Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “difference frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Mid-infrared trace gas detection using continuous-wave difference frequency generation in periodically poled RbTiOAsO4

A tunable mid-infrared continuous-wave (cw) spectroscopic source in the 3.4-4.5 micrometers region is reported, based on difference frequency generation (DFG) in a quasi-phase-matched periodically poled RbTiOAsO4 (PPRTA) crystal. DFG power levels of 10 microW were generated at approximately 4 micrometers in a 20-mm long PPRTA crystal by mixing two cw single-frequency Ti:Al2O3 lasers operating near 713 nm and 871 nm, respectively, using a laser pump power of 300 mW. A quasi-phase-matched infrared wavelength-tuning bandwidth (FWHM) of ~ 12 cm-1 and a temperature tuning rate of 1.02 cm-1/degree C were achieved. Experimental details regarding the feasibility of trace gas detection based on absorption spectroscopy of CO2 in ambient air using this DFG radiation source are also described.

NASA Discipline Life Sciences Technologies↗

Mid-infrared difference-frequency generation source pumped by 1.1-1.5 micrometer dual-wavelength fiber amplifier for trace-gas detection

Continuous-wave mid-infrared radiation near 3.5 micrometers is generated by difference-frequency mixing of the output of a compact 1.1-1.5 micrometer dual-wavelength fiber amplifier in periodically poled LiNbO3. The diode side-pumped amplifier is constructed with double-cladding Yb-doped fiber followed by single-mode Er/Yb codoped fiber. Output powers of as much as 11 microW at 3.4 micrometers are obtained, and spectroscopic detection of CH4 and H2CO is demonstrated. c 1998 Optical Society of America.

Non-NASA Center↗

New features of different frequency generating systems due to the use of electrodeless rigidly mounted VBA quartz crystal resonator

The BVA 5 MHz crystal equipped frequency sources exhibit a new blend of performances such as 10 to 11 daily stability, 5x10-13 short term stability (1 to 30 s time intervals) and close to the carrier low phase noise (1 Hz : -120 dBc, 10 Hz : -140 dBc), whereby retaining the customary crystal oscillator benefits of small volume, high reliability and low price, as opposed to more sophisticated frequency generators which would be required to achieve comparable performances. Examples illustrating the impact of the Oscilloquartz BVA oven-controlled crystal oscillator in different frequency generating systems are presented: cesium frequency standards; hydrogen frequency standard; a precision distribution sub-system for satellite ground stations; and high hierarchy exchanges of digital networks, synchronized by the master-slave method are discussed.

Jendly, A.↗

High-power continuous-wave mid-infrared radiation generated by difference frequency mixing of diode-laser-seeded fiber amplifiers and its application to dual-beam spectroscopy

We report the generation of up to 0.7 mW of narrow-linewidth (<60-MHz) radiation at 3.3 micrometers by difference frequency mixing of a Nd:YAG-seeded 1.6-W Yb fiber amplifier and a 1.5-micrometers diode-laser-seeded 0.6-W Er/Yb fiber amplifier in periodically poled LiNbO3. A conversion efficiency of 0.09%/W (0.47 mWW-2 cm-1) was achieved. A room-air CH4 spectrum acquired with a compact 80-m multipass cell and a dual-beam spectroscopic configuration indicates an absorption sensitivity of +/-2.8 x 10(-5) (+/-1 sigma), corresponding to a sub-parts-in-10(9) (ppb) CH4 sensitivity (0.8 ppb).

Non-NASA Center↗

Construction and Calibration of a Difference Frequency Laser Spectrometer and New THZ Frequency Measurements of water and Ammonia

A three laser system based on 852nm DBR lasers has been constructed and used to generate radiation in the 750 GHz to 1600 GHz frequency region. The system works by locking two of the three lasers to modes of an ultra low expansion Fabry-Perot cavity. The third laser is offset locked to one of the cavity locked lasers with conventional microwave techniques. The signal from the offset laser and the other cavity locked laser are injected into a Master Oscillator Power Amplifier (MOPA), amplified and focused on a low temperature grown GaAs photomixer, which radiates the difference frequency. The system has been calibrated with molecular lines to better than one part in 10(exp 7). In this paper we present the application of this system to the v(sub 2) in inversion band of Ammonia and the ground and v(sub 2) states of water. A discussion of the system design, the calibration and the new spectral measurements will be presented.

Pearson, J. C.↗

The human oculomotor response to simultaneous visual and physical movements at two different frequencies

In order to investigate interactions in the visual and vestibular systems' oculomotor response to linear movement, we developed a two-frequency stimulation technique. Thirteen subjects lay on their backs and were oscillated sinusoidally along their z-axes at between 0.31 and 0.81 Hz. During the oscillation subjects viewed a large, high-contrast, visual pattern oscillating in the same direction as the physical motion but at a different, non-harmonically related frequency. The evoked eye movements were measured by video-oculography and spectrally analysed. We found significant signal level at the sum and difference frequencies as well as at other frequencies not present in either stimulus. The emergence of new frequencies indicates non-linear processing consistent with an agreement-detector system that have previously proposed.

NASA Discipline Neuroscience↗

Remote quantum state transfer for qubits with different frequencies

A quantum communication system includes a first quantum transceiver, a second quantum transceiver, and a quantum communication mediator (QCM) system. The transceivers have different resonant frequencies or physical systems. The QCM system receives an initial quantum signal from the first quantum transceiver. The QCM system transfers a quantum state of the initial quantum signal to a first mechanical signal and then from the first mechanical signal to a first pair of optical signals by way of a first three-wave mixing process. The QCM transfers the quantum state to a second pair of optical signals from the first pair by way of a four-wave mixing process. The QCM transfers the quantum state from the second pair of optical signals to a second mechanical signal by way of a second three-wave mixing process. The QCM transfers the quantum state from the second mechanical signal to a final quantum signal by mechanical transduction.

Soh, Daniel Beom Soo↗

Linear and Nonlinear X-ray Spectra of Chiral Molecules: X-ray Circular Dichroism, Sum- and Difference-Frequency Generation of Fenchone and Cysteine

Recent advancements in X-ray light sources enable element-sensitive nonlinear spectroscopies for probing molecular chirality. We simulate X-ray absorption spectroscopy, X-ray circular dichroism (XCD), and nonlinear optical/X-ray SFG and DFG (OX SFG/DFG) signals for two prototypical chiral molecules, fenchone and cysteine. Furthermore, our multireference simulations reproduce experimental data and reveal how novel X-ray spectroscopies exploit the site- and element-sensitivity of X-rays to uncover molecular asymmetry. The XCD spectra show strong asymmetries at chiral centers, while distant atoms contribute weaker signals. The OX SFG/DFG signals, under fixed resonant optical excitation, strongly depend on the core and valence excitations. This allows us to introduce two-dimensional (2D) chirality-sensitive valence-core spectroscopy, which provides insight into the overlap between valence orbitals and local molecular asymmetry. Finally, our estimates using realistic laser and X-ray pulse parameters demonstrate that such nonlinear experiments are feasible at XFELs, offering a promising tool for investigating chiral molecules.

Circular dichroism spectroscopy↗

Instantaneous difference frequency locking observed during toroidicity-induced Alfvén eigenmode coupling in the DIII-D tokamak

In magnetic confinement fusion, toroidicity-induced Alfvén eigenmodes (TAEs) are well-studied, weakly stable solutions of the linearized ideal magnetohydrodynamic equations. Driven unstable by suprathermal populations of energetic particles, TAE pose a key vulnerability to the confinement of high-energy alpha particles generated by fusion reactions. Hence, it is paramount to understand TAE dynamics if a working reactor is to be realized. In this work, we detect and characterize signatures of nonstationary nonlinear coupling between TAE using a novel, time-resolved bispectral analysis; results are supported by analytic signal of band-passed data. Crucially, a stationary phase relationship between two TAE and a nascent low frequency fluctuation is observed precisely when the triple product of magnetic fluctuation amplitudes is enhanced. Local mode number and frequency spectrum, gleaned from beam-emission spectroscopy, corroborates simultaneous satisfaction of nonlinear matching conditions, and provides a tool to identify theorized pathways of energy transfer, e.g. TAE parametric instability.

bispectral analysis↗

Difference-frequency-based tunable absorption spectrometer for detection of atmospheric formaldehyde

High-sensitivity detection of formaldehyde (CH2O) at 3.5315 micrometers (2831.64 cm-1) is reported with a diode-laser-pumped, fiber-coupled, periodically poled LiNbO3 spectroscopic source. This source replaced the Pb-salt diode laser Dewar assembly of an existing tunable diode-laser absorption spectrometer designed for ultrasensitive detection of CH2O. Spectra are recorded with 2f-modulation spectroscopy and zero-air rapid background subtraction. Initial measurements reported here, determined from multiple measurements of a flowing 7.7 parts per billion by volume (ppbv, parts in 10(9)) CH2O in air mixture, indicate replicate precisions as low as 0.24 ppbv.

Non-NASA Center↗

Experimental Performance Evaluation of a High Speed Permanent Magnet Synchronous Motor and Drive for a Flywheel Application at Different Frequencies

This paper presents the results of an experimental performance characterization study of a high speed, permanent magnet motor/generator (M/G) and drive applied to a flywheel module. Unlike the conventional electric machine the flywheel M/G is not a separated unit; its stator and rotor are integrated into a flywheel assembly. The M/G rotor is mounted on a flywheel rotor, which is magnetically levitated and sealed within a vacuum chamber during the operation. Thus, it is not possible to test the M/G using direct load measurements with a dynamometer and torque transducer. Accordingly, a new in-situ testing method had to be developed. The paper describes a new flywheel M/G and drive performance evaluation technique, which allows the estimation of the losses, efficiency and power quality of the flywheel high speed permanent magnet M/G, while working in vacuum, over wide frequency and torque ranges. This method does not require any hardware modification nor any special addition to the test rig. This new measurement technique is useful for high-speed applications, when applying an external load is technically difficult.

Nagorny, Aleksandr S.↗

Measurement of a radial flow profile with eddy current flow meters and deep neural networks

Eddy current flow meters (ECFMs) measure flows of conductive fluids. Recent interest in ECFMs has increased due to applications in advanced nuclear reactors. ECFMs are well suited for such applications, as they can provide non-invasive measurements of flow in fluids that are often difficult to measure. Traditionally, ECFMs are operated using an alternating current at a single frequency, limiting ECFMs to measure average fluid velocities, blockages, or voids. Here, we expand the capabilities of ECFMs by measuring the fluid radial velocity profile of liquid mercury. To accomplish this, we made several ECFM sensitivity measurements at a range of frequencies. Different frequencies vary the electromagnetic skin depth of the device. By adjusting frequencies, we probed the fluid velocity at various radial locations and constructed a flow-velocity profile. The relationship between the ECFM measurements and velocity profile is nonlinear and requires solving an inverse problem. Using electromagnetic finite-element simulations to train a deep neural network (DNN), we created a model that provides a stable general relationship between the sensitivity measurements of an ECFM and the fluid velocity profile. Using ECFM measurements of liquid mercury, our DNN model calculates a flow profile that agrees well with computational fluid dynamics (CFD) simulations. This technique has potential to improve flow monitoring for optimization, safe operation of conductive fluid loops, and/or validating complex CFD models.

47 OTHER INSTRUMENTATION↗

Measuring coal deposits by radar

Front-surface, local-oscillator radar directly compares frequency of signals reflected from front and back surfaces of coal deposits. Thickness is measured directly as frequency difference. Transmitter is frequency modulated, so thickness is computed directly from frequency difference. Because front and back reflections are detected in combination rather than separately, masking of comparatively weak back signal is less problem. Also system is not sensitive to extraneous reflections from targets between transmitting antenna and coal surface.

Barr, T. A.↗

Radar scatterometry of sand dunes and lava flows

Four frequency like polarized scatterometer data over a sand dune field and a volcanic field were analyzed to understand the scattering characteristics of these two terrain types as a function of frequency and incidence angle. For the frequency range studied (400 MHz to 13.3 GHz) unvegetated sand dunes are specular reflectors that return an echo to the radar antenna particularly when the geometry is such that the dune slope is nearly perpendicular to the antenna. Vegetation on the dunes can cause significant backscatter. Lava flows are strong diffuse scatterers which have backscatter values similar to coniferous forest at certain frequencies. Different observation frequencies are required for different situations. The scatterometer data correlate well with radar images.

Blom, R.↗

Polarimetric Imaging using Two Photoelastic Modulators

A method of polarimetric imaging, now undergoing development, involves the use of two photoelastic modulators in series, driven at equal amplitude but at different frequencies. The net effect on a beam of light is to cause (1) the direction of its polarization to rotate at the average of two excitation frequencies and (2) the amplitude of its polarization to be modulated at the beat frequency (the difference between the two excitation frequencies). The resulting modulated optical light beam is made to pass through a polarizing filter and is detected at the beat frequency, which can be chosen to equal the frame rate of an electronic camera or the rate of sampling the outputs of photodetectors in an array. The method was conceived to satisfy a need to perform highly accurate polarimetric imaging, without cross-talk between polarization channels, at frame rates of the order of tens of hertz. The use of electro-optical modulators is necessitated by a need to obtain accuracy greater than that attainable by use of static polarizing filters over separate fixed detectors. For imaging, photoelastic modulators are preferable to such other electrio-optical modulators as Kerr cells and Pockels cells in that photoelastic modulators operate at lower voltages, have greater angular acceptances, and are easier to use. Prior to the conception of the present method, polarimetric imaging at frame rates of tens of hertz using photoelastic modulators was not possible because the resonance frequencies of photoelastic modulators usually lie in the range from about 20 to about 100 kHz.

Wang, Yu↗