Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distributed fault detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Detection of High-impedance Arcing Faults in Radial Distribution DC Systems

High voltage, low current arcing faults in DC power systems have been researched at the NASA Glenn Research Center in order to develop a method for detecting these 'hidden faults', in-situ, before damage to cables and components from localized heating can occur. A simple arc generator was built and high-speed and low-speed monitoring of the voltage and current waveforms, respectively, has shown that these high impedance faults produce a significant increase in high frequency content in the DC bus voltage and low frequency content in the DC system current. Based on these observations, an algorithm was developed using a high-speed data acquisition system that was able to accurately detect high impedance arcing events induced in a single-line system based on the frequency content of the DC bus voltage or the system current. Next, a multi-line, radial distribution system was researched to see if the arc location could be determined through the voltage information when multiple 'detectors' are present in the system. It was shown that a small, passive LC filter was sufficient to reliably isolate the fault to a single line in a multi-line distribution system. Of course, no modification is necessary if only the current information is used to locate the arc. However, data shows that it might be necessary to monitor both the system current and bus voltage to improve the chances of detecting and locating high impedance arcing faults

Gonzalez, Marcelo C.↗

Performance Evaluation of a Novel Sequence-Based Directional Detection Strategy for Protection of Active Distribution Networks

Directional elements are relied on to achieve selectivity in fault detection in power systems. Although such elements have been deployed successfully for many years, there is an increased need for novel methods to deal with the unique challenges of directional protection in modern distribution networks. This article analyzes the impact of inverter-based resources (IBRs) on existing directional protection methods in distribution systems. It identifies parts of such elements that pose a risk of misoperation when IBRs are used in distribution networks. The authors have developed a new directional detection method for unbalanced faults in such networks using superimposed symmetrical sequence quantities. The phase angle of the superimposed negative sequence admittance is used to determine fault direction. The paper also presents a real-time co-simulation platform between a simulated distribution system and physical protection relay, using OPAL-RT. An SEL-411L relay is used to program the detection algorithm. This hardware-in-the-loop (HIL) setup is used to verify the performance of the method and the results are compared with existing directional methods

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sensors with Intelligent Measurement Platform and Low-cost Equipment (SIMPLE) for Monitoring and Control of Medium Voltage Distribution Systems with High Penetration of Intermittent Distributed Energy Resources

The primary focus of the SIMPLE project was to develop, commission, test and introduce intelligent voltage and current sensor platform with enhanced characteristics (accuracy, bandwidth and harmonic range) and high measurement granularity for medium voltage distribution system monitoring, protection and control. The enhancements incorporated existing (commercially available) sensors and made them suitable for applications such as voltage regulation, frequency support, fault detection and location, distribution system state estimation, power quality measurements and electrical distribution network topology processing. The development of the intelligent sensor platform was driven by the need for high-fidelity monitoring and control of medium voltage distribution feeder to enable higher penetration of renewable resources and microgrid operation.

14 SOLAR ENERGY↗

Distribution power system fault control apparatus and method

A method includes detecting a fault in a grid coupled to a distribution power network, the distribution power network comprising a distribution feeder, a plurality of distributed energy resources (DERs) coupled to the distribution feeder and a reference point of applicability (RPA) associated with the plurality of DERs, and in response to detecting the fault, determining an error voltage at the RPA, converting the error voltage into an error signal, broadcasting the error signal to the plurality of DERs, and based on the error signal, reducing the error voltage at the RPA by injecting a plurality of currents from the plurality of DERs to the distribution feeder.

Cintuglu, Mehmet H.↗

Fault injection experiments using FIAT

The results of several experiments conducted using the fault-injection-based automated testing (FIAT) system are presented. FIAT is capable of emulating a variety of distributed system architectures, and it provides the capabilities to monitor system behavior and inject faults for the purpose of experimental characterization and validation of a system's dependability. The experiments consist of exhaustively injecting three separate fault types into various locations, encompassing both the code and data portions of memory images, of two distinct applications executed with several different data values and sizes. Fault types are variations of memory bit faults. The results show that there are a limited number of system-level fault manifestations. These manifestations follow a normal distribution for each fault type. Error detection latencies are found to be normally distributed. The methodology can be used to predict the system-level fault responses during the system design stage.

Barton, James H.↗

Adaptive Fault Detection Based on Neural Networks and Multiple Sampling Points for Distribution Networks and Microgrids

Smart networks such as microgrid (MG) and active distribution networks (ADN) have been recently playing an important role in power system operation. The design and implementation of appropriate protection systems for such networks must be addressed, which imposes new technical challenges. This paper presents the implementation and validation aspects of an adaptive fault detection strategy based on neural networks (NNs) and multiple sampling points for ADN and MG. The solution is implemented on an edge device. Artificial NNs are used to derive a data-driven model that uses only local measurements to detect fault states of the network without the need for communication infrastructure. Multiple sampling points are used to derive a data-driven model, which allows the generalization considering the implementation in physical systems. The adaptive fault detector model is implemented on a Jetson Nano system, which is a single-board computer (SBC) with a small Graphic Processing Unit (GPU) intended to run machine learning loads at the edge. The proposed method is tested in a physical, real-life, low-voltage network located at Universidad del Norte, Colombia. This testing network is based on the IEEE-13 Node Test Feeder scaled down to 220 V. The validation in a simulation environment shows the accuracy and dependability above 99.6%, while the real-time tests show the accuracy and dependability of 95.5% and 100%, respectively. Without hard-to-derive parameters, the easy-to-implement embedded model highlights the potential for real-life applications.

42 ENGINEERING↗

End-to-end microgrid protection using distributed data-driven methods

This paper introduces an end-to-end microgrid protection framework that offers real-time system monitoring, fault-related decision making, and circuit breaker control. This is achieved through the design of distributed data-driven techniques based on the support vector machine method, where each relay is responsible for distributed data collection, fault detection, fault localization, and fault isolation. Local communication is established among neighboring relays, fostering cooperative fault localization and isolation. This decentralized design not only reduces the computational and communication requirements but also enables the adaptability of each relay under varying operational dynamics. The proposed end-to-end protection framework was validated using MATLAB/Simulink simulations on a 100% renewable microgrid, achieving an accuracy of 93.1% with response time of 0.0523 s, in protecting against a range of fault scenarios that are characterized by various types, locations, impedances, load conditions, photovoltaic power levels, and microgrid operating modes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High Impedance Fault Detection Through Quasi-Static State Estimation: A Parameter Error Modeling Approach

This paper presents a model for detecting high impedance faults using parameter error modeling and a two step per-phase weighted-least squares state estimation process. The proposed scheme leverages the use of Phasor Measurement Units and synthetic measurements to identify per-phase power flow and injection measurements which indicate a parameter error through ?2 Hypothesis Testing applied to the composed measurement error. Although current and voltage waveforms are commonly analyzed for high-impedance fault detection, wide area power flow and injection measurements, which are already inherent to the state estimation process, also show promise for real-world high-impedance fault detection applications. The error distributions after detection share the measurement function error spread observed in proven parameter error diagnostics and can be applied to high-impedance fault identification. Further, this error spread across measurement functions related to the fault will be clearly discerned from measurement error. Case studies are performed on the IEEE 33-Bus Distribution System along with the proposed model in Simulink.

Cooper, Austin↗

Online Detection of Inter-Turn Winding Faults in Single-Phase Distribution Transformers Using Smart Meter Data

Turn-to-turn faults between primary windings due to insulation degradation are a major cause of distribution transformer failure, and occur due to high levels of stress such as overloading and overheating. An additional consequence of these faults is an increased voltage on the transformer secondary due to effective change in turns ratio. This paper develops a novel method for early detection of insulation degradation and subsequent inter-turn winding failure by monitoring the transformer secondary voltage. The algorithm is based on a cumulative sum (CUSUM) statistic and compares voltages on neighbouring transformers to flag degrading assets. Results obtained from simulation as well as experimental data show that smart meter measurements can be utilized to achieve very high detection accuracy while keeping costs low. Here, the paper also demonstrates the validity of the algorithm in the presence of measurement noise, residential solar power injection etc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Sensor Deployment for Distribution System State Estimation and Fault Identification

Distribution systems are currently facing steep operational challenges as a result of the rapidly increasing integration of renewables and other distributed energy resources (DERs) at both the primary and secondary circuit levels. Distribution utilities and system operators have traditionally had some visibility of their primary circuits using low-frequency supervisory control and data acquisition systems, and they have had very poor if not zero visibility of the secondary circuits where the presence of DERs is constantly increasing. Therefore, this paper presents simulation studies to demonstrate the benefits of an advanced, high-fidelity sensor technology, called as the Meta-Alert System (MAS), developed by Electrical Grid Monitoring, Ltd. (EGM), on the distribution grid. First, a reliable model of the EGM sensors is developed, and then two use cases, distribution system state estimation (DSSE) and fault identification are simulated to evaluate the performance of the MAS technology. Simulation results on the Electric Power Research Institute J1 feeder demonstrate that the MAS can effectively participate in system-level DSSE programs and can detect and locate faults faster than traditional distribution protection schemes.

distribution system↗

Soft-Fault Detection Technologies Developed for Electrical Power Systems

The NASA Glenn Research Center, partner universities, and defense contractors are working to develop intelligent power management and distribution (PMAD) technologies for future spacecraft and launch vehicles. The goals are to provide higher performance (efficiency, transient response, and stability), higher fault tolerance, and higher reliability through the application of digital control and communication technologies. It is also expected that these technologies will eventually reduce the design, development, manufacturing, and integration costs for large, electrical power systems for space vehicles. The main focus of this research has been to incorporate digital control, communications, and intelligent algorithms into power electronic devices such as direct-current to direct-current (dc-dc) converters and protective switchgear. These technologies, in turn, will enable revolutionary changes in the way electrical power systems are designed, developed, configured, and integrated in aerospace vehicles and satellites. Initial successes in integrating modern, digital controllers have proven that transient response performance can be improved using advanced nonlinear control algorithms. One technology being developed includes the detection of "soft faults," those not typically covered by current systems in use today. Soft faults include arcing faults, corona discharge faults, and undetected leakage currents. Using digital control and advanced signal analysis algorithms, we have shown that it is possible to reliably detect arcing faults in high-voltage dc power distribution systems (see the preceding photograph). Another research effort has shown that low-level leakage faults and cable degradation can be detected by analyzing power system parameters over time. This additional fault detection capability will result in higher reliability for long-lived power systems such as reusable launch vehicles and space exploration missions.

Button, Robert M.↗

Long–short-term memory encoder–decoder with regularized hidden dynamics for fault detection in industrial processes

The ability of recurrent neural networks (RNN) to model nonlinear dynamics of high dimensional process data has enabled data-driven RNN-based fault detection algorithms. Previous studies have focused on detecting faults by identifying the discrepancies in data distribution between the faulty and normal data, as reflected in prediction errors generated by RNN models. However, in industrial processes, variations in data distribution can also result from changes in normal control setpoints and compensatory control adjustments in response to disturbances, making it hard to differentiate between normal and faulty conditions. This paper proposes a fault detection method utilizing a long short-term memory (LSTM) encoder–decoder structure with regularized hidden dynamics and reversible instance normalization (RevIN) to compactly represent high-dimensional measurements for effective monitoring. During training, the hidden states of the model are regularized to form a low-dimensional latent space representation of the original multivariate time series data. As a result, the prediction errors of the latent states can be used to monitor the abnormal dynamic variations, while the reconstruction errors of the measured variables are used to monitor the abnormal static variations. Furthermore, the proposed indices can reflect operating conditions, even when the distribution of test data changes, which helps distinguish faults from normal adjustments and disturbances that controllers can settle. Here, data from numerical simulation and the Tennessee Eastman process are used to illustrate the effectiveness of the proposed fault detection method.

42 ENGINEERING↗

Architectures for fault-tolerant spacecraft computers

This paper summarizes the results of a long-term research program in fault-tolerant computing for spacecraft on-board processing. In response to changing device technology this program has progressed from the design of a fault-tolerant uniprocessor to the development of fault-tolerant distributed computer systems. The unusual requirements of spacecraft computing are described along with the resulting real-time computer architectures. The following aspects of these designs are discussed: (1) architectural features to minimize complexity in the distributed computer system, (2) fault-detection and recovery, (3) techniques to enhance reliability and testability, and (4) design approaches for LSI implementation.

Rennels, D. A.↗

Flight elements subpanel

A summary of findings of the Flight Elements Subpanel is given in viewgraph form. Topics covered include advanced avionics architecture; processors; integrated Global Positioning System and guidance, navigation and control; displays and controls; telemetry; sensors and instrumentation; fault detection and management; electrical power distribution and control; spacecraft power supplies; and in-flight crew training.

Keckler, Claude R.↗

1393 Ring Bus at JPL: Description and Status

Completed Ring Bus IC V&V Phase - Ring Bus Test Plan Completed for SIM Project - Applicable to Other Projects Implemented a Avionics Bus Based upon the IEEE 1393 Standard - Excellent Starting Point for a General Purpose High-Speed Spacecraft Bus - Designed to Meet SIM Requirements for - Real-time deterministic, distributed systems. - Control system requirements - Fault detection and recovery Other JPL Projects Considering Implementation F'light Software Ring Bus Driver Module Began in 2006, Continues Participating in Standard Revision. Search for Earth-like planets orbiting nearby stars and measure the masses and orbits of the planets it finds. Survey 2000 nearby stars for planetary systems to learn whether our Solar System is unusual, or typical. Make a new catalog of star position 100 times more accurate than current measurements. Learn how our galaxy formed and will evolve by studying the dynamics of its stars. Critically test models of exactly how stars shine, including exotic objects like black holes, neutron stars and white dwarfs.

time synchronization↗