Engineering PapersSearch

SEARCH · Engineering Papers

Results for “dyes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Sea dye marker provides visibility for 20 hours

Sea dye marker block releases a visible slick which lasts at least twelve hours. The dye marker uses a fluorescent dye in a heat cured binder which, when immersed in seawater, releases the dye at a controlled rate.

De Laat, F.

Tracking air-dropped drogues and dyes from aircraft in support of ERTS-1 circulation studies

The author has identified the following significant results. For two years ERTS-1 has been employed to investigate current circulation patterns in Delaware Bay under different tidal, flow, and wind conditions. Since sufficient numbers of current meters and boats are not available, air-droppable drogues and dye packs have been developed and tested. The drogues consist of a styrofoam float and a line to which is attached a stainless steel biplane. The length of the line determines at what depth currents will be monitored. The floats are color coded to distinguish their movement and mark the depth of the biplanes. Simultaneously floating and anchored dye packs of fluorescein dye have been deployed from aircraft. The movement of the dye and drogues is tracked by sequential aerial photography, using fixed markers on shore or on buoys as reference points to calibrate the scale and direction of drogue movement. The current data obtained by this technique is then used to annotate current circulation maps derived from ERTS-1 imagery.

Klemas, V.

A method of determining spectral analytical dye densities

A straightforward method for the user of color imagery to determine the spectral analytical density of dyes present in the processed imagery is presented. The method involves exposing a large number of different color patches on the film which span the gamut of the film's imaging capabilities. From integral spectral density measurements at 16 to 19 different wavelengths, the unit spectral dye curves for each of the three dyes present were determined in two different types of color films. A discussion of the use of these spectral dye densities to determine the transformation between integral density measurements and analytical density is presented.

Scarpace, F. L.

Linewidth characteristics of Raman-shifted dye laser output at 720 and 940 nm

Existing DIAL systems for water vapor measurements in the troposphere operate at wavelengths near 720 nm. The use of stronger water vapor absorption lines in the range 930 to 960 nm will significantly improve DIAL measurements in the upper troposphere and lower stratosphere where water vapor concentrations are low. The generation of light at 940 nm using a frequency doubled Nd:YAG pumped dye laser is inefficient due to the small absorption if infrared dyes at the pump wavelength. However, 940 nm generation utilizing stimulated Raman scattering of dye lasers is attractive because of a potentially high conversion efficiency plus the possibility of retaining the narrow linewidth available from some dye lasers. The Raman conversion efficiency and line broadening are presented for first Stokes operation at 720 and 940 nm using hydrogen and deuterium as the Raman media.

Grossmann, B. E.

Feasibility of solar-pumped dye lasers

Dye laser gains were measured at various pump-beam irradiances on a dye cell in order to evaluate the feasibility of solar pumping. Rhodamine 6G dye was considered as a candidate for the solar-pumped laser because of its high utilization of the solar spectrum and high quantum efficiency. Measurements show that a solar concentration of 20,000 is required to reach the threshold of the dye.

Lee, Ja H.

Threshold pump power of a solar-pumped dye laser

Threshold solar power for dye laser pumping has been determined by measuring the gain of a rhodamine 6G dye laser amplifier at various solar-simulated irradiances on an amplifier cell. The measured threshold was 20,000 solar constants (2.7 kW/sq cm) for the dye volume of 2 x 5 x 40 cu mm and the optimum dye concentration of 0.001 M. The threshold is about one-third of that achievable with a high-intensity solar concentrator.

Lee, Ja H.

Compact Ozone Differential Absorption Lidar (DIAL) Transmitter Using Solid-State Dye Polymers

A new potential DIAL laser transmitter is described that uses solid-state dye laser materials to make a simpler, more compact, lower mass laser system. Two solid-state dye laser materials were tested to evaluate their performance in a laser oscillator cavity end pumped by a pulsed Nd:YAG laser at 532 nm. The polymer host polymethyl-methacrylate was injected with a pyrromethene laser dye, PM 580, or PM 597. A narrowband laser oscillator cavity was constructed to produce visible wavelengths of 578 and 600 nm which were frequency doubled into the UV region (299 or 300 nm) by using a BBO crystal, resulting in a maximum energy of 11 mJ at a wavelength of 578 nm when pumped by the Nd:YAG laser at an energy of 100 mJ (532 nm). A maximum output energy of 378 microJ was achieved in the UV region at a wavelength of 289 nm but lasted only 2000 laser shots at a repetition rate of 10 Hz. The results are promising and show that a solid-state dye laser based ozone DIAL system is possible with improvements in the design of the laser transmitter.

Jones, Alton L., Jr.

Fluorescent indicator dyes for calcium ions

The present invention discloses a new class of highly fluorescent indicator dyes that are specific for calcium ions. The new fluorescent indicator dyes combine a stilbene-type fluorophore with a tetracarboxylate parent Ca.sup.2+ chelating compound having the octacoordinate pattern of liganding groups characteristic of EGTA and BAPTA. Preferred forms contain extra heterocyclic bridges to reinforce the ethylenic bond of the stilbene and to reduce hydrophobicity. Compared to their widely used predecessor, quin2, the new dyes offer up to thirty-fold brighter fluorescence, major changes in wavelength (not just intensity) upon Ca.sup.2+ binding, slightly lower affinities for Ca.sup.2+, slightly longer wavelengths of excitation, and considerably improved selectivity for Ca.sup.2+ over other divalent cations. These properties, particularly the wavelength sensitivity to Ca.sup.2+, make the dyes useful indicators for many intracellular applications, especially in single cells, adherent cell layers, or bulk tissues. The present invention also discloses an improved method for synthesizing alpha-acyloxyalkyl bromides wherein the bromides so synthesized are free of contaminating bis(1-bromoalkyl)ether. The improved method is exemplified herein in the synthesis of acetoxymethyl bromide, a compound useful in preparing the acetoxymethyl esters disclosed herein as novel Ca.sup.2+ specific fluorescent indicators.

Tsien, Roger Y.

Detection of microlesions induced by heavy ions using liposomes filled with fluorescent dye

In cells irradiation by heavy ions has been hypothesized to produce microlesions, regions of local damage. In cell membranes this damage is thought to manifest itself in the form of holes. The primary evidence for microlesions comes from morphological studies of cell membranes, but this evidence is still controversial, especially since holes also have been observed in membranes of normal, nonirradiated, cells. However, it is possible that damage not associated with histologically discernable disruptions may still occur. In order to resolve this issue, we developed a system for detecting microlesions based on liposomes filled with fluorescent dye. We hypothesized that if microlesions form in these liposomes as the result of irradiation, then the entrapped dye will leak out into the surrounding medium in a measurable way. Polypropylene vials containing suspensions of vesicles composed of either dipalmitoyl phosphatidylcholine, or a combination of egg phosphatidylcholine and cholesterol were irradiated at the Brookhaven National Laboratory using 56Fe ions at 1 GeV/amu. In several cases we obtained a significant loss of the entrapped dye above the background level. Our results suggest that holes may form in liposomes as the result of heavy ion irradiation, and that these holes are large enough to allow leakage of cell internal contents that are at least as large as a 1 nm diameter calcein molecule. c2004 COSPAR. Published by Elsevier Ltd. All rights reserved.

Non-NASA Center

Testing the Fraunhofer line discriminator by sensing fluorescent dye

The experimental Fraunhofer Line Discriminator (FLD) has detected increments of Rhodamine WT dye as small as 1 ppb in 1/2 meter depths. It can be inferred that increments considerably smaller than 1 ppb will be detectable in depths considerably greater than 1/2 meter. Turbidity of the water drastically reduces luminescence or even completely blocks the transmission of detectable luminescence to the FLD. Attenuation of light within the water by turbidity and by the dye itself are the major factors to be considered in interpreting FLD records and in relating luminescence coefficient to dye concentration. An airborne test in an H-19 helicopter established feasibility of operating the FLD from the aircraft power supply, and established that the rotor blades do not visibly affect the monitoring of incident solar radiation.

Stoertz, G. E.

Laser head for simultaneous optical pumping of several dye lasers

The invention is a laser head for simultaneous pumping several dye lasers with a single flash lamp. The laser head includes primarily a multi-elliptical cylinder cavity with a single flash lamp placed along the common focal axis of the cavity and with capillary tube dye cells placed along each of the other focal axes of the cavity. The inside surface of the cavity is polished. Hence, the single flash lamp supplies the energy to the several dye cells.

Mumola, P. B.

A Dye-Tracer Technique for Experimentally Obtaining Impingement Characteristics of Arbitrary Bodies and a Method for Determining Droplet Size Distribution

A dye-tracer technique has been developed whereby the quantity of dyed water collected on a blotter-wrapped body exposed to an air stream containing a dyed-water spray cloud can be colorimetrically determined in order to obtain local collection efficiencies, total collection efficiency, and rearward extent of impingement on the body. In addition, a method has been developed whereby the impingement characteristics obtained experimentally for a body can be related to theoretical impingement data for the same body in order to determine the droplet size distribution of the impinging cloud. Several cylinders, a ribbon, and an aspirating device to measure cloud liquid-water content were used in the studies presented herein for the purpose of evaluating the dye-tracer technique. Although the experimental techniques used in the dye-tracer technique require careful control, the methods presented herein should be applicable for any wind tunnel provided the humidity of the air stream can be maintained near saturation.

VonGlahn, Uwe H.

A tunable dual frequency dye laser - dual frequency oscillator design

The pulsed dye laser offers a tunable oscillator, followed by three amplifiers. It is pumped by a dual frequency Nd:YAG laser. Tuning and spectral width are controlled by a holographic network connected to a high power telescope. The modified two wavelength dye laser allows for absorption lidar techniques for remote sensing of the atmosphere. Line switching is achieved by electrooptical commutation. A feasibility experiment was performed with the original oscillator. A model was then built, and tested with different dyes. After a few modifications were made to improve the conversion efficiency, this oscillator was inserted in the laser to check whether the amplifier stages were correctly adjusted.

Abury, Y.

Dye laser traveling wave amplifier

Injection locking was applied to a cavity-dumped coaxial flashlamp pumped dye laser in an effort to obtain nanosecond duration pulses which have both high energy and narrow-linewidth. In the absence of an injected laser pulse, the cavity-dumped dye laser was capable of generating high energy (approx. 60mJ) nanosecond duration output pulses. These pulses, however, had a fixed center wavelength and were extremely broadband (approx. 6nm FWHM). Experimental investigations were performed to determine if the spectral properties of these outputs could be improved through the use of injection-locking techniques. A parametric study to determine the specific conditions under which the laser could be injection-locked was also carried out. Significant linewidth reduction to 0.0015nm) of the outputs was obtained through injection-locking but only at wavelengths near the peak lasing wavelength of the dye. It was found, however; that by inserting weakly dispersive tuning elements in the laser cavity, these narrow-linewidth outputs could be obtained over a wide (24nm) tuning range. Since the tuning elements had low insertion losses, the tunability of the output was obtained without sacrificing output pulse energy.

Davidson, F.

Linewidth characteristics of Raman-shifted dye laser output at 720 and 940 nm

A compact and simple simultaneous multi-wavelength dye laser cavity was developed for a differential absorption technique. Dielectric multilayer interference filters were inserted inside the cavities as tuning elements, and two types of a DIAL system were constucted by using the dye laser tuned with dielectric multilayer filters to measure NO2 concentration. The usefulness of this dye laser was clarified for the differential absoroption technique in outdoor experiments. Some basic designs of the laser cavity with these filters to get simultaneously multi-wavelength output are summarized.

Grossmann, B. E.

Reactive Fluorescent Dyes For Urethane Coatings

Molecules of fluorescent dyes chemically bound in urethane conformal-coating materials to enable nondestructive detection of flaws in coats through inspection under ultraviolet light, according to proposal. Dye-bonding technique prevents outgassing of dyes, making coating materials suitable for use where flaw-free coats must be assured in instrumentation or other applications in which contamination by outgassing must be minimized.

Willis, Paul B.

Dye-Sensitized Solar Cells for Space Power

During the course of this grant, dye-sensitized solar cells were prepared and characterized. The solar cells were prepared using materials (dyes, electrolytes, transparent conductive oxide coated glass, nanocrystalline TiO2) entirely prepared in-house, as well as prepared using materials available commercially. Complete cells were characterized under simulated AM0 illumination. The best cell prepared at NASA had an AM0 efficiency of 1.22% for a 1.1 sq cm cell. Short circuit current (Isc), open circuit voltage (Voc) and fill factor (FF) for the cell were 6.95 mA, 618 mV and 42.8%, respectively. For comparison purposes, two commercially prepared dye-sensitized solar cells were obtained from Solaronix SA, Aubonne, Switzerland. The Solaronix cells were also characterized under simulated AM0 illumination. The best cell from Solaronix had an active area of 3.71 sq cm and measured an AM0 efficiency of 3.16%. with Isc, Voc and FF of 45.80 mA, 669.6 mV and 52.3%, respectively. Both cells from Solaronix were rapid thermal cycled between -80 C and 80 C. Thermal cycling led to a 4.6% loss of efficiency in one of the cells and led to nearly a complete failure in the second cell.

Harris, Jerry D.

Bench-Top Antigen Detection Technique that Utilizes Nanofiltration and Fluorescent Dyes which Emit and Absorb Light in the Near Infrared

This article discusses the development of a bench-top technique to detect antigens in fluids. The technique involves the use of near infrared NIR fluorescent dyes conjugated to antibodies, centrifugation, nanofilters, and spectrometry. The system used to detect the antigens utilizes a spectrometer, fiber optic cables, NIR laser, and laptop computer thus making it portable and ideally suited for desk top analysis. Using IgM as an antigen and the secondary antibody, anti-IgM conjugated to the near infrared dye, IRDye (trademark) 800, for detection, we show that nanofiltration can efficiently and specifically separate antibody-antigen complexes in solution and that the complexes can be detected by a spectrometer and software using NIR laser excitation at 778 nm and NIR dye offset emission at 804 nm. The peak power detected at 778 nm for the excitation emission and at 804 nm for the offset emission is 879 pW (-60.06 dBm) and 35.7 pW (-74.5 dBm), respectively.

Varaljay-Spence, Vanessa A.