Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distribution system monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Modular Autonomous Systems Technology Framework: A Distributed Solution for System Monitoring and Control

The Modular Autonomous Systems Technology (MAST) framework is a tool for building distributed, hierarchical autonomous systems. Originally intended for the autonomous monitoring and control of spacecraft, this framework concept provides support for variable autonomy, assume-guarantee contracts, and efficient communication between subsystems and a centralized systems manager. MAST was developed at NASA's Johnson Space Center (JSC) and has been applied to an integrated spacecraft example scenario.

Badger, Julia M.↗

A study of a space communication system for the control and monitoring of the electric distribution system. Volume 2: Supporting data and analyses

It is technically feasible to design a satellite communication system to serve the United States electric utility industry's needs relative to load management, real-time operations management, remote meter reading and to determine the costs of various elements of the system. The functions associated with distribution automation and control and communication system requirements are defined. Factors related to formulating viable communication concepts, the relationship of various design factors to utility operating practices, and the results of the cost analysis are discussed The system concept and several ways in which the concept could be integrated into the utility industry are described.

Vaisnys, A.↗

Performance Monitoring of Distributed Data Processing Systems

Test and checkout systems are essential components in ensuring safety and reliability of aircraft and related systems for space missions. A variety of systems, developed over several years, are in use at the NASA/KSC. Many of these systems are configured as distributed data processing systems with the functionality spread over several multiprocessor nodes interconnected through networks. To be cost-effective, a system should take the least amount of resource and perform a given testing task in the least amount of time. There are two aspects of performance evaluation: monitoring and benchmarking. While monitoring is valuable to system administrators in operating and maintaining, benchmarking is important in designing and upgrading computer-based systems. These two aspects of performance evaluation are the foci of this project. This paper first discusses various issues related to software, hardware, and hybrid performance monitoring as applicable to distributed systems, and specifically to the TCMS (Test Control and Monitoring System). Next, a comparison of several probing instructions are made to show that the hybrid monitoring technique developed by the NIST (National Institutes for Standards and Technology) is the least intrusive and takes only one-fourth of the time taken by software monitoring probes. In the rest of the paper, issues related to benchmarking a distributed system have been discussed and finally a prescription for developing a micro-benchmark for the TCMS has been provided.

Ojha, Anand K.↗

Monitoring system and methods for a distributed and recoverable digital control system

A monitoring system and methods are provided for a distributed and recoverable digital control system. The monitoring system generally comprises two independent monitoring planes within the control system. The first monitoring plane is internal to the computing units in the control system, and the second monitoring plane is external to the computing units. The internal first monitoring plane includes two in-line monitors. The first internal monitor is a self-checking, lock-step-processing monitor with integrated rapid recovery capability. The second internal monitor includes one or more reasonableness monitors, which compare actual effector position with commanded effector position. The external second monitor plane includes two monitors. The first external monitor includes a pre-recovery computing monitor, and the second external monitor includes a post recovery computing monitor. Various methods for implementing the monitoring functions are also disclosed.

Stange, Kent↗

Low-cost embedded optical sensing systems for distribution transformer monitoring

There is a mounting need for low-cost monitoring with online sensing technologies to maintain grid reliability and uptime. Here we introduce an innovative low-cost, embedded optical sensing technology initially focused on transformers that was developed and demonstrated at a major electric utility, Con Edison. A version of it that can be retrofitted onto existing transformers in the field was also developed. Two new 500 kVA distribution network transformers were built with embedded fiber-optic (FO) sensors and qualified per industry standards. Vibration, temperature, and corrosion were key parameters monitored. The first transformer with embedded FO sensors was installed at a Con Edison facility and monitored at our team’s office. The second one was installed in an urban street-side underground location with online data processing/feature extraction algorithms and monitored through a wireless router. Additionally, an older transformer was also retrofitted. Data analysis was done on these transformers showing promising correlations with their corresponding loading cycles. Furthermore, key events such as the transformer primary-side energizing, and other events were detected. In general, the technology was demonstrated over 6 months across the 3 transformers instrumented with promising results. Thus, it has the potential to enable predictive maintenance for transformers and other grid assets.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Distributed Optical Fiber Sensor Systems for Pipeline Integrity Monitoring

Distributed fiber optic sensors allow the measurement of structural parameters such as static/dynamic strain, temperature, pressure, and vibrations at thousands of locations along a single fiber cable. Deep neural network (DNN) algorithms were developed for rapid data processing speed and vibration event classification.

Lalam, Nageswara↗

Distributed Interplanetary Delay/Disruption Tolerant Network (DTN) Monitor and Control System

The main purpose of Distributed interplanetary Delay Tolerant Network Monitor and Control System as a DTN system network management implementation in JPL is defined to provide methods and tools that can monitor the DTN operation status, detect and resolve DTN operation failures in some automated style while either space network or some heterogeneous network is infused with DTN capability. In this paper, "DTN Monitor and Control system in Deep Space Network (DSN)" exemplifies a case how DTN Monitor and Control system can be adapted into a space network as it is DTN enabled.

Bundle Status Report↗

All-digital Sensor System for Distributed Downhole Pressure Monitoring in Unconventional Fields

This project developed and validated (through field tests) a new low-cost all-digital pressure sensing technology for in situ distributed downhole pressure monitoring in unconventional oil and gas (UOG) fields. The all-digital sensing technology uses a built-in non-electric analog-to-digital converter (ADC) to transform the pressure information into a combination of binary (ON/OFF) states. As such, the system does not need downhole electronics for signal conditioning and telemetry. The all-digital sensors can be remotely logged over a long distance, and many sensors can be multiplexed for distributed sensing. Based on a review of unconventional wells in the Lower 48 states, the specification of the sensor is to measure pressure up to 69 MPa (10,000 psi) and temperature up to 250°C. A sensor with a helical bourdon sensing element and a digital signal decoder of 50 mm diameter and 109 mm length was constructed. The helical bourdon sensing element was made of 304L stainless steel and filled with motor oil. The digital converter was made up of 8 digital reading pads constructed of high-temperature epoxy with conductive inserts made of stainless steel. The sensor had a linear response to pressure with an accuracy of 0.14 MPa (20 psi). To withstand the high pressure, the sensor was enclosed in a stainless-steel pressure housing with a wall thickness of 5.5 mm, a diameter of 73 mm, and a length of 724 mm. In the laboratory tests, the sensor exhibited no temperature-related effects on the results. The sensor did not show drift over a 14-day test period at elevated pressure. A field test was conducted where the sensor was deployed in a test wellbore at the Quest drilling test facility to a depth of 0 feet over three weeks. The sensor was attached to the production rods, along with a downhole reference sensor of PPS27 type, which is a permanent downhole monitoring system. During the testing phase, the test well annular blow-out preventer was closed, and the well was pressurized at the surface to 11 MPa (1600 psi). The sensor read the elevated bottom hole pressure of 1500 psi. A multiplexing unit was created for the sensor to deploy multiple sensors on one data transmission line in a distributed approach. The multiplexing unit was tested in a simulated environment of 3048 m (10,000 ft) with five sensors distributed. The sensors were pressurized at different intervals. The multiplexed sensors recorded the correct pressure, and the multiplexing did not interfere with the readings. The proposed concept of an all-digital pressure sensor for harsh downhole environments was designed, manufactured, and tested in the laboratory and tested at the field to a up to 69 MPa and 250°C. This technology has high-temperature tolerance and has potential in downhole areas outside oil and gas, such as carbon capture and storage (CCS) and geothermal wells. The sensor concept has been proven in this project, but to create a commercially viable product, manufacturing a sensor with a smaller diameter needs to be performed.

02 PETROLEUM↗

Combining real-time monitoring and knowledge-based analysis in MARVEL

Real-time artificial intelligence is gaining increasing attention for applications in which conventional software methods are unable to meet technology needs. One such application area is the monitoring and analysis of complex systems. MARVEL, a distributed monitoring and analysis tool with multiple expert systems, was developed and successfully applied to the automation of interplanetary spacecraft operations at NASA's Jet Propulsion Laboratory. MARVEL implementation and verification approaches, the MARVEL architecture, and the specific benefits that were realized by using MARVEL in operations are described.

Schwuttke, Ursula M.↗

Fault Injection and Monitoring Capability for a Fault-Tolerant Distributed Computation System

The Configurable Fault-Injection and Monitoring System (CFIMS) is intended for the experimental characterization of effects caused by a variety of adverse conditions on a distributed computation system running flight control applications. A product of research collaboration between NASA Langley Research Center and Old Dominion University, the CFIMS is the main research tool for generating actual fault response data with which to develop and validate analytical performance models and design methodologies for the mitigation of fault effects in distributed flight control systems. Rather than a fixed design solution, the CFIMS is a flexible system that enables the systematic exploration of the problem space and can be adapted to meet the evolving needs of the research. The CFIMS has the capabilities of system-under-test (SUT) functional stimulus generation, fault injection and state monitoring, all of which are supported by a configuration capability for setting up the system as desired for a particular experiment. This report summarizes the work accomplished so far in the development of the CFIMS concept and documents the first design realization.

Torres-Pomales, Wilfredo↗

Distributed Optical Fiber Sensor Systems: Application to Natural Gas Pipeline Monitoring

Distributed fiber optic sensing is a cutting-edge technology that has found extensive applications in the monitoring of pipelines. Considering the low backscattering level of standard single-mode fiber as fiber under test, a Rayleigh enhanced optical fiber embedded within the tight-buffered cable is demonstrated in field testing. We analyzed the increased backscattering fiber cable's vibration performance to the conventional single-mode telecom fiber using a custom-built Φ-OTDR interrogator system. Thereafter, using a 4-inch steel pipeline with a flow rate of 5, 10, 15, and 20 ft/s and a fixed pressure level of 1000 psi, we field-tested the sensor system for monitoring natural gas pipeline acoustic vibrations. We also field tested Brillouin optical time domain analysis (BOTDA) system for pipeline hoop strain monitoring under various pressure conditions. The pilot-scale testing results presented in this study suggested that pipeline operators can accurately perform flow monitoring, leak detection, and pressure monitoring for pipeline integrity monitoring.

Lalam, Nageswara↗

Test and Validate Distributed Coaxial Cable Sensors for in situ Condition Monitoring of Coal-Fired Boiler Tubes

This project aims to test, validate, and advance the technology readiness level (from TRL5 to TRL7) of a novel low-cost distributed stainless-steel/ceramic coaxial cable sensing (SSC-CCS) technology for in situ monitoring of the boiler tube temperature in existing coal-fired power plants. The novel SSC-CCS sensing technology and associated condition-based monitoring (CBM) software to be demonstrated in this project will lead to an improved understanding of the boiler tube failure mechanisms and a prognostic system to improve the overall performance, reliability, and flexibility of the nation’s coal-fired power plant fleet. A boiler tube monitoring system with distributed coaxial cable temperature sensors and a sensor acquisition system was constructed. The high-temperature coaxial cable sensor with a length of 1.3m was made by using a quartz tube (1mm inner diameter (ID) and 6mm outer diameter (OD)) to concentrically separate a 304 stainless-steel (SS) rod (1mm OD) and SS tube (7.94mm OD and 6.16mm ID). The sensor acquisition system includes a vector network analyzer (VNA), a radio frequency (RF) power amplifier, multiple switches and a USB hub. The distributed stainless-steel quartz coaxial cable sensor (SSQ-CCS) had a linear response to temperature with a resolution uncertainty of σ = 0.77℃. To withstand the harsh conditions of 3,300 steam pressures and 800℃ high temperatures, the sensor was shielded by a protective tube made of the same material as the boiler tube. The protection tube had an OD of 1.5 inches and a thickness of 0.25 inches. In the laboratory tests, the sensor showed good sensitivity and fast response. The drift was bounded between +0.33% and -0.67% during a test at 600℃ for 350 hours, indicating good stability of the sensor. A field test was conducted where four sensors were welded on four superheat tubes (SH-Ts) at a coal-fired power station over 400 days. Conventional thermocouples were welded to the superheater tubes alongside the coaxial cable sensors for the purpose of comparison. Two sensors were capable of distributed sensing, with three multiplexed sensing sections. The other two sensors were single section. During the 400-day test period, the power plant experienced startups and shutdowns. At the steady state operations, the temperature of the boiler tube is about 600℃ (1112°F). The sensors recorded the entire coal-firing processes (start-up, steady state, and shut-down) and the glitch event. A GSM modem and a Watchdog were added to the system to ensure reliable data recording. The GSM modem sent daily messages to plant managers and Clemson team to inform the status of the sensor system. If the system was not normally working, the Watchdog would reboot the system automatically. The new coaxial cable based distributed sensing technology has been proven to be successful in both laboratory and field tests. A comprehensive four-stage multi-physics computational framework has been developed to assist the design, optimization, installation, and operation of SSQ-CCS. With the consideration of various operation conditions, we predict the distributions of flue gas temperatures within coal-fired boilers, the temperature correlation between the boiler tube and SSQ-CCS, and the safety of SSQ-CCS. A conditional-based monitoring system is implemented as well. The computational framework developed in this work can guide the future operation of coal-fired plants and other power plants for the safety prediction of boiler operations.

01 COAL, LIGNITE, AND PEAT↗

An automated system for continuous monitoring of CO 2 geosequestration using multi-well offset VSP with permanent seismic sources and receivers: Stage 3 of the CO2CRC Otway Project

Time-lapse seismic is an essential tool for monitoring CO 2 injection into the subsurface but suffers from high cost and long intervals between surveys. An alternative approach is continuous monitoring using permanent sources and receivers capable of mapping CO 2 plume evolution on an almost daily basis and drastically reduce human effort, cost and survey turnaround. As part of the CO2CRC Otway project, a continuous monitoring system is employed to monitor a small (15,000 tonnes) CO 2 injection within the CO2CRC Otway Project. The permanent monitoring system employs distributed acoustic sensors (DAS) installed in boreholes as seismic receivers and seismic orbital vibrators (SOV) as seismic sources. The monitoring approach is based on vertical seismic profiling using five wells equipped with DAS cemented behind the casing and nine SOVs and is acquiring the data continuously in an autonomous manner. The data is then automatically processed on-site producing a seismic image every 2.5 days, which is then transmitted to a remote office. The data has good repeatability with NRMS of about ~10-15%.

58 GEOSCIENCES↗

Mining Smart Meter Data to Enhance Distribution Grid Observability for Behind-the-Meter Load Control: Significantly improving system situational awareness and providing valuable insights

Distributed Energy Resources (DERs) are playing an increasingly important role in power systems. In 2023, five categories of DERs-distributed solar, electric vehicles (EVs), energy storage, residential smart thermostats, and small-scale combined heat and power-are expected to contribute about 104 GW to the U.S. summer peak (see GTM, 2018). With the increasing integration of DERs in power distribution systems, distributed load control is imperative to smooth the fluctuations that they introduce. However, a main challenge is that distribution systems lack systematic situational awareness because of their limited sensors. Furthermore, most customer-level behind-the-meter (BTM) DERs, such as rooftop photovoltaics (PVs), are being integrated into distribution systems, which complicates the system monitoring and control. Furthermore, enhanced electric grid monitoring is needed to promote renewable integration while ensuring reliability, but current approaches rely on expensive sensors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Impact Detector System (DIDS) Health Monitoring System Evaluation

Damage due to impacts from micrometeoroids and orbital debris is one of the most significant on-orbit hazards for spacecraft. Impacts to thermal protection systems must be detected and the damage evaluated to determine if repairs are needed to allow safe re-entry. To address this issue for the International Space Station Program, Langley Research Center and Johnson Space Center technologists have been working to develop and implement advanced methods for detecting impacts and resultant leaks. LaRC funded a Small Business Innovative Research contract to Invocon, Inc. to develop special wireless sensor systems that are compact, light weight, and have long battery lifetimes to enable applications to long duration space structures. These sensor systems are known as distributed impact detection systems (DIDS). In an assessment, the NASA Engineering and Safety Center procured two prototype DIDS sensor units to evaluate their capabilities in laboratory testing and field testing in an ISS Node 1 structural test article. This document contains the findings of the assessment.

Prosser, William H.↗