Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distributed energy resource integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The Impact of Behind-the-Meter Heterogeneous Distributed Energy Resources on Distribution Grids

The increasing integration of distributed energy resources (DERs) on the electric grid brings new challenges and opportunities for utility grid operations. With the rapid deployment of DERs, there is emerging interest in integrating these controllable devices with utility operations at all levels for monitoring and management. To understand the challenges with increasing behind-the-meter (BTM) DERs and to identify the needs in deploying advanced controls, a comprehensive grid impact study is indispensable. This paper presents the analysis which help visualize the DER impact on the grid, identify the challenges and provides an insight into the new distribution management and control needs to enable reliable and resilient grid operations.

behind-the-meter↗

Distributed Energy Resource (DER) Integration Framework: Regulatory Innovation for DER Compensation and Cost Allocation

Existing regulatory approaches to DER lack the precision and granularity necessary to ensure that DER can continue to scale in a cost-effective manner that is aligned with the public interest. To address this need, with the support of the U.S. Department of Energy’s Office of Electricity, Berkeley Lab and Current Energy Group developed an illustrative regulatory framework. By adopting a technology-neutral and modular approach, the framework enables flexibility and scalability for DER providers, utilities, and regulators. Clear price signals and incentives encourage the provision of valuable grid services, while equitable cost allocation promotes efficient use of distribution capacity and interconnection resources. This approach mirrors traditional ratemaking principles for importing customers and positions DERs as integral components of a dynamic and cost-effective energy future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Voltage Reference for Droop-Based DERs in Distribution Systems

Due to the newly issued standards on distributed energy resources (DERs), the droop-based operation modes (Q-V and P-V droops) become a requirement for all the interconnected DER units at the distribution level. Voltage references of the DER units can be assigned to improve the operational behavior of the distribution system in the smart grid context. This paper presents a novel formulation for optimally setting voltage reference of the droop-based DER units in distribution systems with the objective of minimizing the system ohmic loss. This problem is formulated as a mixed-integer quadratic convex optimization problem in MATLAB and solved by the MATLAB and CPLEX solvers. The IEEE 123-bus system and the EPRI test system Ckt5 are used to validate the proposed formulation. The result obtained from the proposed formulation is compared with the result of the original problem solved by the heuristic method. Based on the numerical study results, system loss can be reduced after the proposed voltage reference assignment. The computational expense of the new formulation is also much lower than that of the heuristic approach.

distributed energy resource integration↗

Evolution of Distributed Energy Resource Grid Interconnection Standards for Integrating Emerging Storage Technologies

Grid interconnection standards facilitate safe and reliable grid integration of distributed energy resources (DERs). Evolution of a standard for DERs is expected to capture and accommodate widely different characteristics of DER and minimize unique grid integration challenges. This makes development of a uniform grid interconnection standard for all types of DERs a challenging and an ever-evolving consideration. This paper presents a detailed timeline of evolution, from the early 2000s to 2018, of DER interconnection standards and the research that informed their development. This is followed by a review of the research topics being considered in the grid integration of Energy Storage Systems (ESSs) which are expected to have the most significant growth amongst all DER types. These help in highlighting the need for a new standard to accommodate the unique characteristics of ESSs, and where the existing DER interconnection standard frameworks may be leveraged.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integration of Utility Distributed Energy Resource Management System and Aggregators for Evolving Distribution System Operators

With the rapid integration of distributed energy resources (DERs), distribution utilities are faced with new and unprecedented issues. New challenges introduced by high penetration of DERs range from poor observability to overload and reverse power flow problems, under-over-voltages, maloperation of legacy protection systems, and requirements for new planning procedures. Distribution utility personnel are not adequately trained, and legacy control centers are not properly equipped to cope with these issues. Fortunately, distribution energy resource management systems (DERMSs) are emerging software technologies aimed to provide distribution system operators (DSOs) with a specialized set of tools to enable them to overcome the issues caused by DERs and to maximize the benefits of the presence of high penetration of these novel resources. However, as DERMS technology is still emerging, its definition is vague and can refer to very different levels of software hierarchies, spanning from decentralized virtual power plants to DER aggregators and fully centralized enterprise systems (called utility DERMS). Although they are all frequently simply called DERMS, these software technologies have different sets of tools and aim to provide different services to different stakeholders. This paper explores how these different software technologies can complement each other, and how they can provide significant benefits to DSOs in enabling them to successfully manage evolving distribution networks with high penetration of DERs when they are integrated together into the control centers of distribution utilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Vulnerability Detection Methodology for a Digital Signal Processor Micro-Controller at Edge Level Distributed Energy Resource Controller

Integration of renewable energy and energy storage based Distributed Energy Resource (DER) assets to the grid has seen an upsurge over the past few decades. Traditionally, energy would be generated at a thermal or nuclear power plant and then transmitted over long distance through the transmission grid and then supply to the customers at the distribution grid. Modern renewable energy based DER assets have brought energy production at the edge of distribution grid, which has made the grid vulnerable to cyber intrusion as the power flow controllers for such DER assets are now distributed across the grid from distribution level to transmission level. This paper discusses the vulnerability posed by such power flow controllers of DER assets and demonstrates a detection methodology for unauthorized access and manipulation of system configuration for Digital Signal Processor based Microcontrollers. Experimental results proving efficacy of the methodology have been shown in paper.

Bhowmik, Pankaj↗

The Impact of Behind-the-Meter Heterogeneous Distributed Energy Resources on Distribution Grids

The increasing integration of distributed energy resources (DERs) on the electric grid brings new challenges and opportunities for utility grid operations. With the rapid deployment of DERs, there is emerging interest in integrating these controllable devices with utility operations at all levels for monitoring and management. To understand the challenges with increasing behind-the-meter (BTM) DERs and to identify the needs in deploying advanced controls, a comprehensive grid impact study is indispensable. This paper presents the analysis which help visualize the DER impact on the grid, identify the challenges and provides an insight into the new distribution management and control needs to enable reliable and resilient grid operations.

27 ARPA - Advanced Research Projects Agency-Energy↗

The Impact of Behind-the-Meter Heterogeneous Distributed Energy Resources on Distribution Grids: Preprint

The increasing integration of distributed energy resources (DERs) on the electric grid brings new challenges and opportunities for utility grid operations. With the rapid deployment of DERs, there is emerging interest in integrating these controllable devices with utility operations at all levels for monitoring and management. Different types of DERs such as Photovoltaics (PV), energy storage, electric vehicles (EVs), etc. have varying effects on the grid based on how and where they are deployed. Again, the DER deployment and its impact are network-dependent, while the traditional electric grids were not designed to host DERs. To understand the challenges with increasing behind-the-meter (BTM) DERs and to identify the needs in deploying advanced controls, a comprehensive grid impact study is indispensable. This paper investigates the impacts of integrating a mix of DERs in the utility distribution network in Colorado, U.S. Firstly, BTM DERs at the residential scale including distributed PV; battery energy storage systems (BESS); heating, ventilation, and air-conditioning (HVAC) load; electric water heater (EWH) load; and EVs are modeled. The impacts of integrating these resources on the distribution network are evaluated by conducting time-series simulations for different scenarios considering different days to capture the worst-case conditions. Monte Carlo simulations are conducted to generate the realistic EV charging profile. The voltage issues, substation transformer loadings, and critical nodes in the network are identified with the incorporation of uncoordinated EV charging loads and other DER in the network. This analysis helps visualize the DER impact on the grid, identify the challenges, and provides an insight into the new distribution management and control needs to enable reliable and resilient distribution grid operations. Additionally, further analysis is performed to estimate the daily residential electricity cost with the inclusion of DERs under time-of-use tariffs. The result shows the daily residential electricity cost reduced by 20:7% on average with DERs compared to the case without DERs.

27 ARPA - Advanced Research Projects Agency-Energy↗

A 1kV, 480V Power Electronics Hub for DER Integration in Commercial Buildings

Power electronic (PE) systems are increasingly being integrated into distribution and sub-distribution networks in support of distributed energy resource integration (DERs), electric vehicle (EV) charging (particularly in the case of fast charging infrastructure), and improvement in power quality for high performance computing and/or servers farms. This provides an opportunity to research and develop integrated PE systems that can function as single systems thereby bringing additional functionality and benefits to the overall system. The goal of this paper is to demonstrate foundational technologies and capabilities for a multiport power electronics energy hub that can intelligently coordinate and control integrated sources and loads. The focus for this digest is on a commercial building use case which is demonstrated in hardware.

Starke, Michael↗

Providencia Island White Papers: Hawaii, USA: A Grid Planning Case Study for Providencia Island, Colombia

Special considerations exist for island grids seeking to smoothly integrate distributed energy resources (DERs), such as rooftop photovoltaics (PV), with an existing fossil fuel-based grid without compromising system stability and reliability. Hawaii, having successfully integrated nonconventional renewable energy sources for a hybrid electricity grid, may serve as a guide for technical specifications and interconnection policy. Island grid planners may seek to follow Hawaii's example by standardizing technical specifications of generators, particularly for advanced inverter components.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analyzing at-scale distribution grid response to extreme temperatures

Threats against power grids continue to increase, as extreme weather conditions and natural disasters (extreme events) become more frequent. Hence, there is a need for the simulation and modeling of power grids to reflect realistic conditions during extreme events conditions, especially distribution systems. Herein, this paper presents a modeling and simulation platform for electric distribution grids which can estimate overall power demand during extreme weather conditions. The presented platform's efficacy is shown by demonstrating estimation of electrical demand for 1) Electricity Reliability Council of Texas (ERCOT) during winter storm Uri in 2021, and 2) alternative hypothetical scenarios of integrating Distributed Energy Resources (DERs), weatherization, and load electrification. In comparing to the actual demand served by ERCOT during the winter storm Uri of 2021, the proposed platform estimates approximately 34 GW of peak capacity deficit. These numbers are consistent with state-of-the-art prediction results published in the literature. For the case of the future electrification of heating loads, peak capacity of 78 GW (124% increase) is estimated, which would be reduced to 47 GW (38% increase) with the adoption of efficient heating appliances and improved thermal insulation. Integrating distributed solar PV and storage into the grid causes improvement in the local energy utilization and hence reduces the potential unmet energy by 31% and 40%, respectively.

24 POWER TRANSMISSION AND DISTRIBUTION↗

POWER ELECTRONICS GRID TIED SYSTEM FINAL REPORT

Across the country, electric utilities are grappling with the persistent hurdles of integrating Distributed Energy Resources (DERs). Managing these assets safely and effectively is a complex endeavor, complicated by varying ownership structures, management philosophies, and the diversity of the technologies themselves. Consequently, the industry has seen a proliferation of bespoke system designs, control strategies, and communication frameworks—forcing utilities to spend significant time and resources developing one-off integration solutions. This project addressed these integration hurdles through a scalable demonstration of intelligent devices designed to coordinate and control diverse resources in low-voltage applications. This concept minimized the need for complex integration by transforming the separate DERs into a dispatchable virtual power plant (VPP) with integrated resiliency functions (called a Node). By collaborating with a utility partner, the project focused on developing rapidly implementable use cases that bridged the gap between theoretical control and real-world deployment

99 GENERAL AND MISCELLANEOUS↗

A digital twin platform for building performance monitoring and optimization: Performance simulation and case studies

Advancements in sensor technology, data analytics, affordable compute, and communication infrastructure have paved the way for Digital Twin technology in optimizing building operations and controls. This study presents the development of an open and interoperable web-based Digital Twin platform for integrating diverse data streams and facilitating effective user interactions. The platform utilizes modern technologies for the web framework and time-series data management, ensuring scalability and responsiveness. The backend supports seamless integration of diverse data sources and emulators, incorporating data from building sensors and meters, external weather Application Programming Interfaces, and advanced EnergyPlus simulation models of the building and its energy systems including the Distributed Energy Resources that are formulated in Functional Mockup Units. A simulation case study was conducted with FlexLab, a test facility on Lawrence Berkeley National Laboratory campus. The case study includes normal operations, Distributed Energy Resource integration, and power outage scenarios, to illustrate the Digital Twin’s ability to provide critical insights into energy performance and thermal resilience. The results demonstrated the platform’s potential as a decision-support tool for optimizing building energy performance and enhancing resilience against extreme weather events. Future work will focus on deploying the Digital Twin platform to a real building for field validation, extending its capabilities to cover more scenarios such as bidirectional Electric Vehicle interactions, and enhancing user engagement.

EnergyPlus↗

Development of a DC Distribution Testbed for High-Power EV Charging

This paper explores the design and implementation of a power hardware-in-the-loop (P-HIL) setup for DC distribution infrastructure integrated with high-power charging (HPC) of electric vehicles (EVs), DC loads, and sources. The utilization of DC distribution holds significant potential for enhancing the operation of a HPC station architecture. However, there are challenges establishing a DC charging hub including interoperability, commoditization, distributed energy resource integration, stability, DC protection, and lack of common system level controllers. To address these challenges, a testing setup is required that accommodates commercial off-the-shelf (COTS) products to evaluate different use cases at rated power and voltage levels. The developed P-HIL setup features a dedicated DC charging hub, DC-coupled chargers, DC loads/sources, DC protection, and a communication architecture. The integrated P-HIL system provides a versatile testing environment to address technology and interoperability gaps and implements a smart energy management system (SEMS). This platform enables comprehensive and robust testing of COTS devices, charger prototypes, SEMS controllers and protection schemes, which together will accelerate transition to EVs at scale. The setup is tested for various use-cases at full-scale, integrating 950 V DC bus voltage, 660 kW grid-tied inverter, 150 kW COTS charger, and 100 kW energy storage system within an open-source SEMS platform.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

High-Power Electric Vehicle Charging Hub Integration Platform (eCHIP): Design Guidelines and Specifications for DC Distribution-Based Charging Hub

Managed under U.S. Department of Energy (DOE)-funded EVs@Scale Consortium, High-Power Electric Vehicle Charging Hub Integration Platform (eCHIP) project aims to design and develop a high-power, interoperable charging experimental platform to research, develop, and demonstrate the integration and control approaches for a DC distribution-based high-power charging (HPC) system. The eCHIP project addresses the crucial need to design and validate efficient, low-cost, reliable, and interoperable solutions for DC-coupled charging hub ('DC hub' for short). This report explains the design, development, and implementation process of the experimental platform for the DC hub. The utilization of DC distribution holds significant potential for enhancing the operation of an HPC station architecture. However, there are challenges establishing the DC hub, including interoperability, commoditization, distributed energy resource integration, stability, DC protection, and lack of common system level controllers. To address these challenges, a testing setup is required that accommodates commercial off-the-shelf (COTS) products as well as novel, in-house designed solutions to evaluate different use cases at rated power and voltage levels.

33 ADVANCED PROPULSION SYSTEMS↗

EVs@Scale Lab Consortium High-Power Charging Pillar Deep-Dive Technical Meeting

Managed under the the U.S. Department of Energy (DOE)-funded EVs@Scale Consortium, the High-Power Electric Vehicle Charging Hub Integration Platform (eCHIP) project aims to create an experimental platform for integration and control approaches in a direct current (DC), distribution-based high-power charging (HPC) system. The eCHIP project addresses the crucial need to design and validate efficient, low-cost, reliable, and interoperable solutions for a DC-coupled charging hub ("DC hub" for short). This report explains the design, development, and implementation process of an experimental platform for the DC hub. DC distribution holds significant potential for enhancing the operation of an HPC station architecture. However, there are challenges in establishing a DC hub, including interoperability, commoditization, distributed energy resource integration, stability, DC protection, and a lack of common system-level controllers. To address these challenges, a testing setup is required that accommodates commercial off-the-shelf (COTS) products, as well as novel, in-house designed solutions, to evaluate different use cases at rated power and voltage levels. The developed proof-of-concept charging platform and open-source SEMS allow the development and testing of various controllers and chargers from different vendors. The DC hub platform integrated EVs, an ESS, a PV system, and building load to demonstrate the flexibility of the platform. The open-source SEMS controlled the devices within the hub using a rule-based implementation, realizing available standards.

ADVANCED PROPULSION SYSTEMS↗

Solid State Power Substation DC Node Optimization and Controller Hardware-In-The-Loop Demonstration

A solid state power substation (SSPS) node is a microgrid that integrates distributed energy resources and loads and injects/absorbs power to/from the SSPS distribution network. It is an essential building block of a futuristic distribution grid network. This paper presents the development and demonstration of optimization use cases of a SSPS DC node. By adopting multi-layer hierarchical control architecture and developing automatic device identification and dynamic optimization formulation algorithms, the SSPS DC node can perform plug-and-play resource integration and seamless transition of the optimized node operation under on and off grid condition without sophisticated algorithms, control mode changes, and user interactions. Four optimization use cases including economic dispatches with price signal changes, a sudden PV power drop, and a single directional meter and its associated costs with sending power back to the grid, and resiliency under a grid inverter trip condition were demonstrated through the real-time controller hardware-in-the-loop simulation.

Kim, Namwon↗