An Integrated Imaging Detector of Polarization and Spectral Content

A new type of image detector has been designed to simultaneously analyze the polarization of light at all picture elements in a scene. The Integrated Dual Imaging Detector (IDID) consists of a polarizing beamsplitter bonded to a charge-coupled device (CCD), with signal-analysis circuitry and analog-to-digital converters, all integrated on a silicon chip. It should be capable of 1:10(exp 4) polarization discrimination. The IDID should simplify the design and operation of imaging polarimeters and spectroscopic imagers used, for example, in atmospheric and solar research. Innovations in the IDID include (1) two interleaved 512 x 1024-pixel imaging arrays (one for each polarization plane); (2) large dynamic range (well depth of 10(exp 6) electrons per pixel); (3) simultaneous readout of both images at 10 million pixels per second each; (4) on-chip analog signal processing to produce polarization maps in real time; (5) on-chip 10-bit A/D conversion. When used with a lithium-niobate Fabry-Perot etalon or other color filter that can encode spectral information as polarization, the IDID can collect and analyze simultaneous images at two wavelengths. Precise photometric analysis of molecular or atomic concentrations in the atmosphere is one suggested application. When used in a solar telescope, the IDID will charge the polarization, which can then be converted to maps of the vector magnetic fields on the solar surface.

Rust, D. M.↗

Target-Tracking Camera for a Metrology System

An analog electronic camera that is part of a metrology system measures the varying direction to a light-emitting diode that serves as a bright point target. In the original application for which the camera was developed, the metrological system is used to determine the varying relative positions of radiating elements of an airborne synthetic aperture-radar (SAR) antenna as the airplane flexes during flight; precise knowledge of the relative positions as a function of time is needed for processing SAR readings. It has been common metrology system practice to measure the varying direction to a bright target by use of an electronic camera of the charge-coupled-device or active-pixel-sensor type. A major disadvantage of this practice arises from the necessity of reading out and digitizing the outputs from a large number of pixels and processing the resulting digital values in a computer to determine the centroid of a target: Because of the time taken by the readout, digitization, and computation, the update rate is limited to tens of hertz. In contrast, the analog nature of the present camera makes it possible to achieve an update rate of hundreds of hertz, and no computer is needed to determine the centroid. The camera is based on a position-sensitive detector (PSD), which is a rectangular photodiode with output contacts at opposite ends. PSDs are usually used in triangulation for measuring small distances. PSDs are manufactured in both one- and two-dimensional versions. Because it is very difficult to calibrate two-dimensional PSDs accurately, the focal-plane sensors used in this camera are two orthogonally mounted one-dimensional PSDs.

Liebe, Carl↗

Delay Line Detectors for the UVCS and Sumer Instruments on the SOHO Satellite

Microchannel plate based detectors with cross delay line image readout have been rapidly implemented for the SUMER and UVCS instruments aboard the Solar Orbiting Heliospheric Observatory (SOHO) mission to be launched in July 1995. In October 1993 a fast track program to build and characterize detectors and detector control electronics was initiated. We present the detector system design for the SOHO UVCS and SUMER detector programs, and results from the detector test program. Two deliverable detectors have been built at this point, a demonstration model for UVCS, and the flight Ly alpha detector for UVCS, both of which are to be delivered in the next few weeks. Test results have also been obtained with one other demonstration detector system. The detector format is 26mm x 9mm, with 1024 x 360 digitized pixels, using a low resistance Z stack of microchannel plates (MCP's) and a multilayer cross delay line anode (XDL). This configuration provides gains of approximately 2 x 10(exp 7) with good pulse height distributions (less than 50% FWHM) under uniform flood illumination, and background levels typical for this configuration (approximately 0.6 event cm (exp -2)sec(exp -1)). Local counting rates up to about 400 events/pixel/sec have been achieved with no degradation of the MCP gain. The detector and event encoding electronics achieves about 25 millimeter FVHM with good linearity (plus or minus approximately 1 pixel) and is stable to high global counting rates (greater than 4 x 10(exp 5) events sec(exp -1)). Flat field images are dominated by MCP fixed pattern noise and are stable, but the MCP multifiber modulation usually expected is uncharacteristically absent. The detector and electronics have also successfully passed both thermal vacuum and vibration tests.

Seigmund, O. H. W.↗

Science Enabling ASICs and FEEs for the JUICE and JEO Missions

A family of science enabling radiation hard Application Specific Integrated Circuits (ASICs), Front End Electronics (FEEs) and Event Processing Systems, with flight heritage on many NASA missions, is presented. These technologies play an important role in the miniaturization of instruments -and spacecraft systems- at the same time increasing performance and reducing power. The technologies target time of flight, position sensing, and energy measurements as well as standard housekeeping and telemetry functions for particle and fields instruments, but find applications in other instrument categories too. More specifically the technologies include: the TOF chip, 1D and 2D Delay Lines with MCP detectors, for high precision fast and low power time of flight and position sensing; the Energy chip for multichannel SSD readout with time over threshold and standard voltage read out for TDC and ADC digitization; Fast multi channel read out chip with commandable thresholds; the TRIO chip for multiplexed ADC and housekeeping etc. It should be mentioned that the ASICs include basic trigger capabilities to enable random event processing in a heavy background of penetrators and UV foreground. Typical instruments include time of flight versus energy and look angle particle analyzers such as: plasma composition, energetic particle, neutral atom imaging as well as fast plasma and deltaE/E ion/electron telescopes. Flight missions include: Cassini/LEMMS, IMAGE/HENA, MESSENGER/EPPS/MLA/X-ray/MLA, STEREO, PLUTO-NH/PEPSSI/LORI, IBEX-Lo, JUNO/JEDI, RBSP/RBSPICE, MMS/HPCA/EPD, SO/SIS. Given the proven capability on heavy radiation missions such as JUNO, MMS and RBSB, as well diverse long duration missions such as MESSENGER, PLUTO and Cassini, it is expected that these technologies will play an important role in the particle and fields (at least) instruments on the upcoming JUICE and JEO missions.

Paschalidis, Nicholas↗

Development of a high-resolution automatic digital (urine/electrolytes) flow volume and rate measurement system of miniature size

To aid in the quantitative analysis of man's physiological rhythms, a flowmeter to measure circadian patterns of electrolyte excretion during various environmental stresses was developed. One initial flowmeter was designed and fabricated, the sensor of which is the approximate size of a wristwatch. The detector section includes a special type of dielectric integrating type sensor which automatically controls, activates, and deactivates the flow sensor data output by determining the presence or absence of fluid flow in the system, including operation under zero-G conditions. The detector also provides qualitative data on the composition of the fluid. A compact electronic system was developed to indicate flow rate as well as total volume per release or the cumulative volume of several releases in digital/analog forms suitable for readout or telemetry. A suitable data readout instrument is also provided. Calibration and statistical analyses of the performance functions required of the flowmeter were also conducted.

Liu, F. F.↗

Development of Thermal Infrared Sensor to Supplement Operational Land Imager

The thermal infrared sensor (TIRS) is a quantum well infrared photodetector (QWIP)-based instrument intended to supplement the Operational Land Imager (OLI) for the Landsat Data Continuity Mission (LDCM). The TIRS instrument is a far-infrared imager operating in the pushbroom mode with two IR channels: 10.8 and 12 m. The focal plane will contain three 640 ~512 QWIP arrays mounted onto a silicon substrate. The readout integrated circuit (ROIC) addresses each pixel on the QWIP arrays and reads out the pixel value (signal). The ROIC is controlled by the focal plane electronics (FPE) by means of clock signals and bias voltage value. The means of how the FPE is designed to control and interact with the TIRS focal plane assembly (FPA) is the basis for this work. The technology developed under the FPE is for the TIRS focal plane assembly (FPA). The FPE must interact with the FPA to command and control the FPA, extract analog signals from the FPA, and then convert the analog signals to digital format and send them via a serial link (USB) to a computer. The FPE accomplishes the described functions by converting electrical power from generic power supplies to the required bias power that is needed by the FPA. The FPE also generates digital clocking signals and shifts the typical transistor-to-transistor logic (TTL) to }5 V required by the FPA. The FPE also uses an application- specific integrated circuit (ASIC) named System Image, Digitizing, Enhancing, Controlling, And Retrieving (SIDECAR) from Teledyne Corp. to generate the clocking patterns commanded by the user. The uniqueness of the FPE for TIRS lies in that the TIRS FPA has three QWIP detector arrays, and all three detector arrays must be in synchronization while in operation. This is to avoid data skewing while observing Earth flying in space. The observing scenario may be customized by uploading new control software to the SIDECAR.

Shu, Peter↗