Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “drop on demand”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Challenges to Rural Service Transformers on Increased Electric Vehicle Charging Infrastructure

As Electric Vehicle (EV) electric charging demand increases so to does the corresponding load requirements for charging the vehicles. The expansion of power distribution assets is therefore a critical issue to address on whether rural service transformers can handle the increase in EV load demand. Large-scale EV deployment is likely to cause problems in the localized distributions systems bringing challenges such as increased load demand, increased system losses, and additional voltage drops. This paper investigates how rural service transformer resiliency plays an important role in these challenges. EV charging can create new load peaks exceeding the service transformer's rated capacity, thereby accelerating equipment aging. EV charging can also both positively and negatively affect transformer aging. The core purpose of this paper is to investigate that change in service life of rural service transformers.

Mukherjee, Srijib↗

Overcoming persistent challenges in putting environmental flow policy into practice: a systematic review and bibliometric analysis

The implementation of environmental flows (e-flows) aims to reduce the negative impacts of hydrological alteration on freshwater ecosystems. Despite the growing attention to the importance of e-flows since the 1970s, actual implementation has lagged. Therefore, we explore the limitations in e-flows implementation, their systemic reasons, and solutions. We conducted a systematic review and a bibliometric analysis to identify peer-reviewed articles published on the topic of e-flows implementation research in the last two decades, resulting in 68 research and review papers. Co-occurrence of terms, and geographic and temporal trends were analyzed to identify the gaps in environmental water management and propose recommendations to address limitations on e-flows implementation. We identify the underlying causes and potential solutions to such challenges in environmental water management. The limitations to e-flow implementation identified were categorized into 21 classes. The most recognized limitation was the competing priorities of human uses of water (n = 29). Many secondary limitations, generally co-occurring in co-causation, were identified as limiting factors, especially for implementing more nuanced and sophisticated e-flows. The lack of adequate hydrological data (n = 24) and ecological data (n = 28) were among the most mentioned, and ultimately lead to difficulties in starting or continuing monitoring/adaptive management (n = 28) efforts. The lack of resource/capacity (n = 21), experimentation (n = 19), regulatory enforcement (n = 17), and differing authorities involved (n = 18) were also recurrent problems, driven by the deficiencies in the relative importance given to e-flows when facing other human priorities. In order to provide a clearer path for successful e-flow implementation, system mapping can be used as a starting point and general-purpose resource for understanding the sociohydrological problems, interactions, and inherited complexity of river systems. Secondly, we recommend a system analysis approach to address competing demands, especially with the use of coupled water-energy modeling tools to support decision-making when hydropower generation is involved. Such approaches can better assess the complex interactions among the hydrologic, ecological, socioeconomic, and engineering dimensions of water resource systems and their effective management. Lastly, given the complexities in environmental water allocation, implementation requires both scientific rigor and proven utility. Consequently, and where possible, we recommend a move from simplistic flow allocations to a more holistic approach informed by hydroecological principles. To ease conflicts between competing water demands, water managers can realize more 'pop per drop' by supporting key components of a flow regime that include functional attributes and processes that enhance biogeochemical cycling, structural habitat formation, and ecosystem maintenance.

54 ENVIRONMENTAL SCIENCES↗

Cryogenic Carbon Capture™ (CCC) Status Report

The Cryogenic Carbon Capture™ (CCC) process separates CO2 from light gases in essentially any continuous process. CCC cools the gases to the frost or desublimation point of CO2 (-100 to -135 °C), separates and pressurizes the solids, and warms all streams to produce a CO2-depleted stream at ambient pressure and a pure (99+%) pressurized liquid CO2 stream typically to about 150 bar, both at ambient temperature. The process also recovers all gas moisture and most gas impurities less volatile than CO2 (NOx, SOx, Hg, PM, UHC, CCC, etc.) in separable streams. CCC nearly eliminates refrigeration energy for sensible temperature changes through heat integration. CCC does require energy to change the CO2 phase from a mixed vapor to a pressurized fluid, which represents the minimum energy required of any process for this separation. CCC uses additional energy for turbomachinery inefficiencies, heat losses, moisture removal and overall process pressure drop. Aside from these real-world energy demands, CCC operates near the minimum energy required to perform this gas separation by minimizing stream recycling. CCC compresses CO2 as a liquid, which is one of several reasons it costs about about half as much and consumes about half as much energy as an amine process when using flue gases with about 15% CO2. The process also has several major additional advantages, including (a) it is a bolt-on retrofit technology that does not need steam or any modification of existing equipment, (b) it recovers water and nearly all pollutants in addition to CO2 from the flue gas, (c) it enables highly efficient and cost effective energy storage at grid scale and on time scales of minutes, (d) it enables NG storage if the energy storage option is used, and (d) it has a small footprint and is minimally disruptive to existing plants, requiring only electrical power and a gas source to operate. Sustainable Energy Solutions (SES) has scaled this technology through several levels, the largest of which captures nominally 1 tonne of CO2/day and is called the skid system. Skid system field tests include utility-scale power plants, cement plants, heating plants, and other utility or industrial sites that burn natural gas, biomass, coal, shredded tires, municipal waste, and combinations of these fuels. These field tests produced 95-99% CO2 capture with CO2 purities of 99+% and initial CO2 contents that range from 4 to 28%. SES currently seeks to scale the system to merchant scale (10-80 tonnes of CO2 per day). In the process of doing so, SES has demonstrated the potential for CCC to contribute to energy storage and direct air capture in innovative and cost-effective ways. This presentation discusses the overall process and highlights results from field and in-house tests. These include (a) measured CO2 capture rates and operating conditions from in-house and field tests, and (b) predicted utility-scale costs and energy demands. This discussion also includes the application of the CCC technology to energy storage and direct air capture.

20 FOSSIL-FUELED POWER PLANTS↗

Soot formation and precursor chemistry in Counterflow flames of aviation fuel surrogates

To meet market demands, the aviation sector is interested in utilizing drop-in Synthetic Aviation Turbine Fuels (SATF), either as neat fuels or in blends with conventional Jet A. SATF currently approved in standard specifications may have lower aromatic content with significant fractions of normal, branched, and cyclo-alkanes. Fundamental studies on soot formation from aviation fuels (Jet A, SATF) and their surrogate components are essential to understand how fuel composition influences soot and soot precursor formation. Here, this study reports new measurements of polycyclic aromatic hydrocarbons (PAH) and soot in counterflow diffusion flames (CDFs) of aviation fuel surrogates. Both intrusive and non-intrusive diagnostics are employed to determine the profiles of temperature, gas phase species, PAHs (up to C16), and soot volume fraction (SVF) in CDFs of iso-octane and surrogate mixtures. These measurements shed light on the transition of soot precursors to primary soot particles. In addition to serving as a common surrogate component in Jet A surrogate mixtures, iso-octane is a template species for larger, less volatile branched alkanes found in SATF mixtures. The newly developed Lawrence Livermore National Laboratory (LLNL) PAH and soot model successfully captures temperature, precursor species, and SVF profiles for the mixtures and conditions discussed in this work. Finally, a high-fidelity surrogate for Jet A is proposed that matches targeted physical and chemical properties well, while leveraging the wide range of candidate fuel molecules available in the LLNL detailed chemical model. The proposed surrogate formulation is validated against newly acquired measurements of the surrogate and literature measurements of Jet A. These new experiments and simulations provide critical insights into the PAH and soot formation from aviation fuels. Reaction pathways which require further investigation are highlighted, such that future work may bridge the remaining quantitative gaps in predicting soot formation from aviation fuel surrogates and surrogate components.

Aviation fuels↗

Smart Labs Final Report Summer 2021

The Smart Labs Project at Los Alamos National Laboratory (LANL) is an initiative derived from The University of California, Irvine and is part of the Department of Energy’s (DOE) Better Buildings Challenge. These carbon abatement strategies aim to reduce energy consumption of laboratories while also maintaining health and safety requirements. Smart Labs designs incorporate seven key principles which are: digital control systems, demand-based ventilation, low power-density demand-based lighting, exhaust fan discharge velocity optimization, pressure drop optimization, fume hood flow optimization, and commissioning with automated cross-platform fault detection. As the ALDCP Smart Labs team for the summer of 2021, the scope of the project is to determine the energy savings within building 03-1698 (Material Science Laboratory - MSL). Over the past couple of years, the Sustainability Group has been adding Smart Labs upgrades into the MSL building and the summer team would like to understand the impact made for the overall energy consumption/demand and safety for the building, determine the overall return on investment (ROI), and recommend more Smart Labs upgrades that can be added to the MSL building. The goal is to enable the UI FOD (Utilities and Infrastructure Facility Operation Division) to promote more Smart Labs projects in the future and further the reputation LANL and DOE facilities have of being leading examples of developers of high performing buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Seasonal Reconfiguration of Electrical Distribution Systems to Mitigate the Impact of Electric Vehicle Charging

Power grids face challenges in their infrastructure related to the integration of electric vehicles (EV). In particular, EV charging stations may induce instability in key system parameters such as substantial voltage drops, active power losses, and transformer overload due to high demand during charging periods. This article presents a seasonal reconfiguration strategy based on the differential evolution (DE) algorithm, aimed at enhancing system performance under highly variable and stochastic load profiles, particularly those driven by EV charging. The DEA algorithm is hybridized with the find-union (FU) algorithm to efficiently ensure network radiality throughout the optimization process. The proposed methodology is validated on a hybrid distribution system composed of the IEEE 33-bus network, a modified IEEE 13-bus system, and a specific 13-bus microgrid. Results have demonstrated that seasonal reconfiguration significantly reduces active power losses and mitigates transformer loading during critical demand hours, thereby quantifiably increasing the system’s performance. As an integral component of the proposed approach, an analysis of CO2 emissions associated with energy losses is included, allowing a contextualized assessment of the environmental benefits of seasonal reconfiguration in various geographical areas.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Urban heat islands can influence the wind energy resource during heatwaves

Urban wind energy is critical for sustainable electricity generation in cities. However, little research has explored how the urban heat island (UHI) effect influences wind energy, particularly in heatwaves when energy demand surges. In this study, we examine wind energy distribution in the Boston–Providence metropolitan area during heatwaves, using Weather Research and Forecasting (WRF) model integrated with Building Energy Parameterization/Building Energy Model (BEP/BEM). Two scenarios, a realistic case and a hypothetical case without urban warmth, were compared to isolate UHI impacts. Results reveal that UHI induces a "wind energy loss zone" in this urban area, reducing wind power density (WPD) by 20–30 W/m 2 at 50–100 m, while suburban/rural areas exhibit a "wind energy gain zone," with WPD increases up to 40 W/m 2 at 150–200 m. These losses diminish with distance from urban centers and become negligible beyond main urban and suburban sprawl. Heatwave expands the urban "loss zone", while amplifying wind energy gains in suburban/rural areas, driven by stronger thermal gradients and weakened background winds that intensify air convergence in urban and urban-rural circulations, thereby exacerbating urban wind energy losses by 15–20 %. An analysis of 235 wind farms using turbine power curves reveals that built areas dependent on stand-alone or off-grid turbines face significant energy deficits during a heatwave. Wind energy drops by up to 25 %, while cooling-related building energy demand rises 30–40 % during a heatwave. These findings underscore the need for strategic urban wind energy planning to ensure reliable power during extreme heat.

Energy - Wind↗

Curb Allocation and Pick-Up Drop-Off Aggregation for a Shared Autonomous Vehicle Fleet

Advances in information technologies and vehicle automation have birthed new transportation services, including shared autonomous vehicles (SAVs). Shared autonomous vehicles are on-demand self-driving taxis, with flexible routes and schedules, able to replace personal vehicles for many trips in the near future. The siting and density of pick-up and drop-off (PUDO) points for SAVs, much like bus stops, can be key in planning SAV fleet operations, since PUDOs impact SAV demand, route choices, passenger wait times, and network congestion. Unlike traditional human-driven taxis and ride-hailing vehicles like Lyft and Uber, SAVs are unlikely to engage in quasi-legal procedures, like double parking or fire hydrant pick-ups. In congested settings, like central business districts (CBD) or airport curbs, SAVs and others will not be allowed to pick up and drop off passengers wherever they like. This paper uses an agent-based simulation to model the impact of different PUDO locations and densities in the Austin, Texas CBD, where land values are highest and curb spaces are coveted. In this paper 18 scenarios were tested, varying PUDO density, fleet size and fare price. The results show that for a given fare price and fleet size, PUDO spacing (e.g., one block vs. three blocks) has significant impact on ridership, vehicle-miles travelled, vehicle occupancy, and revenue. A good fleet size to serve the region’s 80 core square miles is 4000 SAVs, charging a $1 fare per mile of travel distance, and with PUDOs spaced three blocks of distance apart from each other in the CBD.

Hunter, Christian B.↗

Understanding the Dissolution and Passivation of an Aluminum Electrode during Electrocoagulation of Groundwater Using Neutron and X-ray Reflectometry

An aluminum (Al)-based electrocoagulation (EC) system can effectively remove dissolved silica and hardness in groundwater. The effectiveness of Al-EC in terms of pollutant removal, Faradaic efficiency, and energy consumption depends on the interfacial electrolysis or passivation of the electrode in water. Thus, understanding the electrolysis reaction at the liquid/electrode interface during operation is important for sustainable EC deployment. Here, a continuous flow-through Al-EC system was tested with various groundwater simulants, i.e., chloride (Cl – )-based, sulfate (SO 4 2– )-based, and mixed solutions. High pollutant removal with low energy consumption was observed in Cl – -based groundwater treatment, while low pollutant removal with high energy consumption was observed in SO 4 2– -based groundwater. For example, the required energy per unit mass of Al dosing in SO 4 2– -based groundwater is three times higher than that in Cl – -based groundwater at 10 mA/cm 2 . However, increasing the Cl – concentration significantly reduces this energy demand. In SO 4 2– -based groundwater, the silicate removal efficiency drops from 85.1% to 24.0% compared to that for Cl – -based groundwater, while Mg 2+ and Ca 2+ removal efficiencies decrease to 0.6% from 15.8% and 5.7% from 44.8%, respectively. To better understand this EC performance, we used in situ neutron reflectometry (NR) to examine the interfacial dynamics of Al dissolution and passivation at a 100 nm scale occurring on the surface of the sacrificial Al electrodes during EC. Ex situ X-ray reflectometry (XRR) was also used to support the in situ NR results. Both NR and XRR results revealed that Al dissolution is influenced by the presence of Cl – in the simulants, while a passivating layer forms on the electrode in a SO 4 2– -based solution. In the Cl – -based solution, anodic Al dissolution occurred locally and inhomogeneously across the surface of the Al anode film, resulting in a localized thickness reduction over time. In the SO 4 2– -based solution, no apparent dissolution of the Al anode was identified. Instead, Al underwent oxidation, forming an amorphous Al 2 O 3 surface layer within the Al electrode film that increased in thickness over time. In the mixed solution, both anodic Al dissolution and surface Al 2 O 3 layer formation occurred, indicating that Al dissolution and surface Al 2 O 3 layer formation are attributable to the Cl – and SO 4 2– ions, respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spatial Impacts of Electric Vehicle Charging on Power Grid Stability: A Downtown Atlanta Case Study

The rapid increase in electric vehicle (EV) charging demand poses a potential risk to power grid stability, particularly as the spatial distribution of this demand remains underexplored. Existing research often focuses on technical optimization models while overlooking the geographic and human dynamics that affect energy consumption. This study addresses this gap by incorporating mobility data to estimate both building energy use and EV charging demand while also considering geographic factors for a better understanding of grid load. Using agent-based simulations and the Open-Source Distribution System Simulator, the study evaluates the effect of various EV penetration scenarios on grid voltage and unbalance. The results show that, although voltage remains within acceptable limits at lower EV penetration rates, significant voltage drop and unbalance occur as EV penetration exceeds 40%, particularly in residential areas with high charging demand. This study offers a framework for integrating spatial analysis and mobility data in power network simulations, providing insights for future EV infrastructure planning.

Pan, Melrose [ORNL] (ORCID:000000031627448X)↗

Data Interfaces for Automated Vehicle Services - A Municipality Perspective

As Automated Vehicle (AV) services proliferate, data sharing between AV operators and municipal agents is assuming greater importance. Information on the dynamic nature of the road system such as incidents to avoid, weather hazards (such as flooding), construction and detours, as well as active safety concerns (e.g. - riots) is important for AV operators. Such information cannot be directly sensed from a vehicle's sensor array, but instead must be communicated in a timely and trustworthy channel. Municipalities are interested in pushing this information to AV operators to support emergency response efforts, reduce traffic in construction zones, and generally improve operation of the system. Similarly, information on vehicle safety such as disengagements, as well as critical information on the use of roadway system (trips, origin and destination patterns) are important performance factors for municipalities to understand utilization and plan for appropriate infrastructure. As mobility shifts to on-demand options, the need for safe and coordinated pick-up and drop-off zones will increase (potentially reducing parking needs). For all of these reasons, communication flows between AV operators and municipalities are becoming increasingly important. This paper investigates the functions, emerging practices and protocols for sharing of such critical data, and identifies gaps in and challenges in existing practices. Additionally, case studies are used to highlight the impacts of data sharing between AV operators and municipalities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Thermal performance and energy consumption validation of an occupied local government office building outfitted with ceiling tile phase change materials

Buildings present an opportunity for energy conservation and the modulation of peak energy demand through controlled Heating, Ventilation, and Air Conditioning (HVAC) energy use. The administrative and office building stock in the United States holds potential to achieve energy and demand savings through retrofits such as insulation, weatherization, and thermal energy storage. Specifically, there is a need to validate passive phase change material (PCM) applications in full scale in aging administrative buildings in the US to evaluate the energy benefits. Aim of this study was to conduct a whole building level thermal and energy validation of an operational building and explore an alternative method for evaluating energy efficiency. To accomplish this, the study employed PCMs in the drop ceiling and carry out an energy audit and on-site measurement of HVAC systems' energy demand and consumption. A full-scale EnergyPlus energy model, modeled by the authors, served as a baseline for evaluation. The results show that calibrated model's envelope temperature measures fall within the accepted errors. HVAC energy simulation results also fall within the accepted errors for monthly and hourly pre- and post- PCM retrofit electricity and natural gas data. The novelty of this study is that it employees energy scales per Heating Degree Hour and Cooling Degree Hour, in contrast to the commonly used Heating Degree Days and Cooling Degree Days as reported in the literature to analyze energy savings. These findings underscore the pivotal role of a calibrated model in assessing the efficacy of a singular energy measure, like a PCM-retrofitted ceiling, in an occupied office building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cooling Egypt: Cost and benefits of room air conditioner efficiency improvement in Egypt

Egypt is one of the largest countries in the Middle East and North Africa region with a population of a total of 106 million (as of July 2022). Increasing urbanization, population growth, and increasing temperatures will likely continue to drive demand for electricity from air conditioning, with corresponding negative impacts on the peak load, air quality, and greenhouse gas emissions from refrigerant use and energy consumption. Since 2003, Egypt has adopted a standards and labeling program for various appliances, and has improved its room air conditioner (RAC) energy efficiency requirements in 2016 and 2017. However, its market is still dominated by inefficient fixed-speed drive (FSD) RACs due to a price-sensitive market. Seasonal metrics such as Cooling Season Performance Factor (CSPF) measure the energy efficiency of FSD and variable-speed drive (VSD) RACs on the same scale. Leading markets, most notably China, have already adopted a new MEPS in 2020 and 2022, which align largely with the United for Efficiency (U4E) Model Regulations Guidelines. India has also adopted a CSPF metric. Both India and China are now experiencing (1) increased demand and consumption of higher efficiency VSD RACs, as well as (2) a corresponding drop in prices from the economies of scale of production of these higher efficiency RACs. Because China is a leading manufacturer in the global air conditioner (AC) market, its adoption of the model U4E regulations have effectively raised the energy efficiency of the ACs in the global market. To achieve the benefits of taking a similar approach to Egypt’s market, we offer the following recommendations: 1. Adopt a common metric to measure the efficiency of both FSD and VSD RACs 2. Raise the stringency of MEPS to the level of the U4E Model Regulation Guidelines 3. Restructure the labeling program from the “A++” labeling scheme to a simpler A through E or a star-rating program 4. Strengthen the compliance regime governing the Egyptian AC MEPS 5. Assist small and medium AC manufacturers in Egypt to transition manufacturing lines to produce low-cost, high-efficiency VSD RACs. Adopting these recommendations would reduce Egypt’s electricity consumption to 11 TWh in 2030 and 89 TWh in 2050—with corresponding carbon dioxide (CO2) emissions reductions and avoided generation capacity requirements compared to the baseline.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Impacts of water scarcity on agricultural production and electricity generation in the Middle East and North Africa

Incorporating the interdependencies between water, energy and food (WEF) within an integrated approach of planning and management could help nations worldwide to address sustainability concerns. This is a topic of great importance for the Middle East and North Africa (MENA) region, where water is a very limited resource. In this study, we develop an analytical framework to analyze the water-energy-food nexus in the MENA region to inform the formulation of integrated strategies for water, energy and food activities. Our approach is based on an integrated assessment model for the MENA region, which explicitly represents WEF sectors within an economic framework, in tandem with a set of relevant scenarios addressing three key dimensions (socioeconomics, climate and water-management). Using this framework, our study analyzes the current and projected status of water resources in the region, and the potential implications for the agriculture and electricity sectors. Our scenarios demonstrate that water scarcity worsens by the end of the 21st century in most MENA countries, mostly due to growing demands. The impacts of growing scarcity on agriculture are significant, with production projected to drop by 60 percent by 2050 in some countries. On the other hand, and to a lesser extent, water-saving technologies and fuel-switching in the power sector play a key role in mitigating the effects of water scarcity on electricity generation in some parts of the MENA region. Our analysis then underscores the need to reduce the dependence of MENA’s agricultural and energy sectors on water, and transition to renewable energies to reduce water scarcity.

54 ENVIRONMENTAL SCIENCES↗

Topical Report – Findings on Subtask 2.7 – Wet ESP and Aerosol Testing at Coal Creek Station

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion carbon capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery. The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the unique components present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants by contributing to aerosol formation. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and flue gas particulate provides nucleation sites where amine vapors can condense as aerosols. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, particulate components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to fully characterize aerosol behavior with various control technologies installed to better optimize aerosol mitigation technology for CO 2 capture. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on mitigating formation of problematic aerosols at Great River Energy’s Coal Creek Station, upstream of the PCCC system. Determine the effectiveness of the Mitsubishi Heavy Industries (MHI) proprietary amine emission reduction unit (AERU) as a postcapture solvent recovery system for reducing aerosol emissions and extending solvent life downstream of the PCCC system. Determine the impact of aerosols on the efficiency and degradation products of both commercial and advanced solvents within the PCCC system. Work was conducted at Coal Creek Station Unit 1 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then optionally routed through a WESP before passing to the CO 2 absorber columns. The MHI solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . Flue gas exiting the absorber column was routed to MHI’s proprietary AERU to recover entrained solvent. The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Particulate was measured, collected, and analyzed from multiple locations throughout the pilot-scale system. Unlike the performance observed in prior work, the inlet FGD and DCC did not remove significant particulate matter from the flue gas. This appears to be due to a difference in the nature of the particulate. The DCC seemed to increase particulate size and count, most likely owing to water condensing onto the surfaces of fly ash particles. When the WESP was operated, it achieved >95% particulate capture. Very little particulate matter or indications of solvent were detected at the AERU outlet. When operating with advanced KS 21 solvent, the particulate material at the AERU outlet was even further decreased. Solvent analysis showed that some species derived from flue gas and ash were slowly concentrating in the solvent over the duration of the test. The levels observed were reported to be within expected ranges and were not of concern to MHI. A high-level techno-economic assessment of installing CO 2 capture at Coal Creek Station suggested that, when using a standard monoethanolamine (MEA)-based solution with simple heat integration, the energy penalty to net generation would be 34%. The bulk of this was due to steam losses for regenerating solvent, followed by parasitic electrical demand for CO 2 compression and then by increased parasitic load for pushing flue gas through the absorber column. These demands could be decreased with a more advanced solvent that exhibits lower heat of regeneration and lower pressure drop than does a simple MEA solution. Further energy could be saved with more thorough heat integration to recover useful energy from the steam used for solvent regeneration. Installing a WESP was predicted to increase the cost of electricity by nearly $5/MWh. This would become cost-effective if solvent losses were roughly 10 times the baseline estimate when not using a WESP but could be returned to baseline by installing the WESP. Piping CO 2 for storage in more favorable geology could help with carbon capture and storage economics. Although storing off-site would necessitate construction of a CO 2 transport pipeline, the cost of this pipeline might be more than offset by reducing the number of wells required, the depths of the wells required, and the electrical demand for the CO 2 compressor. Additional factors that favor off-site storage costs include smaller expected CO 2 plume sizes, which translates to less monitoring and fewer landowner agreements. More detailed assessment of the specific geology in the region under and around Coal Creek Station would be needed to accurately assess the costs and benefits of different storage site options. This subtask was cofunded through the Energy & Environmental Research Center–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission.

Strege, Joshua↗

Replacing liquid fossil fuels and hydrocarbon chemical feedstocks with liquid biofuels from large-scale nuclear biorefineries

Liquid fossil fuels (1) enable transportation and (2) provide energy for mobile work platforms and (3) supply dispatchable energy to highly variable demand (seasonal heating and peak electricity). We describe a system to replace liquid fossil fuels with drop-in biofuels including gasoline, diesel and jet fuel. Because growing biomass removes carbon dioxide from the air, there is no net addition of carbon dioxide to the atmosphere from burning biofuels. In addition, with proper management, biofuel systems can sequester large quantities of carbon as soil organic matter, improving soil fertility and providing other environmental services. In the United States liquid biofuels can potentially replace all liquid fossil fuels. The required system has two key features. First, the heat and hydrogen for conversion of biomass into high-quality liquid fuels is provided by external low-carbon energy sources--nuclear energy or fossil fuels with carbon capture and sequestration. Using external energy inputs can almost double the energy content of the liquid fuel per unit of biomass feedstock by fully converting the carbon in biomass into a hydrocarbon fuel. Second, competing effectively with fossil fuels requires very large biorefineries—the equivalent of a 250,000 barrel per day oil refinery. This requires commercializing methods for converting local biomass into high-density storable feedstocks that can be economically shipped to large-scale biorefineries.

09 - BIOMASS FUELS↗

Exploring impacts of electricity tariff on charging infrastructure planning: An activity-based approach

In the past decade, electric vehicles (EVs) have gained popularity for their efficiency and environmental benefits. Advances in battery technology and charging equipment have yielded long-range EVs and fast-charging. However, many major cities lack adequate charging infrastructure for daily EV use. This study addresses this gap by integrating activity-based modeling, charging behavior simulation, and charging infrastructure optimization. The research utilizes the POLARIS agent-based transportation model to accurately capture user activities, trip patterns, and traffic flows. Additionally, the study investigates the impact of fixed and spatiotemporal electricity rate distributions on optimal charging infrastructure deployment. The framework is applied to the Chicago regional area network and analyzed under various EV ownership scenarios. Further, the results reveal significant impacts of the charging pricing strategy on user decision-making and charging demand distribution. There is also a need for consistent pricing policies in charging infrastructure planning and operational phases to avoid drops in service quality.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Case Study: NREL Campus Chilled Water Storage Potential: Benchmark Datasets Development and Applications, Task 4 - Use Case Demonstration

The Benchmark Datasets Development and Applications project is a three-year collaboration between the National Renewable Energy Laboratory (NREL), Oak Ridge National Laboratory, Pacific Northwest National Laboratory, and Lawrence Berkeley National Laboratory. The project seeks to collect and curate high-resolution, well-calibrated time series of building operational and indoor/outdoor environmental data, which are crucial to understanding and optimizing building energy efficiency performance and demand flexibility capabilities as well as benchmarking energy algorithms. Project outcomes include approximately twelve high-fidelity building datasets, enhanced data representation tools, and four case studies to illustrate example applications. The goal of these case studies is to define and execute analyses that demonstrate how one or more datasets collected through this project can address a data gap or challenge historically faced by building stakeholders. This technical paper summarizes the findings of one of these case studies, in which we studied the operational efficiencies of the central cooling system at NREL. We looked at three years of data from the three chillers in the Field Test Laboratory Building (FTLB), from 2019 to 2021, to compare equipment operation and demand throughout the time period. Our analysis indicates that all three chillers are operating at or below the optimal loading conditions for most of the operation time, and thus there was no efficiency drop due to loading of the chillers at full capacity. Our recommendation is that no chiller capacity increase is needed; instead, the central plant could benefit from adopting advanced control logics for optimal sequencing of chillers during part load operations. Analysis of adding chilled water thermal storage to the central plant indicated 34% savings in demand cost and 24.5% savings in total cost (energy consumption and demand charge cost). The payback period is estimated to be 11-22 years with an assumed TES cost of $\$$100-$200 per ton. This case study shows how a selected dataset is used to solve a practical building problem - learning the operational status of its components, analyzing the effectiveness of a proposed new technique, and aiding decision-making for the building operations and maintenance team.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗