RadSim: Detector Response
This package simulates the expected output gamma spectra from a gamma detector for given configuration.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This package simulates the expected output gamma spectra from a gamma detector for given configuration.
A new GEANT4 model for DANCE with NEUANCE has been developed to account for the change in the DANCE configuration when NEUANCE is installed. In this model, the energy resolution and the shape of the threshold of the individual DANCE detectors are used as an input to provide realistic representation of the measured γ-ray spectra. In addition, the distance from each detector to the target is defined in an input file as well as the physical presence of the a detector in the DANCE and NEUANCE arrays. The azimuthal angle of NEUANCE is also an external parameter to be tuned to represent the measurement. Simulated spectra are compared with measurements with standard γ-ray calibrated sources.
Measurement of the helicity dependent elastic electron-proton scattering cross section provides a key means of investigating parity violation within the proton. However, such measurements exhibit potential instrumental effects associated with the detection of polarized recoiled protons. In particular, spin-orbit interactions within a massive detector induce a systematic spatial shift in the detector signal. In this study, we determine the size of this shift using the Geant4 simulation toolkit. For a typical hadron calorimeter, we found a polarization dependent shift on the order of 0.01-0.1 mm, multiple orders of magnitude smaller than the typical spatial resolution seen in hadronic calorimeters. Additionally, we provide the custom modifications required of the Geant4 source code to implement the quasi-elastic scattering of polarized protons incident on nuclei in the detector. The modifications are readily extendable to generic matter sources, and can be used for the study of additional spin dependent observables in Geant4.
Understanding how 3D power distribution will be monitored throughout reactor core volumetric space in next-generation nuclear power reactors is crucial to the design, deployment, and licensing of these reactors. Although numerous techniques exist for 3D power distribution monitoring based on the response of both in situ and ex situ sensors currently implemented or proposed for use in the US reactor fleet, crucial details about these techniques are often unclear. The publicly available documentation does not include information such as how well these techniques are characterized and optimized in their implementations and the levels of uncertainty in the inferred 3D power distribution. The work described herein investigated a recently developed 3D power distribution inferencing method as applied to two next-generation reactor simulations: (1) the NuScale small modular reactor design and (2) the Westinghouse AP1000 design, both of which contain in-core strings of vanadium self-powered neutron detectors (SPNDs). This investigation considered a range of SPND string sensor densities, as well as a range of 3D power distribution axial segment sizes. In this work, SPND response simulation is informed by neutron flux calculations in representative homogenized cores. For the different sensor densities and power distribution axial segment sizes in these simulations, the average solution error, solver iterations, and run time were tracked to parameterize the sensor-core configuration.
Neutrons can present a significant challenge for neutrino experiments in which energy reconstruction is critical. With the ability to escape detection completely and with a weak correlation between their kinetic energy and any eventual energy deposition, it is difficult to fully account for neutrons produced in neutrino interactions. This in turn leads to significant model dependence when evaluating neutron-related systematic uncertainties. The NOvA experiment is a long-baseline neutrino oscillation experiment with a high-statistics sample of antineutrino data collected by its near detector. We report an excess relative to data of simulated neutron candidates with low energy depositions when using standard Geant4 physics lists. The simulation excess is traced to an overabundance of secondary photons produced from interactions of neutrons with kinetic energy greater than \SI{20}{\mega\eV}. Improved agreement with data is obtained by applying the data-driven neutron-on-carbon \menate model for neutrons between \SI{20}{\mega\eV} and ${\sim}$\SI{100}{\mega\eV}. With \menate, the residual oversimulation is more uniform across the calorimetric neutron energy spectrum, suggesting possible overproduction of primary neutrons by the GENIE neutrino interaction generator. These results motivate the adoption of \menate-supplemented Geant4 simulation as the nominal simulation in the production of future \nova simulation.
The detection properties of CR-39 were investigated for protons, deuterons, and tritons of various energies. Two models for the relationship between the track diameter and particle energy are presented and demonstrated to match experimental data for all three species. Data demonstrate that CR-39 has 100% efficiency for protons between 1 MeV and 4 MeV, deuterons between 1 MeV and 12.2 MeV, and tritons between 1 MeV and 10 MeV. The true upper bounds for deuterons and tritons exceed what could be measured in data. Simulations were developed to further explore the properties of CR-39 and suggest that the diameter–energy relationship of alpha particles cannot be captured by the conventional c-parameter model. These findings provide confidence in CR-39 track diameter based spectroscopy of all three species and provide invaluable insight for designing filtering for all CR-39 based diagnostics.
Explore the source record for details and available documents.
Helium-3 tubes are an efficient way to detect neutrons after they have thermalized by polyethylene. They are often arranged in rings to perform coincidence counting. Applications include nuclear safeguards, treaty verification, and emergency response. DRiFT has the ability to simulate pile-up, room return, and end effects. A new feature determines real and accidental correlated counts. The next steps include DRiFT 2.0 released as executable, continued demonstration of gas module capabilities, and semiconductor module under a development.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The NOvA Test Beam Program was commissioned to complement the full-scale NOvA experiment in its goal of measuring neutrino oscillations. The NOvA Experiment consists of a 300-ton Near Detector and a 14-kton Far Detector, both exposed to the same beam, which can be operated in neutrino or antineutrino mode from Fermilab at an off-axis angle of 14.6~mrad. These detectors can discriminate between $\nu_\mu$-CC and $\nu_e$-CC neutrino (or corresponding antineutrino) events, enabling appearance and disappearance measurements of these flavors across the \SI{810}{\kilo\meter} near-to-far detector baseline. From these measurements, the underlying parameters of the three-flavor PMNS oscillations framework are measured. The NOvA Test Beam uses identical technology to the full-scale detectors, but scaled down to 30~tons. It is exposed to a beam of charged particles closely matched to the daughter products of NOvA (anti)neutrino interactions in both energy and species. An instrumented beamline determines both particle momentum and species upstream of the NOvA detector, allowing for a crisp measurement of the NOvA detector response to these known inputs. This dissertation presents an analysis of the electromagnetic response of the NOvA hardware and establishes a framework for incorporating these results to enhance the physics reach of the experiment. Prior to this work, the electromagnetic energy response of the NOvA detector relied primarily on simulation-driven calibration together with a globally applied energy scale uncertainty. The measurements presented here provide direct test beam constraints on the detector response, enabling particle-dependent and potentially energy-dependent uncertainty models derived from controlled electromagnetic inputs.
The Multiplicity Counter 15 tube detector or MC-15 is an optimized detector designed for use in the field. It is composed of 15 3 He tubes embedded in high density polyethylene (HDPE). Recent work has explored expanding the use of the MC-15 beyond multiplicity counting to neutron dosimetry applications. Knowledge of the neutron energy spectrum information is required to use a detector as a neutron dosimeter. The MC-15 tube layout is shown in Figure 1. The unique layout makes it possible to use the detector for neutron spectroscopy via spectrum unfolding. Spectrum unfolding requires (1) energy dependence of the detector response, (2) a detector response matrix that precisely quantifies the response to mono-energetic neutrons, (3) an initial guess spectrum, (4) an unfolding algorithm, and (5) measured data (counts in the case of the MC-15). An energy dependent detector response matrix (DRM) can be constructed by considering either each of the three rows of 3 He tubes as a distinct detector or each individual tube as a distinct detector. The HDPE separating the 3 He in the MC-15 provides the distinct energy dependent response for the rows and individual tubes. In this report we detail the development of detector response matrices for the MC-15 and the application of the Los Alamos Unfolding Code (LUC) to both simulated and measured data. Three MC-15 orientations were studied: (1) standard orientation with the MC-15 front facing the source, (2) standard orientation with Cd sheet, (3) 90° orientation with the side of the MC-15 facing the source.
Detecting radioactive sources in an urban environment is difficult due to the large magnitude and variability of the background radiation. To support the search mission of the National Nuclear Security Administration, a project was undertaken to determine if first-principles modeling and simulation could be used to accurately predict the response of radiation detectors in urban environments. This study demonstrates that the simulated detector responses to photon radiation from both an isotopic source and the background compare well to benchmark-quality measurements in a large urban-like test environment. Simulation results using a traditional combinatorial solid geometry and a CAD model generated from LiDAR measurements gave very similar detector responses. With this validation, further simulations could be used to predict detector responses for various situations in real urban settings.
This paper details the generation of synthetic radiation data using large-scale Monte Carlo transport models to evaluate radiation search detection algorithms. Modular 3-D Monte Carlo models spanning multiple city blocks were constructed, loosely based on downtown Knoxville, TN, containing buildings composed of multiple materials (brick, granite, and concrete), sidewalks, a four-lane road, side streets, parking lots, and grassy fields. Background and simulated source detector response calculations from these models were used to create synthetic list mode data sets for a 2"×4"×16" NaI(Tl) detector moving through a city street at a constant speed. For the background simulations, major isotopes were computed individually so that background composition and variability could be computed efficiently outside Monte Carlo. The source detector response included six simulated sources placed at 15 source locations. Detector response was developed to be periodic through the city street so that a detector path could begin at one end of the model and wrap around to the other. This framework allowed for the creation of diverse data sets, each with its own unique background and simulated source detector response. Synthetic data allows for high-quality labels, which are useful in developing data-driven radiation detection algorithms. This methodology was used to create synthetic data sets which were released as part of a public data competition to spur the development of new radiation detection algorithms for radiological search applications.
The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-toend performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.
The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-to-end performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.