Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “driving range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Magnetic Gearing Versus Conventional Gearing in Actuators for Aerospace Applications

Magnetic geared actuators (MGA) are designed to perform highly reliable, robust and precise motion on satellite platforms or aerospace vehicles. The design allows MGA to be used for various tasks in space applications. In contrast to conventional geared drives, the contact and lubrication free force transmitting elements lead to a considerable lifetime and range extension of drive systems. This paper describes the fundamentals of magnetic wobbling gears (MWG) and the deduced inherent characteristics, and compares conventional and magnetic gearing.

Puchhammer, Gregor↗

Characterization Testing of Lockheed Martin High-Power Micro Pulse Tube Cryocooler

This paper describes the thermal vacuum, microphonics, magnetics, and radiation testing and results of a Lockheed Martin high-power micro pulse tube cryocooler. The thermal performance of the microcooler was measured in vacuum for heat reject temperatures between 185 and 300 K. The cooler was driven with a Chroma 61602 AC power source for input powers ranging from 10 to 60 W and drive frequency between 115 and 140 Hz during thermal performance testing. The optimal drive frequency was dependent on both input power and heat reject temperature. In addition, the microphonics of the cooler were measured with the cooler driven by Iris Technologies LCCE-2 and HP-LCCE drive electronics for input powers ranging from 10 to 60 W and drive frequency between 135 and 145 Hz. The exported forces were strongly dependent on input power while only weakly dependent on the drive frequency. Moreover, the exported force in the compressor axis was minimized by closed loop control with the HP-LCCE. The cooler also survived a 500 krad radiation dose while being continuously operated with 30 W of input power at 220 K heat rejection temperature in vacuum. Finally, the DC and AC magnetic fields around the cooler were measured at various locations.

Rodriguez, Jose I.↗

Small passenger car transmission test; Chevrolet LUV transmission

A 1978 Chevrolet LUV manual transmission tested per the applicable portions of a passenger car automatic transmission test code (SAE J65lb) which required drive performance, coast performance, and no load test conditions. Under these test conditions, the transmission attained maximum efficiencies in the upper ninety percent range for both drive performance tests and coast performance tests. The major results of this test (torque, speed, and efficiency curves) are presented. Graphs map the complete performance characteristics for the Chevrolet LUV transmission.

Bujold, M. P.↗

Small passenger car transmission test: Dodge Omni A-404 transmission

The small passenger car transmission test was initiated to supply electric vehicle manufacturers with technical information regarding the performance of commercially available transmissions. This transmission was tested in accordance with a passenger car automatic transmission test code (SAE J65lb) which required drive performance, coast performance, and no load test conditions. Under these test conditions, the transmission attained maximum efficiencies in the mid eighty percent range for both drive performance test and coast performance tests.

Bujold, M. P.↗

Small passenger car transmission test: Mercury Lynx ATX transmission

The testing of a Mercury Lynx automatic transmission is reported. The transmission was tested in accordance with a passenger car automatic transmission test code (SAE J65lb) which required drive performance, coast performance, and no load test conditions. Under these conditions, the transmission attained maximum efficiencies in the mid-ninety percent range both for drive performance test and coast performance tests. The torque, speed, and efficiency curves are presented, which provide the complete performance characteristics for the Mercury Lynx automatic transmission.

Bujold, M. P.↗

Small passenger car transmission test; Ford C4 transmission

A 1979 Ford C4 automatic transmission was tested per a passenger car automatic transmission test code (SAE J651b) which required drive performance, coast performance, and no load test conditions. Under these test conditions, the transmission attained maximum efficiencies in the mid-eighty percent range for both drive performance tests and coast performance tests. The major results of this test (torque, speed, and efficiency curves) are presented. Graphs map the complete performance characteristics for the Ford C4 transmission.

Bujold, M. P.↗

Real-time image processing II; Proceedings of the Meeting, Orlando, FL, Apr. 16-18, 1990

The present conference discusses topics in the fields of feature extraction and implementation, filter and correlation algorithms, optical correlators, high-level algorithms, and digital image processing for ranging and remote driving. Attention is given to a nonlinear filter derived from topological image features, IR image segmentation through iterative thresholding, orthogonal subspaces for correlation masking, composite filter trees and image recognition via binary search, and features of matrix-coherent optical image processing. Also discussed are multitarget tracking via hybrid joint transform correlator, binary joint Fourier transform correlator considerations, global image processing operations on parallel architectures, real-time implementation of a differential range finder, and real-time binocular stereo range and motion detection.

Juday, Richard D.↗

Beyond 3-D: The New Spectrum of Lidar Applications for Earth and Ecological Sciences

Capturing and quantifying the world in three dimensions (x,y,z) using light detection and ranging (lidar) technology drives fundamental advances in the Earth and Ecological Sciences (EES). However, additional lidar dimensions offer the possibility to transcend basic 3-D mapping capabilities, including i) the physical time (t) dimension from repeat lidar acquisition and ii) laser return intensity (LRIλ) data dimension based on the brightness of single- or multi-wavelength (λ) laser returns. The additional dimensions thus add to the x,y, and z dimensions to constitute the five dimensions of lidar (x,y,z, t, LRIλ1... λn). This broader spectrum of lidar dimensionality has already revealed new insights across multiple EES topics, and will enable a wide range of new research and applications. Here, we review recent advances based on repeat lidar collections and analysis of LRI data to highlight novel applications of lidar remote sensing beyond 3-D. Our review outlines the potential and current challenges of time and LRI information from lidar sensors to expand the scope of research applications and insights across the full range of EES applications.

Eitel, Jan U. H.↗

Preliminary power train design for a state-of-the-art electric vehicle

The state-of-the-art (SOTA) of electric vehicles built since 1965 was reviewed to establish a base for the preliminary design of a power train for a SOTA electric vehicle. The performance of existing electric vehicles were evaluated to establish preliminary specifications for a power train design using state-of-the-art technology and commercially available components. Power train components were evaluated and selected using a computer simulation of the SAE J227a Schedule D driving cycle. Predicted range was determined for a number of motor and controller combinations in conjunction with the mechanical elements of power trains and a battery pack of sixteen lead-acid batteries - 471.7 kg at 0.093 MJ/Kg (1040 lbs. at 11.7 Whr/lb). On the basis of maximum range and overall system efficiency using the Schedule D cycle, an induction motor and 3 phase inverter/controller was selected as the optimum combination when used with a two-speed transaxle and steel belted radial tires. The predicted Schedule D range is 90.4 km (56.2 mi). Four near term improvements to the SOTA were identified, evaluated, and predicted to increase range approximately 7%.

Ross, J. A.↗

Submillimeter-wave receivers - A status report

A development status assessment is presented for the work of U.S. and Western European research groups on heterodyne sub-mm receivers in the 300-1000 GHz frequency range. The applications driving sub-mm receiver and local oscillator source technologies are radio astronomy, atmospheric measurements, plasma diagnostics, and laboratory spectroscopy. Progress is concentrated in two areas, cooled Schottky diode mixers and solid state local oscillators employing frequency multipliers.

Wilson, W. J.↗

Stress ratio effect on cyclic debonding in adhesively bonded composite joints

A study was conducted to investigate the stress ratio effect on cyclic debond growth behavior in adhesively bonded composite joints. The system studied consisted of graphite/epoxy adherends bonded with a toughened epoxy adhesive. This study showed that the strain energy release rate range was the driving factor for cyclic debonding of the tested bonded system when subjected to cyclic loads with different stress ratios for both mode I and mixed mode I-II loadings.

Mall, S.↗

Comparative Study of Lettuce and Radish Grown Under Red and Blue LEDs and White Fluorescent Lamps

Growing vegetable crops in space will be an essential part of sustaining astronauts during long-range missions. To drive photosynthesis, red and blue light-emitting diodes (LEDs) have attracted attention because of their efficiency, longevity, small size, and safety. In efforts to optimize crop yield, there is also recent interest in analyzing the subtle effects of additional wavelengths on plant growth. For instance, since plants often look purplish gray under red and blue LEDs, the addition of green light allows easy recognition of disease and the assessment of plant health status. However, it is important to know if wavelengths outside the traditional red and blue wavebands have a direct effect on enhancing or hindering the mechanisms involved in plant growth. In this experiment, a comparative study was performed on two short cycle crops of red romaine lettuce (Lactuca sativa cv. "Outredgeous") and radish (Raphanus sativa cv. 'Cherry Bomb'), which were grown under two light treatments. The first treatment being red (630 nm) and blue (450 nm) LEDs alone, while the second treatment consisted of daylight tri-phosphor fluorescent lamps (CCT approximately 5000 K) at equal photosynthetic photon flux (PPF). The treatment effects were evaluated by measuring the fresh biomass produced, plant morphology and leaf dimensions, leaf chlorophyll content, and adenosine triphosphate (ATP) within plant leaf/storage root tissues.

Food Production↗

Effects of White Leds on Growth and Phytonutrients of Outredgeous Romaine Lettuce When Supplemented with Various Monochromatic Wavelengths

Growing plants in space will be an essential part of sustaining astronauts during long-range missions. To drive photosynthesis, light-emitting diodes (LEDs) are becoming superior because of their efficiency, longevity, small size, safety, and wavelength versatility. Isolating the effects of certain wavelengths on plant growth when combined with white light is attracting attention. To optimize crop production/quality in space, this study has aimed to configure novel light recipes for the Advanced Plant Habitat currently aboard the International Space Station (ISS). By using white light as a background to maintain normal growth, the addition of monochromatic wavelengths provides a clearer understanding of how each part of the visible spectrum affects plant growth. By growing Outredgeous lettuce under six treatments of White (W) LEDs, W + blue (B), W+ green (G), W + red (R), W + far red (FR), and RGB + FR LEDs with ratios similar to natural sunlight, this investigation has assessed differences in biomass, morphology, chlorophyll, and the synthesis of key phytonutrients. The potential for Outredgeous to produce anthocyanin, lutein, potassium, magnesium, and iron is paramount to maintaining astronaut health. The crop responses to each treatment have been evaluated and the optimal LED combination for both plant yield and nutrient content will be presented.

Food Production↗

Identifying Ultra Low Frequency Waves in the Lunar Plasma Environment Using Trajectory Analysis and Resonance Conditions

Abstract Recent studies show that localized crustal magnetic fields on the lunar surface can reflect a significant portion of the incoming solar wind protons. These reflected ions can drive a wide range of plasma waves. It is difficult to determine the intrinsic properties of low-frequency waves with single-spacecraft observations, which can be heavily Doppler shifted. We describe a technique to combine trajectory analysis of reflected protons with the Doppler shift and resonance conditions to identify ultralow-frequency waves at the Moon. On 31 January 2014 plasma waves were detected by one of the Acceleration, Reconnection, Turbulence and Electrodynamics of the Moon's Interaction with the Sun (ARTEMIS) probes as it approached the lunar wake; these waves were not detected by the second ARTEMIS probe located upstream in the undisturbed solar wind. The observed waves had a frequency below the local ion cyclotron frequency and had right-hand circular polarization in the reference frame of the Moon. By solving the Doppler shift and the cyclotron resonance equations, we determined the conditions for reflected ions to excite the observed waves. Simulated trajectories of reflected ions correspond to ARTEMIS ion observations and support the hypothesis that reflected ions are the primary driver of the waves. By combining trajectory analysis with the resonance conditions, we identify scenarios where ions that satisfy the resonance conditions are present in the right location to generate the observed waves. Using this method, we can uniquely identify the observed waves as upstream propagating right-hand polarized waves, subject to the assumption that they are generated by cyclotron resonance with ions.

Magnetic↗

Application of Laser Ranging and VLBI Data to a Study of Plate Tectonic Driving Forces

The conditions under which changes in plate driving or resistive forces associated with plate boundary earthquakes are measurable with laser ranging or very long base interferometry were investigated. Aspects of plate forces that can be characterized by such measurements were identified. Analytic solutions for two dimensional stress diffusion in a viscoelastic plate following earthquake faulting on a finite fault, finite element solutions for three dimensional stress diffusion in a viscoelastic Earth following earthquake faulting, and quantitative constraints from modeling of global intraplate stress on the magnitude of deviatoric stress in the lithosphere are among the topics discussed.

Solomon, S. C.↗

In-Orbit Selection of Cryocooler Drive Frequencies for XRISM/Resolve

The XRISM/Resolve instrument cooling system uses adiabatic demagnetization refrigerators (ADRs) to cool the detectors to 50 mK and two types of cryocoolers to reduce heat load on the He tank, Joule-Thomson and Stirling cryocoolers. Resolve was designed with tunable cryocooler frequencies so that any mechanical interference and its effect on performance could be minimized. Measurements at different cryocooler drive frequencies were used to quantify the interference and narrow the acceptable range of frequency options. For Resolve the choice of cryocooler drive frequencies dramatically influences the instrument performance. Poor choices have been shown to degrade ADR cooling power and degrade the spectroscopic performance of the instrument. However, good choices have been shown to be free of undesirable features, allowing the instrument to satisfy its performance requirements with significant margin. Thus, the choice of drive frequencies is a critical factor for overall instrument performance. The drive frequencies of the Joule-Thomson cooler operating near 52 Hz, and the Stirling coolers operating near 15 Hz were adjusted in three distinct scan sequences to efficiently narrow the candidate frequency options. The frequency choices were based on stability of the 50 mK control thermometer, changes in the ADR demagnetization rate, and changes in detector noise. Scans across the drive frequency range of each cryocooler were performed multiple times during ground testing. Surprisingly, the results were not repeatable across test campaigns and did not conform to any discernable trend, but they were repeatable when remeasured within a single cool-down cycle. The conclusion was that the good/bad drive frequencies changed during Dewar warmup/cooldown, and possibly after mechanical vibration tests. Therefore, the settings could not be finalized before launch, and scans during instrument commissioning were necessary. This paper describes the cryocooler frequency scan measurements and compares the results during instrument commissioning to those performed during ground tests.

Gary A. Sneiderman↗