Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dynamometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

NASA project 1: Full-body dynamometer

In space, where the body does only a fraction of work it does on earth, muscle atrophy is a major concern. The bones and the muscles will begin to deteriorate after a short stay in weightlessness. Bone decalcification appears to be a major problem with extensive living in microgravity. Resistance exercise is not only essential to prevent muscle atrophy in space, it also helps to keep bone decalcification in check. For a space station, where the astronauts are expected to live for months at a time, exercise is especially important. Experts recommend about an hour and a half to two hours of exercise per day to keep the muscles in good condition in microgravity. The exercises will not only keep the astronauts in excellent physical condition, it will also make it easier for them to readjust to earth's gravity on return. The stationary bicycle and the treadmill have been the astronauts' primary sources of exercise since the 1970's. The major problem with both the stationary bicycle and the treadmill is that while they may keep the leg muscles from deteriorating in microgravity, they do little for muscles in the upper body. The National Aeronautics and Space Administration (NASA) is currently developing a full-body dynamometer (FBD), which will provide the astronauts with a full-body workout. It will also test the astronauts for muscle atrophy and rehabilitate the weakened muscle. The specification and the function structure for the FBD is presented.

Lu, Li-Dai↗

Evaluation of Suited and Unsuited Human Functional Strength Using Multipurpose, Multiaxial Isokinetic Dynamometer

The objective of the planned summer research was to develop a procedure to determine the isokinetic functional strength of suited and unsuited participants in order to estimate the coefficient of micro-gravity suit on human strength. To accomplish this objective, the Anthropometry and Biomechanics Facility's Multipurpose, Multiaxial Isokinetic dynamometer (MMID) was used. Development of procedure involved selection and testing of seven routines to be tested on MMID. We conducted the related experiments and collected the data for 12 participants. In addition to the above objective, we developed a procedure to assess the fatiguing characteristics of suited and unsuited participants using EMG technique. We collected EMG data on 10 participants while performing a programmed routing on MMID. EMG data along with information on the exerted forces, effector speed, number of repetitions, and duration of each routine were recorded for further analysis. Finally, gathering and tabulation Of data for various human strengths for updating of MSIS (HSIS) strength requirement, which started in summer 2003, also continued.

Aghazadeh, Fred↗

A Ground-Based Comparison of the Muscle Atrophy Research and Exercise System (MARES) and a Standard Isokinetic Dynamometer

PURPOSE: 1) To compare the test-to-test reliability of Muscle Atrophy Research and Exercise System (MARES) with a standard laboratory isokinetic dynamometer (ISOK DYN) and; 2) to determine if measures of peak torque and total work differ between devices. METHODS: Ten subjects (6M, 4F) completed two trials on both MARES and an ISOK DYN in a counterbalanced order. Peak torque values at 60 deg & 180 deg / s were obtained from five maximal repetitions of knee extension (KE) and knee flexion (KF). Total work at 180 deg / s was determined from the area under the torque vs. displacement curve during twenty maximal repetitions of KE and KF. Reliability of measures within devices was interpreted from the intraclass correlation coefficient (ICC) and compared between devices using the ratio of the within-device standard deviations. Indicators of agreement for the two devices were evaluated from: 1) a calculation of concordance (rho) and; 2) the correlation between the mean of measures versus the delta difference between measures (m u vs delta). RESULTS: For all outcome measures ICCs were high for both the ISOK DYN (0.95-0.99) and MARES (0.90-0.99). However, ratios of the within-device standard deviation were 1.3 to 4.3 times higher on MARES. On average, a wide range (3.3 to 1054 Nm) of differences existed between the values obtained. Only KE peak torque measured at 60 deg & 180 deg / s showed similarities between devices (rho = 0.91 & 0.87; Pearson's r for m u vs delta = -0.22 & -0.37, respectively). CONCLUSION: Although MARES was designed for use in microgravity it was quite reliable during ground-based testing. However, MARES was consistently more variable than an ISOK DYN. Future longitudinal studies evaluating a change in isokinetic peak torque or total work should be limited within one device.

Hackney, K. J.↗

Evaluation of some candidate materials for automobile thermal reactors in engine-dynamometer screening tests

Fourteen materials were evaluated in engine screening tests on full-size thermal reactors for automobile engine pollution control systems. Cyclic test-stand engine operation provided 2 hours at 1040 C and a 20-minute air-cool to 70 C each test cycle. Each reactor material was exposed to 83 cycles in 200 hours of engine testing. On the basis of resistance to oxidation and distortion, the best materials included two ferritic iron alloys (Ge 1541 and Armco 18S/R), several commercial oxidation-resistant coatings on AlSl 651 (19-9 DL), and possibly uncoated AISI 310. The best commercial coatings were Cr-Al, Ni-Cr, and a glass ceramic.

Oldrieve, R. E.↗

Analysis of internal flow characteristics of a smooth-disk water-brake dynamometer

The principal of absorbing power with an enclosed partially submerged rotating disk through the turbulent viscous shearing of water is discussed. Reference information is used to develop a flow model of the water brake. A method is then presented that uses vector diagrams to relate the effects of rotational flow, through flow, and secondary flow to power absorption. The method is used to describe the operating characteristics of an example 111-cm (43.7-in.) diameter water brake. Correlating performance parameters are developed in a dimensional analysis.

Evans, D. G.↗

Test-Bench Dynamometer

Test bench confirms operating characteristics of motors and drive mechanisms.

Perkins, G. S.↗

The DOE ETV-1 Electric Test Vehicle. Phase 3: Performance Testing and system evaluation

Engineering tests were conducted in order to characterize overall system performance and component efficiencies within the system environment. A dynamometer was used in order to minimize the ambient effects and large uncertainties present in track testing. Extensive test requirements were defined and procedures were carefully controlled in order to maintain a high degree of credibility. Limited track testing was performed in order to corroborate the dynamometer results. Test results include an energy flow analysis through the major subsystems and incorporate the aerodynamic and rolling losses under cyclic and various steady speed conditions. The major output from all relevant dynamometer and track tests is also included.

Kurtz, D.↗

The electrodynamometric balance of the small wind tunnel of the French Service of Aeronautical Research

This investigation shows the attempt to improve the electrodynamomoter designed by Mr. Villey. The force to be measured acts on a flexible steel plate which is placed in front of a fixed plate. The deformation varies the original thickness of the layer of air between the two plates, thus causing a more rapid variation in the coefficient of electrostatic attraction of the two plates than in the capacity of the condenser formed by the dynamometer. The measurements are made by a differential method. The capacity of the test dynamometer is compared with that of a similar instrument of constant capacity, this comparison being made by means of an electrometer. Diagrams are shown of the dynamometer, the electrometer, and the electrical connections.

Rebuffet, P↗

Exploratory evaluation of ceramics for automobile thermal reactors

An exploratory evaluation of ceramics for automobile thermal reactors was conducted. Potential ceramic materials were evaluated in several reactor designs using both engine dynamometer and vehicle road tests. Silicon carbide contained in a corrugated metal support structure exhibited the best performance lasting over 800 hours in engine dynamometer tests and over 15,000 miles (24,200 km) of vehicle road tests. Reactors containing glass-ceramic components did not perform as well as silicon carbide. But the glass-ceramics still offer good potential for reactor use. The results of this study are considered to be a reasonable demonstration of the potential use of ceramics in thermal reactors.

Stone, P. L.↗

Foot pedal operated fluid type exercising device

A foot pedal operated exercising device is reported that contains a dynamometer formed of a pair of cylinders each containing a piston. The pistons are linked to each other. The upper portions of the two cylinders are joined together by a common opening to provide a common fluid reservoir and each piston is provided with a one way check valve to maintain an adequate supply of working fluid. Fluid from the driven cylinder is transmitted to the other cylinder through separate constant force spring biased valves each valve takes the predominant portion of the pressure drop thereby providing a constant force hydraulic dynamometer. A device is provided to determine the amount of movement of piston travel.

Crum, G. W.↗