subsequently develop more accurate TR prediction models and as a result safer battery systems, we present in this work high-speed X-ray tomography for in-depth investigations of the copper current collector melting and agglomeration during TR. The melting process presents valuable real-time internal information about heat evolution during TR, previously challenging to access but crucially important for validating TR models. In this work, controlled failure studies combined with high-speed X-ray tomography were performed on two different commercial LIB models, subjecting them to both external heating and nail penetration to induce TR. Through real-time observation via high-speed tomography, followed by segmentation, rendering, and analysis, the formation of copper agglomerates was qualitatively and quantitatively characterized and visualized for the first time. Agglomerates tended to form either from the battery's outermost layers or centrally, depending on the method of TR initiation, and gives an indirect insight into the internal temperature evolution and distribution. Moreover, an initial comparative analysis between the battery models also revealed differences in agglomerate size, which has been linked to the thicker copper current collectors of one of the cell models. We further discuss the impact of larger copper agglomerates on heat distribution and safety. This study not only sheds light on the intricate dynamics of TR in LIBs but also underscores the pivotal role of 'gold-standard' imaging techniques in advancing battery safety, crucial for the robust modeling of TR and the future design of electric vehicle safety systems.

25 ENERGY STORAGE↗

Thermal aging effects on crosslinked polyethylene cable insulation with decabromodiphenyl ether flame retardant alternative

Decabromodiphenyl ether (decaBDE) has been extensively used as a flame retardant in several applications, including nuclear electrical cable insulation. However, decaBDE has been identified as a persistent, bioaccumulative and toxic (PBT) substance, leading to regulatory scrutiny. The Environmental Protection Agency (EPA) published a regulation on January 6, 2021, aimed at phasing out the manufacturing, processing, and distribution of decaBDE. This rule set a compliance deadline of March 8, 2021, for the manufacture and processing of decaBDE, and an extended deadline of January 6, 2023, for specific applications including wire and cable insulation in nuclear power generation facilities. In response to such regulations, RSCC, a major supplier of safety-related electrical cables and associated products to the U.S. nuclear industry updated the formula of their crosslinked polyethylene (XLPE) insulation to replace the historically used decaBDE flame retardant with an acceptable alternative. This change from the previous decaBDE-containing XLPE prompted interest in comparative performance of the two material formulations, especially with respect to characteristics relevant to safety-related function such as thermal and radiation resistance. RSCC graciously provided samples of wire insulated with the decaBDE-containing XLPE formulation and corresponding wire insulated with XLPE of the new formulation, containing a decaBDE alternative. In this work we compare characteristics of the two formulations and a previously produced commercial version of the RSCC decaBDE-containing XLPE insulation subjected to thermal aging at 150 °C and 165 °C. The comparison was focused on mechanical durability, thermal stability in the oxidative environment, and chemical structures. Briefly, • Tensile elongation at break (EAB) results showed loss of mechanical elasticity with longer aging time, as expected. Aging time dependence of EAB did not differ between the decaBDE-containing and decaBDE-alternative samples. • Subtle differences between the two materials can be detected from Fourier-transform infrared spectroscopy (FTIR) absorbance spectra in the range below 1700 cm -1 , are assumed to be related to decomposition of flame retardant additives during thermal aging. • The oxidation induction time (OIT) data seemed to show that the unaged decaBDE-containing XLPE material is more thermally stable than the unaged decaBDE-alternative material, but the discrepancy in OIT decreased with aging time and the OIT values of the two materials became similar starting with the 4 th day of aging at 165 °C. This thermal aging investigation confirmed that the mechanical durability, a key property monitored for cable qualification, was not significantly affected by the modification of the formulation with a decaBDE alternative flame-retardant system in the investigated thermal aging conditions. Further studies on the same sets of materials exposed to thermal and gamma radiation aging would further inform comparison of the materials safety-related function.

36 MATERIALS SCIENCE↗

National Fire Protection Association Spurs the Safe Adoption of EVs Through Education and Outreach

As electric vehicles (EV) and their charging infrastructure steadily increase in popularity across the U.S., growing pains still exist, impeding their true potential for growth. The barriers include a general lack of knowledge around EV systems, range anxiety, electrical workplace safety practices, code compliance and inspection for charging stations, maintenance garages and workers, insurance concerns, and the potential risks associated with damaged lithium-ion batteries (fires, re-ignition, water immersion, and stranded energy).NFPA partnered with SMEs, training development organizations, and Clean City Coalitions to create a series of common online trainings for each EV ecosystem sector, educating communities on the realities of EV proliferation, myths, facts, statistics, codes, and basic information for each sector to become versed in EV knowledge. We also constructed a workshop program for the many EV stakeholders who should be involved in setting up a strategic, cohesive outlook for the participating towns and cities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Current Status and Future Directions of All-Solid-State Batteries with Lithium Metal Anodes, Sulfide Electrolytes, and Layered Ternary Oxide Cathodes

All-solid-state batteries (ASSBs) offer great promise as a next-generation energy storage technology with higher energy density, wider operating temperature range, and improved safety for electric vehicles. ASSBs employing lithium metal anodes (Li), sulfide-based solid-state electrolytes (SSE), and Ni-rich layered transition metal oxide cathodes (LiMO 2 , M = Ni, Mn, Co, Al) are particularly promising due to its superior electrochemical performance compared to other solid-electrolyte systems. However, the battery cycle life at high cathode mass loading and high current is still limited because the failure mechanism is not fully understood. Lithium dendrite growth at the anode or inside a solid electrolyte still represents as a serious risk of cell failure. Interfacial resistance increases attributed to electrolyte decomposition and interfacial void formation at both cathode–electrolyte and anode–electrolyte interfaces lead to gradual capacity fading. In this Review, we present the fundamental challenges and recent scientific understandings of each component in ASSBs. The novel diagnostic tools for these components, especially the interfaces buried under the surface that are often hard for characterization are mainly examined. Lastly, we offer a perspective for future research directions. We hope this Review will provide a timely snapshot of state-of-the-art research progress in ASSBs to accelerate the development of ASSBs.

25 ENERGY STORAGE↗

Communication—Impact Behaviors of Pouch and Prismatic Battery Modules

The responses of pouch and prismatic battery modules when they are impacted by two types of indenters from three different directions are investigated experimentally. The test results show that the failure mechanism, peak force and penetration that leads to short-circuit in modules strongly depend on the impact direction, indenter shape, cell form factor and module design. It sheds lights on the abuse tolerance of batteries in different scenarios and demonstrates that the cell type, orientation and module structure should be considered simultaneously in order to improve the battery safety in electrical vehicles.

Electrochemistry↗

Precursor Analysis Report: SQL Slammer Worm Infection of Davis-Besse Nuclear Power Plant 2003

The SQL Slammer Worm Infection of Davis-Besse Nuclear Power Plant 2003 Precursor Analysis Report leverages publicly available information about Davis-Besse’s 2003 cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. On 25 January 2003, the SQL Slammer worm infected more than 90% of vulnerable hosts and crashed the internet in 10 to 15 minutes, making it one of the fastest spreading worms in history. SQL Slammer is a fileless, memory-resident worm that remotely exploits a stack-based buffer overflow vulnerability on local hosts to intensively scan and rapidly self-propagate across the internet. The worm infected approximately 300,000 unpatched hosts running Microsoft Structured Query Language (SQL) Server 2000 or Microsoft Desktop Engine (MSDE) 2000 with SQL Server Resolution Service. The SQL Slammer worm indirectly infected FirstEnergy’s Davis-Besse nuclear power plant by first infecting a consultant’s company network server and then propagating through an external misconfigured connection into Davis-Besse’s site network. The infection caused major network congestion, slow performance, data overloads, and the inability of local hosts to communicate with each other, which eventually caused a loss of availability and a loss of view when the Safety Parameter Display System (SPDS) and Plant Process Computer (PPC) crashed. At the time of the infection, the plant was already offline, the digital monitoring systems had redundant analog backups, and the plant control and safety functions were not affected, so there were no concerns of a safety breach. However, this incident resulted in many lessons learned and spawned important discussions about cybersecurity’s role in nuclear safety and electric power reliability regulation, policy, and guidance. Researchers and analysts identified 10 unique techniques utilized during the attack with a total of 640 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Eight of the identified techniques used during Davis-Besse cyber attack were precursors to the triggering event. Analysis identified 596 observables associated with these precursor techniques, 428 of which were assessed to have an increased likelihood of being perceived in the 331 days preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Exploring thermal runaway propagation in Li-ion batteries through high-speed X-ray imaging and thermal analysis: Impact of cell chemistry and electrical connections

Battery safety design is important to consider from the individual Li-ion cell to the level of the macro-system. On the macro-level, failure in one single cell can lead to propagation of the thermal runaway and rapidly set a whole battery pack on fire. Factors that can impact the propagation outcome, such as cell model/chemistry and electrical connection are here investigated using a combination of measurements. Several abusive tests were conducted, combining two different cell models (Molicel P42A and LG M50, both 21700s) in series and parallel connections (16 tests per configuration). Overall, a propagation outcome of 56% was measured from the 32 conducted tests, a minimum temperature of 150 °C was required to initiate propagation, and the fastest propagation occurred in 123 s. Temperature measurements were higher in series connected cells, initiating the discussion of cell chemistry and internal resistance on this effect. The difference in current-flow during thermal runaway in series and parallel connections, and how this can affect the temperature evolution is further discussed. Spatio-temporal mapping of X-ray radiography allowed us to derive the speed of thermal runaway evolution inside the battery and has shown that series connected cells, in particular P42A, occur faster. It was further observed that deviant sidewall behaviors such as temperature-induced breaches and pressure-induced ruptures occurred in P42As only respective nail-penetrated cells only.

25 ENERGY STORAGE↗

Accelerating Transitions to Zero Carbon Power Systems

As power systems evolve, becoming increasingly renewable, distributed, dynamic, and digital, managing them becomes ever more challenging and complex. System operators serve as the "air traffic controllers" for electricity grids, working to balance supply and demand, manage evolving electricity markets, and ensure the safety and reliability of electricity systems. To adapt to the rapidly changing energy landscape and support the transition to modern, zero carbon power systems, system operators must develop and adopt new technologies, approaches, and frameworks. The Global Power System Transformation (G-PST) Consortium is a network of system operators, research institutions, and industry partners working to accelerate and scale the technical solutions required to transform our world's power systems. By developing and sharing robust models and tools, research and demonstration results, knowledge, and innovation, the G-PST Consortium is empowering system operators to transition to 100% renewable energy while ensuring the reliability, safety, and cost-effectiveness of grid operations.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

Energy use of residential safety, security, and health devices

Miscellaneous electrical loads (MELs) are responsible for a significant fraction of energy consumption in buildings. This paper addresses one category of MELs: Safety, Security, and Health Devices (SSHDs). Common SSHDs include: electrical life safety equipment, smoke alarms, radon mitigation fans, and home oxygen concentrators. The installation or use of these devices is dictated by building codes, health providers, insurance companies, and other entities—none of which would ordinarily consider energy efficiency a priority. For this project, the most important residential devices were explored in terms of their governing regulations, functions, technologies, and energy use. The power consumption of 41 life safety SSHDs were measured. Individual power consumption of life safety devices is very small but many are typically required in every home. Devices performing the same functions have wide ranges in power use. Opportunities for reducing SSHD energy use were investigated, the results are summarized, and recommendations are made for further actions that could be taken to reduce SSHD energy use. Finally, SSHDs identified in this paper are responsible for at least one percent of current U.S. residential electricity consumption, but that number will climb steadily as existing buildings are upgraded and new types of SSHDs appear.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Safety Compliance Verification of Fuel Cell Electric Vehicle Exhaust

NREL has been developing compliance verification tools for allowable hydrogen levels prescribed by the Global Technical Regulation Number 13 (GTR-13) for hydrogen fuel cell electric vehicles (FCEVs). As per GTR-13, FCEV exhaust is to remain below 4 vol% H2 over a 3-second moving average and shall not at any time exceed 8 vol% H2 and that this requirement is to be verified with an analyzer that has a response time of less than 300 ms. To be enforceable, a means to verify regulatory requirements must exist. In response to this need, NREL developed a prototype analyzer that meets the GTR metrological requirements for FCEV exhaust analysis. The analyzer was tested on a commercial fuel cell electric vehicle (FCEV) under simulated driving conditions using a chassis dynamometer at the Emissions Research and Measurement Section of Environment and Climate Change Canada and FCEV exhaust was successfully profiled. Although the prototype FCEV Exhaust Analyzer met the metrological requirements of GTR-13, the stability of the hydrogen sensor was adversely impacted by condensed water in the sample gas. FCEV exhaust is at an elevated temperature and nearly saturated with water vapor. Furthermore, condensed water is present in the form of droplets. Condensed water in the sample gas can collect on the hydrogen sensing element, which would not only block access of hydrogen to the sensor but can also permanently damage the sensor. In the past year, the design of the gas sampling system was modified to mitigate against the transport of liquid water to the sensing element. Laboratory testing confirmed the effectiveness of the modified sampling system water removal strategy while maintaining the measurement range and response time required by GTR-13. Testing of the upgraded analyzer design on an FCEV operating on a chassis dynamometer is scheduled for the summer of 2021.

DIRECT ENERGY CONVERSION,HYDROGEN↗

Review of Safety and Exposure Limits of Electromagnetic Fields (EMF) in Wireless Electric Vehicle Charging (WEVC) Applications

This study reviews the exposure limits and safety of intermediate frequency (IF) electromagnetic field (EMF) emissions for wireless electric vehicle charging (WEVC) applications. A review of the electromagnetic field exposure limits identified in international guidelines are presented. An overview of the electromagnetic field shielding technologies is provided including recommended geometries, materials, and performances of the methods available in the literature. Available laboratory results of EMF emissions are summarized considering several wireless power transfer studies in different power levels. Possible EMF reduction techniques are discussed with shielding practices and ORNL case studies. Also, living object detection (LOD) and foreign object detection (FOD) methods are reviewed from a safety aspect.

Asa, Erdem↗

Safety and effectiveness of a non-electric infant warmer for hypothermia in Rwanda: A cluster-randomized stepped-wedge trial

Background: Neonatal hypothermia is a common source of morbidity and mortality in low resource settings. We developed the Dream Warmer, a low cost, re-usable non-electric infant warmer to prevent and treat hypothermia. Methods: We conducted a cluster-randomized stepped-wedge trial. The primary aim was to assess the effect on overall euthermia rates of introducing the warmer compared to standard of care in rural Rwandan hospitals. The secondary aims were to assess effects of warmer introduction on mortality, as well as the safety and feasibility of the warmer. Ten district hospitals participated in the study from November 19th 2019 to July 15th 2020. Patients were eligible to use the warmer if they were 1) hypothermic (temp < 36·5 °C) or 2) or at risk of hypothermia (weight < 2·5 kg or estimated post menstrual age < 35 weeks) when Kangaroo Mother Care was not available. An encounter was defined as the data from an individual infant on a single day. Trial of a Non Electric Infant Warmer for Prevention and Treatment of Hypothermia in Rwanda [NCT03890211]. Findings: Over the study period, 3179 patients were enrolled across the ten neonatal wards, yielding 12,748 encounters; 464 unique infants used the warmer 892 times, 79% eligible due to hypothermia. Because of limited study nurse resources, the warmer was used in only 18% of eligible encounters. Despite this low rate of warmer use, the rate of euthermia rose from 51% (95% CI 50–52%) of encounters pre-intervention to 67% (66–68%) post-intervention; p < 0·0001. Among the encounters in which the warmer was used, only 11% (9–13%) remained hypothermic. While mortality rates pre- and post-intervention did not change, mortality rate among those who used the warmer was significantly lower than among those who did not (0·9% vs 2·8%, p = 0·01). Use of the warmer did not affect hyperthermia rates. There were no safety concerns or instances of incorrect warmer use. Interpretation: Introduction of the warmer increased rates of euthermia with no associated safety concerns.

60 APPLIED LIFE SCIENCES↗

A 100-kW Wireless Power Transfer System Development Using Polyphase Electromagnetic Couplers

Wireless power transfer (WPT) is an essential technology enabling automated charging of electric vehicles with safety, convenience, and flexibility while having high efficiencies. High-power wireless charging systems will be one of the dominating charging technologies for electric vehicles (EVs) in an effort to eliminate range anxiety and reduce charging times similar to that of gas station refueling practice. Polyphase electromagnetic coupler with rotating fields is a new bipolar wireless charging pad technology that can significantly increase the surface power density (kW/m2) of wireless charging coils. This study proposes a 100-kW wireless power transfer system with a compact vehicle-side (receiver) coupler that reaches to about 0.905 MW/m2 surface power density with a transmitter rated for up to 300 kW with 0.68 MW/m2. High-frequency power electronics including the inverter and rectifier designs are included in this digest along with the hardware prototype developments and preliminary experimental results.

Onar, Omer↗

Arc Flash Evaluation Poster

Arc flash evaluation is a key aspect of assessing the safety of an electrical system. An arc flash occurs when a short circuit results in large amounts of unexpected current in a conductor leading to a massive release of energy. By conducting an arc flash evaluation engineers are able to design safer systems and determine the level of protective equipment that a worker needs to wear in order to survive an arc flash incident.

24 POWER TRANSMISSION AND DISTRIBUTION↗