Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dynamic radiography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Diagnostic development and needs for laser driven MeV x-ray radiography

Laser-driven MeV x-ray radiography of dynamic, dense objects demands a small, high flux source of energetic x-rays to generate an image with sufficient quality. Understanding the multi-MeV x-ray spectrum underscores the ability to extrapolate from the current laser sources to new future lasers that might deploy this radiography modality. Here, in this study, we present a small study of the existing x-ray diagnostics and techniques. We also present work from National Ignition Facility-Advanced Radiographic Capability, where we deploy three diagnostics to measure the x-ray spectrum up to 30 MeV. Finally, we also discuss the needs and developments of two new diagnostics: a single crystal scintillator spectrometer and a fast decay activation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multiframe point-projection radiography imaging based on hybrid X-pinch

This paper demonstrates the possibility of using a new configuration of the hybrid X-pinch to produce a set of spatially and temporarily separate x-ray bursts that could be used for the radiography of dynamic events. To achieve this, a longer than normal wire is placed between the conical electrodes of the hybrid X-pinch, and a set of small spacers (fishing weights) is placed along the wire. Each subsection of the wire then acts as a unique X-pinch, producing its own radiation burst from a small (~3 µm) spot. The timing between bursts is 20–50 ns, and each is <2 ns in duration. For comparison, if a longer wire is simply employed without spacers, hotspots of radiation occur in random positions and the time between any two bursts does not exceed 20 ns. Examples of two and three frame point-projection radiography of solid-state and plasma test objects are given.

47 OTHER INSTRUMENTATION↗

An approach to characterizing spatial aspects of image system blur

Quantitative X-ray radiographic imaging systems that utilize a charged couple device (CCD) camera connected to a thick, monolithic scintillator can exhibit blur that varies spatially across the field of view, especially for thick scintillators used in pulse-power radiography of dynamically compressed objects. Here, a three-point approach to estimating and accounting for this effect is demonstrated by (a) using a local estimation technique to measure the effect of blurring a calibration object at key locations across the field of view, (b) combining each of the local estimates into a spatially varying blurring function via partitions of unity interpolation, and (c) resolving the effects of that blur on the image by solving an ill-posed inverse problem using a spatially varying regularization term. The technique is demonstrated on synthetic examples and actual radiographs collected at the Naval Research Laboratory’s (NRL)Mercury pulsed power facility.

97 MATHEMATICS AND COMPUTING↗

Onset dynamics of air-water menisci on rock fracture surfaces

Information on menisci dynamics and equilibrium contact angles, θ e , is needed for modeling multiphase flow of fluids in geologic formations. The wettability of fracture faces is relevant to applications such as waterflooding in enhanced oil recovery and evaluation of caprock integrity for geologic carbon sequestration. We investigated the vertical capillary rise of air-water menisci on exposed fracture faces for a sandstone, a shale, and three granites. The experimental design approximated that employed in the Wilhelmy plate method. Replicate fracture faces were prepared by fracturing cylindrical rock cores using the Brazilian method and splitting the fractured cores apart along their fracture planes. Meniscus onset was imaged from a cross-sectional perspective using dynamic neutron radiography, and quantified with change point analysis. An existing model for meniscus onset fitted the experimental data very well (median R 2 = 0.96). Capillary rise was typified by t 2/3 scaling (where t is time), followed by a constant equilibrium height, z e . The average time taken for the menisci to reach z e was 0.39 s, with no differences between rock types. The menisci achieved a greater vertical extent on the fracture faces of the sedimentary rocks as compared to those of the granites. Apparent θ e values were calculated from the best fit estimates of z e using the Wilhelmy plate equation for a smooth and planar vertical surface. Despite the fractal roughness of some of the fracture faces, there was a significant linear relationship (R 2 = 0.80) between the apparent θ e values and intrinsic θ e values measured on polished surfaces of the same rocks using the sessile drop method. The regression equation indicated the apparent θ e values were consistently greater than the intrinsic values. This overestimation may be due to averaging of pixels at the air-water-solid interface, a required step in the image analysis. Further exploration of the range of applicability and measurement accuracy of this proposed new technique would be valuable.

58 GEOSCIENCES↗

DARHT Overview [Slides]

DARHT is a key facility for Stockpile Stewardship. Dual Axis Radiographic Hydrodynamic Test Facility - World-class X-ray radiography for dynamic non-nuclear tests.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DARHT Axis 1 Bremsstrahlung Dose Measurements

he Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography ca pabilities using two electron Linear Induction Accelerators (LIA’s). Axis-1 of DARHT produces, nominally, a 20-MeV, 1.5-kA, 80-ns-Full Width at Half Max (FWHM) electron beam. The elec tron beam is focused on to a tantalum target to produce a Bremsstrahlung x-ray dose for flash radiography of dynamic systems. This paper will describe and compare a variety of techniques for determining the x-ray dose for two different beam currents produced by a 55mm and 70mm diameter cathode. The data was taken in November of 2022 on DARHT Axis 1. The experimen tal measurement techniques include a platinum calorimeter, a diamond radiation detector (DRD), and a Compton diode (CD). Gafchromic EBT3 self-developing dosimetry film was also used, but no useful results were obtained. Beam charge and energy were recorded and dose was calculated with this information using xtr with Dosecalcx, and simple dose charge-energy scaling. In this pa per, we will discuss the target geometry and experimental layout, the methods of measuring dose, dose diagnostics and measurement of beam charge and energy, and the comparisons of data and calculations.

43 PARTICLE ACCELERATORS↗

Development and investigation of single-scan TV radiography for the acquisition of dynamic physiologic data

A light amplifier for large flat screen fluoroscopy was investigated which will decrease both its size and weight. The work on organ contouring was extended to yield volumes. This is a simple extension since the fluoroscopic image contains density (gray scale) information which can be translated as tissue thickness, integrated, yielding accurate volume data in an on-line situation. A number of devices were developed for analog image processing of video signals, operating on-line in real time, and with simple selection mechanisms. The results show that this approach is feasible and produces are improvement in image quality which should make diagnostic error significantly lower. These are all low cost devices, small and light in weight, thereby making them usable in a space environment, on the Ames centrifuge, and in a typical clinical situation.

Baily, N. A.↗

Characterization of laser-accelerated proton beams from a 0.5 kJ sub-picosecond laser for radiography applications

Laser-accelerated ion beams show promise for many applications, including high-resolution flash imaging of static or dynamic objects in next-generation radiography to probe materials and plasmas in extreme environments and inertial confinement fusion. To scale up ion beam production for radiography applications, we conducted experiments using sub-picosecond lasers up to 0.5 kJ at the OMEGA-EP facility to characterize proton beams from solid targets, primarily CH/CD sub-micron thin films from which ion beams were also used for static and dynamic radiography for the first time. For standalone sub-micron thin CH films, the highest detected proton energy is in the range of 72–97 MeV. Proton beams with highest energy near or above 60 MeV at full laser energy and similar beam profiles are also measured from low-density CD foams and flat CH foil target of micrometer-scale thickness. The ~ 700–800 nm CH/CD foils achieve the highest ion yield among the targets tested. For sub-micron thin films, the laser prepulse can expand the target and lead to complex interactions, which is simulated using coupled hydrodynamic and two-step kinetic models. Simulations suggest the presence of a micrometer-scale preplasma plateau with near-critical density and further indicate that target normal sheath acceleration, electron heating from Relativistic transparency in the preplasma plateau, and background proton reflection from carbon ion front at the rear side contribute to the resulting proton spectrum from these sub-micron thin targets at various stages. These proton beams show strong potential for radiography and for production of secondary sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High Intensity Gamma Ray Source Scintillation Attenuation Spectrometer and Filter Stack Monoenergetic Calibration

The Laser-Based X-ray Radiographic Imaging team at Los Alamos National Lab is looking for a monoenergetic MeV X-ray source to both verify our Monte Carlo N-particle simulations of detector performance and calibrate the instruments for future measurements. Funded by the Laboratory Directed Research and Development (LDRD) program, our overall goal is to improve the radiographic quality and reliability of laser-based X-ray sources for deployment at both dynamic and static radiography facilities. Laser-based X-ray sources have demonstrated smaller spot sizes to current electron accelerator based sources. The smaller laser spot size leads to significantly improved resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving manganin gauge measurements near radiographic fiducials

In dynamic experiments diagnosed with radiography and stress gauges, the gauges are often placed adjacent to radio-graphic fiducials, such as Ta foil, which perturbs the stress measurement. We conducted experiments to test the performance of different arrangements of manganin stress gauges and Ta foils. Three different gauge/foil configurations were tested, as well as a solitary gauge as control. Gauge/foil layers were placed between high-density polyethylene (HDPE) discs and impacted by a projectile in a gas gun, a simplification of a dynamic, high explosive experiment configuration. The stress measurements were minimally perturbed when a section of foil was removed near the active element of the gauge, as expected. In conclusion, a follow-up experiment showed that the modification to the foil has minimal impact on the radiographic measurement of the dynamic flow.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The battery failure databank: Insights from an open-access database of thermal runaway behaviors of Li-ion cells and a resource for benchmarking risks

The thermal response of Li-ion cells can greatly vary for identical cell designs tested under identical conditions, the distribution of which is costly to fully characterize experimentally. The open-source Battery Failure Databank presented here contains robust, high-quality data from hundreds of abuse tests spanning numerous commercial cell designs and testing conditions. Data was gathered using a fractional thermal runaway calorimeter and contains the fractional breakdown of heat and mass that was ejected, as well as high-speed synchrotron radiography of the internal dynamic response of cells during thermal runaway. The distribution of thermal output, mass ejection, and internal response of commercial cells are compared for different abuse-test conditions, which when normalized on a per amp-hour basis show a strong positive correlation between heat output from cells, the fraction of mass ejected from the cells, their energy- and power-density. Ejected mass was shown to contain 10x more heat per gram than non-ejected mass. The causes of 'outlier' thermal and ejection responses i.e., extreme cases, are elucidated by high-speed radiography which showed how occurrences such as vent clogging can create more hazardous conditions. High-speed radiography also demonstrated how the time-resolved interplay of thermal runaway propagation and mass ejection influences the total heat generated.

25 ENERGY STORAGE↗

Experimental characterization of hot-electron emission and shock dynamics in the context of the shock ignition approach to inertial confinement fusion

We report on planar target experiments conducted on the OMEGA-EP laser facility performed in the context of the shock ignition (SI) approach to inertial confinement fusion. The experiment aimed at characterizing the propagation of strong shock in matter and the generation of hot electrons (HEs), with laser parameters relevant to SI (1-ns UV laser beams with I ~10 16 W/cm 2 ). Time-resolved radiographs of the propagating shock front were performed in order to study the hydrodynamic evolution. The hot-electron source was characterized in terms of Maxwellian temperature, T h , and laser to hot-electron energy conversion efficiency η using data from different x-ray spectrometers. The post-processing of these data gives a range of the possible values for T h and η [i.e., T h [keV] ϵ (20, 50) and η ϵ (2%, 13%)]. These values are used as input in hydrodynamic simulations to reproduce the results obtained in radiographs, thus constraining the range for the HE measurements. According to this procedure, we found that the laser converts ~10% ± 4% of energy into hot electrons with T h = 27 ± 8 keV. The paper shows how the coupling of different diagnostics and numerical tools is required to sufficiently constrain the problem, solving the large ambiguity coming from the post-processing of spectrometers data. The effect of the hot electrons on the shock dynamics is then discussed, showing an increase in the pressure around the shock front. Furthermore, the low temperature found in this experiment without pre-compression laser pulses could be advantageous for the SI scheme, but the high conversion efficiency may lead to an increase in the shell adiabat, with detrimental effects on the implosion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Understanding process-microstructure-property relationships in laser powder bed fusion of non-spherical Ti-6Al-4V powder

Powder feedstock is a major cost driver in metal additive manufacturing (AM). Replacing the spherical powder with the cost-efficient non-spherical one can reduce the feedstock cost up to 50% and attract more interest to adopt AM in production and new alloy development. Here, for this paper, a comprehensive study was conducted to understand process-microstructure-property relationships in laser powder bed fusion of hydride-dehydride Ti-6Al-4V powder. We demonstrated that variation of laser scan speed had a significant impact on the grain structure, pore evolution and properties compared to laser power. Dynamic X-ray radiography showed that with decreasing scan speed at a constant laser power, a transition from conduction to keyhole mode laser processing occurred, in which a deeper melt pool at lower scan speed intensified texture. In other words, an increase in laser scan speed resulted in formation of the refined prior β grains with shape factor of ~5, lowering the anisotropy. Furthermore, the degree of variant selection was evaluated based on the analyzed texture as a function of laser power and scan speed. With increasing laser scan speed, the dominant α/α boundary type was altered from type 2 to 4 and the degree of variant selection was noticeably decreased. On the other hand, increasing laser power left the morphology of prior β grains, their size, and the dominant α/α boundary (type 4) unchanged, while the texture and anisotropy were intensified, and the degree of variant selection was slightly decreased. Finally, dependency of surface roughness and microhardness were discussed as a function of laser processing parameters.

variant selection↗

Same-sided successive-shock HED instability experiments

Inertial confinement fusion (ICF) and high-energy density (HED) physics experiments experience complicated forcing for instability growth and mix due to the ubiquitous presence of multiple shocks interacting with perturbations on multiple material interfaces. One common driver of instability growth is successive shocks from the same direction. However, there is a severe lack of analytic work and modeling validation for same-sided successive shocks since they are extremely difficult to achieve with conventional (non-HED) drivers. Successive shocks access a large instability parameter space; idealized fluid theory [K. O. Mikaelian, Phys. Rev. A 31, 410 (1985)] predicts 15 different interface evolution scenarios for a sinusoidal perturbation. Growth becomes more complex for multi-mode, compressible HED systems. The Mshock campaign is the first experiment in any fluid regime to probe a wide portion of successive shock parameter space. This is enabled by our development of a hybrid direct/indirect drive platform capable of creating independently controllable successive shocks on the National Ignition Facility. These experiments have delivered the first data capable of rigorously challenging our models and their ability to accurately capture Richtmyer–Meshkov growth under successive shocks. Single-mode and two-mode experiments have successfully demonstrated the ability to access and control the various growth scenarios of the shocked interface, including re-inversion, freeze out, and continued growth. Simulations and theoretical modeling are shown to accurately capture the experimental observations in the linear growth phase, giving us confidence in our ICF/HED design codes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-Probe 22A: Post shot Data and Analysis

The Multi-Probe 22A experiments took place on the Omega EP laser in March 2022. The goal was to discover issues with simultaneous x-ray and proton radiography of static and dynamic test objects. The x-ray and proton probes were generated by short-pulse laser-matter interactions. Significant crosstalk between the proton beam and x-ray detector was observed. Several static radiographs were made, including a set of proton images made with different laser energies. No dynamic objects were radiographed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multi-Probe FY25 Omega EP Shot Request [Slides]

The goal of the Multi-Probe experimental campaign is to assess the feasibility of using multiple probe types (x ray, proton, neutron, and electron) in future LANL radiographic facilities. X-ray and proton platforms have been demonstrated. The first attempts at simultaneous radiography were hampered by cross talk, which was the subject of FY23 & FY24 experiments. The major goal for FY25 is to demonstrate simultaneous radiography of both static and dynamic objects.

36 MATERIALS SCIENCE↗

Integrating fine root diameter and watershed mapping to characterize rhizosphere hydrology

Root morphology and soil hydraulic characteristics were integrated using watershed distance mapping to show water distribution and uptake across the plant-soil interface. Poplar (Populus deltoides, P. trichocarpa), maize (Zea mays), juniper (Juniperus virginiana), grape (Vitis rotundifolia) and maple (Acer saccharum) seedlings were grown in sand, after which root diameter and soil water dynamics were assessed via sequential neutron radiography. Three local soil regions (root-soil interface or edge, rhizosphere, bulk soil) were classified based on both radial distance from the root surface and diameter of the nearest root, from which changes in water content and distribution were characterized using digital image processing. Water content dynamics across the rhizosphere showed two different species-independent processes: a consistently elevated water content at the root-soil edge interface which increased with root diameter, and hysteresis as the rhizosphere transitioned to bulk soil (~0.5 cm from the root), independent of root diameter. Water uptake per unit root surface area declined exponentially with root diameter, independent of species. Results highlight the species-independent hydrologic characteristics of the rhizosphere and the potential for evaluating them in a local spatially connected soil context. Avenues for improved integration of soil and root characteristics are discussed.

59 BASIC BIOLOGICAL SCIENCES↗

Breakup dynamics in a pressure-swirl injector for urea-water solution applications: A computational study

The co-optimization of in-cylinder combustion and after-treatment technology has become a major aspect in engine design and development, with the goal of meeting the increasingly restrictive emission regulations in the transportation industry. Selective Catalytic Reduction is a robust technology to control the emission of NO x , and the injection of urea in water solution is the exhaust tailpipe is a key aspect of its operation. The proposed work uses high-fidelity Computational Fluid Dynamics to characterize the atomization dynamics of the liquid jet in relevant cross-flow conditions. The study focuses on a commercial low-pressure (9 bar) pressure-swirl injector which is characterized in its internal geometry through high-resolution X-ray micro-computational tomography. The internal two-phase flow has been modeled according to the volume-of-fluid approach in a large eddy simulation framework and validated against near-nozzle X-ray radiography measurement. Moreover, characterizing the breakup dynamics for the swirling hollow cone formation, and assessing the influence of the cross-flow in the breakup dynamics was completed. The results have been reported proposing Re-Oh maps and probability density functions of the spray kinematics. Higher cross-flow momentum generates an increase in the jet intact length and a reduction of the liquid droplet diameters. The axial momentum of the jet is affected by the cross-flow already in the near-nozzle region, determining a relevant deviation of the spray velocities. In conclusion, this work aims to inform the initialization of Eulerian-Lagrangian spray models through the assignment of droplet kinematics and static one-way coupling between volume-of-fluid results and Lagrangian spray parcels, to be used for system-size domain simulations.

33 ADVANCED PROPULSION SYSTEMS↗