Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dynamics testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Comparison of animal and human blood for in vitro dynamic thrombogenicity testing of biomaterials

Abstract Background To determine suitable alternatives to human blood for in vitro dynamic thrombogenicity testing of biomaterials, four different animal blood sources (ovine, bovine, and porcine blood from live donors, and abattoir porcine blood) were compared to fresh human blood. Methods To account for blood coagulability differences between individual donors and species, each blood pool was heparinized to a donor‐specific concentration immediately before testing in a dynamic flow loop system. The target heparin level was established using a static thrombosis pre‐test. For dynamic testing, whole blood was recirculated at room temperature for 1 h at 200 ml/min through a flow loop containing a single test material. Four materials with varying thrombotic potentials were investigated: latex (positive control), polytetrafluoroethylene (PTFE) (negative control), silicone (intermediate thrombotic potential), and high‐density polyethylene (HDPE) (historically thromboresistant). Thrombus weight and surface area coverage on the test materials were quantified, along with platelet count reduction in the blood. Results While donor‐specific heparin levels varied substantially from 0.6 U/ml to 7.0 U/ml among the different blood sources, each source was able to differentiate between the thrombogenic latex and the thromboresistant PTFE and HDPE materials ( p < 0.05). However, only donor ovine and bovine blood were sensitive enough to differentiate an increased response for the intermediate thrombotic silicone material compared to PTFE and HDPE. Conclusions These results demonstrated that multiple animal blood sources (particularly donor ovine and bovine blood) may be suitable alternatives to fresh human blood for dynamic thrombogenicity testing when appropriate control materials and donor‐specific anticoagulation levels are used.

Engineering↗

Data of High-Temperature Dynamic LCM Testing Setup

Data from high temperature dynamic sealing tests for various fracture widths, at various temperatures (degrees F), with 5 wt.% bentonite-based mud containing various material fiber contents, at 100 to 400 psi differential pressure. Data from pressure test and evaluation of the dynamic lost circulation materials (LCM) testing unit to reflect the condition of open and sealed fracture using fracture width of 1000 microns at 120 degrees F. Links to two papers based on the data - "Loss circulation prevention in geothermal drilling by shape memory polymer" which was published in Geothermics 89 (2021) 101943) as well as "Evaluating sealability of blended smart polymer and fiber additive for geothermal drilling with the effect of fracture opening size", published in the Journal of Petroleum Science and Engineering 206 (2021) 108998.

15 GEOTHERMAL ENERGY↗

Dynamic response of a freely rotating butterfly valve in the advanced test reactor − dynamic coefficients modeling

Here, in evaluating the water hammer issue pertaining to the primary-coolant-regulating butterfly valve in the Advanced Test Reactor, the dynamic fluid body interaction (DFBI) approach was implemented in the analysis covered in Part I. Although DFBI modeling accurately and simultaneously solved the dynamic motion of the valve’s disk along with the flow field of the surrounding fluid, it shed little light on the reason behind such motion. For Part II, the reacting torque of the fluid on the disk was decomposed into representations of the dynamic coefficients in terms of stiffness, damping, and added mass. These were evaluated via simulations with steady-state static (stiffness), constant angular speed (damping), and variable angular speed (added mass) disks. Substituting the dynamic coefficients into Newton’s second law enabled the response trajectories to be obtained. Stable (by average) and unstable equilibrium positions and thrust tendencies of the valve were determined based on the stiffness coefficient (or static torque), the response amplitude was dampened or enlarged by the damping coefficient (minorly affected by added mass), and the response frequency was altered by the damping and added mass coefficients. Although the dynamic coefficient approach renders slightly different trajectories, due to the averaging effect of the torque in comparison to the DFBI method, the overall trend of the response aligns with the DFBI simulation, thus confirming the conclusion in Part I that a fix to the current butterfly valve is necessary.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Dynamic response of a freely rotating butterfly valve in the advanced test reactor – dynamic fluid-body interaction modeling

To regulate primary coolant flow in the Advanced Test Reactor (ATR), a butterfly valve was installed between the primary coolant pumps and the reactor core. If the mechanical connection between the valve's disk and its shaft ever fails, the disk will rotate freely. Rapid disk rotation may induce pressure surges that could damage upstream pipes. In the present work, the rotational trajectory and pressure evolution during a disk free-rotation scenario were analyzed via the dynamic fluid-body interaction (DFBI) approach in STAR-CCM+, with the movement of a solid being driven by the forces and moment/torque imposed by its surrounding fluid. Assuming a large initial opening angle, the disk accelerates slowly, but swiftly passes the closed position. As a result of the sudden valve closure, a pressure surge occurs in the upstream pipes, exceeding their maximum allowable pressure. Furthermore, the disk does not stabilize at the closed position but continually oscillates due to the unsteady nature of the coolant flow. Because of the significant and continuous water hammer effect, a fix to the butterfly valve is being implemented to prevent rapid valve closure due to failure at the valve's disk/shaft mechanical connection.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Semi-Dynamic Leach Testing of Densified Silicon-based Iodine Waste Forms

Iodine waste forms (IWF) require a conceptual corrosion release model (CCRM) to provide iodine (I) release rates for performance modeling nuclear waste disposal repositories. To develop a CCRM, an understanding of the corrosion mechanisms of the IWF are required along with data from consistent test methods to parameterize the model. The present study has advanced both areas by providing and assessing the corrosion resistance of IWF types based on their processing history in minor variations of semi-dynamic leach tests. The test included a series of semi-dynamic leach tests using monolithic IWFs in deionized water (leachant). Several experiments were conducted under alternate test conditions with changes to temperature, leachant replacement, leachant pH, leachant volume, masking, and surface finish to elucidate if varying these conditions impacted IWF corrosion behavior. Tests were conducted on two classes of IWFs: (1) I-bearing silver-mordenite (AgZ) materials processed by hot isostatic pressing (HIP) at different temperatures, pressures, sizes, and times; and (2) I-bearing silver-functionalized silica aerogels (SFA) processed by either HIP or spark plasma sintering (SPS). The corrosion susceptibility of AgZ samples was influenced by HIP temperature and pressure. The SPS SFAs retained I far better than HIP SFAs. Additional findings in this study include: (1) The iodine dissolution rate decreased with decreasing temperature, (2) a common ion effect may occur and slow dissolution of the host phase if the leachant is not regularly replaced, (3) pH controls the dissolution rate, and (4) the iodine dissolution rate slows with extended test time (up to 224 days). Based on this work, these parameters should thus be represented when developing a CCRM.

corrosion↗

Review and Experimental Comparison of the Durability of Iodine Waste Forms in Semi-Dynamic Leach Testing

To ensure the safe disposal of radioiodine-containing nuclear wastes, a durable iodine waste form (IWF) is required. Many IWFs have been developed and evaluated for chemical durability using a wide range of test methods, making direct comparisons difficult as highlighted in this work through a review of available IWF corrosion data. To move toward a common dataset, a semi-dynamic leach test suite was experimentally demonstrated using several IWF types, providing standard comparisons. The results highlighted clear differences in corrosion resistance between various IWFs. This test suite is suggested for future studies to generate comparable data for a common dataset.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating Fracture Behavior of Bioinspired Alumina-YSZ Composites through Static and Dynamic Mechanical Testing

Ceramic materials are known for their high hardness and strength but are limited by low toughness and sudden failure. Inspired by the microstructure of dental enamel, which features undulating rods that promote crack deflection and energy absorption, architected specimens were designed and manufactured. A bespoke ball-on-ring (BoR) testing apparatus measured the static biaxial rupture strength of these bioinspired materials. Additionally, impact testing with spherical steel projectiles assessed their behavior under dynamic conditions. Monolithic alumina specimens were compared to architected alumina reinforced with yttria-stabilized zirconia (YSZ) rods produced via direct ink write 3D printing. BoR tests revealed that monolithic alumina had a Weibull modulus of 10.53 and a characteristic strength of 372.3 MPa, while the composite specimens showed a Weibull modulus of 5.46 and a characteristic strength of 213.3 MPa. Although the composite failed at lower stresses and projectile velocities, it exhibited notable crack deflection and fracture resistance, with cracks being effectively interrupted by the rod inclusions. The composite specimens also resulted in fewer and larger fragments upon impact. Finite element simulations confirmed the effectiveness of the rod structures in enhancing fracture resistance.

Bioinspired materials↗

Experimental Verification of Pulse Shaping in Elastic Metamaterials Under Impact Excitation

Here, we present experimental verification of pulse shaping in elastic metamaterials together with a procedure to design, fabricate, and verify metamaterial pulse shapers under impact excitation. The split Hopkinson pressure bar (SHPB) test, a fundamental dynamic test introduced more than 70 years ago, often incorporates pulse shaping as a means to alter a stress wave, providing the primary motivation for the presented study. Elastic metamaterials hold promise for enhancing conventional pulse shaping abilities and improving capabilities of the SHPB test. We first design the pulse shaper by numerically optimizing its response using finite element analysis. The pulse shaper consists of repeated unit cells based on a combination of a phononic crystal and a local resonator. Then, we fabricate and test pulse shaper candidates to validate the procedural efficacy. An iterative element corrects inaccuracies in input force and material properties and allows convergence on an appropriate pulse shaper. We carry out this procedure by designing pulse shapers fabricated from 3D-printed polylactic acid (PLA) to achieve an extended dwell acceleration pulse shape. In experimental impact tests, the procedure results in rise, dwell, and fall behaviors comparable to that predicted, effectively confirming the efficacy of the presented procedure and verifying the performance of metamaterial-based pulse shapers.

36 MATERIALS SCIENCE↗

Testing, Characterization, and Modeling of the Resonant Plate Test Environment

The resonant plate shock test is a dynamic test of a mid-field pyroshock environment where a projectile is struck against a plate. The structure undergoing the simulated field shock is mounted to the plate. The plate resonates when struck and provides a two sided shock that is representative of the shock observed in the field. This test environment shock simulates a shock in a single coordinate direction for components looking to provide evidence that they will survive a similar or less shock when deployed in their operating environment. However, testing in one axis at a time provides many challenges. The true environment is a multi-axis environment. The test environment exhibits strong off-axis motion when only motion in one axis is desired. Multiple fixtures are needed for a single test series. It would be advantageous if a single test could be developed that tests the multi-axis environment simultaneously. In order to design such a test, a model must be developed and validated. The model can be iterated in design and configuration until the specified multi-axis environment is met. The test can then execute the model driven test design. This report discusses the resonant plate model needed to design future tests and the steps and methods used to obtain the model. This report also details aspects of the resonant plate test discovered during the process of model development that aids in our understanding of the test.

42 ENGINEERING↗

Identification of Dynamic Force Coefficients for an Additively Manufactured Hermetic Squeeze Film Bearing Support Damper Utilizing a Pass-Through Channel

Abstract The following paper presents breakthrough experimental results for a new hermetic squeeze film damper (HSFD) concept that is integrally designed within an externally pressurized tilting-pad radial gas bearing support. The flexibly damped gas bearing module was designed for a 7.2″ (183 mm) diameter shaft and fabricated using direct metal laser melting (DMLM); also known as additive manufacturing. The bearing and HSFD were sized based on ongoing studies for oil-free supercritical carbon dioxide (sCO2) power turbines in the 8.5 MW–10 MW power range. The development of the new damper concept was motivated by past dynamic testing on HSFD, which generated frequency-dependent stiffness and damping force coefficients. In efforts to eliminate the frequency dependency, a new HSFD architecture was conceived that adds accumulator volumes and a pass-through channel to previously conceived HSFD flow network designs. The other motivation for the work is the need to develop a cost-effective and reliable oil-free bearing technology that is scalable to large power turbomachinery applications. There were several objectives for the following work. The first objective was to successfully design and fabricate a single piece bearing-damper using additive manufacturing, while dimensionally controlling critical design features. The paper discusses the manufacturing steps and shows cut-ups that reveal adequate clearance control capability with internal damper clearances. The second objective was to perform experimental testing with the new HSFD design in efforts to extract stiffness and damping coefficients for excitation frequencies within 20–160 Hz and peak vibration amplitudes between 0.25 mils (6.35 microns) to 1 mil (25.4 microns). The test results for a single HSFD bearing module indicated that the design modifications to the HSFD architecture were successful in eliminating nearly all the frequency dependencies for the stiffness force coefficient. The dynamic tests yielded a stiffness coefficient that varied between 112 klb/in. (19.6 MN/m) and 96 klb/in. (16.8 MN/m). The damping force coefficient however, exhibited relatively more variation with frequency with values residing between 175 lb-s/in. (31 kN-s/m) to 214 lb-s/in. (37 kN-s/m). Finally, the paper advances a three-dimensional fluid-structure interaction (FSI) model using transient finite element analysis (FEA) coupled to a computational fluid dynamics (CFD) model. The FSI analysis performed between 20 Hz and 80 Hz was used to predict the stiffness and damping of the HSFD using a quarter-section model of the damper. The FSI analysis was able to support test results by showing only a 6–7.4% change in the magnitude of force coefficients. Stiffness predictions agree reasonably well with experiments whereas damping is underpredicted.

Engineering↗

Initial dynamic photoactive materials testing of an atmospheric chamber intended for radioactive and hazardous gases

Radioisotopes and hazardous gases can have undetermined environmental pathways. Researchers at Pacific Northwest National Laboratory constructed a chamber that complies with the requirements needed for an atmospheric reaction platform and the safety principles of interacting with hazardous dispersible sources to enable the environmental testing of these gases. Initial dynamic testing showed inter-chamber mixing completed from minutes to 1.5 hours. The photooxidation of butyl iodine showed the presence of signals from reaction products, and intermediaries for up to 50 hours. Current detection limits of the chamber and analytical collection and testing approach were shown to be in the single-digit parts per billion levels. In conclusion, the comparisons between the measured oxidation trends and literature show the utility of performing laboratory experiments to validate the results of modeling for larger-scale scenarios.

54 ENVIRONMENTAL SCIENCES↗

DOE-GENIORS Dynamic Irradiation Testing

As part of the homogeneous actinides recycling strategy, the EURO-GANEX process is one of the most promising options to achieve the goal of minor actinides recovery. Improvements made to EURO-GANEX system have resulted in the emergence of the so-called New EURO-GANEX process, where the composition of the solvent has been modified by replacing TODGA and DMDOHEMA with cis-mTDDGA in the organic phase and SO3-Ph-BTP with PyTri-Diol in the aqueous phase in order to resolve important issues. The objective of this work is twofold: evaluate the gamma radiolytic resistance of the new EURO-GANEX process by dynamic irradiation conditions simulating the three main steps of the process, and validate the design of CIEMAT Náyade, CEA Marcel and INL irradiation loop devices since each of them mimics different aspects of the real process. Náyade and the INL loops could irradiate the organic and aqueous phases together, whereas in the CEA loop, the irradiated solvent is recycled continuously inside a platform with several stages of mixer-settlers containing aqueous flows simulating the three main steps of the process. The extraction performances and changes in the composition of the solvent have been analyzed during the irradiation experiment by different techniques: gamma spectrometry and ICP-MS/OES for cations or radioactive tracer extraction, and HPLC-MS to identify and quantify the degradation compounds. Despite some differences between the three-irradiation facilities, this inter-institutional study shows that these three comparative tools provide similar trends in the radiolytic stability of a liquid-liquid extraction system. Favourable extraction results for the different steps are obtained according to the static irradiation studies found in literature. However, the degradation of cis-mTDDGA is appreciable leading to degradation compounds, some of which form precipitates and produce important changes in viscosity, important aspects that must be addressed prior to the successful industrial application of the new EURO-GANEX process.

38 - RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCL↗