Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “duct systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Duct System Flammability and Air Sealing Fire Separation Assemblies in the International Residential Code

IBACOS identified two barriers that limit the ability of builders to cost-effectively achieve higher energy efficiency levels in housing. These are (1) the use of duct system materials that inherently achieve airtightness and are appropriately sized for low-load houses and (2) the ability to air seal fire separation assemblies. The issues identified fall into a gray area of the codes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Plug-and-Play Duct System Evaluation

This report describes an air distribution system composed of a series of uniformly-sized ducts that terminate in rooms throughout the home and return to a central manifold, similar in fashion to a “home-run” cross-linked polyethylene plumbing system. With a well-designed manifold, each duct receives an equal static pressure potential for airflow from the air handling unit, and the number of needed ducts for each room are simply attached to fittings located on the manifold; in this sense, the system is plug-and-play (PnP). As indicated, all ducts in the PnP system are identical in size and small enough to fit in the ceiling and wall cavities of a house (i.e., less than 3.5-in. outer diameter). These ducts are also more appropriately sized for the lower airflow requirements of modern, energy-efficient homes; therefore, the velocity of the air moving through the duct is between that of conventional duct systems (approximately 700 ft/min) and high-velocity systems (more than 1,500 ft/min) on the market today. The PnP duct system uses semi-rigid plastic pipes, which have a smooth inner wall and are straightforward to install correctly, resulting in a system that has minimal air leakage. However, plastic ducts are currently not accepted by code for use in residential buildings; therefore, the project team considered other duct materials for the system that are currently accepted by code, such as small-diameter, wirehelix, flexible ductwork.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Plug-and-Play Duct System Evaluation

This report describes an air distribution system composed of a series of uniformly-sized ducts that terminate in rooms throughout the home and return to a central manifold, similar in fashion to a “home-run” cross-linked polyethylene plumbing system. With a well-designed manifold, each duct receives an equal static pressure potential for airflow from the air handling unit, and the number of needed ducts for each room are simply attached to fittings located on the manifold; in this sense, the system is plug-and-play (PnP). As indicated, all ducts in the PnP system are identical in size and small enough to fit in the ceiling and wall cavities of a house (i.e., less than 3.5-in. outer diameter). These ducts are also more appropriately sized for the lower airflow requirements of modern, energy-efficient homes; therefore, the velocity of the air moving through the duct is between that of conventional duct systems (approximately 700 ft/min) and high-velocity systems (more than 1,500 ft/min) on the market today. The PnP duct system uses semi-rigid plastic pipes, which have a smooth inner wall and are straightforward to install correctly, resulting in a system that has minimal air leakage. However, plastic ducts are currently not accepted by code for use in residential buildings; therefore, the project team considered other duct materials for the system that are currently accepted by code, such as small-diameter, wirehelix, flexible ductwork.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling dynamically coupled fluid-duct systems with finite line elements

Structural analysis of piping systems, especially dynamic analysis, typically considers the duct structure and the contained fluid column separately. Coupling of these two systems, however, forms a new dynamic system with characteristics not necessarily described by the superposition of the two component system's characteristics. Methods for modeling the two coupled components simultaneously using finite line elements are presented. Techniques for general duct intersections, area or direction changes, long radius bends, hydraulic losses, and hydraulic impedances are discussed. An example problem and results involving time transients are presented. Additionally, a program to enhance post-processing of line element models is discussed.

Saxon, J. B.↗

Ice Protection of Turbojet Engines by Inertia Separation of Water I : Alternate-duct System

Aerodynamic and icing investigations of internal water-inertia separation inlets designed to prevent automatically entrance of large quantities of water into a turbojet engine in icing conditions was conducted on a one-half scale model. A simplified analytical approach to the design of internal water-inertia separation inlets is included. Results show that in order to be effective in preventing screen and guide-vane icing for an inlet of this type, a ram-pressure recovery of 75 percent was attained at design inlet-velocity ratio in an icing condition. For nonicing operation, ram-pressure recovery is comparable to direct-ram inlet.

INLETS, NOSE - CENTRAL↗

The acoustics of aircraft engine-duct systems

Noise generated in aircraft engines is usually suppressed by acoustically treating the engine ducts. The optimization of this treatment requires an understanding of the transmission and attenuation of the acoustic waves. A critical review is presented of the state of the art regarding methods of determining the transmission and attenuation parameters and the effect on these parameters of (1) acoustic properties of liners, (2) the mean velocity, including uniform and shear profiles and nonparallel flow, (3) axial and transverse temperature gradients, (4) slowly and abruptly varying cross sections, and (5) finite-amplitude waves and nonlinear duct liners.

Nayfeh, A. H.↗

Bellows joint absorbs torsional deflections in duct system

Long, thin-walled bellows compressed into a short length absorbs the same amount of torsional deflection as the same tube in full length condition and saves in cost, complexity and space. This bellows has lower torsional spring rate to absorb the bulk of the duct assembly tortional deflections, leaving the other bellows free to absorb axial and angular deflections.

Daniels, C. M.↗

Building America Case Study: Raised Ceiling Interior Duct System, New Smyrna, Florida (Fact Sheet)

One of BA-PIRC's longtime Habitat for Humanity partners, S.E. Volusia CO (SEVHFH), was interested in building a home to the new Challenge Home standards. SEVHFH routinely builds ENERGY STAR V3.1 homes. The only modification to their design needed to comply with the Challenge Home criteria was the interior duct requirement. Unwilling to incur the added costs of a foam roof deck or wall heights above 8 feet to accommodate a fur-down chase SEVHFH opted to build a fur-up or raised ceiling chase.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Retrofitting Air Conditioning and Duct Systems in Hot, Dry Climates

This technical report describes CARB's work with Clark County Community Resources Division in Las Vegas, Nevada, to optimize procedures for upgrading cooling systems on existing homes in the area to implement health, safety, and energy improvements. Detailed monitoring of five AC systems showed that three of the five systems met or exceeded air flow rate goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology Solutions Case Study: Raised Ceiling Interior Duct System, New Smyrna, Florida

Builder S.E. Volusia County Habitat for Humanity (SEVHFH) was interested in constructing a home to the new U.S. Department of Energy (DOE) Zero Energy Ready Home standards. SEVHFH partners with DOE team Building America Partnership for Improved Residential Construction on Habitat for Humanity homes and routinely builds to ENERGY STAR V3.1. The only modification to the design needed to comply with the Zero Energy Ready Home criteria was the interior duct requirement. Unwilling to incur the added costs of a foam roof deck or wall heights that exceed 8 ft to accommodate a fur-down chase, SEVHFH opted to build a fur-up or raised ceiling chase. This case study describes the project.

BA-PIRC↗

Protocol for Determining Actual Flow Rate in FTWC Duct Systems

This paper is intended to document the theory and methods to determine the actual flow rate in the exhaust system used to ventilate the Flanged Tritium Waste Containers based on realtime instrument readings. Section 1 provides introductory and background material; Section 2 details the various correction factors used to adjust flow readings for ambient air pressure and temperature and other operational parameters. Section 3 provides guidance on implementing this process during venting operations, and Section 4 provides supporting documentation and also a field checklist that can be used by personnel during venting. For Revision 1, a summary of editorial changes made to the paper was added as Section 4.4, as well as a section documenting peer review (Section 4.5).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗