Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “directional airflow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Solar heating system at Quitman County Bank, Marks, Mississippi

Information on the Solar Energy Heating System installed in a single story wood frame, cedar exterior, sloped roof building is presented. The system has on-site temperature and power measurements readouts. The 468 square feet of Solaron air flat plate collectors provide for 2,000 square feet of space heating, an estimated 60 percent of the heating load. Solar heated air is distributed to the 235 cubic foot rock storage box or to the load (space heating) by a 960 cubic feet per minute air handler unit. A 7.5 ton Carrier air-to-air heat pump with 15 kilowatts of electric booster strips serve as a back-up (auxiliary) to the solar system. Motorized dampers control the direction of airflow and back draft dampers prevent thermal siphoning of conditioned air.

Source record↗

Riblets for Stars and Stripes

Stars and Stripes racing yacht brought the American's Cup back to the United States. Originating from NASA's drag reduction technology, the boats "secret weapon" was that the hull's underside was coated with riblets. Riblets are small, barely visible grooves on the surface of an airplane intended to reduce skin friction by smoothing the turbulent airflow next to the skin. Grooves are V-shaped with the angle pointing in the direction of the airflow. No deeper than a scratch, they have a pronounced beneficial influence on air turbulence. *No longer commercially available.

Source record↗

Experimental Verification of Material Flammability in Space

The flammability in microgravity of three US-furnished materials, Delrin, polymethylmethacrylate (PMMA), and high-density polyethylene, was determined using a Russian-developed combustion tunnel on Mir. Four 4.5-mm-diameter cylindrical samples of each plastic were ignited under concurrent airflow (in the direction of flame spread) with velocities from no flow to 8.5 cm/s. The test results identify a limiting air-flow velocity V(sub lim) for each material, below which combustion ceases. Nominal values are V(sub lim) < 0.3 cm/s for Delrin, 0.5 cm/s for PMMA, and 0.3 to 0.5 cm/s for polyethylene. These values are lower than those obtained in prior ground testing. Nevertheless, they demonstrate that flow shutoff is effective for extinguishment in the microgravity environment of spacecraft. Microgravity test results also show that the plastic materials maintain a stable melt ball within the spreading flame zone. In general, as the concurrent flow velocity V decreases, the flame-spread rate V(sub F) decreases, from an average (for all three materials) of V(sub F)= 0.5-0.75 mm/s at V = 8.5 cm/s to V(sub F)= 0.05-0.01 mm/s at V = 0.3-0.5 cm/s. Also, as V decreases, the flames become less visible but expand, increasing the probability of igniting an adjacent surface.

Ivanov, A. V.↗

Study of porous surface microphones for acoustic measurements in wind tunnels

Porous surface sensors acting as directional microphones in subsonic airflow were investigated. The first part of the report deals with the design of a porous strip sensor set in an aerofoil. The second part presents the experimental results of frequency response, directivity, and flow noise of a porous pipe sensor and a porous strip sensor. For flow noise, these sensors were compared with the Bruel and Kjaer half-inch condenser microphone with a nose cone. The flow noise was examined under two conditions of flow: in a very quiet flow where the turbulence was approximately 0.3% and in a spoiled flow where the turbulence was approximately 5%.

Noiseux, D. U.↗

Developing a Control Strategy for Minimum Airflow Setting Considering CO2 Level and Energy Consumption in a Variable Air Volume System

In an office building equipped with a Variable Air Volume (VAV) system, this paper introduces a novel method for controlling the minimum supply airflow fraction in each zone’s VAV box, having a capability to consider indoor CO2 level and energy consumption. The EnergyPlus simulation using the medium office prototype model was employed, which evaluated the performance of the energy and CO2 concentration for five VAV box airflow control strategies. The paper focuses on CO2 concentration-based airflow control method and compares it with other four methods including conventional single-max, reduced minimum single-max, demand-controlled ventilation(DCV), and dualmax control methods according to guidelines and common practices. The newly proposed control strategy directly correlates the minimum airflow fraction to CO2 concentration. A general trend emerged when comparing CO2 concentrations—lower minimum airflow fractions were associated with higher concentrations. The proposed control method effectively maintained low CO2 concentrations and enabled a lower airflow fraction contributing to energy consumption reduction. It was confirmed that heating energy consumption in climate zone 4A, 5B, and 6A showed a maximum saving of approximately 30% compared to the conventional single-max and dual max control strategies. It was found that cooling energy consumption in climate zone 4A and 6A can achieve a maximum saving of approximately 10% compared to the conventional control strategies. The proposed CO2 concentration-based control logic is promising as it not only improves the indoor air quality lowering the CO2 concentration in the occupied spaces, but also contributes to HVAC energy savings.

Lee, Jong Man↗

Effect of Liner Cooling Flow on Combustor Emissions for Commercial Supersonics Technology

An overview is provided of a parametric study conducted to study the effect of liner cooling airflow rates on NOx emissions of a seven-element lean-direct injection (LDI) module with radial airflow main swirlers. The goal of the CFD study was to determine the increase in cooling flow rate at which the NOx emissions would exceed 20% of the predicted emissions with zero liner cooling flow. The Open version of the National Combustion Code (OpenNCC) was used to perform two-phase reacting flow computations with a new LDI injection module design with radial airflow swirlers instead of axial airflow swirlers. CFD analysis with OpenNCC predicted a 20% increase in EINOx emissions was reached when the liner cooling airflow rate was increased to 15% of the baseline combustor airflow rate. The liner cooling flow rate was predicted to have a non-linear effect on increase in overall EINOx of the seven element LDI injection module.

CFD↗

Augmentation of Stagnation Region Heat Transfer Due to Turbulence from a DLN Can Combustor

Heat transfer measurements have been made in the stagnation region of a flat plate with a circular leading edge. Electrically heated aluminum strips placed symmetrically about the leading edge stagnation region were used to measure spanwise-averaged heat transfer coefficients. The maximum Reynolds number obtained, based on leading edge diameter, was about 100,000. The model was immersed in the flow field downstream of an approximately half-scale model of a can-type combustor from a low NO(x), ground-based power-generating turbine. The tests were conducted with room temperature air; no fuel was added. Room air flowed into the combustor through six vane-type fuel/air swirlers. The combustor can contained no dilution holes. The fuel/air swirlers all swirled the incoming airflow in a counterclockwise direction (facing downstream). A five-hole probe flow field survey in the plane of the model stagnation point showed the flow was one big vortex with flow angles up to 36 deg at the outer edges of the rectangular test section. Hot-wire measurements showed test section flow had very high levels of turbulence, around 28.5%, and had a relatively large axial-length scale-to-leading edge diameter ratio of 0.5. X-wire measurements showed the turbulence to be nearly isotropic. Stagnation heat transfer augmentation over laminar levels was around 77% and was about 14% higher than predicted by a previously developed correlation for isotropic grid-generated turbulence.

VanFossen, G. James↗

Effect of Liner Cooling Flow on Combustor Emissions for Commercial Supersonics Technology

An overview is provided of a parametric study conducted to study the effect of liner cooling airflow rates on NOx emissions of a seven-element lean-direct injection (LDI) module with radial airflow main swirlers. The goal of the CFD study was to determine the increase in cooling flow rate at which the NOx emissions would exceed 20% of the predicted emissions with zero liner cooling flow. The Open version of the National Combustion Code (OpenNCC) was used to perform two-phase reacting flow computations with a new LDI injection module design with radial airflow swirlers instead of axial airflow swirlers. CFD analysis with OpenNCC predicted a 20% increase in EINOx emissions was reached when the liner cooling airflow rate was increased to 15% of the baseline combustor airflow rate. The liner cooling flow rate was predicted to have a non-linear effect on increase in overall EINOx of the seven element LDI injection module.

CFD↗

Recent Studies on Methanol Crossover in Liquid-Feed Direct Methanol Fuel Cells

In this work, the effects of methanol crossover and airflow rates on the cathode potential of an operating direct methanol fuel cell are explored. Techniques for quantifying methanol crossover in a fuel cell and for separating the electrical performance of each electrode in a fuel cell are discussed. The effect of methanol concentration on cathode potential has been determined to be significant. The cathode is found to be mass transfer limited when operating on low flow rate air and high concentrations of methanol. Improvements in cathode structure and operation at low methanol concentration have been shown to result in improved cell performance.

Valdez, T. I.↗

Noise measurement in wind tunnels, workshop summary

In reviewing the progress made in acoustic measurements in wind tunnels over the 5-yr span of the workshops, it is evident that a great deal of progress has occurred. Specialized facilities are now on line, special measurement techniques were developed, and corrections were devised and proven. This capability is in the process of creating a new and more correct data bank on acoustic phenomena, and represents a major step forward in acoustics technology. Additional work is still required, but now, rather than concentrating on facilities and techniques, researchers may more profitably concentrate on noise-source modeling, with the simulation of propulsor noise source (in flight) and of propulsor/airframe airflow characteristics. Promising developments in directional acoustic receivers and other discrimination/correlation techniques should now be regularly exploited, in part for model noise-source diagnosis, but also to expedite extraction of the lone source signal from any residual background noise and reverberation in the working chamber and from parasitic noise due to essential rigs or instrumentation inside the airstream.

Hickley, D. H.↗

Hot-Gas Nozzle for Desoldering Leadless IC's

Simple hand-held tool removes leadless, surface-mounted integrated circuits (IC's) from printed-circuit boards. Nozzle used with hot-air gun of type used to apply heat-shrink tubing or with some other source of hot gas. Rectangular end of nozzle and deflector shape airflow pattern to concentrate heat directly on soldering pads located around edge of IC's to heat them quickly and uniformly.

Hanlon, Mark T.↗

Augmentation of Stagnation Region Heat Transfer Due to Turbulence From a DLN Can Combustor

Heat transfer measurements have been made in the stagnation region of a flat plate with a circular leading edge. Electrically heated aluminum strips placed symmetrically about the leading edge stagnation region were used to measure spanwise averaged heat transfer coefficients. The maximum Reynolds number obtained, based on leading edge diameter, was about 100,000. The model was immersed in the flow field downstream of an approximately half scale model of a can-type combustor from a low NO(x), ground based power-generating turbine. The tests were conducted with room temperature air; no fuel was added. Room air flowed into the combustor through six vane type fuel/air swirlers. The combustor can contained no dilution holes. The fuel/air swirlers all swirled the incoming airflow in a counter clockwise direction (facing downstream). A 5-hole probe flow field survey in the plane of the model stagnation point showed the flow was one big vortex with flow angles up to 36' at the outer edges of the rectangular test section. Hot wire measurements showed test section flow had very high levels of turbulence, around 28.5 percent, and had a relatively large axial-length scale-to-leading edge diameter ratio of 0.5. X-wire measurements showed the turbulence to be nearly isotropic. Stagnation heat transfer augmentation over laminar levels was around 77 percent and was about 14 percent higher than predicted by a previously developed correlation for isotropic grid generated turbulence.

VanFossen, G. James↗

Technology development activities for housing research animals on Space Station Freedom

The development and design of animal facilities are described in terms of the technological needs for NASA's Biological Flight Research Laboratory. Animal habitats are presented with illustrations which encompass waste-collection techniques for microgravity conditions that reduce the need for crew participation. The technology is intended to be highly compatible with animal morphology, and airflow is employed as the primary mechanism of waste control. The airflow can be utilized in the form of localized high-speed directed flow that simultaneously provides a clean animal habitat and low airflow rates. The design of an animal-habitat testbed is presented which capitalizes on contamination-control mechanisms and suitable materials for microgravity conditions. The developments in materials and technologies represent significant contributions for the design of the centrifuge facilities for the Space Station Freedom.

Jenner, Jeffrey W.↗

Results from cascade thrust reverser noise and suppression experiments

Results from experimental work on model scale cascade reversers with cold airflow are presented. Sound power level directivity and spectral characteristics for cascade reversers are reported. Effect of cascade exit area ratio, vane profile shape, and emission arc are discussed. Model equivalent diameters varied from 3 to 5 inches, pressure ratios range from 1.15 to 3.0. Depending on the reverser type, acoustic power was proportional to the 4 1/2 to 6th power of ideal jet velocity. Reverser noise peaked at higher frequency and was more omnidirectional than nozzle-alone jet noise. Appreciable reduction in sideline noise was obtained from plane shields. Airfoil-vaned cascades were the most aerodynamically efficient and least noisy reversers. Scaling of cascade reverser data to example aircraft engines showed all cascades above the 95 PNdB sideline goal from STOL aircraft. However, the airfoil-vaned reverser has a good potential for meeting this goal for high-bypass (low pressure ratio) exhausts.

Gutierrez, O. A.↗