Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dynamic temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Design and simulated performance of a CARS spectrometer for dynamic temperature measurements using electronic heterodyning

A new design for generating CARS signals and for the detection and processing of these signals is presented and evaluated. The design is based on electronic heterodyning of the CARS spectrum of nitrogen at two selected narrowband frequencies, ratioing the resulting signal strengths, and comparing this ratio with a theoretically derived temperature scale. A reference cell is incorporated into the design for system calibration and for accurate temperature measurements. The spectrometer is found capable of measuring temperature in the submillisecond time scale with an accuracy of 10 percent in the 1000-2000 K temperature range. A typical result using the Hg(x)Cd(1-x)Te photomixer for T = 1500 K, Delta T = 50 K is a SNR of 21 dB and a data collection rate of 300 Hz.

Deen, M. Jamal↗

Conservation laws in coupled cluster dynamics at finite temperature

We extend the finite-temperature Keldysh non-equilibrium coupled cluster theory (Keldysh-CC) [A. F. White and G. K.-L. Chan, J. Chem. Theory Comput. 15, 6137–6253 (2019)] to include a time-dependent orbital basis. When chosen to minimize the action, such a basis restores local and global conservation laws (Ehrenfest’s theorem) for all one-particle properties while remaining energy conserving for time independent Hamiltonians. We present the time-dependent Keldysh orbital-optimized coupled cluster doubles method in analogy with the formalism for zero-temperature dynamics, extended to finite temperatures through the time-dependent action on the Keldysh contour. To demonstrate the conservation property and understand the numerical performance of the method, we apply it to several problems of nonequilibrium finite-temperature dynamics: a 1D Hubbard model with a time-dependent Peierls phase, laser driving of molecular H2, driven dynamics in warm-dense silicon, and transport in the single impurity Anderson model.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Acoustic Database for Turbofan Engine Core-Noise Sources: Volume - I

In this program, a database of dynamic temperature and dynamic pressure measurements were acquired inside the core of a TECH977 turbofan engine to support investigations of indirect combustion noise. Dynamic temperature and pressure measurements were recorded for engine gas dynamics up to temperatures of 3100 degrees Fahrenheit and transient responses as high as 1000 hertz. These measurements were made at the entrance of the high pressure turbine (HPT) and at the entrance and exit of the low pressure turbine (LPT). Measurements were made at two circumferential clocking positions. In the combustor and inter-turbine duct (ITD), measurements were made at two axial locations to enable the exploration of time delays. The dynamic temperature measurements were made using dual thin-wire thermocouple probes. The dynamic pressure measurements were made using semi-infinite probes. Prior to the engine test, a series of bench, oven, and combustor rig tests were conducted to characterize the performance of the dual wire temperature probes and to define and characterize the data acquisition systems. A measurement solution for acquiring dynamic temperature and pressure data on the engine was defined. A suite of hardware modifications were designed to incorporate the dynamic temperature and pressure instrumentation into the TECH977 engine. In particular, a probe actuation system was developed to protect the delicate temperature probes during engine startup and transients in order to maximize sensor life. A set of temperature probes was procured and the TECH977 engine was assembled with the suite of new and modified hardware. The engine was tested at four steady state operating speeds, with repeats. Dynamic pressure and temperature data were acquired at each condition for at least one minute. At the two highest power settings, temperature data could not be obtained at the forward probe locations since the mean temperatures exceeded the capability of the probes. The temperature data were processed using software that accounts for the effects of convective and conductive heat transfer. The software was developed under previous NASA sponsored programs. Compensated temperature spectra and compensated time histories corresponding to the dynamic temperature of the gas stream were generated. Auto-spectral and cross-spectral analyses of the data were performed to investigate spectral features, acoustic circumferential mode content, signal coherence, and time delays. The dynamic temperature data exhibit a wideband and fairly flat spectral content. The temperature spectra do not change substantially with operating speed. The pressure spectra in the combustor and ITD exhibit generally similar shapes and amplitudes, making it difficult to identify any features that suggest the presence of indirect combustion noise. Cross-spectral analysis reveal a strong correlation between pressure and temperature fluctuations in the ITD, but little correlation between temperature fluctuations at the entrance of the HPT and pressure fluctuations downstream of it. Temperature fluctuations at the entrance of the low pressure turbine were an order of magnitude smaller than those at the entrance to the high pressure turbine. Time delay analysis of the temperature fluctuations in the combustor was inconclusive, perhaps due to the substantial mixing that occurs between the upstream and downstream locations. Time delay analysis of the temperature fluctuations in the ITD indicate that they convect at the mean flow speed. Analysis of the data did not reveal any convincing indications of the presence of indirect combustion noise. However, this analysis has been preliminary and additional exploration of the data is recommended including the use of more sophisticated signal processing to explore subtle issues that have been revealed but which are not yet fully understood or explained.

Aeroacoustics↗

Further development of the dynamic gas temperature measurement system. Volume 1: Technical efforts

A compensated dynamic gas temperature thermocouple measurement method was experimentally verified. Dynamic gas temperature signals from a flow passing through a chopped-wheel signal generator and an atmospheric pressure laboratory burner were measured by the dynamic temperature sensor and other fast-response sensors. Compensated data from dynamic temperature sensor thermoelements were compared with fast-response sensors. Results from the two experiments are presented as time-dependent waveforms and spectral plots. Comparisons between compensated dynamic temperature sensor spectra and a commercially available optical fiber thermometer compensated spectra were made for the atmospheric burner experiment. Increases in precision of the measurement method require optimization of several factors, and directions for further work are identified.

Elmore, D. L.↗

Further development of the dynamic gas temperature measurement system

A compensated thermocouple measurement method was experimentally verified. Dynamic signal content from an atmospheric pressure laboratory burner was measured by the dynamic temperature sensor and a relatively delicate fine-wire resistance thermometer. Compensated data from the two dynamic temperature sensor thermoelements were compared with the compensated fine-wire data in the frequency domain. Absolute differences between spectral line amplitudes measured with different sensors are small relative to the mean temperature and verify the compenation method. Increases in precision of the measurement method require optimization of several factors, and directions for further work are identified.

Elmore, D. L.↗

Furthur development of the dynamic gas temperature measurement system

Candidate concepts capable of generating dynamic temperatures were identified and analyzed for use in verifying experimentally the frequency response of the dynamic gas temperature measurement system. A rotating wheel concept and one other concept will be selected for this purpose. Modifications to the data reduction code algorithms developed were identified and evaluated to reduce substantially the data reduction execution time. These modifications will be incorporated in a new data reduction program to be written in FORTRAN IV.

Elmore, D. L.↗

Further development of the dynamic gas temperature measurement system

Two experiments for verifying the frequency response of a previously-developed dynamic gas temperature measurement system were performed. In both experiments, fine-wire resistance temperature sensors were used as standards. The compensated dynamic temperature sensor data will be compared with the standards to verify the compensation method. The experiments are described in detail.

Elmore, D. L.↗

Dynamic gas temperature measurement system. Volume 2: Operation and program manual

The hot section technology (HOST) dynamic gas temperature measurement system computer program acquires data from two type B thermocouples of different diameters. The analysis method determines the in situ value of an aerodynamic parameter T, containing the heat transfer coefficient from the transfer function of the two thermocouples. This aerodynamic parameter is used to compute a fequency response spectrum and compensate the dynamic portion of the signal of the smaller thermocouple. The calculations for the aerodynamic parameter and the data compensation technique are discussed. Compensated data are presented in either the time or frequency domain, time domain data as dynamic temperature vs time, or frequency domain data.

Purpura, P. T.↗

Further development of the dynamic gas temperature measurement system

The objective of this effort was to experimentally verify a dynamic gas temperature measurement system in laboratory experiments. The dynamic gas temperature measurement system verification program is described. A brief description of the sensor geometry and construction is followed by a discussion of the probe heat transfer analysis and subsequent compensation method. The laboratory experiments are described and experimental results are discussed. Finally, directions for further investigation are given.

Elmore, D. L.↗

Models for dynamic surface temperatures during rarefied aeropass maneuvers

New models for calculating dynamic surface temperatures in a direct simulation Monte Carlo particle method during atmospheric entry are described. The models take into account the radiative emissivity, thermal conductivity, and heat capacity of the material. They are applied to thin panels in a highly rarefied flows and yield the transient thermal response of individual surface facets. Simulation results for radiation panels with internal conductivity are verified by comparing them with free molecule theory.

Haas, Brian L.↗

Quantum and classical spin dynamics across temperature scales in the S = 1 / 2 Heisenberg antiferromagnet

Using the framework of semiclassical Landau-Lifshitz dynamics (LLD), we conduct a systematic investigation of the temperature-dependent spin dynamics in the S = 1 / 2 Heisenberg square-lattice antiferromagnet (SAFM). By performing inelastic neutron scattering measurements on Zn 2 VO ( PO 4 ) 2 (ZVPO) and corresponding finite-temperature spin dynamics simulations based on LLD, we present a comprehensive analysis that bridges quantum and classical spin dynamics over a broad temperature range. First, remarkable agreement between experimental data and LLD simulations is found in the paramagnetic phase of ZVPO, demonstrating the capability of LLD in accurately determining the spin Hamiltonian of S = 1 / 2 systems and capturing the quantum-to-classical crossover of their spin dynamics. Second, by analyzing the discrepancies between the experimental data and the LLD simulations at lower temperatures, we determine the experimental temperature dependence of the quantum effects in the excitation spectrum of the S = 1 / 2 SAFM: the quantum renormalization factor for the magnon energies and the quantum continuum above the one-magnon bands. Notably, the emergence of each quantum effect is found to correlate with the formation of three-dimensional long-range order. This work demonstrates the utility of LLD in gaining experimental insights into the temperature-induced modifications of quantum spin dynamics and their convergence towards classical expectations at higher temperatures. This motivates further applications to more challenging quantum antiferromagnets dominated by stronger quantum fluctuations. Published by the American Physical Society 2024

36 MATERIALS SCIENCE↗

Development of procedures for calculating stiffness and damping properties of elastomers in engineering applications. Part 2: Elastomer characteristics at constant temperature

Dynamic properties of a commerical polybutadiene compound were determined at a constant temperature of 32 C by a forced-vibration resonant mass type of apparatus. The constant thermal state of the elastomer was ensured by keeping the ambient temperature constant and by limiting the power dissipation in the specimen. Experiments were performed with both compression and shear specimens at several preloads (nominal strain varying from 0 to 5 percent), and the results are reported in terms of a complex stiffness as a function of frequency. Very weak frequency dependence is observed and a simple power law type of correlation is shown to represent the data well. Variations in the complex stiffness as a function of preload are also found to be small for both compression and shear specimens.

Gupta, P. K.↗

Dynamic gas temperature measurement system

A gas temperature measurement system with compensated frequency response of 1 KHz and capability to operate in the exhaust of a gas turbine combustor was developed. Environmental guidelines for this measurement are presented, followed by a preliminary design of the selected measurement method. Transient thermal conduction effects were identified as important; a preliminary finite-element conduction model quantified the errors expected by neglecting conduction. A compensation method was developed to account for effects of conduction and convection. This method was verified in analog electrical simulations, and used to compensate dynamic temperature data from a laboratory combustor and a gas turbine engine. Detailed data compensations are presented. Analysis of error sources in the method were done to derive confidence levels for the compensated data.

Elmore, D. L.↗

Measurement of the time-temperature dependent dynamic mechanical properties of boron/aluminum composites

A relatively simple flexural vibration test is developed for accurate measurement of the low-strain dynamic modulus and damping capacity of B/Al composite bar specimens from -200 C to over 500 C. The specimens are prepared from 8-ply unidirectional panels containing 50 volume percent fibers composed of 203-micron commercial boron-on-tungsten fibers. The basic test technique consists of the forced flexural vibration of the composite bar specimens at their two lowest free-free symmetrical resonant modes in a high-vacuum cryostat furnace. Specimen damping is determined from oscilloscope photographs of the free decay obtained after simultaneously removing the resonant drive signal and grounding the vibration-drive electrode. The availability of time-temperature dynamic data coupled with the predictive accuracy of composite theory suggests a future potential for using such data in examining environmental effects on composite macrostructure and microstructure.

Dicarlo, J. A.↗

Further development of the dynamic gas temperature measurement system. Volume 2: Computer program user's manual

The Dynamic Gas Temperature Measurement System compensation software accepts digitized data from two different diameter thermocouples and computes a compensated frequency response spectrum for one of the thermocouples. Detailed discussions of the physical system, analytical model, and computer software are presented in this volume and in Volume 1 of this report under Task 3. Computer program software restrictions and test cases are also presented. Compensated and uncompensated data may be presented in either the time or frequency domain. Time domain data are presented as instantaneous temperature vs time. Frequency domain data may be presented in several forms such as power spectral density vs frequency.

Stocks, Dana R.↗

Temperature and Dynamic Strain Measurements Using a Single SAWR Sensor

Dynamic strain sensing is relevant in numerous applications involving structural health monitoring, condition-based maintenance, operation efficiency preservation, and work environment safety. These sensors are particularly critical for high-temperature (HT) harsh-environment (HE) industries such as aerospace, automotive, power plants, and advanced manufacturing. In HT/HE, sensor implementation and measurement present challenges such as maintaining sensor stability, accounting for temperature cross-sensitivity, providing HT attachment, and packaging of the sensors and system. Surface acoustic wave resonator (SAWR) sensors can address these needs and offer additional benefits such as compact size and wireless interrogation capability. The SAWR sensitivity to dynamic strain is temperature dependent, making it necessary to measure the sensor temperature in order to use the correct dynamic strain calibration curve. In this work, a method for determining the temperature, dynamic strain magnitude, and dynamic strain spectral components using a single SAWR sensor is presented. Here, the established technique for determining operational temperature and dynamic strain magnitude/spectral components using only one SAWR simplifies the sensor measurement system, thus being very attractive for HT /HE applications.

47 OTHER INSTRUMENTATION↗

Dynamic gas temperature measurements using a personal computer for data acquisition and reduction

This report describes a dynamic gas temperature measurement system. It has frequency response to 1000 Hz, and can be used to measure temperatures in hot, high pressure, high velocity flows. A personal computer is used for collecting and processing data, which results in a much shorter wait for results than previously. The data collection process and the user interface are described in detail. The changes made in transporting the software from a mainframe to a personal computer are described in appendices, as is the overall theory of operation.

Fralick, Gustave C.↗