Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Microwave biasing improves detector response in the infrared region

Detection system, which incorporates advantages of microwave biasing, measures output of a carbon dioxide laser at 10.6 microns with a factor of 1,000 improvement in sensitivity. Material lifetime, rather than external circuitry, limits detector response time.

Sun, C.↗

Estimating Cosmic Ray Spectral Parameters from Simulated Detector Responses

A simple power law model consisting of a single spectral index al is believed to be an adequate description of the galactic cosmic ray (GCR) proton flux at energies below 100 TeV, with a transition at kink energy Ek to a steeper spectral index a2>al above Ek. The maximum likelihood procedure is developed for estimating these three spectral parameters of the broken power law energy spectrum from simulated detector responses. These estimates and their surrounding statistical uncertainty are being used to derive the requirements in energy resolution, calorimeter size, and energy response of a proposed sampling calorimeter for the Advanced Cosmic-ray Composition Experiment for the Space Station (ACCESS). This study thereby permits instrument developers to make important trade studies in design parameters as a function of the science objectives, which is particularly important for space-based detectors where physical parameters, such as dimension and weight, impose rigorous practical limits to the design envelope.

Howell, Leonard↗

Detector Response and Battery Reliability

The Sandia National Laboratories (SNL) Material Control and Accountability (MC&A) measurements team performs confirmation measurements of Special Nuclear Material (SNM) at different locations around Sandia. The measurement team has access to two High purity Germanium (HPGe) detectors, the AEGIS (Model: AEGIS-BEGE5030), and the ORTEC (Model: trans-SPEC-DX-100). These two can operate purely on battery power, but the response of the detectors while on battery power is not well documented. To enhance our knowledge with these detectors the team wants to investigate the detectors response to changes in battery range, wall charging, and mid operation battery swaps (Hot Swaps).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of Source Geometry on Detector Response Matrix Efficiency: Simulations of the PFUNS-MUSiC Experiments

This work looks at two different bare highly enriched uranium (HEU) systems, configuration one from Measurements of Uranium Subcritical and Critical (MUSiC) and Prompt Fission Uranium Neutron Spectrum (PFUNS) to see the effect geometry has on detector efficiency and the response matrix. The distance from the multiplying source, the medium between the source and detector, and the geometry of the source all play a part in the efficiency of the detector. These factors are especially important when performing spectrum unfolding. Spectrum unfolding is a process used to reconstruct a true spectrum from measured detector response data. It involves interpreting a set of measured values, such as a light signal from a scintillator, to recover the original neutron energy spectrum. This leads to the question, how much will the efficiency of a detector change when you measure a point source compared to an extended source? The distance and solid angle from the source to the detector may be different. It may only be a minuscule change, but in the spectrum unfolding process it can have a considerable effect on the unfolded spectrum

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detailed Characterization of CZT Detector Response for Improved Coded-Aperture Imaging Performance

Gamma-ray imaging is a powerful method for locating and quantifying sources of radiation. The coded-aperture technique demonstrates superior angular resolution in comparison to other methods (e.g., Compton reconstruction). In this method, a mask constructed of highly attenuating material encodes the scene as a shadow pattern on a position-sensitive detector; this pattern can then be used to recreate the origin(s) of incident radiation. This is typically done through convolution of the mask and shadow patterns. Iterative methods which attempt to reconstruct the observed shadow pattern using a weighted combination of simulated patterns may also be employed. In either case, errors in event position reconstruction due to detector imperfections alter the shadow pattern and will therefore degrade system performance and may introduce imaging artifacts. These effects can be mitigated with a detailed understanding of such errors – allowing for the generation of representative simulations that include the errors and/or correction of raw imager data to remove the errors. We present a calibration process for a commercially available cadmium zinc telluride (CZT) gamma imager which provides a comprehensive characterization of the spatial and energy dependence of event reconstruction. By illuminating a mask featuring a regular grid of pinholes with a calibration source, the localized response of the detector can be measured with fine granularity. These local responses are combined to generate a full detector response map which can be used to distort simulations in a manner that is representative of the observed detector data. Details of the calibration procedure and an assessment of the impact of its end products on the performance of iterative imaging methods will be presented.

Ziock, Klaus-Peter↗

Nonlinear Detector Response of Aqua MODIS Land Imaging Bands

The detectors in Aqua MODIS reflective solar bands (RSB) are calibrated assuming a linear relationship between the observed top-of-atmosphere radiance and the instrument output response. Any non-linear behavior in the system response can contribute to errors in NASA’s Level 1B MODIS reflectance and radiance products, which are used in a wide variety of Earth science applications. While most RSB detectors continue to have very linear behavior even after more than 18 years of operation, we present evidence that the detectors in Aqua MODIS bands 1 (645 nm) and 2 (858 nm) have deviations from gain linearity that change over the mission by up to 3%. We show a clear divergence between gain measurements made with the on-board solar diffuser (SD) at two different radiance levels, achieved by collecting data both with and without an attenuation screen. Radiance trends from lunar calibrations and typical desert and ocean scenes are also compared. We present a simple method to characterize the response non-linearity using a quadratic function by combining the results of the two sets of SD calibrations. Applying this quadratic calibration algorithm to the desert and lunar data results in improved agreement in their long-term radiance trends. A clear understanding of the magnitude of the gain non-linearity could be useful to help improve the quality of numerous MODIS science products, including the land imaging applications that rely heavily on these bands.

MODIS↗

Infrared detector responsivity measured simultaneously at multiple frequencies

The responsivity (the ratio of the output electrical signal to the incident radiation power) of an IR detector is measured at several frequencies simultaneously. A computer-controlled variable frequency chopper is used. Chopper modulation of a blackbody is square-wave-like, hence measurements can be taken not only at the fundamental frequency but also at the harmonics. The technique gives excellent agreement with the classical technique of measuring the fundamental response alone at a set of modulation frequencies. With a small enough aperture and a high enough chopper speed, agreement can be within five percent out to 31 times the fundamental frequency. The technique allows the rapid and automated acquisition of the frequency response of IR detectors, which may then be screened for responsivity, noise, and noise equivalent power.

Brasunas, John C.↗

Ultrafast IR detector response in high Tc superconducting thin films

The response from a high Tc superconducting multielement optical detector made of a laser deposited Y-Ba-Cu-O thin film has been evaluated. Several microscopic and spectroscopic techniques were used to establish the presence of the correct phase of the thin film. Optical pulses from a laser diode at 830 nm and from a Q-switched CO2-laser at 10.6 microns were used. The detector responded to 50 ps (FWHM) pulses. A comparison between dR/dT of the film and the response amplitude as a function of temperature indicated a bolometric response.

Lindgren, Mikael↗

Unpaired image translation to mitigate domain shift in liquid argon time projection chamber detector responses

Deep learning algorithms often are developed and trained on a training dataset and deployed on test datasets. Any systematic difference between the training and a test dataset may severely degrade the final algorithm performance on the test dataset—what is known as the domain shift problem . This issue is prevalent in many scientific domains where algorithms are trained on simulated data but applied to real-world datasets. Typically, the domain shift problem is solved through various domain adaptation (DA) methods. However, these methods are often tailored for a specific downstream task, such as classification or semantic segmentation, and may not easily generalize to different tasks. This work explores the feasibility of using an alternative way to solve the domain shift problem that is not specific to any downstream algorithm. The proposed approach relies on modern Unpaired Image-to-Image (UI2I) translation techniques, designed to find translations between different image domains in a fully unsupervised fashion. In this study, the approach is applied to a domain shift problem commonly encountered in Liquid Argon Time Projection Chamber (LArTPC) detector research when seeking a way to translate samples between two differently distributed LArTPC detector datasets deterministically. This translation allows for mapping real-world data into the simulated data domain where the downstream algorithms can be run with much less domain-shift-related performance degradation. Conversely, using the translation from the simulated data to a real-world domain can increase the realism of the simulated dataset and reduce the magnitude of any systematic uncertainties. To evaluate the quality of the translations, we use both pixel-wise metrics and a downstream task to measure the effectiveness of UI2I methods for mitigating the domain shift problem. We adapted several popular UI2I translation algorithms to work on scientific data and demonstrated the viability of these techniques for solving the domain shift problem with LArTPC detector data. To facilitate further development of DA techniques for scientific datasets, the ‘Simple Liquid-Argon Track Samples’ dataset used in this study is also published.

97 MATHEMATICS AND COMPUTING↗

RadSim: Detector Response

This package simulates the expected output gamma spectra from a gamma detector for given configuration.

Hangal, DhanushA [Lawrence Livermore National Labo↗

Characterization of Photon-Counting Detector Responsivity for Non-Linear Two-Photon Absorption Process

Sub-band absorption at 1550 nm has been demonstrated and characterized on silicon Geiger mode detectors which normally would be expected to have no response at this wavelength. We compare responsivity measurements to singlephoton absorption for wavelengths slightly above the bandgap wavelength of silicon (approx. 1100 microns). One application for this low efficiency sub-band absorption is in deep space optical communication systems where it is desirable to track a 1030 nm uplink beacon on the same flight terminal detector array that monitors a 1550 nm downlink signal for pointingcontrol. The currently observed absorption at 1550 nm provides 60-70 dB of isolation compared to the response at 1064 nm, which is desirable to avoid saturation of the detector by scattered light from the downlink laser.

Geiger mode detector↗

Detector response in time-of-flight mass spectrometry at high pulse repetition frequencies

Dead time effects in chevron configured dual microchannel plates (MCPs) are investigated. Response times are determined experimentally for one chevron-configured dual MCP-type detector and two discrete dynode-type electron multipliers with 16 and 23 resistively divided stages. All of these detectors are found to be suitable for time-of-flight mass spectrometry (TOF MS), yielding 3-6-ns (FWHM) response times triggered on a single ion pulse. It is concluded that, unless there are viable solutions to overcome dead time disadvantages for continuous dynode detectors, suitable discrete dynode detectors for TOF MS appear to have a significant advantage for high repetition rate operation.

Gulcicek, Erol E.↗

Fire detector response in aircraft applications

Photoelectric, ionization, and gas sensors were used to detect the signatures from the radiant heat or flame of various aircraft materials. It was found that both ionization and photoelectric detectors are about equally capable of detecting products of pyrolysis and combustion of synthetic polymers, especially those containing fire-retardant additives. Ionization detectors alone appeared to be sensitive to combustion products of simple cellulosic materials. A gas sensor detector appeared to be insensitive to pyrolysis or combustion products of many of the materials.

Wiersma, S. J.↗

GEANT4 code for DANCE with NEUANCE detector-response simulations

A new GEANT4 model for DANCE with NEUANCE has been developed to account for the change in the DANCE configuration when NEUANCE is installed. In this model, the energy resolution and the shape of the threshold of the individual DANCE detectors are used as an input to provide realistic representation of the measured γ-ray spectra. In addition, the distance from each detector to the target is defined in an input file as well as the physical presence of the a detector in the DANCE and NEUANCE arrays. The azimuthal angle of NEUANCE is also an external parameter to be tuned to represent the measurement. Simulated spectra are compared with measurements with standard γ-ray calibrated sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simulation of the spatial shift in detector response for polarized protons within a calorimeter

Measurement of the helicity dependent elastic electron-proton scattering cross section provides a key means of investigating parity violation within the proton. However, such measurements exhibit potential instrumental effects associated with the detection of polarized recoiled protons. In particular, spin-orbit interactions within a massive detector induce a systematic spatial shift in the detector signal. In this study, we determine the size of this shift using the Geant4 simulation toolkit. For a typical hadron calorimeter, we found a polarization dependent shift on the order of 0.01-0.1 mm, multiple orders of magnitude smaller than the typical spatial resolution seen in hadronic calorimeters. Additionally, we provide the custom modifications required of the Geant4 source code to implement the quasi-elastic scattering of polarized protons incident on nuclei in the detector. The modifications are readily extendable to generic matter sources, and can be used for the study of additional spin dependent observables in Geant4.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulating self-powered neutron detector responses to infer burnup-induced power distribution perturbations in next-generation light water reactors

Understanding how 3D power distribution will be monitored throughout reactor core volumetric space in next-generation nuclear power reactors is crucial to the design, deployment, and licensing of these reactors. Although numerous techniques exist for 3D power distribution monitoring based on the response of both in situ and ex situ sensors currently implemented or proposed for use in the US reactor fleet, crucial details about these techniques are often unclear. The publicly available documentation does not include information such as how well these techniques are characterized and optimized in their implementations and the levels of uncertainty in the inferred 3D power distribution. The work described herein investigated a recently developed 3D power distribution inferencing method as applied to two next-generation reactor simulations: (1) the NuScale small modular reactor design and (2) the Westinghouse AP1000 design, both of which contain in-core strings of vanadium self-powered neutron detectors (SPNDs). This investigation considered a range of SPND string sensor densities, as well as a range of 3D power distribution axial segment sizes. In this work, SPND response simulation is informed by neutron flux calculations in representative homogenized cores. For the different sensor densities and power distribution axial segment sizes in these simulations, the average solution error, solver iterations, and run time were tracked to parameterize the sensor-core configuration.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Neutron detector response modeling in NOvA

Neutrons can present a significant challenge for neutrino experiments in which energy reconstruction is critical. With the ability to escape detection completely and with a weak correlation between their kinetic energy and any eventual energy deposition, it is difficult to fully account for neutrons produced in neutrino interactions. This in turn leads to significant model dependence when evaluating neutron-related systematic uncertainties. The NOvA experiment is a long-baseline neutrino oscillation experiment with a high-statistics sample of antineutrino data collected by its near detector. We report an excess relative to data of simulated neutron candidates with low energy depositions when using standard Geant4 physics lists. The simulation excess is traced to an overabundance of secondary photons produced from interactions of neutrons with kinetic energy greater than \SI{20}{\mega\eV}. Improved agreement with data is obtained by applying the data-driven neutron-on-carbon \menate model for neutrons between \SI{20}{\mega\eV} and ${\sim}$\SI{100}{\mega\eV}. With \menate, the residual oversimulation is more uniform across the calorimetric neutron energy spectrum, suggesting possible overproduction of primary neutrons by the GENIE neutrino interaction generator. These results motivate the adoption of \menate-supplemented Geant4 simulation as the nominal simulation in the production of future \nova simulation.

Abubakar, S.↗

CR-39 nuclear track detector response to inertial confinement fusion relevant ions

The detection properties of CR-39 were investigated for protons, deuterons, and tritons of various energies. Two models for the relationship between the track diameter and particle energy are presented and demonstrated to match experimental data for all three species. Data demonstrate that CR-39 has 100% efficiency for protons between 1 MeV and 4 MeV, deuterons between 1 MeV and 12.2 MeV, and tritons between 1 MeV and 10 MeV. The true upper bounds for deuterons and tritons exceed what could be measured in data. Simulations were developed to further explore the properties of CR-39 and suggest that the diameter–energy relationship of alpha particles cannot be captured by the conventional c-parameter model. These findings provide confidence in CR-39 track diameter based spectroscopy of all three species and provide invaluable insight for designing filtering for all CR-39 based diagnostics.

47 OTHER INSTRUMENTATION↗