Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “directional airflow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Method and apparatus for reduction of water re-evaporation in a dedicated dehumidifier/water heater

An apparatus that includes a refrigeration circuit that includes an evaporator, a first condenser and a compressor. The apparatus includes a refrigerant-water heat exchanger that includes a second condenser fluidly coupled to the refrigeration circuit. A control valve is operatively connected to the refrigeration circuit to direct flow of refrigerant through at least one of the first condenser during a dehumidification mode and the second condenser during a water heating mode. A damper is disposed on an upwind side of the evaporator, the damper being operable to reduce airflow across the evaporator during a ventilation mode.

Uselton, Robert B.↗

Numerical Modeling of Atmospheric Rime Ice Accretion on an Airfoil Using an Eulerian Approach

This paper presents an approach to numerically simulate the inherently unsteady rime ice accretion problem on a two-dimensional airfoil and elucidate the associated variations under different icing conditions. The airflow field and the water impingement on the airfoil are obtained based on an Eulerian two-phase model. A dynamic mesh strategy is employed to unsteadily account for the changes in the ice profile and its impact on the air and droplet flow by continuously reconstructing the computational grid at each time-step through smoothing and layering mechanisms. All main icing modules including the airflow field, droplet trajectory, icing thickness profile, and mesh management are fully coupled within the same computational framework without resorting to any external tools. Classical icing theory is employed to model the rime ice roughness, and it is assumed that the ice accretes in a direction normal to the airfoil surface. The governing Reynolds-averaged Navier–Stokes (RANS) conservation equations along with the energy and continuity equations are solved to produce the velocity and temperature fields. A convective film heat transfer coefficient is computed based on the surface heat flux and a recovery temperature which takes into account the dissipative heat release in the boundary layer in the vicinity of the airfoil surface. With the implemented strategy and calculating the convective heat transfer coefficient, the water film thickness is also calculated along with the ice shape. Furthermore, the model is validated by comparing the local collection efficiency distribution and ice shape with experimental data, and the results show that the implemented approach provides acceptable predictions of ice accretion profiles and rates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The mechanisms and seasonal differences of the impact of aerosols on daytime surface urban heat island effect

The urban heat island intensity (UHII) is the temperature difference between urban areas and their rural surroundings. It is commonly attributed to changes in the underlying surface structure caused by urbanization. Air pollution caused by aerosol particles can affect the UHII through changing (1) the surface energy balance by the aerosol radiative effect (ARE) and (2) planetary-boundary-layer (PBL) stability and airflow intensity by modifying thermodynamic structure, which is referred to as the aerosol dynamic effect (ADE). By analyzing satellite data and ground-based observations collected from 2001 to 2010 at 35 cities in China and using the WRF-Chem model, we find that the impact of aerosols on UHII differs considerably: reducing the UHII in summer but increasing the UHII in winter. This seasonal contrast is proposed to be caused by the different strengths of the ARE and ADE between summer and winter. In summer, the ARE on UHII is dominant over the ADE, cooling down surface temperature more strongly in urban areas than in rural areas because of much higher aerosol loading, and offsets the urban heating, therefore weakening UHII. In winter, however, the ADE is more dominant, because aerosols stabilize the PBL more in the polluted condition, weakening the near-surface heat transport over urban areas in both vertical and horizontal directions. This means that the heat accumulated in urban areas is dispersed less effectively, and thus the UHII is enhanced. These findings shed new light on the impact of the interaction between urbanization-induced surface changes and air pollution on urban climate.urban areas and their rural surroundings. It is commonly attributed to changes in the underlying surface structure caused by urbanization. Air pollution caused by aerosol particles can affect the UHII through changing (1) the surface energy balance by the aerosol radiative effect (ARE) and (2) planetary-boundary-layer (PBL) stability and airflow intensity by modifying thermodynamic structure, which is referred to as the aerosol dynamic effect (ADE). By analyzing satellite data and ground-based observations collected from 2001 to 2010 at 35 cities in China and using the WRF-Chem model, we find that the impact of aerosols on UHII differs considerably: reducing the UHII in summer but increasing the UHII in winter. This seasonal contrast is proposed to be caused by the different strengths of the ARE and ADE between summer and winter. In summer, the ARE on UHII is dominant over the ADE, cooling down surface temperature more strongly in urban areas than in rural areas because of much higher aerosol loading, and offsets the urban heating, therefore weakening UHII. In winter, however, the ADE is more dominant, because aerosols stabilize the PBL more in the polluted condition, weakening the near-surface heat transport over urban areas in both vertical and horizontal directions. This means that the heat accumulated in urban areas is dispersed less effectively, and thus the UHII is enhanced. These findings shed new light on the impact of the interaction between urbanization-induced surface changes and air pollution on urban climate.

54 ENVIRONMENTAL SCIENCES↗

Direct Air Capture Using Aqueous Amino Acid Solvents in a Crossflow Absorber

Carbon dioxide (CO 2 ) is the most abundant of all greenhouse gases (GHGs). CO 2 levels in the atmosphere are 50% higher than in the preindustrial era, trapping heat. CO 2 removal from the atmosphere by direct air capture (DAC) is needed to achieve the internationally agreed global temperature goals. The most common CO 2 capture technology is absorption by aminebased solvents in packed columns. Amino acid solutions have recently gained attention due to their advantages over traditional amine solvents. To be implemented effectively, DAC industrial processes need to handle large airflow rates in separation absorbers. The large air and solvent flow rates preclude the use of countercurrent columns due to high-pressure drops and the occurrence of flooding. Crossflow air−liquid absorbers are used to handle large air and liquid volumes due to their lower-pressure drop. The objective of this work is to study the influence of crossflow absorber geometric parameters and operating conditions on product formation and process efficiency. An already derived theoretical model for countercurrent absorbers has been modified to simulate the operation of a crossflow DAC absorber. The predictive model was implemented into a computer code that was used to study the efficiency of the processes as geometric equipment dimensions and operating parameters vary. Practical suggestions are made to design more efficient DAC processes.

Absorption↗

A buckling-sheet ring oscillator for electronics-free, multimodal locomotion

Locomotion of soft robots typically relies on control of multiple inflatable actuators by electronic computers and hard valves. Soft pneumatic oscillators can reduce the demand on controllers by generating complex movements required for locomotion from a single, constant input pressure, but either have been constrained to low rates of flow of air or have required complex fabrication processes. Here, we describe a pneumatic oscillator fabricated from flexible, but inextensible, sheets that provides high rates of airflow for practical locomotion by combining three instabilities: out-of-plane buckling of the sheets, kinking of tubing attached to the sheets, and a system-level instability resulting from connection of an odd number of pneumatic inverters made from these sheets in a loop. This device, which we call a “buckling-sheet ring oscillator” (BRO), directly generates movement from its own interaction with its surroundings and consists only of readily available materials assembled in a simple process—specifically, stacking acetate sheets, nylon film, and double-sided tape, and attaching an elastomeric tube. A device incorporating a BRO is capable of both translational and rotational motion over varied terrain (even without a tether) and can climb upward against gravity and downward against the buoyant force encountered under water.

Robotics↗

Residential HVAC Fault Data Collection Plan – Refrigerant Undercharge and Overcharge Faults

Heating, ventilation, and air-conditioning (HVAC) systems can develop faults due to poor installation practices or gradual wear and tear, leading to decreased HVAC system’s efficiency, compromised thermal comfort, and shortened equipment lifespan (EERE, 2018). Automated fault detection and diagnosis (AFDD) technologies offer a solution by identifying energy-wasting HVAC faults, such as inadequate indoor airflow and incorrect refrigerant charge, and guiding technicians to enhance system efficiency. In the realm of residential HVAC, AFDD can be implemented through various fault detection and diagnosis capabilities, sensor configurations, and target applications. These technologies typically fall into three categories: smart diagnostic tools, original equipment manufacturer (OEM)-embedded tools, and add-on tools. Smart diagnostic tools employ temporarily installed sensors to directly measure HVAC system characteristics, while OEM-embedded tools utilize factory-installed sensors to identify faults or assess system performance. However, both these types of AFDD technologies are often only accessible for high-end HVAC equipment or require additional sensor installation by qualified technicians, resulting in high investment costs and limited applicability for low-income residential buildings. On the other hand, add-on tools rely solely on data from smart thermostats and meters to detect faults by continuously analyzing equipment runtime or energy usage. As smart thermostat and meter costs decrease and their prevalence increases, these tools can be readily deployed in low-income residential buildings. However, they possess limited capabilities as they rely solely on basic trend analysis. Enhancing such tools with advanced machine learning algorithms can significantly improve their effectiveness.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Room Return Path Sensitivity

Standard practice for HVAC return design has evolved from running a dedicated return to each room with a supply, to systems with returns in more centrally located areas of the home with jump ducts, transfer grilles, or simply door undercuts used as return air pathways from isolated rooms. In these latter systems, hallways and stairwells act as large open ducts for conveying air back to a single (or sometimes multiple) central return. When partition doors to an isolated room are closed, the return airflow resistance goes up, significantly impacting airflow balance if an adequate relief pathway is not installed. Airflow imbalances can lead to comfort and building durability issues and increased envelope leakage. To combat this, some jurisdictions have requirements for return air pathways. The supply system topology–or layout–impacts the airflow balance stability in response to adjustments of return pathway resistances. Branching supply topologies typically have reduced static pressure after each split. The static pressure at the final split will be lower than the primary supply plenum. Because of this, if there is a restriction in a room’s return path, supply airflow will tend to redistribute to adjacent ducts at the end of the branch. A properly designed trunk and branch supply system can effectively equalize static pressure by reducing the cross sectional area after each takeoff . Maintaining static pressure within the trunk will reduce the system’s sensitivity to changes in return paths. However, in practice, it is difficult to design and time consuming to install a complex supply plenum. Velocity effects and poor takeoff placement also impact airflow balance. This report considers return systems in three main categories: distributed, with a return duct to each room; multiple central, with one return grille on each floor of a home; and single central, with a single return grille located near the air handling unit. Three supply categories are also considered: radial splitter box, trunk and branch, and home-run with all ducts connecting directly to a central manifold.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Designing for Supply and Return Air System Interaction in Residential Buildings

Standard practice for HVAC return design has evolved from running a dedicated return to each room with a supply, to systems with returns in more centrally located areas of the home with jump ducts, transfer grilles, or simply door undercuts used as return air pathways from isolated rooms . In these latter systems, hallways and stairwells act as large open ducts for conveying air back to a single (or sometimes multiple) central return. When partition doors to an isolated room are closed, the return airflow resistance goes up, significantly impacting airflow balance if an adequate relief pathway is not installed. Airflow imbalances can lead to comfort and building durability issues and increased envelope leakage. To combat this, some jurisdictions have requirements for return air pathways. The supply system topology – or layout - impacts the airflow balance stability in response to adjustments of return pathway resistances. Branching supply topologies typically have reduced static pressure after each split. The static pressure at the final split will be lower than the primary supply plenum. Because of this, if there is a restriction in a room’s return path, supply airflow will tend to redistribute to adjacent ducts at the end of the branch. A properly designed trunk and branch supply system can effectively equalize static pressure by reducing the cross sectional area after each takeoff . Maintaining static pressure within the trunk will reduce the system’s sensitivity to changes in return paths. However, in practice, it is difficult to design and time consuming to install a complex supply plenum. Velocity effects and poor takeoff placement also impact airflow balance. This fact sheet considers return systems in three main categories: distributed, with a return duct to each room; multiple central, with one return grille on each floor of a home; and single central, with a single return grille located near the air handling unit. Three supply categories are also considered: radial splitter box, trunk and branch, and home-run with all ducts connecting directly to a central manifold. A complete description of the modeling work and results can be found in the companion technical report.

buildings↗

Efficiency and emissions of NH3-diesel/bio-pilot dual-fuel combustion in a high-speed four-stroke engine

While dual-fuel ammonia engines are starting to be commercialized for the large low-speed 2-stroke marine engine market, there are still challenges with utilizing ammonia on 4-stroke engines used as auxiliary engines for ocean going vessels and within inland and coastal marine applications. The shorter timescales for high-speed engines pose a particular challenge for low-cetane, high ignition energy fuels like ammonia. In addition to achieving maximum ammonia substitution levels, N2O emissions are a key factor that needs to be understood. This paper reports the results of experiments using a single-cylinder 107mm bore Cummins B-series diesel engine modified for port-fuel injection of gaseous anhydrous ammonia with a direct injection of diesel fuel near-TDC to ignite the premixed ammonia. Combustion data as well as emissions data from an FTIR including NO, NO2, N2O, and unburned ammonia are presented for selected operating points with a focus on high-load operation at 1200rpm with high ammonia energy substitution (over 95% by fuel energy). Several air/fuel ratio conditions are included, sweeping from diesel-like airflow to stoichiometric conditions. The impact of biofuels (biodiesel and renewable diesel) as pilot fuels is also considered. Comparisons for emissions, greenhouse gas performance, and efficiency are made with a conventional diesel combustion baseline. The impact of fuel injection strategy on NOx, N2O, and NH3 emissions is quantified, and the dual-fuel ammonia results on this high-speed 4-stroke engine are expected to provide fundamental insights into further combustion development opportunities for the larger engines used across marine applications.

Kaul, Brian [ORNL] (ORCID:0000000184813620)↗

Numerical simulation of frost formation and heat transfer on fin-and-tube heat exchangers in turbulent cross-flow

Frost formation in fin-and-tube heat exchangers in turbulent cross-flow presents significant challenges in industrial refrigeration applications, affecting heat transfer efficiency and operational reliability. The purpose of this work is to investigate frost deposition and growth on a staggered bank of a fin-and-tube freezer coil under turbulent forced convection conditions. The focus here is on investigating conditions that closely replicate real-world scenarios in large walk-in industrial freezers. Using a direct numerical simulation approach, we examine the flow dynamics and thermal behaviour in the presence of frost, considering turbulent regimes characterized by a Reynolds number in the range 1050 ≤ R e D , avg ≤ 4800 , with the characteristic length being the outer diameter of the tube and the velocity being the bulk fluid velocity between the plates (fins). Computational fluid dynamics simulations are employed to resolve the interactions between turbulent airflow and the frost layer. Our approach incorporates a modified immersed boundary method and a slow-time acceleration technique to address the complex dynamic interface between the continuously evolving frost layer and the flowing air stream. Our findings indicate that frost forms more on the sides of the finned surfaces (plates) and less on the tubes themselves. This article is part of the theme issue ‘Heat and mass transfer in frost and ice’.

Science & Technology - Other Topics↗

Power Generation and Oxygen Transfer Analyses for Micro Hydro-Turbine Installed in Wastewater Treatment Aeration Tank

This study targets one of the major energy consumers in the U.S. It suggests a new mechanical system that can recover a portion of the energy in Wastewater Treatment Plants (WWTPs). The proposed system entails a hydro-turbine installed above the air diffuser in the aeration tank to extract the water-bubble current’s kinetic energy and converts it to electricity. Observing the optimum location of the turbine required multiple experiments where turbine height varies between 35% and 95% (water height percentages above the diffuser), while varying the airflow between 1.42 L/s (3 CFM) and 2.12 L/s (4.5 CFM) with a 0.24 L/s (0.5 CFM) increment. Additionally, three water heights of 38.1 cm (15*), 53.4 cm (21*), and 68.6 cm (27*) were considered to study the influence of the water height. It was noticed that the presence of the system has an adverse effect on the standard oxygen transfer efficiency (SOTE). Therefore, a small dual-blade propeller was installed right above the diffuser to directly mix the water in the bottom of the tank with the incoming air to enhance the SOTE. The results showed that the maximum reclaimed power was obtained where the hydro-turbine is installed at 65–80% above the diffuser. A reduction of up to 7.32% in SOTE was observed when the setup was placed inside the tank compared to the tank alone. The addition of the dual-blade propeller showed an increase in SOTE of 7.27% with a power loss of 6.21%, ensuring the aeration process was at its standards.

Energy & Fuels↗

Update on ASME AG-1 and Revision of the DOE Nuclear Air Cleaning Handbook - 20536

The American Society of Mechanical Engineers AG-1 Code on Nuclear Air and Gas Treatment is updated every two years. This paper provides an overview of issues being discussed within AG-1 committee meetings and revisions that will be included in the next version of the code. Additional information is provided on issues being discussed ranging from media velocity limits, control of airflow using actual versus and standard cubic feet per minute. Navigation and identification of applicable high-efficiency particulate air (HEPA) filter code sections can be confusing for those unfamiliar with AG-1. A general reorganization of filtration code sections clarifies geometry, flow, and performance envelopes for nuclear grade HEPA filters. The initial step consists of establishment of Section FN covering qualification of conventional, ceramic, metal, and high strength fibrous glass media. Future filter sections are currently expected to be characterized by geometry and flow direction (axial vs. radial). The Department of Energy's (DOE) Nuclear Air Cleaning Handbook (NACH) is also undergoing revision. An update on the status of that effort, along with issues and changes being considered. The original charter of the AG-1 Code was specific to commercial nuclear power plants, and to safety-related air cleaning systems. This has evolved over the years to include normal non-safety ventilation systems and process gas systems. Corollary guidance for DOE facilities has been available in several editions of the Nuclear Air Cleaning Handbook, starting with ORNL-NSIC 65. The latest edition of the Handbook, 2003, is undergoing revision and modifications. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Efficient bi-directional coupling of 3D computational fluid-particle dynamics and 1D Multiple Path Particle Dosimetry lung models for multiscale modeling of aerosol dosimetry

The development of predictive aerosol dosimetry models has been a major focus of environmental toxicology and pharmaceutical health research for decades. One-dimensional (1D) models successfully predict overall deposition averages but fail to accurately predict local deposition. Computational fluid-particle dynamics (CFPD) models provide site-specific predictions but at a computational cost that prohibits whole lung predictions. Thus, there is a need for developing multiscale strategies to provide a realistic subject-specific picture of the fate of inhaled aerosol in the lungs. CT-based 3D/CFPD models of the large airways were bidirectionally coupled with individualized 1D Navier-Stokes airflow and particle transport based upon the widely used Multiple Path Particle Dosimetry Model (MPPD). Distribution of airflows among lobes was adjusted by measured lobar volume changes observed in CT images between FRC and FRC + 1.5 L. Additionally, as a test of the effectiveness of the coupling procedures, deposition modeling of previous 1 µm aerosol exposure studies was performed. The complete coupled model was run for 3 breaths, with the computation-intense portion being the 3D CFD Lagrangian particle tracking calculation. The average deposition per breath was 11% in the combined multiscale model with site-specific doses available in the CFPD portion of the model and airway- or region-specific deposition available for the MPPD portion. In conclusion, the key methods developed in this study enable predictions of ventilation heterogeneities and aerosol deposition across the lungs that are not captured by 3D or 1D models alone. Overall, these methods can be used as the foundation for multi-scale modeling of the full respiratory system.

60 APPLIED LIFE SCIENCES↗

Filtration Performance Results: Sierra Peaks Material No. 4

Sandia National Laboratories (SNL) assessed the filtration performance of materials from Sierra Peaks to identify alternatives which may perform similarly to materials used in FDA-approved N95 respirators. This work is meant to characterize the aerosol performance of materials to give Sierra Peaks information for them to determine if they elect to submit masks made using these materials for follow-on N95 certification testing at an accredited facility. The R&D testbed used is a large-scale filtration system designed to test commercial filter boxes. System modifications were performed to simulate, where possible, parameters defined by the National Institute for Occupational Safety and Health (NIOSH) for certification of filter materials for N95 respirators (NIOSH 2019). The system is a pull-through design. Air enters through a Laminar Flow Element (LFE) and the volumetric flow is measured based on the pressure drop across the LFE. Pressure is measured via a Pressure Transducer (PT). The air then passes through a High Efficiency Particulate Air (HEPA) filter to purge the air of ambient airborne particulates. Test aerosol is injected into the flow shortly after and mixing is induced via a coarse mesh. The airflow is allowed to fully develop prior to arriving at the test section. The aerosol then passes through the test material mounted in a box in the test section. Pressure drop across the test article is measured and aerosol sampling probes measure the aerosol concentrations upstream and downstream of the sample. The air passes through a second HEPA filter prior to being exhausted to ambient by a blower. A Topas aerosol generator is used to produce the test aerosol from Sodium Chloride (NaC1) dissolved in deionized (DI) water. Generated aerosol passes through a heated mixing chamber and a desiccant dryer to produce nanosized solid-state particulates. A dilution loop allows for the aerosol concentration to be regulated. The aerosol sampling probes upstream and downstream of the test section are aligned with the flow path. These are ducted directly to the aerosol sizing and counting instruments. A Laser Aerosol Spectrometer (LAS) was used for data collection in the original configuration of the system and was also used for initial testing in this project. Because the lower measurement range for the LAS is 90 nanometers (nm), the LAS was switched out for a more complicated Scanning Mobility Particle Sizer (SMPS) spectrometer system. The SMPS is comprised of an Electrostatic Classifier (EC), Differential Mobility Analyzer (DMA), and a Condensation Particle Counter (CPC). This enabled data collection at 75 nm, the particle size called out in the NIOSH guidelines.

36 MATERIALS SCIENCE↗

Measuring Local Turbulence Along the Optical Path: Multi-Beam Optical Seeing Sensor

Deflection of light along the optical path is a major source of image degradation for ground-based telescopes. Methods have been developed to measure upper atmospheric seeing based on models of the turbulence in the atmosphere, but due to boundary conditions, transmission within telescope enclosures is more complex. The Multi-beam Optical Seeing Sensor (MOSS) directly measures the component of the image quality degradation from inhomogeneity of the index of refraction within the telescope dome. MOSS outputs four near-parallel beams of light that travel along the optical path and are imaged by the telescope’s detector, landing like starlight on the telescope’s focal plane. By using a strobed light source, we can ‘freeze’ the instantaneous index variations transverse to the optical path. This system captures both ‘dome’ and ‘mirror’ seeing. Through plotting the standard deviation of differential motion between pairs of beams, MOSS enables characterization of the length scale of turbulence within the dome. The temporal coherence of temperature gradients can be probed with different pulse lengths, and the spatial coherence by comparing pairs at different separations across the aperture of the telescope. Optical path turbulence measurements, alongside other telemetry metrics, will guide thermal and airflow management to optimize image quality. A MOSS prototype was installed in the 1.2[Formula: see text]m Auxiliary Telescope (AuxTel) at the Vera C. Rubin Observatory in Chile, and preliminary data constrain the optical path turbulence with a lower bound of 1.4 arcsec. The optical path turbulence varied throughout the night of observing.

Astronomical seeing↗

Coupling Mesoscale Budget Components to Large-Eddy Simulations for Wind-Energy Applications

To simulate the airflow through a wind farm across a wide range of atmospheric conditions, microscale models (e.g., large-eddy simulation, LES, models) have to be coupled with mesoscale models, because microscale models lack the atmospheric physical processes to represent time-varying local forcing. Here we couple mesoscale model outputs to a LES solver by applying mesoscale momentum- and temperature-budget components from the Weather Research and Forecasting model to the governing equations of the Simulator fOr Wind Farm Applications model. We test whether averaging the budget components affects the LES results with regard to quantities of interest to wind energy. Our study focuses on flat terrain during a quiescent diurnal cycle. The simulation results are compared with observations from a 200-m tall meteorological tower and a wind-profiling radar, by analyzing time series, profiles, rotor-averaged quantities, and spectra. However, while results show that averaging reduces the spatio-temporal variability of the mesoscale momentum-budget components, when coupled with the LES model, the mesoscale bias (in comparison with observations of wind speed and direction, and potential temperature) is not reduced. In contrast, the LES technique can correct for shear and veer. In both cases, however, averaging the budget components shows no significant impact on the mean flow quantities in the microscale and is not necessary when coupling mesocale budget components to the LES model.

17 WIND ENERGY↗

Towards replacing physical testing of granular materials with a Topology-based Model

In the study of packed granular materials, the performance of a sample (e.g., the detonation of a high-energy explosive) often correlates to measurements of a fluid flowing through it. The “effective surface area,” the surface area accessible to the airflow, is typically measured using a permeametry apparatus that relates the flow conductance to the permeable surface area via the Carman-Kozeny equation. This equation allows calculating the flow rate of a fluid flowing through the granules packed in the sample for a given pressure drop. However, Carman-Kozeny makes inherent assumptions about tunnel shapes and flow paths that may not accurately hold in situations where the particles possess a wide distribution in shapes, sizes, and aspect ratios, as is true with many powdered systems of technological and commercial interest. To address this challenge, we replicate these measurements virtually on micro-CT images of the powdered material, introducing a new Pore Network Model based on the skeleton of the Morse-Smale complex. Pores are identified as basins of the complex, their incidence encodes adjacency, and the conductivity of the capillary between them is computed from the cross-section at their interface. We build and solve a resistive network to compute an approximate laminar fluid flow through the pore structure. Here, we provide two means of estimating flow-permeable surface area: (i) by direct computation of conductivity, and (ii) by identifying dead-ends in the flow coupled with isosurface extraction and the application of the Carman-Kozeny equation, with the aim of establishing consistency over a range of particle shapes, sizes, porosity levels, and void distribution patterns.

36 MATERIALS SCIENCE↗

Numerical Investigation of Enhanced Dehumidification Processes By Using Dielectrophoresis Principles in Moist Airflows

Dispersed particle-laden flows are encountered in many building and industrial applications, such as flow in a fluidized bed, hydrocarbon transportation in pipelines, and the fouling of air-cooled heat exchangers (Kuruneru et al., 2016; Ray et al., 2019; Wang et al., 2019). Computational fluid dynamic (CFD) models have been developed in recent years to depict particle-fluid and particle-particle interactions in laminar or turbulent flows with increasing accuracy and stability. One particular particle-laden system of interest for moisture control is electrically-enhanced condensation in air and water droplet flows. Electrically-enhanced condensation consists of the use of highly charged water droplets injected in the moist air. The droplets become electric seeds that attract polar water vapor molecules to their surfaces and promote condensation. The nucleation and growth of the charged droplets deplete the vapor phase near a droplet, which is compensated for by the dielectrophoresis flow and diffusion. Dielectrophoresis flow involves surrounding vapor at a distance of about 10 to 100 nm for droplets charged by an electrospray compared to ~2 nm for a single electron charge in a droplet. As the vapor molecules collapse on the surface of the droplets, their initial electrical charge decreases with time due to the neutralization of the ions. While the physics of this phenomena is well known, engineering models for predicting the condensation rates are not available. This work computationally investigates dehumidification of moist airflow in a converging rectangular duct. The objective is to develop an engineering model that predicts water vapor condensation by employing dielectrophoresis principles. We construct a Computational Fluid Dynamics (CFD) model of the duct with electrically-enhanced condensation. The model is implemented in the open-source software OpenFOAM. We utilize the Multi-Phase Particle-In-Cell (MP-PIC) method coupled with a Population Balance Equation (PBE) approach to simulate the particle-laden system. This methodology is an Eulerian-Lagrangian approach used to simulate the droplets' behavior in the humid air. The MP-PIC approach (Andrews and O'Rourke, 1996) mitigates the computational cost by parceling several fundamental particles with similar properties (such as types, sizes, and temperature) into one computational particle. Thus, the billions of particles can be substituted by millions of computational particles without significant loss of information. The PBE was considered with the Lagrangian frame to combine the particle distribution function used in MP-PIC (Kim et al., 2020). This approach preserves mass and energy conservation between the phases in the Eulerian and Lagrangian structures. The PBE in this procedure was directly linked to the discrete parcels, making the simulation of the particle distribution computationally efficient and robust. The MP-PIC-PBE approach used in the present work was applied to the dehumidification of air. Water droplets were injected in the air stream and forced to grow according to experimentally derived correlation. The experiments were conducted on a converging duct with the same geometry and boundary conditions used to build the CFD model. This approach enabled us to approximate the effect of dielectrophoresis phenomena on the droplet and air interface. This presentation will discuss the details of the new CFD model built for the duct, the implementation of the model in OpenFOAM CFD programming language, and the experimental validation of the newly developed model. The results revealed a moderate yet measurable increase in droplet diameter due to water vapor condensation at the vapor-liquid interface of the electrically charged droplets' surface. The seed water droplet particles grew in size by capturing the water vapor in the surrounding air. The OpenFOAM model predicted reductions of humidity in the air from 5 to 10 percent.

Yel Mahi, Maliha↗