Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electric load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Drive Train Normal Modes Analysis for the ERDA/NASA 100-Kilowatt Wind Turbine Generator

Natural frequencies, as a function of power were determined using a finite element model. Operating conditions investigated were operation with a resistive electrical load and operation synchronized to an electrical utility grid. The influence of certain drive train components on frequencies and mode shapes is shown. An approximate method for obtaining drive train natural frequencies is presented.

Sullivan, T. L.↗

Development of Electronic Load Controllers for Free-Piston Stirling Convertors Aided by Stirling Simulation Model

The free-piston Stirling convertor end-to-end modeling effort at the NASA Glenn Research Center has produced a software-based test bed in which free-piston Stirling convertors can be simulated and evaluated. The simulation model includes all the components of the convertor: the Stirling cycle engine, heat source, linear alternator, controller, and load. So far, it has been used in evaluating the performance of electronic controller designs. Three different controller design concepts were simulated using the model: 1) Controllers with parasitic direct current loading. 2) Controllers with parasitic alternating current loading. 3) Controllers that maintain a reference current. The free-piston Stirling convertor is an electromechanical device that operates at resonance. It is the function of the electronic load controller to ensure that the electrical load seen by the machine is always great enough to keep the amplitude of the piston and alternator oscillation at the rated value. This is done by regulating the load on the output bus. The controller monitors the instantaneous voltage, regulating it by switching loads called parasitic loads onto the bus whenever the bus voltage is too high and removing them whenever the voltage is too low. In the first type of controller, the monitor-ing and switching are done on the direct-current (dc) bus. In the second type, the alternating current bus is used. The model allows designers to test a controller concept before investing time in hardware. The simulation code used to develop the model also offers detailed models of digital and analog electronic components so that the resulting designs are realistic enough to translate directly into hardware circuits.

Regan, Timothy F.↗

Magnetostrictive Vibration Damper and Energy Harvester for Rotating Machinery

Vibrations generated by machine driveline components can cause excessive noise and structural damage. Magnetostrictive materials, including Galfenol (iron-gallium alloys) and Terfenol-D (terbium-iron-dysprosium alloys), are able to convert mechanical energy to magnetic energy. A magnetostrictive vibration ring is proposed, which generates electrical energy and dampens vibration, when installed in a machine driveline. A 2D axisymmetric finite element (FE) model incorporating magnetic, mechanical, and electrical dynamics is constructed in COMSOL Multiphysics. Based on the model, a parametric study considering magnetostrictive material geometry, pickup coil size, bias magnet strength, flux path design, and electrical load is conducted to maximize loss factor and average electrical output power. By connecting various resistive loads to the pickup coil, the maximum loss factors for Galfenol and Terfenol-D due to electrical energy loss are identified as 0.14 and 0.34, respectively. The maximum average electrical output power for Galfenol and Terfenol-D is 0.21 W and 0.58 W, respectively. The loss factors for Galfenol and Terfenol-D are increased to 0.59 and 1.83, respectively, by using an L-C resonant circuit.

Magnetostrictive↗

Impedance Measurements of Motor Drives and Supply in SPEED Testbed

Many electrified aircraft configurations consist of a number of power components operating on the same shared electrical bus. Understanding the impedance performance of electrical loads and sources is key to understanding, and designing for, acceptable overall vehicle power quality and power system stability. To enable these measurements, personnel at NASA’s Glenn research Center have designed and built the Scaled Power ElEctrified Drivetrain (SPEED) Testbed. This paper will present data taken in the SPEED lab, including impedance measurements of a DC supply (source) and a motor drive and electric machine (load) under a number of conditions. Impacts of load power, drive controller tuning, and field weakening on load impedance are measured, presented, and discussed; as are source impedance data, and DC bus current spectra at different loading levels.

electrified aircraft propulsion↗

Impedance Measurements of Motor Drive and Supply in SPEED Testbed

Many electrified aircraft configurations consist of a number of power components operating on the same shared electrical bus. Understanding the impedance performance of electrical loads and sources is key to understanding, and designing for, acceptable overall vehicle power quality and power system stability. To enable these measurements, personnel at NASA’s Glenn Research Center have designed and built the Scaled Power ElEctrified Drivetrain (SPEED) Testbed. This paper will present data taken in the SPEED lab, including impedance measurements of a DC supply (source) and a motor drive and electric machine (load) under a number of conditions. Impacts of load power, drive controller tuning, and field-weakening on load impedance are measured, presented, and discussed; as are source impedance data, stability, and DC bus current spectra at different loading levels.

electrified aircraft propulsion↗

High-Energy-Density Electrolytic Capacitors

Reductions in weight and volume make new application possible. Supercapacitors and improved ultracapacitors advanced electrolytic capacitors developed for use as electric-load-leveling devices in such applications as electric vehicle propulsion systems, portable power tools, and low-voltage pulsed power supplies. One primary advantage: offer power densities much higher than storage batteries. Capacitors used in pulse mode, with short charge and discharge times. Derived from commercially available ultracapacitors. Made of lightweight materials; incorporate electrode/electrolyte material systems capable of operation at voltages higher than previous electrode/electrolyte systems. By use of innovative designs and manufacturing processes, made in wide range of rated capacitances and in rated operating potentials ranging from few to several hundred volts.

Yen, Shiao-Ping S.↗

Impedance Measurements of Motor Drives and Supplies in NASA NEAT Facility

Many electrified aircraft configurations consist of a number of power components operating on the same shared electrical bus. Understanding the impedance performance of electrical loads and sources is key to understanding, and designing for, acceptable overall vehicle power quality and power system stability. This paper discusses impedance measurements made on the NASA Electric Aircraft Testbed (NEAT) Electrical Power System (EPS) at NASA Glenn Research Center. First, an overall discussion of the NEAT facility configuration during testing is presented; then details of the impedance measurement approach and the various testing configurations are discussed. Next, input impedance measurements at NEAT, including sources (DC supplies) and loads (multiple motor drives, electric machines, and resistive load banks, with long interconnecting cable leads), are performed under a number of conditions, and results, including load model comparisons and stability analysis, are presented and discussed.

electrified aircraft propulsion↗

Impedance Measurements of Motor Drives and Supplies in NASA NEAT Facility

Many electrified aircraft configurations consist of a number of power components operating on the same shared electrical bus. Understanding the impedance performance of electrical loads and sources is key to understanding, and designing for, acceptable overall vehicle power quality and power system stability. This paper discusses impedance measurements made on the NASA Electric Aircraft Testbed (NEAT) Electrical Power System (EPS) at NASA Glenn Research Center. First, an overall discussion of the NEAT facility configuration during testing is presented. Then, details of the impedance measurement approach and the various testing configurations are discussed. Next, input impedance measurements at NEAT, including sources (DC supplies) and loads (multiple motor drives, electric machines, and resistive load banks, with long interconnecting cable leads), are performed under a number of conditions, and results, including load model comparisons and stability analysis, are presented and discussed.

electrified aircraft propulsion↗

Practical aspects of photovoltaic technology, applications and cost (revised)

The purpose of this text is to provide the reader with the background, understanding, and computational tools needed to master the practical aspects of photovoltaic (PV) technology, application, and cost. The focus is on stand-alone, silicon solar cell, flat-plate systems in the range of 1 to 25 kWh/day output. Technology topics covered include operation and performance of each of the major system components (e.g., modules, array, battery, regulators, controls, and instrumentation), safety, installation, operation and maintenance, and electrical loads. Application experience and trends are presented. Indices of electrical service performance - reliability, availability, and voltage control - are discussed, and the known service performance of central station electric grid, diesel-generator, and PV stand-alone systems are compared. PV system sizing methods are reviewed and compared, and a procedure for rapid sizing is described and illustrated by the use of several sample cases. The rapid sizing procedure yields an array and battery size that corresponds to a minimum cost system for a given load requirement, insulation condition, and desired level of service performance. PV system capital cost and levelized energy cost are derived as functions of service performance and insulation. Estimates of future trends in PV system costs are made.

Rosenblum, L.↗

MHD channel performance for potential early commercial MHD power plants

The commercial viability of full and part load early commercial MHD power plants is examined. The load conditions comprise a mass flow of 472 kg/sec in the channel, Rosebud coal, 34% by volume oxygen in the oxidizer preheated to 922 K, and a one percent by mass seeding with K. The full load condition is discussed in terms of a combined cycle plant with optimized electrical output by the MHD channel. Various electrical load parameters, pressure ratios, and magnetic field profiles are considered for a baseload MHD generator, with a finding that a decelerating flow rate yields slightly higher electrical output than a constant flow rate. Nominal and part load conditions are explored, with a reduced gas mass flow rate and an enriched oxygen content. An enthalpy extraction of 24.6% and an isentropic efficiency of 74.2% is predicted for nominal operation of a 526 MWe MHD generator, with higher efficiencies for part load operation.

Swallom, D. W.↗

Electric fields and conductivity in the nighttime E-region - A new magnetosphere-ionosphere-atmosphere coupling effect

Calculations have been made of the effects of intense poleward-directed electric fields upon the nighttime ionospheric E-region. The results show the Pedersen and Hall conductivities are substantially changed, thereby decreasing the ionospheric electrical load seen by magnetospheric sources. It appears that relatively large electric fields can exist in the absence of accompanying large field-aligned currents, as long as the underlying ionosphere remains in darkness and/or energetic particle precipitation is absent.

Banks, P. M.↗

Dynamic load simulator

Concepts and techniques for identifying and simulating both the steady state and dynamic characteristics of electrical loads for use during integrated system test and evaluation are discussed. The investigations showed that it is feasible to design and develop interrogation and simulation equipment to perform the desired functions. During the evaluation, actual spacecraft loads were interrogated by stimulating the loads with their normal input voltage and measuring the resultant voltage and current time histories. Elements of the circuits were optimized by an iterative process of selecting element values and comparing the time-domain response of the model with those obtained from the real equipment during interrogation.

Joncas, K. P.↗

Spacecraft power system architecture to mitigate spacecraft charging effects

A power system architecture for a spacecraft and a method of a power supply for a spacecraft are presented which take advantage of the reduced plasma interaction associated with positive ground high voltage photovoltaic arrays and provide a negative ground power supply for electrical loads of the spacecraft. They efficiently convert and regulate power to the load bus and reduce power system mass and complexity. The system and method ground the positive terminal of the solar arrays to the spacecraft hull, and using a power converter to invert the electric sign, permit a negative ground for the electrical distribution bus and electrical components. A number of variations including a load management system and a battery management system having charging and recharging devices are presented.

Manner, David B.↗

A free-piston Stirling engine/linear alternator controls and load interaction test facility

A test facility at LeRC was assembled for evaluating free-piston Stirling engine/linear alternator control options, and interaction with various electrical loads. This facility is based on a 'SPIKE' engine/alternator. The engine/alternator, a multi-purpose load system, a digital computer based load and facility control, and a data acquisition system with both steady-periodic and transient capability are described. Preliminary steady-periodic results are included for several operating modes of a digital AC parasitic load control. Preliminary results on the transient response to switching a resistive AC user load are discussed.

Rauch, Jeffrey S.↗

A free-piston Stirling engine/linear alternator controls and load interaction test facility

A test facility at LeRC was assembled for evaluating free-piston Stirling engine/linear alternator control options, and interaction with various electrical loads. This facility is based on a 'SPIKE' engine/alternator. The engine/alternator, a multi-purpose load system, a digital computer based load and facility control, and a data acquisition system with both steady-periodic and transient capability are described. Preliminary steady-periodic results are included for several operating modes of a digital AC parasitic load control. Preliminary results on the transient response to switching a resistive AC user load are discussed.

Rauch, Jeffrey S.↗

Static and dynamic strain energy release rates in toughened thermosetting composite laminates

In this work, the static and dynamic fracture properties of several thermosetting resin based composite laminates are presented. Two classes of materials are explored. These are homogeneous, thermosetting resins and toughened, multi-phase, thermosetting resin systems. Multi-phase resin materials have shown enhancement over homogenous materials with respect to damage resistance. The development of new dynamic tests are presented for composite laminates based on Width Tapered Double Cantilevered Beam (WTDCB) for Mode 1 fracture and the End Notched Flexure (ENF) specimen. The WTDCB sample was loaded via a low inertia, pneumatic cylinder to produce rapid cross-head displacements. A high rate, piezo-electric load cell and an accelerometer were mounted on the specimen. A digital oscilloscope was used for data acquisition. Typical static and dynamic load versus displacement plots are presented. The ENF specimen was impacted in three point bending with an instrumented impact tower. Fracture initiation and propagation energies under static and dynamic conditions were determined analytically and experimentally. The test results for Mode 1 fracture are relatively insensitive to strain rate effects for the laminates tested in this study. The test results from Mode 2 fracture indicate that the toughened systems provide superior fracture initiation and higher resistance to propagation under dynamic conditions. While the static fracture properties of the homogeneous systems may be relatively high, the apparent Mode 2 dynamic critical strain energy release rate drops significantly. The results indicate that static Mode 2 fracture testing is inadequate for determining the fracture performance of composite structures subjected to conditions such as low velocity impact. A good correlation between the basic Mode 2 dynamic fracture properties and the performance is a combined material/structural Compression After Impact (CAI) test is found. These results underscore the importance of examining rate-dependent behavior for determining the longevity of structures manufactured from composite materials.

Cairns, Douglas S.↗

High-Power Piezoelectric Acoustic-Electric Power Feedthru for Metal Walls

Piezoelectric acoustic-electric power feed-through devices transfer electric power wirelessly through a solid wall by using acoustic waves. This approach allows for the removal of holes through structures. The technology is applicable to power supply for electric equipment inside sealed containers, vacuum or pressure vessels, etc where the holes on the wall are prohibitive or result in significant performance degrade or complex designs. In the author's previous work, 100-W electric power was transferred through a metal wall by a small, simple-structure piezoelectric device. To meet requirements of higher power applications, the feasibility to transfer kilowatts level power was investigated. Pre-stressed longitudinal piezoelectric feedthru devices were analyzed by finite element model. An equivalent circuit model was developed to predict the power transfer characteristics to different electric loads. Based on the analysis results, a prototype device was designed, fabricated and a demonstration of the transmission of electric power up to 1-kW was successfully conducted. The methods to minimize the plate wave excitation on the wall were also analyzed. Both model analysis and experimental results are presented in detail in this presentation.

acoustic wave↗

1KW Power Transmission Using Wireless Acoustic-Electric Feed-Through (WAEF)

A variety of space applications require the delivery of power into sealed structures. Since the structural integrity can be degraded by holes for cabling we present an alternative method of delivering power and information using stress waves to the internal space of a sealed structure. One particular application of this technology is in sample return missions where it is critical to preserve the sample integrity and to prevent earth contamination. Therefore, the container has to be hermetically sealed and the integrity of the seal must be monitored in order to insure to a high degree of reliability the integrity of the sample return vessel. In this study we investigated the use of piezoelectric acoustic-electric power feed-through devices to transfer electric power wirelessly through a solid wall by using elastic or acoustic waves. The technology is applicable to a range of space and terrestrial applications where power is required by electronic equipment inside sealed containers, vacuum or pressure vessels, etc., where holes in the wall are prohibitive or may result in significant structural performance degradation or unnecessarily complex designs. To meet requirements of higher power applications, the feasibility to transfer kilowatts level power was investigated. Pre-stressed longitudinal piezoelectric feed-through devices were analyzed by finite element models and an equivalent circuit model was developed to predict the power transfer characteristics to different electric loads. Based on the results of the analysis a prototype device was designed, fabricated and a demonstration of the transmission of electric power up to 1.068-kW was successfully conducted. Efficiencies in the 80-90% range were also demonstrated and methods to increase the efficiency further are currently being considered.

pressure vessels↗